2 Prozess- und Anlagensicherheit
Filtern
Erscheinungsjahr
- 2018 (7) (entfernen)
Dokumenttyp
Sprache
- Englisch (7)
Referierte Publikation
- ja (7) (entfernen)
Schlagworte
- Aerial robot (1)
- BLEVE (1)
- Blast wave (1)
- Blends (1)
- Coating (1)
- Consequences (1)
- DAS (1)
- DVS (1)
- Distributed acoustic sensing (1)
- Distributed vibration sensing (1)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (7)
- 2.1 Sicherheit von Energieträgern (5)
- 2.2 Prozesssimulation (3)
- 8 Zerstörungsfreie Prüfung (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (2)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.0 Abteilungsleitung und andere (1)
- 5 Werkstofftechnik (1)
- 5.3 Polymere Verbundwerkstoffe (1)
- 5.6 Glas (1)
In this paper, we present an autonomous aerial robot to reconstruct tomographic 2D slices of gas plumes in outdoor environments. Our platform, the so-called Unmanned Aerial Vehicle for Remote Gas Sensing (UAV-REGAS) combines a lightweight Tunable Diode Laser Absorption Spectroscopy (TDLAS) sensor with a 3-axis aerial stabilization gimbal for aiming on a versatile octocopter. The TDLAS sensor provides integral gas concentration measurements but no information regarding the distance traveled by the laser diode's beam or the distribution of the gas along the optical path. We complemented the set-up with a laser rangefinder and apply principles of Computed Tomography (CT) to create a model of the spatial gas distribution from these integral concentration measurements. To allow for a rudimentary ground truth evaluation of the applied gas tomography algorithm, we set up a unique outdoor test environment based on two 3D ultrasonic anemometers and a distributed array of 10 infrared gas transmitters. We present first results showing the 2D plume reconstruction capabilities of the system under realistic conditions.
In case of a vehicle fire, an installed LPG (liquefied petroleum gas) tank with a malfunctioning safety device poses severe hazards. To investigate the consequences in case of tank failure, we conducted 16 tests with toroidal shaped LPG vehicle tanks. Three tanks were used for a Hydraulic Burst Test under standard conditions. Another three tanks were equipped with a statutory safety device and were subjected to a gasoline pool fire. The safety device prevented tank failure, as intended. To generate a statistically valid dataset on tank failure, ten tanks without safety devices were exposed to a gasoline pool fire. Five tanks were filled to a level of 20 %; the re-maining five were filled to a level of 100 %. In order to gain information on the heating process, three tem-perature readings at the tank surface, and three nearby flame temperatures were recorded. At distances of l = (7; 9; 11) m to the tank, the overpressure of the shock wave induced by the tank failure and the unsteady tem-peratures were measured. All ten tanks failed within a time of t < 5 min in a BLEVE (boiling liquid expanding vapor explosion). Seven of these resulted directly in a catastrophic failure. The other three resulted in partial failure followed by catastrophic failure. A near field overpressure at a distance of l = 7 m of up to p = 0.27 bar was measured. All ten tests showed massive fragmentation of the tank mantle. In total, 50 fragments were found. These 50 fragments make-up 88.6 % of the original tank mass. Each fragment was georeferenced and weighed. Fragment throwing distances of l > 250 m occurred. For the tanks with a fill level of 20 %, the average number of fragments was twice as high as it was for the tanks that were filled completely.
For evaluation of explosion scenarios in closed systems involving the mildly flammable refrigerants R1234yf, R1234ze and R32 dependent on the ignition energy, ignitions were carried out in a closed autoclave. A newly developed ignition system was used, which allows generating electric arcs with defined energies in a range between 3 J and 1000 J. The lower explosion limit of R32 decreases with increasing ignition energy. R32-explosions can be more severe than explosions involving highly flammable substances.
However, in case of R1234yf and R1234ze, the ignition energy had to be increased to more than 100 J and more than 500 J to detect explosions in the closed system at all, although flame Propagation phenomena can already be observed if these substances are ignited with much weaker ignition sources in open glass tubes. The explosions were very mild with these substances.
In the presented work, the potential of fiber-optic distributed acoustic sensing (DAS) for detection of small gas pipeline leaks (<1%) is investigated. Helical wrapping of the sensing fiber directly around the pipeline is used to increase the system sensitivity for detection of weak leak-induced vibrations. DAS measurements are supplemented with reference accelerometer data to facilitate analysis and interpretation of recorded vibration signals. The results reveal that a DAS system using direct fiber application approach is capable of detecting pipeline natural vibrations excited by the broadband noise generated by the leaking medium. In the performed experiment, pipeline vibration modes with acceleration magnitudes down to single ug were detected. Simple leak detection approach based on spectral integration of time-averaged DAS signals in frequency domain was proposed. Potential benefits and limitations of the presented monitoring Approach were discussed with respect to its practical applicability. We demonstrated that the approached is potentially capable of detection and localization of gas pipeline leaks with leak rates down to 0.1% of the pipeline flow volume and might be of interest for monitoring of short- and medium-length gas pipelines.
In present chapter, the potential usage of peroxy-fuels (usually known as organic peroxides) either in technically pure or in a blended form in engine combustion processes are explored. Although as additives (in small quantities <5% to conventional fuels, e.g., diesel, gasoline) peroxy-fuels are well known for many years their commercial applications as a main or primary fuel are not investigated in detail as such except a few. Their thermal instability and energy density demand great care during processing, which restricts their commercial exploitation. However, once the issues with safety are resolved they can be much more advantageously employed than conventional fuels. Some of these advantages are significant amount of fuel saving, reduction in amount of inducted air, or even the complete absence of air, i.e., anaerobic combustion, smaller volume of combustion (chamber), oxygenated fuel quality, and low emissions. An idea to develop the components of an engine operating solely on peroxy-fuels is also introduced. The engine concept is based on single and multiple injectors in a cylinder with special material coating to ensure a temperature-controlled processing.
The thermal radiation impact of organic peroxide fireballs is experimentally assessed using an infrared camera. Fireballs are generated while liquid peroxide filled steel drums are subjected to gas burner fire at different heating rates. Three large burning clouds are observed with varying flame characteristics. Thermal radiation properties are assessed by infrared images with the presented methods. Despite of the two-dimensional temperature fields, the flames are treated and characterized as three-dimensional objects. Fireball diameters and heights are calculated based on a representing radiating sphere with the same cloud volume. By the use of the solid flame model and assumptions for emissivity and transmissivity, heat fluxes and thermal radiation doses against distance are predicted. Thermal safety distances are presented based on the maximum irradiance and the allowed exposure time. The validation of the maximum and time-dependent radiation fields is achieved through heat flux sensors in varying distances to the fireball. The results prove the use of an infrared camera and a volume based size calculation to fully assess the thermal radiation hazards of fireballs.
The hydrogen tightness of high-pressure hydrogen storage is a Basic criterion for long-term storage. The H2 permeation coefficients of epoxy resin and a glass lacquer were determined to enable the geometric optimization of a glass capillary storage. It was found that the curing conditions have no significant influence on the H2 permeation coefficient of resin.
The H2 permeation coefficient of epoxy resin is only about three orders of Magnitude greater than that of borosilicate glass. This suggests that the initial pressure of 700 bar takes about 2.5 years to be halved in capillary array storage. Therefore, a high-pressure hydrogen storage tank based on glass capillaries is ideally suited for long-term storage in mobile applications.