1.4 Prozessanalytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (12)
- Vortrag (8)
- Posterpräsentation (3)
- Beitrag zu einem Tagungsband (1)
- Forschungsdatensatz (1)
Schlagworte
- NIR (8)
- Chemometrie (4)
- Microplastics (4)
- CONSENS (3)
- Chemometrics (3)
- Raman (3)
- Lignin (2)
- Mineralwolle (2)
- Multivariate data analysis (2)
- NIR Spektroskopie (2)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (25)
- 1.4 Prozessanalytik (25)
- 6 Materialchemie (3)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 1.7 Organische Spuren- und Lebensmittelanalytik (1)
- 4 Material und Umwelt (1)
- 4.4 Thermochemische Reststoffbehandlung und Wertstoffrückgewinnung (1)
- 5 Werkstofftechnik (1)
- 5.3 Polymere Verbundwerkstoffe (1)
- 6.3 Strukturanalytik (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (8)
The interaction of microcroplastics (MP) with dissolved organic matter, especially humic substances, is of great importance in understanding the behavior of microplastics in aquatic ecosystems. Surface modification by humic substances plays an essential role in transport and interaction of MP with abiotic and biotic components. Previous studies on the interaction between MP and humic substances were largely based on a model compound, humic acid (Sigma-Aldrich). In our work, we therefore investigated the interaction of natural organic matter (NOM) sampled from a German surface water with low-density polyethylene particles (LDPE). Highpressure size exclusion chromatography (HPSEC) and UV/vis absorption and fluorescence spectroscopy were used to characterize the incubation solutions after modifications due to the presence of LDPE, and Raman spectroscopy was used to characterize the incubated microplastics. While the studies of the solutions generally showed only very small effects, Raman spectroscopic studies allowed clear evidence of the binding of humic fractions to MP. The comparison of the incubation of NOM and a lignite fulvic acid which also was tested further showed that specific signatures of the humic substances used could be detected by Raman spectroscopy. This provides an elegant opportunity to conduct broader studies on this issue in the future.
In Deutschland werden jährlich rund 20 Millionen Tonnen künstliche Mineralwolle für die Dämmung von Dächern und Fassaden sowie für Brandschutzprodukte verwendet. Um künstliche Mineralwolle aus Rückbaumaßnahmen in den Produktionsprozess zurückführen zu können, ist eine Trennung in Glas- und Steinwolle erforderlich, um eine Vermischung der beiden Produkte, die unterschiedliche Schmelztemperaturen aufweisen, zu vermeiden. Anstatt die Mineralwolle in spezielle Labors zu schicken, was zeitaufwendig und teuer ist, wurde das Potenzial eines tragbaren Nahinfrarot-Spektrometers (NIR) für den Einsatz vor Ort getestet. 140 verschiedene Mineralwolleproben wurden untersucht, um eine NIR-basierte Methode für die Vor-Ort-Unterscheidung zwischen Glas- und Steinwolle zu etablieren. Die Validierung der Methode mit Testproben und die Anwendung auf Materialien, die aus BigBags für Deponien entnommen wurden, haben gezeigt, dass die Methode präzise und robust ist. Als Referenzmethode wurde die Röntgenfluoreszenzspektroskopie (RFA) mit einer Kalibrierung auf der Grundlage der VDI 3492 verwendet.
The leaching behavior of scandium (Sc) from bauxite residues can differ significantly when residues of different geological backgrounds are compared. The mineralogy of the source rock and the physicochemical environment during bauxitization affect the association of Sc in the bauxite i.e., how Sc is distributed amongst different mineral phases and whether it is incorporated in and/or adsorbed onto those phases. The Sc association in the bauxite is in turn crucial for the resulting Sc association in the bauxite residue. In this study systematic leaching experiments were performed on three different bauxite residues using a statistical design of experiments approach. The three bauxite residues compared originated from processing of lateritic and karstic bauxites from
Germany, Hungary, and Russia. The recovery of Sc and Fe was determined by ICP-OES measurements. Mineralogical changes were analyzed by X-ray-diffraction and subsequent Rietveld refinement. The effects of various parameters including temperature, acid type, acid concentration, liquid-to-solid ratio and residence time were studied. A response surface model was calculated for the selected case of citric acid leaching of Hungarian bauxite residue. The investigations showed that the type of bauxite residue has a strong influence. The easily leachable fraction of Sc can vary considerably between the types, reaching ~20–25% in German Bauxite residue and ~50% in Russian bauxite residue. Mineralogical investigations revealed that a major part of this fraction was released from secondary phases such as cancrinite and katoite formed during Bayer processing of the bauxite.
The effect of temperature on Sc and Fe recovery is strong especially when citric acid is used. Based on the exponential relationship between temperature and Fe-recovery it was found to be particularly important for the selectivity of Sc over Fe. Optimization of the model for a maximum Sc recovery combined with a minimum Fe
recovery yielded results of ~28% Sc recovery at <2% Fe recovery at a temperature of 60 ◦C, a citric acid normality of 1.8, and a liquid-to-solid ratio of 16 ml/g. Our study has shown that detailed knowledge about the Sc association and distribution in bauxite and bauxite residue is key to an efficient and selective leaching of Sc
from bauxite residues.
Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and highthroughput mass quantification of microplastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermoanalytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg.
The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most
compact NIR spectrometers available.
Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and high-throughput mass quantification of micro¬plastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermo-analytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg. The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most compact NIR spectrometers available.
Raman spectroscopy for online monitoring of a homogeneous hydroformylation process in microemulsion
(2021)
An important industrial reaction is hydro¬formylation for the production of aldehydes from alkenes and syngas on the basis of homogeneous catalysis. The main cost factors of the processes currently used are product selectivity and the loss of the catalysts used. Therefore, various concepts for the hydroformylation of long-chain olefins have been developed, including hydroformylation in microemulsions, which is being investigated on a mini-plant scale at the Technical University of Berlin [1]. In this study, online Raman spectroscopy of the reaction of 1-dodecene to 1-tri¬decanal in a microemulsion was performed [2]. First, an experimental design was used to obtain a good representation of the operating range in the mini plant with respect to the concentrations of five reactants in a laboratory setup [3]. Based on the Raman spectra, Partial Least Squares (PLS) models for the prediction of 1-dodecene and 1-tride-decanal were calibrated and with these the reactions were predicted on a laboratory scale. In the next step, the PLS models were applied to online spectra from a mini-plant. This resulted in promising estimates of 1-tridecanal and acceptable predictions of 1-dodecene mass fractions. The predictive power of PLS models in this particular case was limited by unexpected by-product formation which, however, can easily be compensated by an extended calibration. Hence, Raman spectroscopy is a promising technique for process analysis in microemulsions.
Für die Rückführung von aus Rückbauprojekten anfallender künstlicher Mineralwolle in ihren Herstellungsprozess ist es notwendig, Stein- und Glaswolle zu unterscheiden und voneinander getrennt zu halten. Zu diesem Zweck wurde das Potential von NIR-Spektroskopie (NIRS) für einen werks- oder baustellenseitigen Einsatz getestet. NIRS wird aufgrund kurzer Messzeiten, minimaler Probenvorbereitung und hoher Robustheit der Spektrometer häufig in der Prozessanalytik eingesetzt. Untersucht wurden 70 verschiedene Mineralwollen, wobei sich der Probenumfang sowohl aus werksneuen Proben mit Herstellerangaben als auch unbekannten Proben ohne Spezifikation zusammensetzen, die auf verschiedenen Baustellen in den Jahren 2016–2017 entnommen oder von Deponien zur Verfügung gestellt worden waren. Als Referenzmethode wurde die Röntgenfluoreszenzanalyse verwendet, um den Mineralwolle-Typ über den Elementgehalt nach VDI 3492 zu identifizieren. Mit Hilfe eines multivariaten Datenanalyseverfahrens konnte schließlich eine Methode etabliert werden, die eine zuverlässige Identifikation von unbekannten Mineralwollen anhand deren NIR-Spektren als Stein- bzw. Glaswolle ermöglicht.
Künstliche Mineralfasern (KMF) werden weltweit in vielfältiger Weise als Dämmstoffe verwendet. Jährlich fallen in Deutschland ungefähr 20 Millionen Tonnen KMF an, die nach dem Abriss auf Deponien entsorgt werden müssen. Grundsätzlich besteht jedoch die Möglichkeit der Rückführung dieser Materialien in den Produktionsprozess. Dafür ist es notwendig, anfallende KMF sowohl nach Material (Glaswolle, Steinwolle) als auch nach Alter zu sortieren.
Auf der Suche nach einer Methode, die es grundsätzlich gestattet eine schnelle Untersuchung vor Ort auf einer Baustelle durchzuführen, wurde die Nah-Infrarot (NIR) Spektroskopie unter Verwendung eines Prozessspektrometers mit Reflexionssonde getestet. Anhand von Laboruntersuchungen an 70 KMF Proben, die entweder betriebsneu waren oder bundesweit auf Baustellen gesammelt wurden, konnte eine NIR-basierte Methode zur Unterscheidung in Glas- und Steinwolle entwickelt werden. Mittels Partial Least Square Diskriminanzanalyse (PLS-DA) der NIR Spektren wurde basierend auf 40 zufällig ausgewählten Proben ein chemometrisches Modell kalibriert, das erfolgreich zur Klassifizierung der verbleibenden 30 Proben eingesetzt werden konnte. Unabhängig von Farbe, Dichte oder Alter der untersuchten KMF Proben war es möglich, eine 100% korrekte Zuordnung des Materials zu erzielen. Die nötigen Referenzwerte wurden unter Nutzung eines Röntgenfluoreszenzspektroskopischen Verfahrens über den Elementgehalt nach VDI 3492 ermittelt.
Insgesamt ist der experimentelle Aufwand für die Durchführung und Auswertung der NIR Messungen gering und manifestiert sich vor allem in der Kalibrierphase, die in diesem Fall die Untersuchung von 8-fach aliquotierten Probestücken der 70 KMF umfasste. Nur bei deutlich feuchtem Material muss ein zusätzlicher Trocknungs-schritt berücksichtigt werden. Das vorgestellte Verfahren wurde nachfolgend zu einem Patent angemeldet. Untersuchungen zu einer weiteren Unterscheidung der KMF nach Alter sind geplant.
The increasing enrichment of water bodies and soils with plastic waste leads to the accumulation of microscopic plastic particles, so-called microplastics (MP). There is an urgent need for analytical methods that help to identify and quantify MP. At present, mainly thermo-analytical and microscopic methods such as micro-infrared spectroscopy or micro-Raman are used for this purpose. The latter are usually tied to time-consuming sample enrichment and preparation, only small sample quantities (micrograms) can be examined and the evaluation of the obtained spectra can be demanding. In the context of this presentation, two approaches are presented which, via the multi-variate analysis of spectroscopic data, allow i) a new methodological approach to screening MP in contaminated soils and ii) an alternative evaluation of large (micro)-spectroscopic data sets.
First, a NIR spectroscopic method is presented which allows MP consisting of polyethylene, polyethylene terephthalate, polypropylene and polystyrene to be detected in the range of up to 0.5 mass percent. Due to short measurement times and robust technology, this approach has the potential, in contrast to thermo-analytical and micro-spectroscopic methods, to examine larger sample quantities with minimal pre-treatment.
The second approach deals with the evaluation of large data sets, as typically obtained as a result of micro-FTIR using modern FPA detectors. The micro-FTIR technique is based on the spectral recording, imaging and subsequent identification of vibration bands typical of synthetic polymers. The image data sets are large and contain spectra of numerous particles of natural and synthetic origin. Exploratory multivariate data analysis has been tested to complement existing approaches based on e.g. spectrum library searches. The core concept used was dimensionality reduction. The results not only represent an orthogonal method for checking the results obtained by an automated library search, but also revealed a group of spectra that were not recorded in the existing spectrum libraries.
Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied, which require excessive calibration effort. NMR spectroscopy has a high potential for direct loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and harsh environ¬ments for advanced process monitoring and control, as demonstrated within the European Union’s Horizon 2020 project CONSENS.
We present a range of approaches for the automated spectra analysis moving from conventional multivariate statistical approach, (i.e., Partial Least Squares Regression) to physically motivated spectral models (i.e., Indirect Hard Modelling and Quantum Mechanical calculations). By using the benefits of traditional qNMR experiments data analysis models can meet the demands of the PAT community (Process Analytical Technology) regarding low calibration effort/calibration free methods, fast adaptions for new reactants or derivatives and robust automation schemes.
The catalytic behavior of iron phthalocyanine (FePc)-sensitized magnetic nanocatalysts was evaluated for their application in the oxidative treatment of Bisphenol A (BPA) under mild environmental conditions. Two types of FePc (Fe(II)Pc and Fe(III)Pc), which are highly photosensitive compounds, were immobilized on the surface of functionalized magnetite. The nanomaterials were characterized by high resolution transmission electron microscopy (HR-TEM), X-ray difraction (XRD), Fourier transform infrared spectroscopy (FTIR) and thermogravimetric analyses (TGA). The generation of singlet Oxygen by nanomaterials was also investigated. In the presence of UVA light exposure (365nm) and 15mM H2O2, the M@Fe(III)Pc photocatalyst gave the best results; for a catalyst concentration of 2.0gL −1, around 60% BPA was removed after 120min of reaction. These experimental conditions were further tested under natural solar light exposure, for which also M@Fe(III)Pc exhibited enhanced oxidative catalytic activity, being able to remove 83% of BPA in solution. The water samples were less cytotoxic after treatment, this being confrmed by the MCF-7 cell viability assay.
Exploratory analysis of hyperspectral FTIR data obtained from environmental microplastics samples
(2020)
Hyperspectral imaging of environmental samples with infrared microscopes is one of the preferred methods to find and characterize microplastics. Particles can be quantified in terms of number, size and size distribution. Their shape can be studied and the substances can be identified. Interpretation of the collected spectra is a typical problem encountered during the analysis. The image datasets are large and contain spectra of countless particles of natural and synthetic origin. To supplement existing Analysis pipelines, exploratory multivariate data analysis was tested on two independent datasets. Dimensionality reduction with principal component analysis (PCA) and uniform manifold approximation and projection (UMAP) was used as a core concept. It allowed for improved visual accessibility of the data and created a chemical two-dimensional image of the sample. Spectra belonging to particles could be separated from blank spectra, reducing the amount of data significantly. Selected spectra were further studied, also applying PCA and UMAP. Groups of similar spectra were identified by cluster analysis using k-means, density based, and interactive manual clustering. Most clusters could be assigned to chemical species based on reference spectra. While the results support findings obtained with a ‘targeted analysis’ based on automated library search, exploratory analysis points the attention towards the group of unidientified spectra that remained and are otherwise easily overlooked.
The transformation of a base-catalyzed, mechano-assisted Knoevenagel condensation of mono-fluorinated benzaldehyde derivatives (p-, m-, o-benzaldehyde) with malonodinitrile was investigated in situ and in real time. Upon milling, the para-substituted product was found to crystallize initially into two different polymorphic forms, depending on the quantity of catalyst used. For low catalyst concentrations, a mechanically metastable phase (monoclinic) was initially formed, converting to the mechanically stable phase (triclinic) upon further grinding. Instead, higher catalyst concentrations crystallize directly as the triclinic product. Inclusion of catalyst in the final product, as evidenced by mass spectrometric analysis, suggests this complex polymorphic pathway may be due to seeding effects. Multivariate analysis for the in situ Raman spectra supports this complex formation pathway, and offers a new approach to monitoring multi-phase reactions during ball milling.
In case study one of the CONSENS project, two aromatic substances were coupled by a lithiation reaction, which is a prominent example in pharmaceutical industry. The two aromatic reactants (Aniline and o-FNB) were mixed with Lithium-base (LiHMDS) in a continuous modular plant to produce the desired product (Li-NDPA) and a salt (LiF). The salt precipitates which leads to the formation of particles. The feed streams were subject to variation to drive the plant to its optimum.
The uploaded data comprises the results from four days during continuous plant operation time. Each day is denoted from day 1-4 and represents the dates 2017-09-26, 2017-09-28, 2017-10-10, 2017-10-17.
In the following the contents of the files are explained.
Flexible automation with compact NMR spectroscopy for continuous production of pharmaceuticals
(2019)
Modular plants using intensified continuous processes represent an appealing concept for the production of pharmaceuticals. It can improve quality, safety, sustainability, and profitability compared to batch processes; besides, it enables plug-and-produce reconfiguration for fast product changes. To facilitate this flexibility by real-time quality control, we developed a solution that can be adapted quickly to new processes and is based on a compact nuclear magnetic resonance (NMR) spectrometer. The NMR sensor is a benchtop device enhanced to the requirements of automated chemical production including robust evaluation of sensor data. Beyond monitoring the product quality, online NMR data was used in a new iterative optimization approach to maximize the plant profit and served as a reliable reference for the calibration of a near-infrared (NIR) spectrometer. The overall approach
was demonstrated on a commercial-scale pilot plant using a metal-organic reaction with pharmaceutical relevance.
Die Untersuchungen sind durch das das DFG Schwerpunktprogramm 1374 für Biodiversitätsforschung motiviert. Anhand des überwachten Abbaus von Totholz soll untersucht werden, welche Auswirkung unterschiedliche Formen und Intensitäten der Landnutzung auf die Biodiversität innerhalb von drei Exploratorien zeigen. Bei den vorangegangenen Studien wurden Nahrungs¬netzte auf organismischer Ebene sowie Klima- und Umgebungsdaten untersucht und die Veränderung des ausgebrachten Totholzes als Masseverlust erfasst. Es wird jedoch erwartet, dass in Anhängigkeit der beteiligten Organismen und Umgebungsparameter verschiedene Mechanismen des Holzabbaus vorliegen, die in unterschiedlichen Abbauraten der Holzkomponenten Lignin, Cellulose und Hemicellulose resultieren. Aus diesem Grund ist die quantitative Untersuchung des Ligningehalts an Hölzern ein wesentlicher Schritt für ein verbessertes Verständnis der Biodiversität in den untersuchten Exploratorien. Um der hohen Probenanzahl, die sich aus der Kontrolle von jeweils 100 Proben (Plots) in den drei Exploratorien für Hölzer aus 13 Baumarten ergibt, gerecht zu werden, wird eine schnelle und effiziente Untersuchungsmethode benötigt. Diese wird derzeit in Form einer NIR-spektroskopischen Bestimmung des Ligningehalts entwickelt. Um basierend auf den NIR Spektren vermahlener Holzproben Lignin und weitere Holzkomponenten korrekt vorherzusagen, muss zunächst basierend auf nasschemischen Analysen ein chemometrisches Modell kalibriert werden. Dazu ist die Charakterisierung von mindestens 20 – 30 Proben, die eine hohe Varianz des Ligningehalts aufweisen, notwendig. Im Vortrag werden erste Untersuchungs¬ergebnisse für die Vorhersage des Ligningehalts von Kiefernhölzern, die für ein Jahr in dem Exploratorium Schorfheide exponiert wurden, vorgestellt. Die anschließende explorative Datenanalyse (PCA) unter Verwendung von insgesamt 28 Variablen zur Beschreibung klimatischer und Umgebungsparameter weist eine Reihe interessanter Korrelationen auf. Demnach ist der Ligningehalt auf der ersten Hauptkomponente (29% erklärte Varianz) positiv mit dem C/N-Verhältnis und negativ mit Landnutzungsindex korreliert. Masseverlust und Temperatur hingegen dominieren die zweite Hauptkomponente (12% erklärte Varianz).
Modular plants using intensified continuous processes represent an appealing concept to produce pharmaceuticals. It can improve quality, safety, sustainability, and profitability compared to batch processes, and it enables plug-and-produce reconfiguration for fast product changes. To facilitate this flexibility by real-time quality control, we developed a solution that can be adapted quickly to new processes and includes a compact Nuclear Magnetic Resonance (NMR) spectrometer for online quality monitoring as well as a new model-based control approach. The NMR sensor is a benchtop device enhanced to the requirements of automated chemical production including ro-bust evaluation of sensor data.
Here, we present alternatives for the quantitative determination of the analytes using modular, physically motivated models. These models can be adapted to new substances solely by the use of their corresponding pure component spectra, which can either be derived from experimental spectra as well as from quantum mechanical models or NMR predictors. Modular means that spec-tral models can simply be exchanged together with alternate reagents and products. Beyond that, we comprehensively calibrated an NIR spectrometer based on online NMR process data for the first time within an industrial plant. The integrated solution was developed for a metal organic reac-tion running on a commercial-scale modular pilot plant and it was tested under industrial conditions.
Im DFG-Schwerpunktprogramm 1374, Teilprojekt FunWood IV, erfolgt in Kooperation mit dem Institut für Bioanalytik an Hochschule für angewandte Wissenschaften, Coburg und dem Helmholtz-Zentrum für Umweltforschung (UFZ), Leipzig die Untersuchung des Ligningehalts von natürlich gealterten Hölzern. Zu diesem Zweck soll an der BAM eine NIR spektroskopische Methode entwickelt werden, die auch zur Untersuchung großer Stückzahlen geeignet ist. Insgesamt liegen exponierte Proben von 13 verschiedenen Hölzern vor, die sukzessive durch die Kooperationspartner kryovermahlen und getrocknet werden. Für jede der 13 Arten wurden jeweils 300 Holzstücken ausgebracht, exponiert und im Sommer 2018 wieder eingesammelt. Die Ergebnisse sollen als Grundlage für die Bewertung eines Langzeitversuchs zum Einfluss von Waldbewirtschaftungsintensität und Baumartenidentität über mehrere geographische Dimensionen dienen.
Ziele und Durchführung eines geplanten Ringversuchs zur Untersuchung eines Dreikomponentensystems mittels NIR werden vorgestellt. Der Vortrag enthält einen kurzen Rückblick auf einen 2014 durchgeführten Ringversuch, wobei ein flüssiges Zweikomponentensystem untersucht wurde. Im Anschluss erfolgt die Erläuterung der verwendeten Komponenten, es werden Teilnahmebedingungen und mögliche Zeiträume bekannt gegeben.
The application of Raman spectroscopy as a monitoring technique for bioprocesses is severely limited by a large background signal originating from fluorescing compounds in the culture media. Here, we compare time-gated Raman (TG-Raman)-, continuous wave NIRprocess Raman (NIR-Raman), and continuous wave micro-Raman (micro-Raman) approaches in combination with surface enhanced Raman spectroscopy (SERS) for their potential to overcome this limit. For that purpose, we monitored metabolite concentrations of Escherichia coli bioreactor cultivations in cell-free supernatant samples. We investigated concentration transients of glucose, acetate, AMP, and cAMP at alternating substrate availability, from deficiency to excess. Raman and SERS signals were compared to off-line metabolite analysis of carbohydrates, carboxylic acids, and nucleotides. Results demonstrate that SERS, in almost all cases, led to a higher number of identifiable signals and better resolved spectra. Spectra derived from the TG-Raman were comparable to those of micro-Raman resulting in well-discernable Raman peaks, which allowed for the identification of a higher number of compounds. In contrast, NIR-Raman provided a superior performance for the quantitative evaluation of analytes, both with and without SERS nanoparticles when using multivariate data analysis.
A process spectroscopic approach for the monitoring of microplastics in environmental samples
(2018)
The potential of Raman and NIR process-spectroscopic as a rapid approach for the estimation of microplastics (MP) in soil matrix were tested. For this purpose, artificial MP/soil mixture samples consisting of standard soils or sand with defined ratios of MP (0,5 – 10 mass% polymer) from polyethylene (PE), polypropylene (PP), polystyrene (PS) and polyethylene terephthalate (PET) were prepared. MP particles with diameters < 2 mm and < 125 µm were obtained from industrial polymer pellets after cryo-milling. Spectra of these mixtures were collected by (i) a process FT-NIR spectrometer equipped with a reflection probe, (ii) by a cw-process Raman spectrometer and (iii) by a time-gated Raman spectrometer using fiber-optic probes. The evaluation of process-spectra was performed by chemometric methods. Whereas MP could be detected by Raman spectroscopy in coastal sand at 0.5 mass%, in standard soil detection of MP was limited to 10 – 5 mass% with the large fraction, but samples containing particles of the 125µm mass-fraction yielded no positive result at all. One reason for the lacking sensitivity could be fluorescence by soil organic matter and thus, in a next test time-gated Raman spectroscopy was applied. However, although being indeed more sensitive to the small particles this method failed at MP < 5 mass% indicating that fluorescence was not the major problem. Finally, FT-NIR was tested. Depending on the polymer, MP contents of 0,5 or 1 mass%, respectively, could be detected in standard soils and polymers identified. Furthermore, this approach could be used for the investigation of mixtures of up to four polymers and in real-world samples from bio-waste fermenter residues.
The increasing pollution of terrestrial and aquatic ecosystems with plastic debris leads to the accumulation of microscopic plastic particles of still unknown amount. To monitor the degree of contamination analytical methods are urgently needed, which help to quantify microplastics (MP). Currently, time-costly purified materials enriched on filters are investigated both by micro-infrared spectroscopy and/or micro-Raman. Although yielding precise results, these techniques are time consuming, and are restricted to the analysis of a small part of the sample in the order of few micrograms. To overcome these problems, here we tested a macroscopic dimensioned NIR process-spectroscopic method in combination with chemometrics. For calibration, artificial MP/soil mixtures containing defined ratios of polyethylene, polyethylene terephthalate, polypropylene, and polystyrene with diameters < 125 µm were prepared and measured by a process FT-NIR spectrometer equipped with a fiber optic reflection probe. The resulting spectra were processed by chemometric models including support vector machine regression (SVR), and partial least squares discriminant analysis (PLS-DA). Validation of models by MP mixtures, MP-free soils and real-world samples, e.g. and fermenter residue, suggest a reliable detection and a possible classification of MP at levels above 0.5 to 1.0 mass% depending on the polymer. The benefit of the combined NIRS chemometric approach lies in the rapid assessment whether soil contains MP, without any chemical pre-treatment. The method can be used with larger sample volumes and even allows for an online prediction and thus meets the demand of a high-throughput method.
Monitoring specific chemical properties is the key to chemical process control. Today, mainly optical online methods are applied, which require time- and cost-intensive calibration effort. NMR spectroscopy, with its advantage being a direct comparison method without need for calibration, has a high potential for closed-loop process control while exhibiting short set-up times. Compact NMR instruments make NMR spectroscopy accessible in industrial and rough environments for process monitoring and advanced process control strategies.
We present a fully automated data analysis approach which is completely based on physically motivated spectral models as first principles information (Indirect Hard Modelling – IHM) and applied it to a given pharmaceutical lithiation reaction in the framework of the European Union’s Horizon 2020 project CONSENS. Online low-field NMR (LF NMR) data was analysed by IHM with low calibration effort, compared to a multivariate PLS-R (Partial Least Squares Regression) approach, and both validated using online high-field NMR (HF NMR) spectroscopy.
Spectroscopic methods possess important advantages for the observation of bioprocesses: they are robust, gain many data within a short time scale, and allow for the measurement of multiple relevant information at the same time. Next to Near-infrared spectroscopy, Raman spectroscopy is increasingly applied as a powerful online tool to monitor bioprocesses. However, Raman spectra may be obscured by straylight, cosmic rays and fluorescence. To achieve the best performance, optimal conditions for spectral quality and stability should be pursued. This comprises not only the choice of highly-sensitive equipment, but also the way of implementation into the process. Here we compared the potential of introducing a sterilized fiber optical Raman probe, and a flow-through cell into the bypass of a stirred tank reactor to monitor an autotrophic cultivation of Ralstonia eutropha where gasses are the energy and carbon sources. Raman spectra were continuously recorded over seven days and 22 samples were taken for the reference analytics of biomass, optical density, and protein. In addition, data for of phosphate and ammonium were available. The quantitative Evaluation of Raman spectra by Partial Least Squares Regression (PLSR) yielded comparable results for both approaches, however, there was a general trend of lower prediction errors with the immersion probe.
The better performance of the non-contact optic may be either related to a more representative interaction of the measurement optics with the probe or simply to the absence of probe-fouling, which was observed with the immersion optic in the interstice between window and metal frame.