1.8 Umweltanalytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (87)
- Vortrag (76)
- Posterpräsentation (61)
- Sonstiges (7)
- Beitrag zu einem Tagungsband (3)
- Dissertation (2)
- Forschungsdatensatz (2)
- Buchkapitel (1)
Sprache
- Englisch (202)
- Deutsch (35)
- Mehrsprachig (2)
Schlagworte
- Immunoassay (52)
- ELISA (23)
- Diclofenac (19)
- Amoxicillin (16)
- Antikörper (13)
- Biosensor (13)
- Amperometry (12)
- Biosensoren (12)
- Antibody (9)
- Warfarin (9)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (239)
- 1.8 Umweltanalytik (239)
- 1.7 Organische Spuren- und Lebensmittelanalytik (30)
- 1.1 Anorganische Spurenanalytik (26)
- 6 Materialchemie (19)
- 4 Material und Umwelt (14)
- 1.5 Proteinanalytik (13)
- 1.4 Prozessanalytik (12)
- 1.9 Chemische und optische Sensorik (12)
- 6.1 Oberflächen- und Dünnschichtanalyse (10)
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (76)
A frequently studied environmental contaminant is the active substance diclofenac, which is removed insufficiently in sewage treatment plants. Since its inclusion in the watch list of the EU Water Framework Directive, the concentrations in surface waters will be determined throughout Europe. For this, still, more precise analytical methods are needed. As a reference, HPLC-MS is frequently employed. One of the major metabolites is 4’-hydroxydiclofenac (4’-OH-DCF). Also, diclofenac lactam is important for assessing degradation and transformation. Aceclofenac (ACF), the glycolic acid ester of diclofenac is used as a drug, too, and could potentially be cleaved to yield diclofenac again. In various sewage treatment plant influent samples, diclofenac, 4’-OH-DCF, DCF lactam and ACF could be determined with detection limits of 3 µg/L, 0.2 µg/L, 0.17 µg/L and 10 ng/L, respectively.
Several works evaluated the toxicity of pharmaceutical drugs and climate related changes in invertebrates but few explored the combined effects of both stressors, namely considering their mode of action (MoA). Carbamazepine (CBZ) and cetirizine (CTZ) are pharmaceutical drugs detected in the environment and the toxicity derived from the combined effects of these drugs with ocean acidification (OA) is poorly explored. Thus, the present study investigated the biochemical parameters related to an oxidative stress response and the transcription of genes related to the MoA of CBZ (1.0 mg/L) and CTZ (0.6 mg/L) in the clam Ruditapes philippinarum chronically exposed (28 days) to control (7.8) and low (7.5) pH conditions. The results obtained showed that despite the clams accumulated both drugs, at low pH the clams exposed to CTZ decreased drug concentration and BCF values (CTZ uptake: 2.0 ± 0.5 ng/g fresh weight; BCF: 3.8 ± 0.9) in comparison with clams exposed to control pH (CTZ uptake: 2.9 ± 0.3 ng/g fresh weight; BCF: 5.5 ± 0.6). No oxidative stress was induced by the exposure to CBZ or CTZ at each pH level, but the transcription of several genes related with the MoA (neurotransmission, immunity and biomineralization) was altered by low pH, drug exposure and the combination of both stressors. At both pH conditions, CBZ increased the transcription of GABA receptor gene (neurotransmission) and CTZ led to a decrease of Perlucin gene (biomineralization) transcription. The transcription of MyD88 gene (immunity) decreased at low pH (7.5) combined with drug exposure (CBZ or CTZ). Thus, it was highlighted that the interaction of drug exposure and low pH conditions can change bivalves’ sensitivity to drugs or alter drugs toxicity.
Im Beitrag wurden Ergebnisse von Elutionsuntersuchungen mit PFC kontaminierten Bodenmaterialien vorgestellt. Zum einen waren das Untersuchungen zur Eignung von Säulenversuchen für diese Schadstoffgruppe und zum anderen vergleichende Schüttel- und Säulenversuche für zwei verschiedene Böden mit unterschiedlichen PFC-Kontaminationsquellen.
Equipping ZIF particles with a polyelectrolyte membrane provides functional groups at their interface, enabling further conjugations necessary for applications such as targeted drug delivery. Previous approaches to coat ZIF particles with polyelectrolytes led to surface corrosion of the template material. This work overcomes previous limitations by performing a Layer-by-Layer (LbL) polyelectrolyte coating onto ZIF-8 and ZIF-67 particles in nonaqueous environment. Using the 2-methylimidazolium salt of polystyrensulfonic acid instead of the acid itself and polyethyleneimine in methanol led to intact ZIF particles after polyelectrolyte coating. This was verified by electron microscopy. Further, zetapotential and atomic force microscopy measurements confirmed a continuous polyelectrolyte multilayer built up. The here reported adaption to the well-studied (LbL) polyelectrolyte selfassembly process provides a facile method to equip ZIF particles with a nanometer thin polyelectrolyte multilayer membrane.
Cost-effective water cleaning approaches using improved Treatment technologies, for instance based on catalytic processes with high activity catalysts, are urgently needed. The aim of our study was to synthesize efficient Fenton-like photo-catalysts for rapid degradation of persistent organic micropollutants in aqueous medium. Iron-based nanomaterials were chemically synthesized through simple procedures by immobilization of either iron(II) oxalate (FeO) or iron(III) citrate (FeC) on magnetite (M) nanoparticles stabilized with polyethylene glycol (PEG). Various investigation techniques were performed in order to characterize the freshly prepared catalysts. By applying advanced oxidation processes, the effect of catalyst dosage, hydrogen peroxide concentration and UV-A light exposure were examined for Bisphenol A (BPA) conversion, at laboratory scale, in mild conditions. The obtained results revealed that BPA degradation was rapidly enhanced in the presence of low-concentration H2O2, as well as under UV-A light, and is highly dependent on the surface characteristics of the catalyst. Complete photo-degradation of BPA was achieved over the M/PEG/FeO catalyst in less than 15 minutes. Based on the catalytic performance, a hierarchy of the tested catalysts was established: M/PEG/FeO > M/PEG/FeC > M/PEG. The results of cytotoxicity assay using MCF-7 cells indicated that the aqueous samples after treatment are less cytotoxic.
Monitoring water quality regarding emerging pollutants, such as drug residues, demands for selective, high-throughput and multi-target analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affinity and specificity of target recognition by antibodies. Batch-wise processing in microtiter plates allows for the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex Suspension Array Fluorescence Immunoassay (SAFIA), which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core silica-shell microparticles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica shell creates a solid-support for the immunoassay: the target analytes, three drugs, carbamazepine, diclofenac and caffeine, and the fecal marker isolithocholic acid are covalently coupled to amino groups on the surface via NHS chemistry. Specific recognition of these haptens is accomplished by further introduction of PEG moieties, suppressing non-specific binding. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure, eliminating the demand for laborious washing steps and decreasing time-to-result. An automated flow cytometer is used for simultaneous decoding and quantification.
After optimization, the SAFIA showed limits of detection for all analytes in the low µg L 1 range, meeting the sensitivity criteria for wastewater analysis. Then, applicability of the SAFIA was studied on real wastewater samples from three different wastewater treatment plants in Berlin. The results were in good comparability to LC-MS/MS indicating high matrix stability. Moreover, the accuracy of the assay exceeded that of the respective ELISA. Finally, we used SAFIA to assess the influent of treated and untreated wastewater on the Douro river estuary in Portugal. The obtained results of the analysis were comparable to ELISA. However, the measurements by SAFIA could be carried out in one quarter the time of analysis required for ELISA.
Acknowledgements: The authors acknowledge financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16, DAAD Zuwendungsvertrag 57212899).
The improvement of immunoanalytical methods for the determination of pharmaceuticals in wastewaters is a crucial yet challenging endeavor. In this work, the development of an automated miniaturized ELISA based on micro-Bead Injection Spectroscopy (μ-BIS) [1] for the determination of carbamazepine, a widely employed anti-epileptic drug and emergent pollutant [2], was pursued.
The experimental workflow comprised the offline functionalization of Sepharose beads with specific anti-CBZ antibodies via affinity immobilization using protein G, and 3 online steps inside the microfluidic analyzer lab-on-valve (LOV): I) packing of the bead column into the detection unit; II) sequential percolation of sample and a CBZ competitor- labeled with horseradish peroxidase (tracer) through the bead column; and III) on-column colorimetric detection employing the enzyme substrate 3,3’,5,5’-tetramethylbenzidine. After each analysis, the bead column was discarded, and the flow cell was washed before receiving new beads.
The elimination of manual washing steps is a novel feature compared to batch-wise ELISA, making the method less error-prone and therefore more robust. The replacement of the solid support prevents memory effects and cross-contamination between runs. The use of microparticles as solid support for the molecular recognition elements accounts for high area-to-volume ratios, and low molecular diffusion distances. For that reason, time-to-result was reduced from several hours to less than 10 min. The consumption of reagents was also very low. For instance, only ca. 200 μg of solid support and 900 ng of anti-CBZ antibody were required per determination. At last, the versatility of the LOV platform offers the possibility of adapting the assay to other relevant pharmaceuticals and anthropogenic markers in water.
Acknowledgements: Inês I. Ramos thanks FCT (Fundação para a Ciência e a Tecnologia) and POPH (Programa Operacional Potencial Humano) for her grant (SFRH/BD/97540/2013). This work received financial support from the European Union (FEDER funds POCI/01/0145/FEDER/007265) and National Funds (FCT/MEC - Ministério da Educação e Ciência) under the Partnership Agreement PT2020 UID/QUI/50006/2013. Financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16) is also acknowledged.
[1] Gutzman, Y.; Carrol, A. D. Analyst 2006, 131, 809.
[2] Murray, K. E.; Thomas, S. M.; Bodour, A. A. Environ. Pollut. 2010, 158, 3462.
The main goal of the study was to evaluate the catalytic activity of two hybrid nanocatalysts consisting in Fe3O4 nanoparticles modified with either chitosan (CS) or polyethylene glycol (PEG)/ferrous oxalate (FO), and further deposited on solid substrate as thin films. X-ray powder diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, and scanning electron microscopy (SEM) were employed for the structural and morphological characterizations of the heterogeneous catalysts. The Degradation kinetic studies of two reactive azo dye (Reactive Black 5 (RB5) and Reactive Yellow 84 (RY84)) as well as Bisphenol A (BPA) solutions were carried out using Fenton-like oxidation, in the presence of different concentrations of H2O2, at initial near-neutral pH and room temperature. The results indicated that a low amount of catalytic material (0.15 g/L), deposited as thin film, was able to efficiently trigger dye degradation in solution in the presence of 6.5mmol/LH2O2 for RB5 and of only 1.6mmol/LH2O2 in the case of BPA and RY84. In the presence of complex matrices such asWWTP waters, the removal of BPAwas low (only 24% for effluent samples). Our findings recommend the studied immobilized nanocatalysts as promising economical tools for the pretreatment of wastewaters using advanced oxidation processes (AOPs).
IAPR participates in the EMPIR 16SRT02, entitled ‘Certified forensic alcohol reference materials - ALCOREF’ funded by EURAMET as an external funded partner. The Research in this project will address the needs for better enforcement of drink-driving legislation in several European countries, by building up long-term capacities for the production and certification of forensic alcohol reference materials, suitable for the calibration of evidential breath alcohol analyzers. The certification procedure includes characterization of the materials, assessment of homogeneity, stability, and uncertainty estimation. An interlaboratory comparison will be conducted to test the materials and capabilities developed. EMPIR 16SRT02-ALCOREF project is coordinated by BAM (DE).
The impact of nanoparticles, NPs, at the single cell level has become a major field of toxicological research and different analytical methodologies are being investigated to obtain biological and toxicological information to better understand the mechanisms of cell–NP interactions. Here, inductively coupled plasma mass spectrometry in the single cell measurement mode (SC-ICP-MS) is proposed to study the uptake of silver NPs, AgNPs, with a diameter of 50 nm by human THP-1 monocytes in a proof-ofprinciple experiment. The main operating parameters of SC-ICP-MS have been optimized and applied for subsequent quantitative analysis of AgNPs to determine the number of particles in individual cells using AgNP suspensions for calibration. THP-1 cells were incubated with AgNP suspensions with concentrations of 0.1 and 1 µg/mL for 4 and 24 hours. The results reveal that the AgNP uptake by THP-1 monocytes is minimal at the lower dose of 0.1 µg/mL (roughly 1 AgNP per cell was determined), whereas a large cell-to-cell variance dependent on the exposure time is observed for a 10 times higher concentration (roughly 7 AgNPs per cell). The method was further applied to monitor the AgNP uptake by THP-1 cells differentiated macrophages incubated at the same AgNP concentration levels and exposure times demonstrating a much higher AgNP uptake (roughly from 9 to 45 AgNPs per cell) that was dependent on exposure concentration and remained constant over time. The results have been compared and validated by sample digestion followed by ICP-MS analysis as well as with other alternative promising techniques providing single cell analysis.