2.1 Sicherheit von Energieträgern
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (7) (entfernen)
Referierte Publikation
- nein (7)
Schlagworte
- Explosionsschutz (2)
- Hybride Gemische (2)
- Ignition source (2)
- Sicherheitstechnische Kenngrößen (2)
- ATEX (1)
- Alternative Antriebe (1)
- Auswirkungsbetrachtung (1)
- Behälterversagen (1)
- Explodierender Draht (1)
- Exploding Wire (1)
Organisationseinheit der BAM
Mechanical friction, impact or abrasion is one of the ignition sources that must be avoided in hazardous zones with explosive atmospheres. The effectiveness of mechanical impacts as ignition source is dependent from several parameters including the minimum ignition energy of the explosive atmosphere, the properties of the material pairing, the kinetic impact energy or the impact velocity. By now there is no standard procedure to determine the effectiveness of mechanical impacts as ignition source. In this work the effectiveness of mechanical impacts with defined and reproducible kinetic impact energy as ignition source for hydrogen containing atmospheres was studied systematically in dependence from the inhomogeneous material pairing considering materials with practical relevance like stainless steel, low alloy steel, concrete, and non-iron-metals. It was found that ignition can be avoided, if non-iron metals are used in combination with different metallic materials, but in combination with concrete even the impact of non-iron-metals can be an effective ignition source if the kinetic impact energy is not further limited. Moreover, the consequence of hydrogen admixture to natural gas on the effectiveness of mechanical impacts as ignition source was studied. In many cases ignition of atmospheres containing natural gas by mechanical impacts is rather unlikely. No influence could be observed for admixtures up to 25% hydrogen and even more. The results are mainly relevant in the context of repurposing the natural gas grid or adding hydrogen to
the natural gas grid.
For the determination of safety characteristics of gases, vapors and dusts different types of ignition sources are used in international standards and guidelines. Table 1 compares technical relevant ignition sources with their main features. The paper presents test results of a comparative calorimetric and visual study between four different types of ignition sources. The ignition procedures were analyzed visually with a high-speed camera and electric recordings. In addition to that, the influence of the electrode-orientation, -distance as well as ignition energy on the reproducibility of the exploding wire igniter was tested.
The exploding wire is already in use for standardized determination of safety characteristics of gases, first tests on the suitability of the exploding wire igniter for dust testing have been carried out by Scheid et al. Using the exploding wire, the ignition energy can be varied from 2 to 10 000 J (2 x 5 000 J) and thus it could be used for gases, vapors, dusts and hybrid mixtures. Moreover it can be used at high initial pressures and it is the only ignition source with an easily measurable ignition energy release. Furthermore, it does not introduce another chemical reaction into the system.
Finally, a proposal for a standard ignition source for explosion tests on hybrid mixtures is derived from the test results.
Entwicklungen zu Bestimmungsverfahren für sicherheitstechnische Kenngrössen hybrider Gemische
(2020)
Zur Bestimmung sicherheitstechnischer Kenngrößen (STK) von hybriden Gemischen (Gemisch aus mindestens zwei brennbaren Phasen, wie z.B. Staub/Gas- oder Gas/Dampf-Gemisch) existieren bislang keine einheitlichen, genormten Prüfmethoden. Die Normen und Regelwerke zur Bestimmung der STK von einphasigen brennbaren Systemen (Staub, Gas, Dampf) unterscheiden sich teilweise erheblich. Beispielsweise sind in den jeweiligen Normen für Stäube, Gase und Dämpfe unterschiedliche Zündquellen und Zündenergien definiert. Des Weiteren unterscheiden sich die in den Normen definierten Prüfabläufe bei der Gemischherstellung. Bei der Entwicklung einer einheitlichen Norm für hybride Gemische muss der Einfluss dieser beiden Parameter ermittelt werden, um die Vergleichbarkeit mit den STK der einzelnen Komponenten Gas, Staub und Dampf gewährleisten zu können und bisherige Erkenntnisse zu hybriden Gemischen interpretieren und bewerten zu können.
In diesem Verbundvorhaben werden standardisierte Messverfahren für hybride Gemische erarbeitet, die der Bestimmung sicherheitstechnischer Kenngrößen des Explosionsschutzes dienen. Unter einem hybriden Gemisch wird dabei ein mehrphasiges System aus Brenngas oder brennbarem Dampf, sowie Luft und brennbarem Staub verstanden. Die Veröffentlichung der Ergebnisse erfolgt in einem Abschlussbericht und als DIN-Spezifikation (DIN SPEC). Diese DIN SPEC versetzt Prüfinstitute und Industrie in die Lage, Explosionsgefahren beim Betrieb technischer Anlagen mit hybriden Gemischen einzuschätzen und damit Prozesse sowohl sicherer als auch effizienter zu steuern. Dieses Projekt wird im Rahmen des WIPANOProgramms (Wissens- und Technologietransfer durch Patente und Normen) vom BMWi gefördert.
Most fluorinated hydrocarbons that shall replace refrigerants with high GWP, like R134a, are flammable. For evaluating inertization measures for explosion protection, flammability of low-GWP refrigerants R1234yf, R32 and R1132a blended with carbon dioxide, nitrogen and argon were studied experimentally in a closed autoclave at atmospheric conditions. Furthermore, a calculation method was adapted to reduce the experimental costs for flammability studies on these gas mixtures. For igniting R1234yf in the closed autoclave a newly developed ignition system was used that allows generating electric arcs with high ignition energy. Gas mixtures containing the mildly flammable R1234yf and R32 could be inerted by adding much less inert gas than mixtures containing R1132a, which is more similar to unfluorinated hydrocarbons regarding the explosion regions. By using the adapted model of constant adiabatic flame temperature profiles estimating the explosion limits of fluorinated hydrocarbons was possible with similar accuracy as for unfluorinated hydrocarbons.
Keywords: Explosion Protection, Inertization, Flammability, HFOs, HFC., R1234yf, R32, R1132a
Die Explosionsbereiche für Dreistoffsysteme aus Brennstoff, Inertgas und Luft wurden nach dem Modell der konstanten adiabatischen Flammentemperaturprofile berechnet. Für die Parametrisierung des halbempirischen Modells muss der Explosionsbereich für ein bestimmtes Dreistoffsystem aus Brennstoff, Inertgas und Luft bekannt sein. Dann lassen sich Explosionsbereiche desselben Brennstoffs mit einem beliebigen Inertgas und bei einer beliebigen Temperatur berechnen. Ergänzend zu früheren Arbeiten, in denen die Explosionsbereiche für Brenngase aus der homologen Reihe der Alkane und Alkene berechnet worden sind, wurden nun die Berechnungen für 1-Propanol, Aceton und Difluormethan durchgeführt. Als Inertgase wurden neben Stickstoff und Kohlendioxid auch die Edelgase Argon und Helium berücksichtigt. Für die Berechnung der Explosionsbereiche in Systemen mit Helium, ist das Modell erweitert worden, so dass auch die Transporteigenschaften (d.h. Wärmeleitfähigkeit, Diffusionskoeffizient) der Komponenten berücksichtigt werden. Weiterhin ist eine Möglichkeit zur praxisnahen Berechnung der Spitze des Explosionsbereichs implementiert worden. Die Ergebnisse zeigen insgesamt, dass die Berechnung der Explosionsbereiche für Alkohole, Ketone und halogenierte Kohlenwasserstoffe mit ähnlicher Genauigkeit wie für Alkane und Alkene möglich ist. Die vorgenommenen Modifikationen sind geeignet, um auch eine Berechnung für Gasgemische mit Helium durchzuführen, dessen starke inertisierende Wirkung im Vergleich zu den Inertgasen Argon oder Stickstoff vor allem auf den stark unterschiedlichen Transporteigenschaften beruht. Für die Analyse der physikalischen Vorgänge, die zur Zündung führen, ist eine spezielle Kontaktvorrichtung entwickelt worden. Damit können die Entladungen > 200 µm Länge und mit einer Dauer von > 500 µs an einer bestimmbaren Position erzeugt und untersucht werden.
Für die Entladungen an der Zündgrenze bei niedrigen Spannungs- und Stromwerten (max. 30 V, 30 bis 100 mA Konstantstrombegrenzung) sind die Bedingung für die Erzeugung ermittelt worden. Das sind die Rauheit auf der Kontaktoberfläche, die langsame Kontaktöffnungsbewegung und eine geeignet regelnde Spannungsquelle mit Konstantstrombegrenzung. Damit sind für diese Entladungen an der Zündgrenze die Strom-Spannungs-Kennlinie, das Spektrum mit dominierenden Linien von Cadmium-Metalldampf sowie die Temperaturverläufe ermittelt worden.
In continuation of a preceding test series involving sole LPG vehicle tanks, three passenger cars equipped with identical toroidal steel LPG tanks were set on fire. The tanks were installed in the space normally reserved for the spare tyre, in the car boot. No safety device was installed on the tank, in order to force critical failure of the cylinder. Two of the cars were equipped with a tank filled with liquefied propane to a level of 20 % (5.3 kg), the third one was filled completely (25.5 kg). The partially filled tanks failed critically within a time period of more than 20 min after the initiation of the fire. The fully-filled tank did not rupture; the propane was released continuously through a small leak that appeared during the fire. Comprehensive equipment was used to procure measurement data, enabling an analysis of potential consequences and hazards to humans and infrastructure within the vehicle surroundings. The inner status of the tank (pressure, temperature of the liquid phase and the steel casing), the development of the fire (temperature inside and around the vehicle) and the pressure induced in the near-field in case of tank rupture were recorded. The results were analysed in detail and compared against the data gained in tests involving sole, but identical LPG tanks.