1.3 Instrumentelle Analytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (36)
- Vortrag (31)
- Posterpräsentation (9)
- Buchkapitel (1)
- Sonstiges (1)
Schlagworte
- Laser ablation (12)
- Plasma chemistry (11)
- Emission spectroscopy (10)
- Laser induced plasma (10)
- Surface coating (10)
- Laser induced plasma deposition (8)
- Hydrodynamic model (7)
- LIBS (6)
- Lithium (6)
- Laser-induced plasma (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (78)
- 1.3 Instrumentelle Analytik (78)
- MP Mitglied des Präsidiums (13)
- PST Präsidiale Stabsstelle (13)
- 6 Materialchemie (11)
- 1.9 Chemische und optische Sensorik (9)
- 6.3 Strukturanalytik (8)
- 1.6 Anorganische Referenzmaterialien (7)
- P Präsident (7)
- P.0 Präsident und andere (7)
Paper des Monats
- ja (1)
The processes of hydrogen reduction of silicon and germanium chlorides under the conditions of high-frequency (40.68 MHz) counteracted arc discharge stabilized between two rod electrodes are investigated. The main gas-phase and solid products of plasma-chemical transformations are determined. Thermodynamic analysis of SiCl4 + H2 and GeCl4 + H2 systems for optimal process parameters was carried out. Using the example of hydrogen reduction of SiCl4 by the method of numerical modeling, gas-dynamic and thermal processes for this type of discharge are investigated. The impurity composition of gas-phase and solid reaction products is investigated. The possibility of single-stage production of high-purity Si and Ge mainly in the form of compact ingots, as well as high-purity chlorosilanes and trichlorogermane, is shown.
This course will provide an introduction to plasma diagnostic techniques. The major focus of the course will be on the discussions of the practical procedures as well as the underlying physical principles for the measurements of plasma fundamental characteristics (e.g., temperatures, thermodynamic properties, and electron number density). Particular emphasis will be placed on inductively coupled plasma–atomic emission spectrometry, but other analytical plasmas will also be used as examples when appropriate. Selected examples on how one can manipulate the operating conditions of the plasma source, based on the results of plasma diagnostic measurements, to improve its performance used for spectrochemical analysis will also be covered. Topics to be covered include thermal equilibrium, line profiles, temperatures, electron densities, excitation processes, micro reactions, pump and probe diagnostics, tomography,
temporal and spatial resolution. Basis of plasma computer modeling will be presented.
An overview of personal experience with laser-induced plasma (LIP) will be given. The combination of LIP with laser-induced fluorescence, atomic absorption, Raman spectroscopy and spatial heterodyne spectroscopy for elemental and isotopic analysis will be discussed. Unusual applications of LIP will be covered, such as LIP-based lasers and LIP-based chemical reactors.
In situ chemical analysis of duplex stainless steel weld by laser induced breakdown spectroscopy
(2024)
The high corrosion resistance and good mechanical properties of duplex stainless steel (DSS) are due to its special chemical composition, which is a balanced phase ratio of ferrite (α) and austenite (γ). Many industrial applications require the integration of DSS components. For this, Gas tungsten arc welding (GTAW) is an excellent choice, as it allows an automated operation with high reproducibility. However, when the weld pool solidifies, critical ratios of α- and γ- phases can occur, which lead to solidification cracking, increased susceptibility to corrosion, and a decrease in ductility and critical strength. Previous studies have shown that these defects can be caused by the accumulation of manganese and chromium in the heat affected zone (HAZ), requiring ongoing monitoring of this accumulation. A suitable method for such monitoring is laser-induced breakdown spectroscopy (LIBS), which can be used in two operating modes: calibration using standard reference samples and calibration-free. Unlike conventional quantitative LIBS measurements, which require reference samples to generate a calibration curve, calibration-free LIBS (CF-LIBS) allows chemical compositions to be determined solely from the emission spectrum of the plasma. Numerous publications show that CF-LIBS is a fast and efficient analytical method for the quantitative analysis of metal samples. In this work, CF-LIBS is applied to spectra obtained during GTAW DSS welding and the result is compared with those obtained by PLS analysis. A good correlation was found between both types of analysis, demonstrating the suitability of the CF-LIBS method for this application. The CF-LIBS method has a significant advantage over conventional LIBS due to the rapid in situ measurement of concentrations of major alloying elements without calibration procedure. This, combined with fast feedback and appropriate adjustment of welding parameters, helps prevent welding defects.
Concrete structures experience severe damage during service, for example due to pitting corrosion of rebars caused by the ingress of chlorine (Cl) into the porous concrete structure. The ingress can be monitored using laser-induced breakdown spectroscopy (LIBS), a recently introduced civil engineering technique used to detect Cl in concrete structures in addition to conventional wet chemistry methods. The key advantages of LIBS are high spatial resolution, which is important when analyzing heterogeneous concrete samples, as well as the almost complete absence of sample preparation. To assess LIBS as a reliable analytical method, its accuracy and robustness must be carefully tested. This paper presents the results of an interlaboratory comparison on the analysis of Cl in cement paste samples conducted by 12 laboratories in 10 countries. Two sets of samples were prepared with Cl content ranging from 0.06 to 1.95 wt% in the training set and 0.23–1.51 wt% in the test set, with additional variations in the type of cement and Cl source (salt type). The overall result shows that LIBS is suitable for the quantification of the studied samples: the average relative error was generally below 15%. The results demonstrate the true status quo of the LIBS method for this type of analysis, given that the laboratories were not instructed on how to perform the analysis or how to process the data.
The combination of acoustically levitated droplets, mid-IR laser evaporation, and subsequent post-ionization by secondary electrospray ionization was applied for monitoring the enzymatic digestion of various proteins. Acoustically levitated droplets are an ideal, wall-free model reactor, readily allowing compartmentalized microfluidic trypsin digestions. Time-resolved interrogation of the droplets yielded real-time information on the progress of the reaction and thus provided insights into reaction kinetics. After 30 min of digestion in the acoustic levitator, the obtained protein sequence coverages were identical to the reference overnight digestions. Importantly, our results clearly demonstrate that the applied experimental setup can be used for the real-time investigation of chemical reactions. Furthermore, the described methodology only uses a fraction of the typically applied amounts of solvent, analyte, and trypsin. Thus, the results exemplify the use of acoustic levitation as a green analytical chemistry alternative to the currently used batch reactions.
The generation of ozone and nitrogen oxides by laser-induced dielectric breakdown (LIDB) in mixtures of air with noble gases Ar, He, Kr, and Xe is investigated using OES and IR spectroscopy, mass spectrometry, and absorption spectrophotometry. It is shown that the formation of NO and NO2 noticeably depends on the type of inert gas; the more complex electronic configuration and the lower ionization potential of the inert gas led to increased production of NO and NO2. The formation of ozone occurs mainly due to the photolytic reaction outside the gas discharge zone. Equilibrium thermodynamic analysis showed that the formation of NO in mixtures of air with inert gases does not depend on the choice of an inert gas, while the equilibrium concentration of the NO+ ion decreases with increasing complexity of the electronic configuration of an inert gas.
The aim of the project is to develop an adequate model of laser induced plasma for conditions expected in space missions, i.e., vacuum, or low-pressure CO2 atmosphere. Numerical modeling will help to find optimal experimental parameters for the laser ablation under artificial lunar or Martian environments and obtain both qualitative, in terms of a composition, and quantitative, in terms of an elemental abundance, information about interrogated samples based on spectral data generated by the model. The best operational conditions will be found at a low cost without conducting tedious and time-consuming optimization experiments. The modeling approaches will be supported by machine learning to accelerate the optimization.
Improved Data Processing for Accurate Plasma Diagnostics with Implications for Calibration-Free LIBS
(2023)
Many LIBS papers report the determination of plasma temperature using the Boltzmann plot method or the determination of electron density using the Stark line broadening relation. This requires measuring the integrated intensities of the spectral lines and the linewidth under the assumption of optical thinness. It is taken for granted that this can be easily done either by working with the raw spectra or by fitting the appropriate function to the observed spectral lines. However, extracting the necessary information from raw spectral data is not as easy as it might seem. The quality of such extraction will depend to a decisive extent on the type of spectral instrument used. The spectrum emitted by the plasma is distorted by the device; an example is shown in Fig. 1. The elimination of this distortion belongs to the class of inverse problems, the successful solution of which fundamentally depends on the quality of the available information. When it comes to spectroscopy, the quality of information primarily means high spectral resolution and low noise. Not all spectrometers used in LIBS can provide the quality needed to solve the inverse problem; this casts doubt on many published plasma measurements. This communication will be devoted to the general shortcomings of spectral data processing and the inaccuracies in determining the plasma parameters resulting from these shortcomings. The analysis is based on the use of synthetic spectra generated by plasma with known temperature, particle density and electron density. The estimation of errors caused by inadequate processing of spectral data is made by comparing the initial and measured plasma parameters from the spectra. Recommendations will be made for which analytic function best approximates the observed spectral lines, and how data processing errors affect the accuracy of calibration-free LIBS will be discussed. These issues were only partially covered in previously published works, for example [1, 2].