A vast number of emerging pollutants has been detected in the environment over the last decades. Analytical methods suitable for trace analysis are needed that are desirably also fast, inexpensive and, if possible, robust and portable. Immunoanalytical, i.e. antibody-based, methods which are available in a broad range of formats, can be profitably used here to analyse for the distribution and the trends of concentration levels of contaminants in the environment. Some of these formats are single-analyte but high-throughput methods. In order to use them wisely, indicator substances, sometimes called anthropogenic markers, should be selected and used in screening approaches. Other methods are suitable to be performed on portable instrumentation in the field (on-site) or in facilities such as wastewater treatment plants for on-line monitoring. Furthermore, there are array technologies that allow for parallel (multiplex) analysis of several analytes of interest.
The microtiter-plate based ELISA (Enzyme-linked Immunosorbent Assay) is the method of choice for the analysis of a large number of samples [1]. ELISAs are available to monitor for anthropogenic markers such as the antiepileptic carbamazepine, the analgesic diclofenac, the antihistaminic cetirizine, the steroid hormone estrone, the antimicrobial sulfamethoxazole, the stimulants caffeine and cocaine, the priority pollutant bisphenol A, and the bile acid isolithocholic acid. For on-site screening and monitoring, simpler formats, like mix-and-read assays, e.g. the Fluorescence Polarization Immunoassay (FPIA) [2] or Lateral-flow Immunoassays (LFIA) [3] are more suitable tools, the latter based on dipsticks or cassettes, that is why they are also called pregnancy test-like assays. The suitability of multi-analyte formats such as immunomicroarrays depends on the choice of a signal-producing system that provides small uncertainties and good reproducibility of the measurements. Bead-based (“suspension”) arrays read out in flow cytometers are a powerful platform for multiplex assays [4]. Electrochemical formats run on portable devices provide additional advantages as no light source is required. They are most promising for stand-alone analysers and biosensors
A vast number of emerging pollutants is being detected in the environment. Another lingering problem are health-threatening contaminants, such as mycotoxins, that deteriorate food and feed.
Analytical methods, suitable for trace analysis, are needed that are desirably also fast, inexpensive and, if possible, robust, and portable. Immunoanalytical, i.e., antibody-based methods, which are available in a broad range of formats, can be profitably used here to analyze for the distribution and the concen-tration trends of contaminants.
Some of these formats are single-analyte but high-throughput methods. To use them wisely, indicator substances or sum parameters are being established and used in screening approaches. Other methods are suitable to be performed on portable instrumentation in the field (on-site), more precisely at the point-of-need. Furthermore, there are array technologies that allow for parallel analysis of several analytes of interest (multiplexing).
The talk reports on methods and data for compounds considered as anthropogenic contamination markers (the antiepileptic carbamazepine, the analgesic diclofenac, the anti-histaminic cetirizine, the steroid hormone estrone, the antimicrobial amoxicillin, the stimulants caffeine and cocaine, the endo-crine disruptor bisphenol A, and a bile acid). Some work on mycotoxins (ochratoxin A and ergot alka-loids) is also presented. It is demonstrated that antibody-based approaches have a huge potential to gain analytical insights at the point-of-need.
Antibody-based analytical techniques have gained increasing importance in environmental analysis. Rapid assays, portable devices and formats that require a limited number of steps have a high potential for on-site analysis in outdoor environments or in environmentally relevant facilities such as wastewater treatment plants. Many of these methods have become more sensitive and more versatile due to new, advanced materials, such as novel particles, specifically prepared surfaces, new labels, specifically coated electrodes etc. The talk shows some of our works in this context.
A vast number of emerging pollutants is being detected in the environment. Another lingering problem are health-threatening contaminants, such as mycotoxins, that deteriorate food and feed.
Analytical methods, suitable for trace analysis, are needed that are desirably also fast, inexpensive and, if possible, robust, and portable. Immunoanalytical, i.e., anti-body-based technologies, which are available in a broad range of formats, can be profitably used here to analyze for the distribution and the concentration trends of contaminants.
Some of these formats are single-analyte but high-throughput methods. To use them wisely, indicator substances or sum parameters must be established to be used in screening approaches. Other methods are suitable to be performed on portable in-strumentation in the field (on-site), more precisely at the point-of-need. Furthermore, there are array technologies that allow for parallel analysis of several analytes of interest (multiplexing). The talk reports on methods and data for compounds con-sidered as anthropogenic contamination markers (the antiepileptic carbamazepine, the analgesic diclofenac, the anti-histaminic cetirizine, the steroid hormone estrone, the antimicrobial amoxicillin, the stimulants caffeine and cocaine, the endocrine disruptor bisphenol A, and a bile acid). Some work on mycotoxins (ochratoxin A and ergot alkaloids) is also presented. It is demonstrated that antibody-based technolo-gies have a huge potential to gain analytical insights at the point-of-need.
Polyethylene glycols (PEGs) are widely used in everyday items such as food additives and in personal care products. In addition, they have multiple medical applications: as laxatives, excipients, and covalently coupled to drug molecules leading to improved pharmacokinetics (PEGylation). While generally regarded as biologically inert, the human body is known to produce antibodies against PEGylated molecules. In addition, PEGs have been shown to be part of a biomarker signature to predict colon cancer outcome, suggesting a more complex and yet unknown behavior of PEGs in the human body.
Here, we introduce PEGomics, a retrospective screening approach of publicly available LC-MS data. Using a custom R script to process entire studies, the presence of PEGs was reveled in most human plasma, serum and whole blood samples investigated. Several PEG species and adducts were identified and their correlation with different diseases and health conditions was investigated further.
Blood PEG levels significantly differed between patient groups in multiple clinical studies related to e.g. pregnancy duration, fasting and smoking. We discuss possible causes for these effects in the light of recent reports of allergies against PEGs and outline our further strategies to identify the source of PEGs in the human body as well as possible metabolic transformations.
Metrology for Monitoring of Endocrine Disrupting Chemicals Under the EU Water Framework Directive
(2021)
Monitoring programs should generate high-quality data on the concentrations of substances and other pollutants in the aquatic environment to enable reliable risk assessment. Furthermore, the need for comparability over space and time is critical for analysis of trends and evaluation of restoration of natural environment. Additionally, research work and exercises at the European level have highlighted that reliable measurements of estrogenic substances especially three estrogens of the first watch list (17-beta-estradiol (17βE2), 17-alpha-ethinylestradiol (EE2), and estrone (E1))at the PNEC level are still challenging to achieve.With respects to their physicochemical properties, the 3 substances have the potential to disseminate within aquatic environments, to enter the food chain and to bioaccumulate, Chemical monitoring relies on a succession of actions: sampling, storage and preservation of representative samples; pre-treatment of a sample portion for quantification, calibration, final determination, calculation of results, uncertainty estimation and final expression of results. Throughout this chain of operations, the guarantee of the stability of the analyte is a key issue that has to be addressed to correctly qualify and discuss monitoring data.
The project EDC-WFD aims to develop traceable analytical methods for determining endocrine disrupting compounds and their effects, with a specific focus on three estrogens of the first watch. Environmental quality standards (EQS) for these compounds are at the ultra-trace level (EQS EE2 = 35 pg/L, EQS E2 = 400 pg/L, EQS E1 = 3600 pg/L) and pose a significant challenge to analytical methods. Estrogens 17-alpha-estradiol (17αE2) and estriol (E3) will be included to demonstrate the reliability of the developed methods and to support the requirements of Directive 2013/39/EC, Directive 2009/90/EC and Commission Implementation Decision (EU) 2018/840, hence improving the comparability and compatibility of measurement results within Europe. The project will also evaluate the interaction and partitioning of the 5 estrogenic compounds between water samples and suspended particulate matter (SPM) and the capability of developed methods to address the different fractions of matrix (whole water and dissolved concentrations of estrogens).
This contribution will present the objectives and methods applied within the EDC-WFD project that could support a better comprehension of the biogeochemical cycle of selected estrogenic substances in aquatic system
Funding: This project (18NMR01) has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme
Herein, we present liquid and gas chromatographic methods coupled with
(high-resolution) mass spectrometry for the analysis of warfarin’s TPs.
Methodologies such as UV-irradiation, ozonation, and chlorination were
utilized to simulate primarily technical water treatment, as well as, abiotic transformation processes. Examination of resulting compounds by numerous analytical methods has provided first insights into a multitude of formed substances. Moreover, the oxidative phase I metabolism was mimicked by an electrochemical flow cell with the aim to synthesize and confirm major metabolic products via a nonbiologically mediated process. The further aim is the toxicological assessment of relevant TPs, as well as, the quantification of warfarin and its TPs under environmentally relevant conditions employing the introduced methodologies.
Sediments and soils can act as sinks of species of inorganic mercury (Hg2+), while they are simultaneously sources of volatile (Hg0) and organic species, such as monomethylmercury (MMHg). Although the fraction of MMHg in total Hg of sediments is suggested to be as low as 0.1 1%, MMHg is a serious threat for humans and wildlife due to its high potential for bioaccumulation and biomagnification and the ability to pass the blood-brain barrier. This is highlighted by exceptionally high MMHg concentrations found in fish and fish predators, as well as aquatic insects and birds living in close vicinity to Hg contaminated waterbodies. Humans are exposed to MMHg mainly by ingestion of (predatory) fish and rice.
One example of a highly Hg contaminated waterbody is Finow Canal, the oldest artificial waterway still in operation in Germany, with Hg mass fractions of up to or even more than 100 µg/g found in the sediment, which are suggested to be attributable to a chemical plant producing (among other things) mercury-based seed dressings. Despite this high mass fraction of Hg, anaerobic conditions, high amounts of organic matter and iron, which are all favorable for Hg methylation, no investigations of Hg speciation have been conducted there up to now.
We investigated Hg speciation in sediments of Finow Canal on length from before the known polluted sited into the confluence with another waterway using species-specific isotope dilution (SSID) GC-ICP-ToF-MS. Mass fraction of up to 41 ng/g MMHg were determined in samples taken from Finow Canal and elevated concentrations could also be found around 14 km downstream of the confluence of Finow Canal with another waterway. In addition to this, highly toxic monoethylmercury (EtHg) could be detected in most of the sediment samples. These results are the first evidence of the occurrence of MMHg in this region and show the need for further investigation of the whole regional ecosystem, as well as the consideration of possible measures of remediation.
The presentation provides an overview of the EMPIR project ALCOREF “Certified forensic alcohol reference materials”. Results of an EURAMET intercomparison of ethanol in water reference materials developed in the project are presented, and two different statistical models for the key comparison reference function are discussed, the Frequentist approach and a Bayesian approach.
How to trace the "cereal" killer? Fungal secondary metabolites, aka mycotoxins, pose a severe health risk for humans and animals. Since their occurrence in food, such as cereal products, is inevitable, the detection is of considerable importance. I want to demonstrate how the trace analysis of mycotoxins in foodstuff can be performed outside the laboratory. For this purpose, sensitive, antibody-based methods are combined with electrochemical smartphone-based detection.
The presentation summarizes the results of the EURAMET key comparison QM-S13 “Comparison of value assigned forensic alcohol in water reference materials”. Possible options for the key comparison reference function (KCRF) are discussed: the frequentist approach and a Bayesian approach. Both methods are used to determine the degrees of equivalence of materials and participants.
The presentation summarizes the results of the EURAMET key comparison QM-S14 “Measurement capabilities for the quantification of ethanol in water”. Possible options for the key comparison reference value (KCRV) are discussed. A Bayesian approach is finally used to estimate the KCRV and the degrees of equivalence of participants.
We present the development of magnetic bead-based immunoassays for two potential contaminants of drinking water: the nonsteroidal anti-inflammatory drug diclofenac and the broad-spectrum antibiotic amoxicillin. For these analytes, different assay formats were developed which can generally be transferred to other analytes. The use of magnetic beads not only enables implementation of the assays into an online system since the beads can be reversibly immobilized by applying a magnetic field. Furthermore, our MBBAs hold several advantages over the conventional ELISAs (enzyme-linked immunosorbent assays) for both analytes, such as lower limits of quantification, shorter assay duration and less washing steps required.
Strategies for the setup and miniaturization of an online immunosensor including electrochemical readout on a microfluidic chip will be discussed.
Immunomagnetic ochratoxin a assay with electrochemical 3,3′,5,5′ tetramethylbenzidine detection
(2021)
The demand for miniaturized analytical devices monitoring important parameters in the food and medical industry has increased strongly in the past decades. With fast progress, smart technologies are finding their way into our everyday life. For the future, it is, therefore, a major goal to also link analytical methods with smart technologies to create user-friendly on-site devices. In food industry the monitoring of harmful substances such as dioxins, heavy metals or mycotoxins plays a key role, since the European Commission prescribes legal limits for various food products and beverages[1]. Therefore, companies often have their own laboratories and trained personnel. For one of the most abundant and toxic mycotoxins, Ochratoxin A (OTA) we want to present an electrochemical detection system in which the read-out can be performed with a smartphone connected via Bluetooth to a miniaturized potentiostat. The recognition of OTA is performed with specific antibodies in a competitive assay format. Anti-OTA-antibodies were captured on magnetic beads on which the competitive binding between OTA and an OTA horseradish peroxidase (HRP) tracer was performed. To quantify OTA, the enzymatic reaction of the tracer with 3,3′,5,5′-tetramethylbenzidine (TMB) and H2O2 is employed. Oxidized TMB, which is enzymatically produced by the reduction of H2O2, is quantified by amperometry with screen-printed electrodes in a custom-made flow system. The results of the electrochemical detection method are in good correlation with the photometric detection of TMB. To demonstrate the applicability, we tested our system with OTA-spiked beer and performed the measurement via smartphone.
Parkinson’s disease (PD) is one of the most common neurodegenerative disorders worldwide. About 0.3 % of the global population and approximately 2 % of people older than 80 years are affected by PD. Monoamine oxidase B (Mao B) is an enzyme, which is a drug target in Parkinson’s disease (PD), since it is involved in dopamine metabolism. Several Mao B inhibitors are well established as medication for PD patients. However, the medical treatment is only little personalized since the monitoring of the patients Mao B activity is complex and requires sophisticated laboratory equipment. Here a sensorial Mao B activity determination system has been developed which has potential in the personalization of the medical PD treatment. The enzyme activity is quantified by amperometric detection of enzymatically produced H2O2. Therefore, the enzyme is enriched from the solution via cellulose particles which are functionalized with antibodies against human Mao B. The successful capturing of the enzyme can be verified by SDS-PAGE. For activity determination the enzyme is brought in contact with a suitable substrate - here benzylamine. Selectivity of the amperometric hydrogen peroxide detection in the presence of co-reactants has been verified. Within the time span of 30 min, a linear dependency of enzymatically produced H2O2 with the substrate incubation time can be observed. This allows the evaluation of the Mao B activity. The results have been correlated to an optical detection method. Furthermore, the method has been tested for different amounts of enzyme used in the experiments and found to be sensitive enough for Mao B analysis in blood samples.