1.6 Anorganische Referenzmaterialien
Filtern
Dokumenttyp
- Vortrag (60)
- Zeitschriftenartikel (31)
- Posterpräsentation (24)
- Dissertation (1)
- Newsletter (1)
- Sonstiges (1)
Schlagworte
- HR-CS-MAS (17)
- Isotope analysis (11)
- Lithium (10)
- GD-OES (9)
- Machine learning (9)
- CRM (8)
- Isotope (8)
- Lithium Ion Batteries (8)
- Optical spectroscopy (8)
- Isotopes (7)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (118)
- 1.6 Anorganische Referenzmaterialien (118)
- 1.1 Anorganische Spurenanalytik (19)
- P Präsident (15)
- P.0 Präsident und andere (15)
- S Qualitätsinfrastruktur (9)
- S.1 Qualität im Prüfwesen (9)
- 1.3 Instrumentelle Analytik (7)
- 1.7 Organische Spuren- und Lebensmittelanalytik (7)
- 3 Gefahrgutumschließungen; Energiespeicher (6)
Paper des Monats
- ja (1)
Die Vorgehensweise bei der Zertifizierung von Referenzmaterialien in der BAM entsprechend den Regeln des ISO-Guide 35 wird an Beispielen beschrieben. Darüber hinaus wird ein umfassender Überblick über Referenzmaterialien zur Analyse der Nichtmetalle Sauerstoff, Wasserstoff, Stickstoff, Kohle und Schwefel gegeben.
The mechanism of action of zirconium permanent modifiers on graphite surfaces was investigated in order to understand its influence on the analytical signal in atomic and molecular absorption spectrometry (AAS/MAS). For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEMEDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. We propose here a mechanism, where ZrO2 acts as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface. No evidence of the formation of zirconium carbide was found. Consequently, as the CaF formation is catalysed by a heterogeneous catalyst, surface modifications with ZrO2 nanoparticles and ZrO xerogels were investigated in order to increase the surface area. Their influence was evaluated in the molecule formation of CaF, CaCl, CaBr, and CaI. Graphite furnace modification with zirconium oxide nanoparticles proves to be the best choice for fluorine analysis with a signal enhancement of more than eleven times with respect a non-coated graphite furnace. However, the influence of zirconium modifications in the analytical signals of Cl, and I is lower than the F signals or even negative in case of the Br. Understanding zirconium modifiers as heterogeneous catalysts offers a new perspective to AAS and MAS, and reveals the potential of surface analytical methods for development of improved permanent modifiers and graphite furnace coatings.
Aging Mechanisms of Lithium Batteries: How can we make batteries more durable and more sustainable in the future?
Lithium batteries are particularly susceptible to ageing processes. During each charging and discharging process in an electric battery, lithium ions are deposited in the electrodes of the cell like in the pores of a sponge. Over time, however, fractures and cracks occur in the filigree structures. The result: more and more lithium ions no longer fit into the hollow spaces of the „sponge“, instead they accumulate in heaps around the electrodes and hinder the movement of other ions. The performance of the battery decreases.
We present our new project, in which we are developing a fast and cost-effective method with which companies that produce lithium batteries can already assess the ageing behaviour of their batteries in the laboratory.
What does GD-OES reveal about the aging and manufacturing processes of lithium-ion batteries?
(2024)
Glow-Discharge Optical Emission Spectroscopy (GD-OES), a powerful analytical technique, sheds light on the two critical aspects of lithium-ion batteries (LIBs): manufacturing and aging 1, 2. We optimized cell production in manufacturing by adjusting parameters, including cathode doping, electrolyte concentration, and pressing force. GD-OES provided in-depth elemental composition and homogeneity analysis, which is crucial for identifying optimal manufacturing conditions. These findings were validated by electrochemical impedance spectroscopy, confirming the quality of the manufactured batteries.
Shifting the focus to aging, we use GD-OES for fluorine depth profiling, a key element in understanding polymer and electrolyte degradation. However, fluorine presents analytical challenges. We addressed this by substituting argon with a neon:argon mixture, which significantly enhanced fluorine detection sensitivity. This advancement not only improves accuracy but also holds the potential to guide sustainable and cost-efficient manufacturing strategies.
Through its versatility, GD-OES has proven to be a powerful tool for not only optimizing LIB manufacturing processes but also gaining deeper insights into their aging mechanisms. This research extends beyond academic interest, offering tangible benefits for the industry by translating into improved battery quality, extended lifespan, and overall performance.
For more than 110 years, BAM has been producing reference materials for a wide range of application fields. With the development of new analytical methods and new applications as well as continuously emerging more stringent requirements of laboratory accreditation with regard to quality control and metrological traceability, the demand and requirements for reference materials are increasing. This trend article gives an overview of general developments in the field of reference materials as well as developments in selected fields of application in which BAM is active. This includes inorganic and metal analysis, gas analysis, food and consumer products, and geological samples. In addition to these more traditional fields of application, developments in the areas of optical spectroscopy, particulary fluorescence methods, and nanomaterials are considered.
Glow discharge optical emission spectroscopy (GD-OES) is a technique for the analysis of solids such as metals, semiconductors, and ceramics. A low-pressure glow discharge plasma is applied in this system, which ‘sputters’ and promotes the sample atoms to a higher energy state. When the atoms return to their ground state, they emit light with characteristic wavelengths, which a spectrometer can detect. Thus, GD-OES combines the advantages of ICP-OES with solid sampling techniques, which enables it to determine the bulk elemental composition and depth profiles. However, direct solid sampling methods such as glow-discharge spectroscopy require reference materials for calibration due to the strong matrix effect.
Reference materials are essential when the accuracy and reliability of measurement results need to be guaranteed to generate confidence in the analysis. These materials are frequently used to determine measurement uncertainty, validate methods, suitability testing, and quality assurance. In addition, they guarantee that measurement results can be compared to recognized reference values. Unfortunately, the availability of certified reference materials suited to calibrate all elements in different matrix materials is limited. Therefore various calibration strategies and the preparation of traceable matrix-matched calibration standards will be discussed.
Machine learning is an essential component of the growing field of data science. Through statistical methods, algorithms are trained to make classifications or predictions, uncovering key insights within data mining projects. Therefore, it was tried in our work to combine GD-OES with machine learning strategies to establish a new and robust calibration model, which can be used to identify the elemental composition and concentration of metals from a single spectrum. For this purpose, copper reference materials from different manufacturers, which contain various impurity elements, were investigated using GD-OES. The obtained spectra information are evaluated with different algorithms (e.g., gradient boosting and artificial neural networks), and the results are compared and discussed in detail.
Reference materials are essential, when the accuracy and reliability of measurement results need to be guaranteed in order to generate confidence in the analysis.
These materials are frequently used for determining measurement uncertainty, for validation of methods, suitability testing and quality assurance. Especially direct solid sampling methods require reference materials for calibration.
They guarantee that measurement results can be compared to recognized reference values.
This presentation gives an overview about the use of GDMS in various certification procedures. Because it represents a fast, sensitive, multielement analyses technique without extensive sample preparation it plays a special role for the purity determination of high purity standards. Various calibration strategies and the preparation of traceable matrix matched calibration standards will be discussed.
For the certification of analyte content in matrix materials mainly techniques with solvent sample preparation are used. Here GD-MS is used to identify possible loss or contamination with analytes during the sample preparation step. Typically used acids to dissolve matrices lead to interferences in the ICP- mass spectrometric detection of various analytes and their quantification. Here GD-MS as direct method can also add an important contribution in the certification process.
Wie lässt sich die Herkunft von Rohstoffen, Lebensmitteln oder Umweltschadstoffen einfacher, schneller und kostengünstiger als mit bisherigen Methoden bestimmen?
Die Dissertation zeigt auf, dass man das grundlegende physikalische Prinzip einer Isotopverschiebung mit in Adlershof entwickelten Optik-Instrumenten für die Herkunftsbestimmung nutzen kann. Die entwickelte Methode ermöglicht es in Zukunft den Ursprung von Rohstoffen, Lebensmitteln oder Umweltschadstoffen kostengünstiger und wesentlich schneller bestimmen, als dies mit bisherigen Methoden möglich ist.
Kann man das grundlegende physikalische Prinzip einer Isotopieverschiebung mit einem Optik-Instrument für die Herkunftsbestimmung nutzen? Carlos Abad hat eine wegweisende Methode entwickelt, die es in Zukunft ermöglicht den Ursprung von Rohstoffen, Lebensmitteln oder Umweltschadstoffen kostengünstiger und wesentlich schneller bestimmen, als dies mit bisherigen Techniken möglich ist.
Science Café Adlershof is having its next edition in 2024 on February 20th '24! We will have one speaker next week: Alexander Winckelmann is a PhD student at Bundesanstalt für Materialforschung und -Prüfung and will give a talk about his stay abroad in Switzerland - there will be free chocolates! There will be enough time to ask questions or simply chat with the guests and participants.
Zeolitic imidazolate framework (ZIF) hybrid fluorescent nanoparticles and ZIF antibody conjugates have been synthesized, characterized, and employed in lateral-flow immunoassay (LFIA). The bright fluorescence of the conjugates and the possibility to tailor their mobility gives a huge potential for diagnostic assays. An enzyme-linked immunosorbent assay (ELISA) with horseradish peroxidase (HRP) as label, proved the integrity, stability, and dispersibility of the antibody conjugates, LC-MS/MS provided evidence that a covalent link was established between these metal-organic frameworks and lysine residues in IgG antibodies.
Laser-induced XUV spectroscopy (LIXS) is an emerging technique for elemental mapping. In comparison to conventional laser-induced breakdown spectroscopy in UV-vis (LIBS), it has a higher precision and wider dynamic range, and it is well suited for the quantification light elements like lithium and fluorine. Further it can spot oxidation states. The XUV spectra are produced at a very early stage of the plasma formation. Therefore, effects from plasma evolution on the reproducibility can be neglected. It has been shown, that high-precision elemental quantification in precursor materials for lithium-ion batteries (LIBs) can be performed using LIXS. Based on these results, LIXS mapping was used to investigate aging processes in LIBs. Different cathode materials with varying compositions of fluorine containing polymer binders were compared at different stages of aging. Due to effects comparable to X-ray photoelectron spectroscopy but in reverse, monitoring of changes in the oxidation state is envisioned, which makes information about the chemical environment of the observed elements accessible. The combination of elemental distribution and structural information leads to a better understanding of aging processes in LIBs, and the development of more sustainable and safe batteries.
Small variations in the isotopic composition of some elements have been used as proof of provenance of mineral and biological samples, to describe geological processes, and to estimate a contamination source. Routinely, isotope compositions are measured by mass spectrometry; the working horse of the isotope analysis. However, mass spectrometric methods are expensive, time-consuming and they require a high qualified analyst.
Here, an alternative faster and low-cost optical method for isotope ratio determination is investigated: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS). Stable isotope amount composition of X = Li, B, Mg, Ca and Sr have been determined by monitoring the absorption spectra of their in situ generated hydrides (XH) in graphite furnace HR-CS-MAS. For example, the system of two stable isotopes of boron (10B and 11B) was studied via its hydride for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, isotopic composition of samples and reference materials are calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results are metrologically compatible with those reported by mass spectrometric methods. [1] Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shift of their isotopologues can be resolved as shown in Fig.1 b. The extension of this methodology to other elements like Li, Ca and Sr is discussed [2].
References:
[1] C. Abad, S. Florek, H. Becker-Ross, M.-D. Huang, H.-J. Heinrich, S. Recknagel, J. Vogl, N. Jakubowski, U. Panne, Determination of boron isotope ratios by high-resolution continuum source molecular absorption spectrometry using graphite furnace vaporizers, Spectrochim. Acta, Part B, 136 (2017) 116-122.
[2] C. Abad et al., unpublished results, 2018.
We propose an alternative faster and low-cost optical method for isotope analysis: high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS).
Stable isotope amount composition of X = Li, B, Mg, Ca and Sr were determined by monitoring the absorption spectra of their in situ generated mono-hydrides (XH) in graphite furnace HR-CS-MAS. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X1Σ+ → A1Π (Fig. 1a). The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library is built by using samples with known isotope composition. Results with an accuracy of 0.15 ‰ are metrologically compatible with those reported by mass spectrometric methods. Similar results are obtained for n isotope systems like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved as shown in Fig.1b. The extension of this methodology to other elements like Li, Ca and Sr is discussed.
Magnesium (Mg) is a major element in a range of silicate and carbonate minerals, the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg with natural abundances of 79 %, 10 %, and 11 %, respectively. It is due to their relatively large mass difference (~8% between 24Mg and 26Mg) that isotope fractionation leads to slight variations of isotope amount ratios n(26Mg)/n(24Mg) in biological, environmental and geological samples. Traditionally, isotope ratios are measured by mass spectrometric methods and isotope ratios are expressed as deviation from an internationally agreed upon material, i.e. the zero-point of the δ-value scale. Drawbacks of this method include the high costs for instruments and their operation, experienced operators and elaborate, time-consuming chromatographic sample preparation.
Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high- resolution continuum source graphite furnace molecular absorption spectrometry (HR- CS-GFMAS) and laser ablation molecular isotopic spectrometry (LAMIS).
For the determination of Mg isotope amount ratios, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied. In the case of HR-CS-GFMAS, the absorption spectrum was recorded for MgF for the electronic transitions X2Σ → A2Πi and X 2Σ → B2Σ+ around wavelengths 358 nm and 268 nm, respectively. In the case of LAMIS, we investigated the MgF molecule for the electronic transition A2Πi → X2Σ as well as the MgO molecule for the electronic transition A1Π+ → X1Σ around 500 nm. The MgF and MgO spectra are described by the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO (F is monoisotopic, and the isotope composition of O is assumed as constant). By HR-CS-GFMAS the analysis of Mg was done by deconvolution of the MgF spectrum by partial least square regression (PLS) calibrated with enriched isotope spikes. Isotope amount ratios in rock samples with and without matrix separation were analyzed. Calculated δ-values were accurate and obtained with precisions ranging between 0.2 ‰ and 0.5 ‰ (1 SD, n = 10). On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of in-situ analysis. Main advantages, limitations, and scopes of both optical techniques are going to be discussed and compared to MC-ICP-MS.
Magnesium is a naturally occurring element that can be found in several mineral forms in the earth crust. This element presents three stable isotopes 24Mg, 25Mg and 26Mg with a natural abundance of 79%, 10%, and 11% respectively. It is due to their relatively large mass difference (~8% between 24Mg and 26Mg) that isotope fractionation leads to slight isotope amount ratio variations n(26Mg)/n(24Mg) in biological and geological samples. Traditionally, isotope amount ratios have been measured by mass spectrometric methods. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time-consuming. Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) and laser ablation molecular isotopic spectrometry (LAMIS). For the determination of Mg isotope amount ratios, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied. In the case of HR-CS-GFMAS, the absorption spectrum was recorded for MgF for the electronic transitions X 2Σ → A 2 Πi and X 2Σ → B 2Σ+ around wavelengths 358 nm and 268 nm respectively. In the case of LAMIS, it was studied the MgF molecule for the electronic transitions A 2Πi → X 2Σ as well as the MgO molecule for the electronic transition A 1Π+ → X 1Σ around 500 nm. The MgF and MgO spectra are composed by the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO (F is monoisotopic, and the isotope composition of O is assumed as constant). By HR-CS-GFMAS the analysis of Mg was done by deconvolution of the MgF spectrum by a partial least square regression (PLS) calibrated with enriched isotope spikes. The isotope amount ratios in rock samples with and without matrix separation were analyzed. Resulting delta values were obtained with precisions ranging between 0.2-0.5 ‰. On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of in-situ analysis. Main advantages, limitations, and scopes of both optical techniques are going to be discussed and compared with MC-ICP-MS.
Simultaneous multielemental analysis of crude oils by high-resolutions absorption spectrometry
(2019)
When crude oil arrives at a refinery it needs a lot of processing before it is suitable for cracking into lighter fractions. Sulfur has to be extracted to meet ultra-low sulfur legislation for most of the fuel grades, and desalination is a crucial process as chlorine within salts is corrosive to refinery equipment. Measuring the amounts of sulfur and chlorine within crude oil is the first step in a complex clean-up process.
Heavy metals, such as vanadium, nickel and iron need to be removed too. These metals can poison the catalyst used to crack the oil into lighter fractions. This is costly as it reduces the useful life of the catalyst. Like chlorine, heavy metals also have a corrosive effect on the plant. There is some evidence that the presence of some metals in the final product can reduce performance.
A fast determination of elements and size of suspended particles is vital for diagnosis and safeguard of refinery equipment. However, sample preparation for current analytical methods consumes precious time and lost particle size information.
High-resolution continuum source graphite furnace absorption spectrometry (HR-CS-GFAS) is proposed as a fast analytical method for elemental determination in crude oils and potentially for simultaneous multielement and particle size analysis. This HR-CS-GFAS instrumentation is coupled to a modular simultaneous echelle spectrometer (MOSES) and provides a full optical window with high resolution (from 180 to 900 nm with bandwidth λ/170,000). By using this set-up, it is possible to generate a multiparameter 3D spectral image (atomic and molecular lines, isotopic shift, atomization delay, and intensities). The generated spectral images can be analyzed by multivariate regressions for the elemental and particle size analysis. Additionally, if several atomic and molecular lines are simultaneously measured, they may be used in multi-energy calibration (MEC), a method based on the use of many wavelengths of the same absorbing/emitting entity to improve the accuracy in analytical atomic spectrometry. This MEC approach combined with multivariate image analysis allows the quantification of selected elements (Si, Al, Ni, Fe, V, S, and Cl) and overcomes matrix effects.
The high ionization potentials and low wavelength emission lines of halogens difficult the analysis of their organohalogen compounds by ICP-based methods [1]. Other techniques, such as combustion ion chromatography (CIC) or ion-selective electrodes have proven to be more reliable to determine these elements. However, these techniques are more time-consuming and/or have lower precision and accuracy.
High resolution continuum source graphite furnace molecular absorption spectrometry (HR CS GFMAS) allows the determination of solid and liquid samples by monitoring a molecule formed with the analyte and a molecule forming reagent. In the case of F, Cl and Br, several molecule forming agents have been studied for their determination. Among all of them, calcium can form a stable bond with the three elements and provides optimal analytical properties for trace analysis [2]. However, the spectral window of commercially available continuum source AAS instruments is not broad enough to cover the wavelength range necessary for a simultaneous determination. Thus, coupling it with a modular simultaneous echelle spectrograph (MOSES), which can register around 200 nm in a single measure, allows the simultaneous study of the three analytes [3].
This instrumentation is capable of register more than 200 nm of the spectra per measure keeping a high resolution. This spectral window is suitable for the monitorization of a variety of transitions of the three molecules. However, some of them are overlapped and the competitive mechanism of formation of the three molecules modify their sensitivity depending on the proportions in the sample.
In this study, a compromise in the conditions and modifiers were selected in order to maximize the sensitivity and signal to noise ratio for the three molecules. The determination was carried out by standard addition of CaF and Cl and Br were obtained from the PLS model.
References:
[1] X. Bu, T. Wang, G. Hall, J. Anal. At. Spectrom., 18, 1443–1451 (2003)
[2] M. Resano, E. García-Ruiz, M. Aramendía, M. A. Belarra, J. Anal. At. Spectrom., 34, 59–80 (2019)
[3] S. Geisler, M. Okruss, H. Becker-Ross, M. Dong Huang, N. Esser, S. Florek, Spectrochimica Acta PartB, 107, 11–16 (2015)
Shortly after founding the CCQM in 1993, the first key comparison (CCQM-K2) about the determination of Cd and Pb content in river water was hosted by IRMM. It has been clear from the beginning that for the determination of an element mass fraction in a matrix, accurate reference solutions would be the key point for a metrologically sound analysis. Triggered by the not entirely satisfactory results it was decided to investigate the basis of all measurements: the reference solutions. Thus in 1999, CCQM-K8, hosted by EMPA/LNE, started the tedious but indispensable work on elemental solutions standards.
Additionally, PTB, BAM and Merck KGaA initiated a project to establish a traceability system for inorganic analysis based on accurate monoelemental solutions. Within this unique approach ten high purity reference materials were fully characterized, and solutions were prepared gravimetrically thereof. These materials (forming the primary standards of elemental analysis) are available for NMIs/DIs from BAM.
CCQM-P46 (Cu, Mg, Rh) demonstrated the actuality of the topic and the challenges to prepare elemental solutions for every element. The accurate preparation and use of monoelemental solutions is consequently reflected in the recurrent conduct of (key) comparisons: CCQM-P149 (purity of zinc), CCQM-K87 (Co, Cr, Pb), and the current CCQM-K143/P181 (Cu solutions), to name only a few in a long series.
Is it necessary to put so much effort into the preparation of reference solutions? It clearly is! An example outside the world of academia: Recently, EDQM*, PTB, BAM and JRC have developed monoelemental reference standards traceable to the SI for toxic elements in support of the chapters of the European Pharmacopoeia, related to the analysis of elemental impurities in medicinal products. A new ICP OES method has been established allowing the comparison of two 1 g/kg mercury solutions with an outstandingly small uncertainty of Urel(w(Hg)) = 0.16 %. However, this technical progress would not have been possible without the ongoing effort of the metrological community within 25 years of research in the field of high accuracy monoelemental solutions.
* EDQM: European Directorate for the Quality of Medicines and HealthCare