2 Prozess- und Anlagensicherheit
Filtern
Dokumenttyp
- Zeitschriftenartikel (71)
- Buchkapitel (1)
- Beitrag zu einem Tagungsband (1)
Referierte Publikation
- ja (73) (entfernen)
Schlagworte
- Hybrid mixtures (12)
- Dust explosions (7)
- Gas explosions (6)
- Minimum ignition temperature (6)
- 20L-sphere (4)
- Safety characteristics (4)
- Thermal runaway (4)
- Fireball (3)
- Hydrogen (3)
- Inerting effect (3)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (73)
- 2.1 Sicherheit von Energieträgern (64)
- 2.2 Prozesssimulation (8)
- 8 Zerstörungsfreie Prüfung (8)
- 7 Bauwerkssicherheit (5)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (5)
- 3 Gefahrgutumschließungen; Energiespeicher (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 2.0 Abteilungsleitung und andere (3)
- 3.0 Abteilungsleitung und andere (2)
Paper des Monats
- ja (2)
The combustion characteristics and explosive hazard of syngas (H2/CO)/air mixtures are affected by its exact composition and equivalence ratios. In this paper, the explosion pressure and spectral radiant intensity of free radicals were quantitatively examined for syngas with different H2 proportions ([H2 in syngas] = 0, 30, 50, 70, 100 vol%) and equivalence ratios (φ = 0.8, 1.0, 1.2, 1.4, 1.6, 2.0, 2.5). The results show that the explosion process of syngas/air mixtures can be separated into the initial slow combustion stage, the violent deflagration stage and the deflagration ending stage. The peaks of explosion pressure, pressure rise rate, OH*spectral intensity and rise rate of spectral intensity first increase and then decrease with increasing the equivalence ratio, and they reduce gradually with the decrease of H2 proportion in syngas. The H2 content in syngas greatly affects the heat release and the concentration of excited state OH*, especially for the syngas/air mixtures with smaller proportion of H2. Additionally, the presence of H2 greatly increases the deflagration index and spectral radiant index of OH* for syngas/air mixtures. The average rise rates of explosion pressure and spectral intensity of free radicals are introduced and the coupling model between them is established based on the first law of thermodynamics and the principle of chain reaction. The established model is furthermore verified by the experimental results. It is indicated that there is a linear relationship between average rise rates of explosion pressure and spectral intensity (OH*). The results can be used to improve the combustion efficiency of syngas and to guide theoretically the prevention, mitigation and control of syngas explosions.
Die Einführung von Wasserstoff als sicherer Energieträger braucht eine robuste Wissensbasis, darauf aufgebaute Werkzeuge zur Auslegung und Sicherheitsbewertung von Wasserstofftechnologien und ein international harmonisiertes Regelwerk. Viele der innovativen Technologien implizieren Wasserstoff bei hohen Drücken und/oder kryogenen Temperaturen, mit denen in verteilten Anwendungen erstmalig private Nutzer in Kontakt kommen. Um überkonservative, teure Sicherheitslösungen zu vermeiden, gleichzeitig aber die Einsetzbarkeit und Sicherheit von Wasserstoffanwendungen zu demonstrieren und die Akzeptanz für die Technologie aufrecht zu halten, muss auch die Sicherheitsforschung mit den Trends der technologischen Entwicklung Schritt halten, oder sie besser noch antizipieren. So beschreibt dieser Überblicksartikel nicht nur den gegenwärtigen Stand der Kenntnisse und Technik bezüglich Wasserstoffsicherheit, sondern auch ihre Weiterentwicklung.
minimum explosion concentration (MEC) and limiting oxygen concentration (LOC) in our recent works. This work further studies the reasonability and reliability of the alternative method experimentally and theoretically. Six different dust samples were tested via a 20-L spherical explosion chamber. The experimental results showed that the data of MEC and LOC determined by using the alternative and the standardized methods are in good agreement. The minimum flame propagation velocity (Sf) and the corresponding maximum combustion duration time (tc) were found at its MEC and LOC, suggesting that the theoretical analysis can well explain all the experimental data. It is the first time to study the theoretical basis of the explosion criterion, thus helping to improve our understandings of dust explosion characteristics, and to amend the explosion criterion in future test standards.
The maximum rate of pressure rise (dp/dt)𝑚𝑎𝑥 and the corresponding K-value of hybrid mixtures containing flammable gases and dusts are important for constructive explosion protection measures. Since the safety characteristics of dusts and gases are determined under different conditions, there has been considerable confusion about the influence of flammable gas on the (dp/dt) of dusts and vice versa. While some investigations showed comparably higher values for hybrid mixtures, others stated that the highest value for the gas component alone is the worst case.
The first part of this paper focuses on the confusion around the different statements about (dp/dt)𝑚𝑎𝑥 of hybrid mixtures and where they come from. In the second part of this paper experimental results are presented that illustrate how to clarify the different findings of past research and show what to expect as a real worst-case-value for hybrid mixtures.
For a comprehensive safety assessment of stationary lithium-ion-battery applications, it is necessary to better understand the consequences of thermal runaway (TR). In this study, experimental tests comprising twelve TR experiments including four single-cell tests, two cell stack tests and six second-life module tests (2.65 kW h and 6.85 kW h) with an NMC-cathode under similar initial conditions were conducted. The temperature (direct at cells/modules and in near field), mass loss, cell/module voltage, and qualitative vent gas composition (Fourier transform infrared (FTIR) and diode laser spectroscopy (DLS) for HF) were measured. The results of the tests showed that the battery TR is accompanied by severe and in some cases violent chemical reactions. In most cases, TR was not accompanied by pregassing of the modules. Jet flames up to a length of 5 m and fragment throwing to distances to more than 30 m were detected. The TR of the tested modules was accompanied by significant mass loss of up to 82%. The maximum HF concentration measured was 76 ppm, whereby the measured HF concentrations in the module tests were not necessarily higher than that in the cell stack tests.
Subsequently, an explosion of the released vent gas occurred in one of the tests, resulting in the intensification of the negative consequences. According to the evaluation of the gas measurements with regard to toxicity base on the “Acute Exposure Guideline Levels” (AEGL), there is some concern with regards to CO, which may be equally as important to consider as the release of HF.
Composition and Explosibility of Gas Emissions from Lithium-Ion Batteries Undergoing Thermal Runaway
(2023)
Lithium-based batteries have the potential to undergo thermal runaway (TR), during which mixtures of gases are released. The purpose of this study was to assess the explosibility of the gaseous emission from LIBs of an NMC-based cathode during thermal runaway. In the current project, a series of pouch lithium-based battery cells was exposed to abuse conditions (thermal) to study the total amount of gases released and the composition of the gas mixture. First, the battery cells were placed in a closed vessel, and the pressure and temperature rise inside the vessel were measured. In a second step, the composition of gases was analysed using a Fourier transform Infrared (FTIR) spectrometer.
We found that the amount of released gases was up to 102 ± 4 L, with a clear dependence on the battery capacity. This study showed that the concentration of gaseous emissions such as carbon monoxide (CO), methane (CH4), ethylene (C2H4), ethane (C2H6), and hydrogen cyanide (HCN) increased with higher cell capacity. Of the five studied flammable gases, the maximum concentrations of carbon monoxide (16.85 vol%), methane (7.6 vol%), and ethylene (7.86 vol%) were identified to be within their explosible range. Applying Le Chatelier’s law, a calculated lower explosion limit (LEL) of 7% in volume fraction was obtained for the gas mixture. The upper explosion limit (UEL) of the gas mixture was also found to be 31% in volume. A filter comprising pyrobubbles was used for the removal of the studied gas components released during the thermal abuse. The investigation revealed that the pyrobubbles filter was highly effect in the removal of HCN (up to 94% removal) and CO2 (up to 100% removal). Herein, we report the dependency of the method of thermal runaway trigger on the measured maximum temperature.
The flammable hydrogen-blended methane–air and natural gas–air mixtures raise specific safety and environmental issues in the industry and transportation; therefore, their explosion characteristics such as the explosion limits, explosion pressures, and rates of pressure rise have significant importance from a safety point of view. At the same time, the laminar burning velocities are the most useful parameters for practical applications and in basic studies for the validation of reaction mechanisms and modeling turbulent combustion. In the present study, an experimental and numerical study of the effect of hydrogen addition on the laminar burning velocity (LBV) of methane–air and natural gas–air mixtures was conducted, using mixtures with equivalence ratios within 0.90 and 1.30 and various hydrogen fractions rH within 0.0 and 0.5. The experiments were performed in a 14 L spherical vessel with central ignition at ambient initial conditions. The LBVs were calculated from p(t) data, determined in accordance with EN 15967, by using only the early stage of flame propagation. The results show that hydrogen addition determines an increase in LBV for all examined binary flammable mixtures. The LBV variation versus the fraction of added hydrogen, rH, follows a linear trend only at moderate hydrogen fractions. The further increase in rH results in a stronger variation in LBV, as shown by both experimental and computed LBVs. Hydrogen addition significantly changes the thermal diffusivity of flammable CH4–air or NG–air mixtures, the rate of heat release, and the concentration of active radical species in the flame front and contribute, thus, to LBV variation.
For hazard assessment purposes, the dispersion of gases in complex urban areas is often a scenario to be considered. However, predicting the dispersion of heavy gases is still a challenge. In Germany, the VDI Guideline 3783, Part 1 and 2 is widely used for gas dispersion modelling. Whilst Part 1 uses a gauss model for calculating the dispersion of light or neutrally buoyant gases, Part 2 uses wind tunnel experiments to evaluate the heavier-than-air gas dispersion in generic built up areas. In practice, with this guideline, it is often not possible to adequately represent the existing obstacle configuration. To overcome this limitation, computational fluid dynamics (CFD) methods could be used. Whilst CFD models can represent obstacles in the dispersion area correctly, actual publications show that there is still further research needed to simulate the atmospheric flow and the heavy gas dispersion. This paper presents a modified k-ε-turbulence model that was developed in OpenFOAM v5.0 (England, London, The OpenFOAM Foundation Ltd Incorporated) to enhance the simulation of the atmospheric wind field and the heavy gas dispersion in built-up areas. Wind tunnel measurements for the dispersion of neutrally buoyant and heavy gases in built-up environments were used to evaluate the model. As a result, requirements for the simulation of the gas dispersion under atmospheric conditions have been identified and the model showed an overall good performance in predicting the experimental values.
Major accidents in the process industry often lead to the release of light or dense gases, which can mean a thread to employees, local residents or to the environment. Possible scenarios are therefore analyzed and evaluated in advance for approval issues. There is a trend, where simple empirical models are being replaced with more complex numerical models. Gaussian dispersion models or models based on dimensional analysis approaches are for example, increasingly replaced by CFD simulations. The main reason for this is the potentially higher accuracy. However, usually scenarios using sharp parameter values are calculated, since comprehensive consideration of parameter distributions via Monte Carlo or Latin Hypercube Sampling fails due to the numerical effort. This includes the risk that the influence of uncertainties on the simulation results is not taken into account. Response surface methods offer an alternative, with which the CFD problem can be mapped onto an algebraic surrogate model. If this is sufficiently precise, parameter sampling can also be carried out with the surrogate as well, as shown in some publications. Previous investigations only demonstrated the basic principle using trivial dispersion models. In this paper two realistic CFD simulations from the plant safety area are considered: VOC emissions from a storage tank and near-ground dense gas emissions. The entire procedure of response surface determination and parameter studies was automated and parallelized for high-performance-computing, and is carried out on the underlying CFD grids. For the CFD simulations as well as for all visualizations, the commercial software ANSYS CFX and the open source software OpenFOAM were used. The aim of this paper is to demonstrate the method using industry-relevant applications as well as to show how this can be used in practical engineering applications. The quality of surrogate modeling, the numerical effort and advantages that can result from the procedure are discussed as well as advantages which may result from taking parameter uncertainties into account in safety studies.
The hybrid mixture of combustible dusts and flammable gases/vapours widely exist in various industries, including mining, petrochemical, metallurgical, textile and pharmaceutical. It may pose a higher explosion risk than gas/vapor or dust/mist explosions since the hybrid explosions can still be initiated even though both the gas and the dust concentration are lower than their lower explosion limit (LEL) values. Understanding the explosion threat of hybrid mixtures not only contributes to the inherent safety and sustainability of industrial process design, but promotes the efficiency of loss prevention and mitigation. To date, however, there is no test standard with reliable explosion criteria available to determine the safety parameters of all types of hybrid mixture explosions, nor the flame propagation and quenching mechanism or theoretical explanation behind these parameters. This review presents a state-of-the-art overview of the comprehensive understanding of hybrid mixture explosions mainly in an experimental study level; thereby, the main limitations and challenges to be faced are explored. The discussed main contents include the experimental measurement for the safety parameters of hybrid mixtures (i.e., explosion sensitivity and severity parameters) via typical test apparatuses, explosion regime and criterion of hybrid mixtures, the detailed flame propagation/quenching characteristics behind the explosion severities/sensitivities of hybrid mixtures. This work aims to summarize the essential basics of experimental studies, and to provide the perspectives based on the current research gaps to understand the explosion hazards of hybrid mixtures in-depth.