1.4 Prozessanalytik
Filtern
Dokumenttyp
- Posterpräsentation (11)
- Zeitschriftenartikel (7)
Sprache
- Englisch (18)
Schlagworte
- Soil (18) (entfernen)
Organisationseinheit der BAM
In precision agriculture, the estimation of soil parameters via sensors and the creation of nutrient maps are a prerequisite for farmers to take targeted measures such as spatially resolved fertilization. In this work, 68 soil samples uniformly distributed over a field near Bonn are investigated using laser-induced breakdown spectroscopy (LIBS). These investigations include the determination of the total contents of macro- and micronutrients as well as further soil parameters such as soil pH, soil organic matter (SOM) content, and soil texture. The applied LIBS instruments are a handheld and a platform spectrometer, which potentially allows for the single-point measurement and scanning of whole fields, respectively. Their results are compared with a high-resolution lab spectrometer.
The prediction of soil parameters was based on multivariate methods. Different feature selection methods and regression methods like PLS, PCR, SVM, Lasso, and Gaussian processes were tested and compared. While good predictions were obtained for Ca, Mg, P, Mn, Cu, and silt content, excellent predictions were obtained for K, Fe, and clay content. The comparison of the three different spectrometers showed that although the lab spectrometer gives the best results, measurements with both field spectrometers also yield good results. This allows for a method transfer to the in-field measurements
Detailed knowledge about soil composition is an important prerequisite for many applications, for example precision agriculture. Current standard laboratory methods are complex and time-consuming but could be complemented by non-invasive optical techniques. Its capability to provide a molecular fingerprint of individual soil components makes Raman spectroscopy a very promising candidate. A major challenge is strong fluorescence interference inherent to soil, but this issue can be overcome effectively using shifted excitation Raman difference spectroscopy (SERDS). A customized dual-wavelength diode laser emitting at 785.2 and 784.6 nm was used to investigate 117 soil samples collected from an agricultural field along a distance of 624 m and down to depths of 1 m. To address soil spatial heterogeneity, a raster scan approach comprising 100 measurement spots per sample was applied. Based on the Raman spectroscopic fingerprint extracted from intense fluorescence interference by SERDS, 13 mineral soil constituents were identified, and even closely related molecular species could be discriminated, for example polymorphs of titanium dioxide and calcium carbonate. For the first time, the capability of SERDS is demonstrated to predict the calcium carbonate content as an important soil parameter using partial least squares regression (R2 = 0.94, root mean square error of cross-validation RMSECV = 2.1%). Our findings demonstrate that SERDS can extract a wealth of spectroscopic information from disturbing backgrounds enabling qualitative and quantitative soil analysis. This highlights the large potential of SERDS for precision agriculture but also in further application areas, for example geology, cultural heritage and planetary exploration.
Near-infrared (NIR) spectroscopy is a promising candidate for low-cost, nondestructive, and high-throughput mass quantification of micro¬plastics in environmental samples. Widespread application of the technique is currently hampered mainly by the low sensitivity of NIR spectroscopy compared to thermo-analytical approaches commonly used for this type of analysis. This study shows how the application of NIR spectroscopy for mass quantification of microplastics can be extended to smaller analyte levels by combining it with a simple and rapid microplastic enrichment protocol. For this purpose, the widely used flotation of microplastics in a NaCl solution, accelerated by centrifugation, was chosen which allowed to remove up to 99 % of the matrix at recovery rates of 83–104 %. The spectroscopic measurements took place directly on the stainless-steel filters used to collect the extracted particles to reduce sample handling to a minimum. Partial least squares regression (PLSR) models were used to identify and quantify the extracted microplastics in the mass range of 1–10 mg. The simple and fast extraction procedure was systematically optimized to meet the requirements for the quantification of microplastics from common PE-, PP-, and PS-based packaging materials with a particle size < 1 mm found in compost or soils with high natural organic matter content (> 10 % determined by loss on ignition). Microplastics could be detected in model samples at a mass fraction of 1 mg g-1. The detectable microplastic mass fraction is about an order of magnitude lower compared to previous studies using NIR spectroscopy without additional enrichment. To emphasize the cost-effectiveness of the method, it was implemented using some of the cheapest and most compact NIR spectrometers available.
Knowing the exact nutrient composition of organic fertilizers is a prerequisite for their appropriate application to improve yield and to avoid environmental pollution by over-fertilization.
Traditional standard chemical analysis is cost and time-consuming and thus it is unsuitable for a rapid analysis before manure application. As a possible alternative, a handheld X-ray fluorescence (XRF) spectrometer was tested to enable a fast, simultaneous, and on-site analysis of several elements.
A set of 62 liquid pig and cattle manures as well as biogas digestates were collected, intensively homogenized and analysed for the macro plant nutrients phosphorus, potassium, magnesium, calcium, and sulphur as well as the micro nutrients manganese, iron, copper, and zinc using the standard lab procedure. The effect of four different sample preparation steps (original, dried, filtered, and dried filter residues) on XRF measurement accuracy was examined. Therefore, XRF results were correlated with values of the reference analysis. The best R2 s for each element ranged from 0.64 to 0.92. Comparing the four preparation steps, XRF results for dried samples showed good correlations (0.64 and 0.86) for all elements. XRF measurements using dried filter residues showed also good correlations with R2 s between 0.65 and 0.91 except for P, Mg, and Ca. In contrast, correlation Analysis for liquid samples (original and filtered) resulted in lower R2 s from 0.02 to 0.68, except for K (0.83 and 0.87, respectively). Based on these results, it can be concluded that handheld XRF is a promising measuring system for element analysis in manures and digestates.
The project “Intelligence for Soil” (I4S) aims at the design of an integrated system for improvement of soil functions and fertilizer recommendations. This system is composed by different sensors that will provide a detailed assessment of soil properties and processes, which are prerequisites for a site-specific, resource-saving and ecofriendly soil management, considering the soil as a sustainable resource for the bioeconomy. One of these sensors will be an energy-dispersive X-Ray Fluorescence spectrometer. It is a non-destructive technique suitable for in-situ measurements due to a minimum sample preparation and it allows fast multielement analyses. In this work, an automatic system has been developed using a handheld equipment from Olympus (Vanta C series). A polypropylene (PP) film was used to protect the measuring window of the device from dust and possible cross-contamination. To control the stepper motor that unrolls the PP film, a microcontroller was used to ensure that a piece of clean PP is in front of the measuring window for each new analysis.
Preliminary calibration studies using pre-defined methods, Geochem and Soil Methods, were performed with the following Certified Reference Materials (CRMs): NRC Till 1-3, NIST 2710, BAM U110, ERM CC141, BCR 142R, IAEA Soil 7. The CRMs were measured 10 times at different spots. The spot size was 10 mm in diameter, irradiation time was 60 ? s. The averaged data from X ray characteristic emission line intensities for Al, P, Si, Ca, Fe, Mn, Zn, Cu and Ni Kα were in close agreement with certified mass fraction data. The linear correlation coefficients (r) ranged from 0.852 for P to 0.999 for Mn. A second round of calibration studies were performed with the following CRMs: GBW07402, GBW 07405, NCS DC 73023, NCS DC 73030, NCS DC 85109, NCS DC 87104, NIST 1646a, NIST 2704, NIST 2710, NRC Till 1-3, VS 2498-83, and the same pre-defined methods and experimental parameters were employed. The results of the 13 CRMs were now compared with the values obtained by a validated WDXRF method. The linear correlation coefficients (r) ranged from 0.998 for Ca to 0.999 for Zn. Other elements such as S, K and Ti can also be properly determined, but validation still requires more robust calibration models.
Further calibration studies will be performed in order to circumvent matrix effects and to guarantee reliable results. Besides that, the automatic system will be placed on a mobile sensor platform and the system will be tested in the field. A guidance for on site-specific fertilization integrating the results obtained from different sensors placed on the platform is expected.
Within the framework of precision agriculture, the determination of various soil properties is moving into focus, especially the demand for sensors suitable for in-situ measurements. Energy-dispersive X-ray fluorescence (EDXRF) can be a powerful tool for this purpose. In this study a huge diverse soil set (n = 598) from 12 different study sites in Germany was analysed with EDXRF. First, a principal component analysis (PCA) was performed to identify possible similarities among the sample set.
Clustering was observed within the four texture classes clay, loam, silt and sand, as clay samples contain high and sandy soils low iron mass fractions. Furthermore, the potential of uni- and multivariate data evaluation with partial least squares regression (PLSR) was assessed for accurate Determination of nutrients in German agricultural samples using two calibration sample sets. Potassium and iron were chosen for testing the performance of both models. Prediction of these nutrients in 598 German soil samples with EDXRF was more accurate using PLSR which is confirmed by a better overall averaged deviation and PLSR should therefore be preferred.
Development of a robust calibration model for determination of nutrients in soils using EDXRF
(2018)
As part of the BonaRes research initiative, funded by the BMBF, strategies are being developed to use soil as a sustainable resource in the bio economy. The interdisciplinary subproject I4S - “Intelligence for soil” - is responsible for the development of an integrated system for site-specific management of soil fertility. For this purpose, a platform is constructed and various sensors are installed. Real-time data will be summarised in models and decision-making algorithms will be used to control fertilisation and accordingly improve soil functions. Aim of the BAM in the frame of I4S is the characterisation of an energy-dispersive X-ray fluorescence (EDXRF) based sensor for robust determination of plant essential nutrients in soil.
First a principal component analysis (PCA) was used to identify outliers and to observe the largest variance within the German soil samples. It could be monitored that splitting of the samples was due to their iron content. Given that clay samples contain high amounts of iron and sandy samples low amounts, a classification of the samples by their soil texture according to VD LUFA was possible. Considering the complex composition of soil, a matrix-specific calibration was carried out by univariate and multivariate data analysis. The figures of merit demonstrated that a more robust calibration model with negligible matrix effects can be obtained by a multivariate approach using partial least squares regression (PLSR). A better correlation between predicted values compared to reference values for German soil samples was observed for the chemometric calibration model than for the univariate one.
Different factors can affect the received calibration models such as moisture and particle size distribution which is especially important due to later online Analysis.
In first studies the influence of moisture on the detection of plant essential nutrients was investigated. With increasing water content, the characteristic fluorescence peaks decrease and start to increase again at a water content of 15 %. With lower moisture content the soil agglomerates which leads to lower packing of the sample, resulting in a rougher surface which negatively influence the signals. Whereas, agglomerates are not formed at higher water content. This allows the sample to be packed more tightly thus a smoother surface and a better homogeneity is obtained.
Furthermore, particle size distribution leads to significantly higher uncertainties and lower signals when comparing grounded (< 500 μm) and not grounded (< 2 mm) samples. This can be explained by amplifying of the already known inhomogeneity of soils. Both factors must be included in the chemometric PLSR to obtain robust calibration models for each macro and micro nutrient.
Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field.
The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration.
The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils.
Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field.
The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration.
The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils.
Over the last few years, there has been a growing interest to apply spectroscopic methods to the agricultural field for better understanding of soil properties and for efficient, sustainable management of arable land. Within the project I4S (intelligence for soil), funded by the BMBF, an integrated system for site-specific soil fertility management is developed, consisting of different sensors like X-Ray fluorescence analysis (XRF), near-infrared spectroscopy (NIR) and laser-induced breakdown spectroscopy (LIBS). LIBS provides a fast and simultaneous multi-element analysis with little to no sample preparation, which makes it a suitable method for real-time analysis on the field.
The quantification of macro and micro nutrients in soils with LIBS is challenging due to matrix effects, different levels of moisture content and varying grain sizes. First studies revealed that the problems with matrix effects can be overcome by using well characterised soils as reference materials and chemometric tools like Partial Least Squares Regression (PLSR) for calibration.
The next step was to investigate the influence of moisture and grain sizes on the LIBS signal, which is a big issue when measuring directly on the field. The results showed that the LIBS signal decreases exponentially with increasing moisture content, as most of the laser energy is used for vaporising the water. With moisture contents of 30 % or higher almost no signal can be detected. This decrease is more severe for sandy soils than for clay soils. First tests of different grain size distributions indicate that the variation of the LIBS signal increases with growing amounts of larger grains. This results in a higher standard deviation, because of a poorer reproducibility of the plasma formation and plasma characteristic. With the help of chemometric tools the influence of moisture and grain sizes should be implemented in the calibration model for accurate analysis of nutrient composition in agricultural soils.