1.1 Anorganische Spurenanalytik
Filtern
Dokumenttyp
- Zeitschriftenartikel (134)
- Vortrag (123)
- Posterpräsentation (56)
- Buchkapitel (2)
- Beitrag zu einem Tagungsband (2)
- Sonstiges (2)
- Forschungsdatensatz (2)
- Dissertation (1)
- Zeitschriftenheft (Herausgeberschaft für das komplette Heft) (1)
Sprache
- Englisch (297)
- Deutsch (25)
- Mehrsprachig (1)
Schlagworte
- ICP-MS (48)
- Laser ablation (34)
- HR-CS-GFMAS (28)
- Traceability (28)
- Nanoparticle (27)
- PFAS (26)
- Metrology (25)
- LA-ICP-MS (19)
- Absolute isotope ratio (18)
- Imaging (17)
- Uncertainty (15)
- Cell (14)
- Isotope ratio (14)
- Fluorine (13)
- Copper (12)
- Bioimaging (11)
- Isotope dilution (11)
- Reference material (11)
- Measurement uncertainty (10)
- HR-CS-MAS (9)
- Nanoparticles (9)
- Isotope dilution mass spectrometry (8)
- Magnesium (8)
- SI traceability (8)
- Single cell (8)
- Single cell analysis (8)
- Delta value (7)
- Extractable organically bound fluorine (EOF) (7)
- Fluorescence (7)
- High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) (7)
- Sc-ICP-ToF-MS (7)
- Soil (7)
- Speciation analysis (7)
- Cement (6)
- Isotope reference material (6)
- MC-ICP-MS (6)
- Mass spectrometry (6)
- Per- and polyfluorinated alkyl substances (PFASs) (6)
- Sulfur (6)
- Calibration (5)
- Conventional isotope ratio (5)
- Immunohistochemistry (5)
- Isotope (5)
- Isotope amount ratio (5)
- Isotope analysis (5)
- Isotope fractionation (5)
- Isotopic analysis (5)
- Lanthanide (5)
- Method development (5)
- Microbiological influenced corrosion MIC (5)
- Single cell-ICP-ToF-MS (5)
- Triple isotope fractionation (5)
- Capillary electrophoresis (4)
- Comparability (4)
- Diatoms (4)
- Human serum (4)
- Hyphenated techniques (4)
- Isotope delta value (4)
- LC-MS/MS (4)
- Labeling (4)
- Lithium (4)
- Magnetic resonance imaging (4)
- Mass cytometry (4)
- Microbiologically influenced corrosion (4)
- Quantification (4)
- SC-ICP-ToF-MS (4)
- SPM (4)
- Solid-liquid extraction (4)
- Adsorbable organically bound fluorine (AOF) (3)
- Analytical Chemistry (3)
- Archaea (3)
- BFR (3)
- Bioconjugation (3)
- Brain (3)
- Carbon steel corrosion (3)
- Cells (3)
- Circular economy (3)
- Combustion Ion Chromatography (3)
- Combustion ion chromatography (CIC) (3)
- Delta scale (3)
- Delta values (3)
- Gadolinium (3)
- ICP-ToF-MS (3)
- Immunoassay (3)
- Interlaboratory comparison (3)
- Ir DNA staining approach (3)
- Iron (3)
- Isotope ratios (3)
- LC-HRMS (3)
- LIBS (3)
- Laser Ablation (3)
- Machine learning (3)
- Mercury (3)
- Metrology in chemistry (3)
- Molar mass (3)
- Multicollector-ICP-MS (3)
- Nanocrystal (3)
- Per- and Polyfluoroalkyl substances (PFAS) (3)
- SPE (3)
- SPE HR-CS GF MAS (3)
- Seawater (3)
- Sediment (3)
- Sewage sludge (3)
- Spectrometry (3)
- Umweltsimulation (3)
- WWTP (3)
- XRF (3)
- 150th anniversary (2)
- ABC (2)
- AF4 (2)
- Affinity chromatography (2)
- Analysis (2)
- Analytical sciences (2)
- Antibody (2)
- Atomic absorption spectrometry (2)
- Atomic weight (2)
- BAM (2)
- Biodiesel fuel (2)
- Bundesanstalt für Materialforschung und -prüfung (2)
- Böden (2)
- CCQM (2)
- CE/MC-ICP-MS (2)
- CIC (2)
- Cancer (2)
- Cleaning (2)
- Collection (2)
- Contrast agent (2)
- Corophium volutator (2)
- Diagenesis (2)
- EOF (2)
- Editorial (2)
- Environment (2)
- Environmental simulation (2)
- Environmental speciation (2)
- Extrahierbar organisch gebundenes Fluor (EOF) (2)
- Fertilizer (2)
- Finow Canal (2)
- Fluor (2)
- Fluorination (2)
- General Earth and Planetary Sciences (2)
- Geological material (2)
- Glow Discharge Mass Spectrometry (2)
- History of the research work of Norbert Jakubowski (2)
- ICP-TOF-MS (2)
- IDMS (2)
- ILC (2)
- Immuno-assay (2)
- Inductively Coupled Plasma Mass Spectrometry (2)
- Isotope Dilution (2)
- Isotope delta (2)
- Isotope reference materials (2)
- Isotopes (2)
- Isotopic fractionation (2)
- Jahrestag (2)
- LA-ICP-MS with cellular resolution (2)
- Legacy pollution (2)
- Life sciences (2)
- Limit of detection (2)
- MDG (2)
- MRI (2)
- Magnesium isotope ratios (2)
- Material sciences (2)
- Metal toxicity (2)
- Metal uptake (2)
- Metalloprotein (2)
- Metals (2)
- Method (2)
- Methylmercury (2)
- Microdroplet generator (2)
- Mono-hydride (2)
- Multicellular spheroid (2)
- Multimodal (2)
- Nanomaterial (2)
- Nanomaterials (2)
- Nanopartikel (2)
- Nickel (2)
- Oberflächengewässer (2)
- Optical spectroscopy (2)
- PBFSM (2)
- Peptide (2)
- Peptide library (2)
- Pollutant (2)
- Pollutants (2)
- Polymer (2)
- Polypropylen (2)
- Polystyrol (2)
- Proteins (2)
- Provenance (2)
- Purity (2)
- Purity assessment (2)
- Quality assurance (2)
- RFA (2)
- SC-ICP-MS (2)
- SI (2)
- SI-traceability (2)
- Schadstoffaustrag (2)
- Schwebstoffe (2)
- Sensor (2)
- Serum (2)
- Silicon (2)
- Silver nanoparticles (2)
- Single Cell (2)
- Single cell ICP-MS (2)
- Single particle ICP-MS (2)
- Solid phase extraction (SPE) (2)
- Special issue (2)
- Speciation Analysis (2)
- Sr isotopes (2)
- Sum parameter (2)
- TCE (2)
- Tetramethylammonium hydroxide (2)
- Tissue (2)
- Transferrin (2)
- Umweltanalytik (2)
- Zinc (2)
- (Organisch gebundenes) Fluor-Summenparameter (1)
- 3D ultrastructural analysis (1)
- 6xHis (1)
- AAS (1)
- AOF (1)
- ATCUN (1)
- Absorption spectrometry (1)
- Adsorber (1)
- Affinity (1)
- Affinity enrichment (1)
- Affinity extraction (1)
- Alanine scan (1)
- Albumin (1)
- Algae (1)
- Algen (1)
- Algorithms (1)
- Alteration (1)
- Aluminum oxide (1)
- Alzheimer disease (1)
- Alzheimer’s disease (1)
- Amorphous Zinc phosphate (1)
- Amorphous phases (1)
- Amoxicillin (1)
- Amyloid-beta (1)
- Analytical chemistry (1)
- Anemia (1)
- Anti-cancer (1)
- Antifouling biocides (1)
- Antifouling-Biozide (1)
- Antikensammlung Berlin (1)
- Antikörpermarkierung (1)
- App (1)
- Archaeometry (1)
- Archean ocean (1)
- Argon (1)
- Array (1)
- Arsenite (1)
- Ash content (1)
- Atomic Absorption Spectrometry (1)
- Atomic Force Microscopy (1)
- Atomic weights (1)
- Automated single cell-ICP-ToF-MS (1)
- Automated system (1)
- Avogadro constant (1)
- Bacterial lysates (1)
- Battery (1)
- Bewitterung (1)
- Binding molecule (1)
- Bio-apatite (1)
- Bioapatite (1)
- Biodiesel (1)
- Biogenic carbonates (1)
- Biological boron recycling (1)
- Bioseparation (1)
- Blank characterization (1)
- Blood (1)
- Boron isotope (1)
- Boron isotope fractionation (1)
- Boron isotopic composition (1)
- Boron monohydride (1)
- Brassica napus (1)
- CE (1)
- CE-ICP-MS (1)
- CMC (1)
- CRM (1)
- Calcification (1)
- Calcium (1)
- Calcium monofluoride (1)
- Capecitabine (1)
- Capillary electrophoresis-mass spectrometry (1)
- Carbodiimide crosslinking (1)
- Carrier (1)
- Cconventional method (1)
- CeO2 (1)
- CellenONE (1)
- Cellular trafficking (1)
- Central Taurus (1)
- Certification (1)
- Cheese (1)
- Chelate (1)
- Chemometric (1)
- Chemometrie (1)
- Chemometrik (1)
- Chenopodium album (1)
- Chicken antibodies (1)
- Chromatography (1)
- Ciaaw.org (1)
- Cispaltin (1)
- Classical primary measurement method (CPM) (1)
- Climate (1)
- Cluster (1)
- Combinatorial chemistry (1)
- Complementary MS (1)
- Comsumer good samples (1)
- Confocal laser scanning microscopy (1)
- Conventional isotope ratios (1)
- Conventional method (1)
- Coparison study CIC <=> HR-CS-GFMAS (1)
- Corrosion (1)
- Counting detector (1)
- Cryo-soft X-ray tomography (1)
- Curse tablets (1)
- Cytoplasm (1)
- Cytoplasmic remodeling (1)
- Data processing (1)
- Degradation (1)
- Delta isotope standard (1)
- Dementia (1)
- Dendritic polyglycerol sulfate (1)
- Detector deadtime (1)
- Development (1)
- Diagnostics (1)
- Diatom (1)
- Diatom, Bacteria (1)
- Diatomeenanalytik (1)
- Diatomic molecule (1)
- Diffusion (1)
- Digestion (1)
- Dip-stick assay (1)
- Direct metal assay (1)
- Dissolution (1)
- Docking (1)
- Downstream processing (1)
- Dual mode detector (1)
- Dye (1)
- Dyes/pigments (1)
- EDTAD (1)
- ELISA (1)
- EPMA (1)
- ESI-MS (1)
- ETV/ICP-MS (1)
- Early Earth (1)
- Ecotoxicity (1)
- Ecotoxicological Assessment (1)
- Ecotoxicological Testing (1)
- Ecotoxicology testing (1)
- Einzelzellanalyse (1)
- Electrothermal Vaporization (1)
- Elemental analysis (1)
- Elemental composition (1)
- Elemental fingerprints (1)
- Elementspezies & Isotope (1)
- Environmental & life science application (1)
- Environmental analysis (1)
- Environmental pollutants (1)
- Environmental pollution monitoring (1)
- Equilibrium isotope fractionation (1)
- Escherichia coli (1)
- Ethylenediaminetetraacetic acid (1)
- Exposure (1)
- Extracellular matrix (1)
- Fe nanoparticles metabolism (1)
- Flame retardants (1)
- Flammschutzmittel (1)
- Fluorescence label (1)
- Fluoride (1)
- Fluorierte Organische Verbindungen (1)
- Fluorine Detection (1)
- Fluorine sum parameter (1)
- Fluorouracil (1)
- Fluoruos Systems (1)
- Food web (1)
- Fundamental science (1)
- GC/ICP-ToF-MS (1)
- GD-MS (1)
- GD-OES (1)
- GDMS (1)
- GF-MAS (1)
- Gadolinium-based contrast agents (GBCAs) (1)
- Galvanic anodes (1)
- Geochemistry (1)
- Geochemistry and Petrology (1)
- Geological thermometer (1)
- Geophysics (1)
- Glycosaminoglycan (1)
- Graphite furnace (1)
- Gravimtric isotope mixtures (1)
- Greek curse tablets (1)
- Green Deal (1)
- Group profile (1)
- Gypsum (1)
- HF free Digestion (1)
- HPLC-ICP-MS (1)
- HRMS (1)
- Hafnium (1)
- Heat flow (1)
- Heavy metals (1)
- HexaHis-Tag (1)
- High entropy alloy (1)
- High pH (1)
- High pressure experiments (1)
- High throughput (1)
- High-fired gypsum mortar (1)
- High-purity elements (1)
- High-resolution continuum source atomic absorption spectrometer (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- His6 (1)
- His8 (1)
- Hochauflösende continuum source-Graphitrohr Molekülabosprtionsspektrometrie (HR-CS-GFMAS) (1)
- Hochauflösende-continuum source Graphitrohr Molekülabsorptionsspektrometrie (HR-CS-GFMAS) (1)
- Hot-pressing (1)
- Hydrated silicate melts (1)
- Hydrodynamic chromatography (HDC) (1)
- Hydrogen (1)
- Hydrolysis (1)
- Hydrolysis products (1)
- Hydrothermal fluid (1)
- Hyphenated (1)
- IC (1)
- ICP (1)
- ICP-MS & HR-CS-GFMAS (1)
- ICP-MS/MS (1)
- ICP-OES (1)
- ICP-TOFMS (1)
- ID-MS (1)
- IMAC purification (1)
- IgY (1)
- Iinductively coupled plasma mass spectrometry (1)
- Imaging Mass Cytometry (1)
- Imaging mass cytometry (1)
- Immuno assay (1)
- Immuno-Assays (1)
- Immunoaffinity (1)
- Immunoaffinity extraction (1)
- Immunocapture (1)
- Immunofluorescence (1)
- Immunology (1)
- Impurity assessment (1)
- Impurity assessment approach (1)
- In situ (1)
- In vitro (1)
- In-house calibration solution (1)
- Inductively coupled plasma-mass spectrometry (1)
- Industrielle Analytik (1)
- Inflammation (1)
- Inorganic chemical analysis (1)
- Inorganic impurities (1)
- Instrumental isotope fractionation (1)
- Integrating sphere spectroscopy (1)
- Interferences (1)
- Iposomes (1)
- Iridium (1)
- Iron isotope fractionation (1)
- Iron isotopes (1)
- Iron nanoparticles (1)
- Iron oxide (1)
- Isotope mixtures (1)
- Isotope purification (1)
- Isotopic dilution (1)
- Isotopic shift (1)
- Kapillarelektrophorese-Massenspektrometrie (1)
- Kidney (1)
- Kilogram (1)
- Kinetic isotope fractionation (1)
- Komplementäre Massenspektrometrie (1)
- Kopplungstechniken (1)
- Kristallolgraphie (1)
- LA-(MC-)ICP-MS (1)
- LA/ICP-MS Imaging (1)
- LSVEC (1)
- Lab-on-a-chip (1)
- Lanthanide nanoparticle (1)
- Lanthanoid (1)
- Laser (1)
- Laser Ablation/Imaging (1)
- Laser ablation inductively coupled plasma–mass spectrometry imaging (LA-ICP-MSI) (1)
- Lead (1)
- Lead isotope composition (1)
- Lead isotope ratios (1)
- Lead isotope variations (1)
- Lead isotopes (1)
- Lifetime (1)
- Lightning talk (1)
- Lithium isotope (1)
- Lymnaea stagnalis (1)
- MALDI (1)
- MALDI-TOF MS (1)
- MC-TIMS (1)
- MDG ICP-ToF-MS (1)
- MIC (1)
- MS-ICP-MS (1)
- MST (1)
- MW-AES (1)
- Magnesium delta values (1)
- Magnesium monofluoride (1)
- Mammals (1)
- Mangesium (1)
- Massenspektrometrie (1)
- Material - Environment interaction (1)
- Matrix separation (1)
- Matrix-assisted laser desorption ionization–mass spectrometry imaging (MALDI-MSI) (1)
- Measurement space (1)
- Measuremment uncertainty (1)
- Medicinal application (1)
- Medium entropy alloy (1)
- Mercury speciation (1)
- Mesocosm (1)
- Mesoporous materials (1)
- Metal assay approach (1)
- Metal nanoclusters (1)
- Metal sublimation (1)
- Metal-Tag (1)
- Metal-tag (1)
- Methodenentwicklung (1)
- Metrology in Chemistry (1)
- Micro-sublimation (1)
- Microbially induced corrosion (1)
- Microplastic-induced effects (1)
- Microplatic (1)
- Migration (1)
- Mixture toxicity (1)
- Mobile phase (1)
- Mole (1)
- Molecular absorption spectrometry (1)
- Molecular imaging (1)
- Molecular spectrum (1)
- Multi-collector inductively coupled plasma-mass spectrometry (ICP-MS) (1)
- Multielementanalytik (1)
- Multielementanalytik in kurzen transienten Signalen (1)
- Multimodale Analytik (1)
- Multiple sclerosis (1)
- Multiple-injection sample-standard bracketing (1)
- Multivariate Datenauswertung (1)
- Multivariate analysis (1)
- NIR (1)
- Nano-carrier (1)
- Nanocluster (1)
- Nanomaterialien (1)
- Nanoparticle characterization (1)
- Nanorods (1)
- Nb2O5, NbO2F, Nb3O7F (1)
- Neodymium (1)
- New ecotoxicological testing tools (1)
- Nickel chelate (1)
- Nitrogen microwave inductively coupled atmospheric pressure mass spectrometry (1)
- Noise (1)
- Non-classical crystallization (1)
- Non-metal analysis (1)
- Non-target (1)
- North Sea (1)
- OBOC library (1)
- Oberflächenwasser (1)
- Oberflächenwasser und Boden (1)
- Old nanocrystal (1)
- On-chip screening (1)
- On-line CE/MC-ICP-MS (1)
- One-bead-one-compound library (1)
- Optical Spectroscopy (1)
- Optimization (1)
- Ordinary Portland cement (1)
- Ore provenance (1)
- Organically bound fluorine (1)
- Organophosphate esters (1)
- Organotin compounds (1)
- Oxygen evolution reaction (1)
- Oxygen isotope ratios (1)
- PARCI-MS (1)
- PFAS Analysis (1)
- PP (1)
- PS (1)
- Passivation (1)
- Pb isotopes (1)
- Peatlands (1)
- Peptide aptamers (1)
- Peptides and Proteins (1)
- Per- and polyfluorinated alkly substances (PFASs) (1)
- Phosphates (1)
- Phosphorus (1)
- Photocatalysis (1)
- Photocatalytic activity (1)
- Plant tissue (1)
- Plants (1)
- Plasma (1)
- Polarised light microscopy (1)
- Polishing (1)
- Pollution (1)
- Polyethylenimine (1)
- Polymer membrane (1)
- Pore fluids (1)
- Pore water quality (1)
- Portland cement (1)
- Portland clinker (1)
- Poster presentation (1)
- Priam's treasure (1)
- Primary calibration solution (1)
- Primary difference measurement method (PDM) (1)
- Primary transfer standards (PTSs) (1)
- Programmed cell death (1)
- Protein (1)
- Protein analysis (1)
- Protein g (1)
- Protein imaging (1)
- Provenancing (1)
- Prozessanalytik (1)
- Prozessindustrie (1)
- Pt-based drugs (1)
- PtNP (1)
- Purity determination (1)
- Quantitative protein analysis (1)
- Quantum dot (1)
- Quantum yield (1)
- Radiogenic isotopes (1)
- Raman microspectroscopy (1)
- Raman spectroscopy (1)
- Recombinant protein (1)
- Reference (1)
- Reference Materials (1)
- Reference data (1)
- Reference materials (1)
- Reference measurements (1)
- Reference procedure (1)
- Revision of the SI (1)
- Risk assessment (1)
- River water (1)
- River water sulfate (1)
- SDS-PAGE (1)
- SERS (1)
- SKPFM (1)
- SPR (1)
- SWIR (1)
- Sample-sample bracketing (1)
- Sapphire (1)
- Scale anchor (1)
- Scale conversion (1)
- Sedimente (1)
- Selenium (1)
- Shiny-App (1)
- Si isotope fractionation (1)
- Si isotopes (1)
- Silbernanopartikel (1)
- Silica diagenesis (1)
- Silver artefacts (1)
- Single Particle (1)
- Single cell-ICP-MS (1)
- Single particle-ICP-ToF-MS (1)
- Single-cell analysis (1)
- Single-particle (1)
- Smoldering fires (1)
- Software (1)
- Soil available boron (1)
- Soils (1)
- Spark plasma sintering (1)
- Special issue, young analytical scientists (1)
- Species-specific Isotope Analysis (1)
- Species-specific Isotope ratios (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrometer (1)
- Speroid (1)
- Spheroid (1)
- Sputtering (1)
- Sr and Nd isotope analysis (1)
- Sr isotope analysis (1)
- Stability (1)
- Stable isotopes (1)
- Standard addition (1)
- Standard atomic weight (1)
- Standardization (1)
- Statistical analysis (1)
- Statistics (1)
- Strontium (1)
- Strontium isotope (1)
- Strontium isotope ratio (1)
- Struvite (1)
- Sulfur isotopes (1)
- Sulfur quantification (1)
- Sulfur species conversion (1)
- Sulfur-copper-sepration (1)
- Sulfur-matrix separation (1)
- Sulphur isotope (1)
- Summenparameter Fluor (1)
- Surface plasmon resonance (1)
- Surface water (1)
- Surface waters (1)
- Surfacewaters (1)
- Synthetic isotope mixtures (1)
- Synthetic peptides (1)
- Tantalum oxyfluorides (1)
- Tau (1)
- Tau protein (1)
- Technology-critical elements (1)
- Terminology (1)
- Test strips (1)
- Thin tissue sections (1)
- Tissue soldering (1)
- Titanium hydride (1)
- Total element content (1)
- Total element determination (1)
- Toxic elements (1)
- Toxicity (1)
- Trace Elements (1)
- Transient signal (1)
- Transition metal (1)
- Trojan silver artefacts (1)
- Two-phase system (1)
- Umwelt-Speziation (1)
- Umweltprobenbank (1)
- Validate method (1)
- Validation (1)
- Value assignment (1)
- WD-XRF (1)
- Wadden Sea (1)
- Weathering (1)
- Wood chips (1)
- XPS (1)
- XRCD method (1)
- Xerogel (1)
- Ytterbium (1)
- Zirconium (1)
- bell pepper (1)
- boron (1)
- delta value (1)
- isotope fractionation (1)
- lank characterization (1)
- measurement uncertainty (1)
- metabolism (1)
- sc-ICP-ToF-MS (1)
- silicon (1)
- single cell-ICP-ToF-MS (1)
- single particle-ICP-ToF-MS (1)
- spICP-MS (1)
- species-specific isotope information (1)
- tandard addition (1)
- Ägyptisches Museum Berlin (1)
- β-lactam (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (323)
- 1.1 Anorganische Spurenanalytik (323)
- 1.8 Umweltanalytik (26)
- 4 Material und Umwelt (23)
- P Präsident (20)
- P.0 Präsident und andere (20)
- 1.6 Anorganische Referenzmaterialien (19)
- 1.7 Organische Spuren- und Lebensmittelanalytik (18)
- 1.4 Prozessanalytik (15)
- 4.1 Biologische Materialschädigung und Referenzorganismen (14)
Paper des Monats
- ja (4)
Eingeladener Vortrag
- nein (123)
Society for Applied Spectroscopy (SAS) Atomic Section Student Award.
Magnesium is a major element in the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg. It is due to their relatively large mass difference (~8% between) that isotope fractionation leads to slight variations of isotope amount ratios in biological, environmental and geological samples. Traditionally, isotope ratios are measured by mass spectrometric methods. Their drawbacks include the high costs for instruments and their operation, experienced operators and elaborate time-consuming chromatographic sample preparation.
Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS), and laser ablation molecular isotopic spectrometry (LAMIS).
For the determination of Mg isotope ratios in selected rock reference materials, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied and their results compared with MC-ICP-MS. By HR-CS-MAS, samples were dissolved by acid digestion and Mg isotopes analyzed with and without matrix. The absorption spectrum was recorded for MgF for the electronic transitions X 2Σ → A 2 Πi, and X 2Σ → B 2Σ+. In the case of LAMIS, we investigated the MgF molecule for the electronic transition A 2Πi → X 2Σ, as well as direct analysis by the MgO molecule for the electronic transition A 1Π+ → X 1Σ. The MgF and MgO spectra are described as the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO. The isotope analysis was done by deconvolution of the MgF spectrum by partial least square regression (PLS) calibrated with enriched isotope spikes. Results were accurate with precisions ranging between 0.2 ‰ and 0.8 ‰ (2 SD, n= 10) for HR-CS-GFMAS. No statistically significant differences were observed for samples w/o matrix extraction. On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of direct analysis, however the precision is lower due the lack of solid isotopic calibration standards.
Here, we describe a fast and simple extraction method for the determination of per- and polyfluorinated alkyl substances (PFASs) utilizing extractable organic fluorine (EOF) sum parameter analysis and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) in soil samples. After extraction and separation of inorganic and organic fluorinated compounds, organically bound fluorinated compounds were indirectly determined via the molecular absorption of gallium mono-fluoride at 211.248 nm. The implementation of the decisions of the “Stockholm Convention on persistent organic pollutants” as well as the “Protocol on Persistent Organic Pollutants of the Convention on Long-Range Transboundary Air Pollution” of the UNECE include the reduction respectively the elimination of PFASs in the environment. Currently, regulations aim to target single compounds (mostly C8-PFAS). But the PFAS group includes over 4700 substances, which are potentially persistent and toxic, thus target analytical approaches are not suitable for a holistic approach investigating the PFAS pollutant situation. Furthermore, forbidden PFASs are substituted by short-chain PFASs, thus the number of unknow substances is steadily increasing. For this reason, sum parameter approaches are more suitable to investigate and assess the pollution situation as well as derive exposure limits. Our developed analytical method was successfully applied to determine PFASs in soil samples from a polluted site. In view of steadily increasing numbers of PFAS substances, our method will make an important contribution in assessing the pollution situation as well as support policy makers in deriving exposure limits for PFAS in the future.
Per- and polyfluorinated alkyl substances (PFASs) are a substance class of over 4730 individual compounds. Several PFASs are extremely persistent, bioaccumulative and toxic. The analysis of PFASs is challenging because of their different chemical and physical properties as well as the high number of target substances. Target-based approaches (e.g., LC-MS/MS) are limited to the availability of analytical grade standards and are not suitable for the analysis of new/unknown PFASs and transformation products. Therefore, PFAS sum parameter methods become increasingly important to indicate a realistic PFAS pollution level.
PFAS sum parameters compromise the proportion of organically bound fluorine that can either be extracted (EOF) or adsorbed to activated carbon (AOF). For the instrumental analysis of such sum parameters, a fluorine selective detector is needed. High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) is a sensitive and highly selective tool for indirect fluorine determination. The method is based on the in situ formation of diatomic gallium-mono fluoride (GaF) in a graphite furnace at a temperature of 1550°C. The molecular absorption of GaF can be detected at its most sensitive wavelength at 211.248 nm providing limits of quantification of c(F) 2.7 µg/L.
Here, we describe a fast and simple extraction method for the determination of the EOF using HR-CS-GFMAS in soil samples. Common approaches for the EOF determination use solid phase extraction (SPE). To omit the bias of this time consuming and expensive step we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol. Comparison of the method with and without an SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. In the next step, the applicability of our method was tested for other solid matrices. In view of steadily increasing numbers of PFASs, our method will make an important contribution in assessing the pollution situation as well as support policy makers in deriving exposure limits for PFASs in the future.
Here, we describe a fast and simple extraction method for the determination of per- and polyfluorinated alkyl substances (PFASs) utilizing extractable organic fluorine (EOF) sum parameter analysis and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) in soil samples. After extraction and separation of inorganic and organic fluorinated compounds, organically bound fluorinated compounds were indirectly determined via the molecular absorption of gallium mono-fluoride at 211.248 nm. The implementation of the decisions of the “Stockholm Convention on persistent organic pollutants” as well as the “Protocol on Persistent Organic Pollutants of the Convention on Long-Range Transboundary Air Pollution” of the UNECE include the reduction respectively the elimination of PFASs in the environment. Currently, regulations aim to target single compounds (mostly C8-PFAS). But the PFAS group includes over 4700 substances, which are potentially persistent and toxic, thus target analytical approaches are not suitable for a holistic approach investigating the PFAS pollutant situation. Furthermore, forbidden PFASs are substituted by short-chain PFASs, thus the number of unknow substances is steadily increasing. For this reason, sum parameter approaches are more suitable to investigate and assess the pollution situation as well as derive exposure limits. Our developed analytical method was successfully applied to determine PFASs in soil samples from a polluted site. In view of steadily increasing numbers of PFAS substances, our method will make an important contribution in assessing the pollution situation as well as support policy makers in deriving exposure limits for PFAS in the future.
Here, we describe an optimized fast and simple extraction method for the determination of per- and polyfluorinated alkyl substances (PFASs) in soils utilizing high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR–CS–GFMAS). To omit the bias of the solid phase extraction (SPE) step commonly used during the analysis of extractable organically bound fluorine (EOF) we optimized a fast and simple SPE-free extraction method. The developed extraction method consists of a liquid-solid extraction using acidified methanol without any additional SPE. Four extraction steps were representative to determine a high proportion of the EOF (>80% of eight extractions). Comparison of the optimized method with and without an additional SPE clean-up step revealed a drastic underestimation of EOF concentrations using SPE. Differences of up to 94% were observed which were not explainable by coextracted inorganic fluoride. Therefore, not only a more accurate but also a more economic as well as ecologic method (bypassing of unnecessary SPE) was developed. The procedural limit of quantification (LOQ) of the developed method was 10.30 μg/kg which was sufficient for quantifying EOF concentrations in all tested samples. For future PFAS monitoring and potential regulative decisions the herein presented optimized extraction method can offer a valuable contribution.
A general method to carry out the fluorination of metal oxides with poly(tetrafluoroethylene) (PTFE, Teflon) waste by spark plasma sintering (SPS) on a minute scale with Teflon is reported. The potential of this new approach is highlighted by the following results. i) The tantalum oxyfluorides Ta3O7F and TaO2F are obtained from plastic scrap without using toxic or caustic chemicals for fluorination. ii) Short reaction times (minutes rather than days) reduce the process time the energy costs by almost three orders of magnitude. iii) The oxyfluorides Ta3O7F and TaO2F are produced in gram amounts of nanoparticles. Their synthesis can be upscaled to the kg range with industrial sintering equipment. iv) SPS processing changes the catalytic properties: while conventionally prepared Ta3O7F and TaO2F show little catalytic activity, SPS-prepared Ta3O7F and TaO2F exhibit high activity for photocatalytic oxygen evolution, reaching photoconversion efficiencies up to 24.7% and applied bias to photoconversion values of 0.86%. This study shows that the materials properties are dictated by the processing which poses new challenges to understand and predict the underlying factors.
The presence of microplastic (MP) particles in aquatic environments raised concern About possible enrichment of organic and inorganic pollutants due to their specific surface and chemical properties. In particular the role of metals within this context is still poorly understood. Therefore, the aim of this work was to develop a fully validated acid digestion protocol for metal analysis in different polymers, which is a prerequisite to study such interactions.
The proposed digestion protocol was validated using six different certified reference materials in the microplastic size range consisting of polyethylene, polypropylene, acrylonitrile butadiene styrene and polyvinyl chloride. As ICP-MS/MS enabled time-efficient, sensitive and robust analysis of 56 metals in one measurement, the method was suitable to provide mass fractions for a multitude of other elements beside the certified ones (As, Cd, Cr, Hg, Pb, Sb, Sn and Zn). Three different microwaves, different acid mixtures as well as different temperatures in combination with different hold times were tested for optimization purposes.
With the exception of Cr in acrylonitrile butadiene styrene, recovery rates obtained using the optimized protocol for all six certified reference materials fell within a range from 95.9% ± 2.7% to 112% ± 7%. Subsequent optimization further enhanced both precision and recoveries ranging from 103% ± 5% to 107 ± 4% (U; k = 2 (n = 3)) for all certified metals (incl. Cr) in acrylonitrile butadiene styrene. The results clearly show the analytical challenges that come along with metal analysis in chemically resistant plastics. Addressing specific analysis Tools for different sorption scenarios and processes as well as the underlying kinetics was beyond this study’s scope. However, the future application of the two recommended thoroughly validated total acid digestion protocols as a first step in the direction of harmonization of metal analysis in/on MP will enhance the significance and comparability of the generated data. It will contribute to a better understanding of the role of MP as vector for trace metals in the environment.
For the first time polyethylene (PE) frits were used to quantify sulphur in copper metal and its alloys by isotope dilution combined with LA-ICP-MS: an alternative approach for sample preparation. The properties of the PE frit meet the requirements for isotope dilution LA-ICPMS which are porous material, thermal and chemical resistance and high absorption efficiency. The breakthrough, however, as a support material, is the low sulphur blank, which is only two times of the gas flow blank (2.3-4.0 x 10⁴ cps). Additionally, the porosity of the frit was considered, as it directly affects the absorption efficiency for the sample solution, which is present in the cavities of the frit.
The absorption efficiency was studied by loading sulphur standards with varying sulphur amounts (0 - 80 µg S) onto the frits. The remaining sulphur which was not absorbed by the frit was rinsed off and was measured by ICP-MS. This indirect method shows that more than 99.5 % of the loaded sulphur was absorbed by the frit. The so prepared frits with increasing sulphur amount were measured by LA-ICP-MS showing a good linearity between 0 µg S and 40 µg S with a coefficient of determination, r2 of 0.9987 and a sensitivity of 3.4x10⁴ cps µgˉ¹ for 32S.
Three copper reference materials produced by BAM (BAM-M376a, BAM-228 and BAM-227) were selected to develop and validate the LA-ICP-IDMS procedure. The IDMS technique was applied to these samples as follows: the samples were spiked, dissolved, digested and then the digested solution was absorbed on the frits. The dried frit samples were then analyzed by LA-ICP-IDMS and it could be demonstrated that the sample solution dispersed on the frits did not influence the 32S/34S ratio significantly even though the sulphur intensities were fluctuating along the scan lines. Relative standard deviations of the isotope ratios were below 5 % in average between 3 lines (except for the pure spike solution and procedure blank). The measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS. Plotting the mass fraction of sulphur in copper obtained by LA-ICP-IDMS versus those obtained by ICP-IDMS yields a linear curve with a correlation coefficient of 0.9999 showing a strong agreement between both techniques.
The metrological traceability to the SI for the mass fraction of sulphur in copper is established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. The metrological traceability chain from the kg down to the final mass fraction in the samples obtained by LA-ICP-IDMS is illustrated in this presentation.
Polyethylene (PE) frits were used to quantify sulphur in copper and its alloys by isotope dilution combined with LA-ICP-MS as an alternative approach to conventional sample preparation: the copper samples were spiked, the spiked samples were dissolved, the resulting solutions were absorbed in the PE frits and finally the PE frits were analysed by LA-ICP-MS. A prerequisite for such a support material is a low sulphur blank and thus PE was selected for this purpose. The absorption efficiency of the PE frits was studied for varying sulphur amounts ranging from 2 mg S to 80 mg S showing that more than 99.5% of the loaded sulphur was absorbed by the frit. The so prepared PE frits were measured by LA-ICP-MS and yielded a good linearity (R2 ¼ 0.999) for the sulphur ion intensities corresponding to sulphur amounts up to 40 mg S; the associated sensitivity is approximately 3.4 x 10⁴ cps μg⁻¹ for ³²S. For the validation of the developed procedure the reference materials BAM-M376a, BAM-228 and BAM-227 were applied such that 2 μg S, 5 μg S and 11 μg S were absorbed in the PE frits, respectively. These samples were pre-quantified for the adsorbed sulphur amount by external calibration LA-ICP-MS yielding sulphur amounts of 0.9 μg, 5.1 μg and 8.5 μg (quantified for ³²S only), respectively. Relative Standard deviations of the isotope ratios were below 5% in average (n ¼ 3 lines) in all cases (except for the pure spike solution). These samples were then analysed by LA-ICP-IDMS and the measurement results were validated by comparing them with the results obtained by conventional ICP-IDMS. The obtained relative expanded measurement uncertainties ranged between 10% and 26%. Pearson's coefficient was used to express the correlation between both techniques; the obtained value was 0.999 demonstrating a strong correlation. Contrary to most published LA-ICP-IDMS procedures, the developed procedure enables SI-traceability for the measurement results. The metrological traceability to the SI for the sulphur mass fractions in copper was established by an unbroken chain of comparisons, each accompanied by an uncertainty budget. Thus, the measurement results are considered reliable, acceptable and comparable within the stated measurement uncertainty. The metrological traceability chain from the kg down to mass fraction in the samples obtained by LA-ICP-IDMS is presented as well.
Iron isotopes are used in a variety of fields from e.g., geologic question to medical applications. Measurements of iron isotopes are usually performed as delta measurements to an artificial based delta zero standard. In the case of Fe isotopes is that delta zero standard IRMM-014, a pure Fe metal. Unfortunately, that conventional delta zero reference material defining the 56/54Fe scale is out of stock and therefore unavailable. To overcome that situation and fulfill the need for laboratories that measure Fe isotope on a regular basis we will provide a set of solutions with IRMM-014 and a second anchor point for Fe isotope ratio measurements that is based on a pure Fe metal. This new second anchor point, a high purity Fe from BAM, will be calibrated against IRMM-014 and can be used as bracketing standard or as reference value for stable Fe isotope measurements.
We are in the good situation that BAM ordered a large stock of IRMM-014 several years ago. That stock of IRMM-014 Fe cubes and IRMM-014 Fe wires will be dissolved in 6M HCl in a large quantity. The new anchor point, the high purity Fe metal, that is commercially available at BAM, is a pure Fe metal with only trace amounts of impurities. The high purity BAM material will also be dissolved in 6M HCl in large quantity. Several aliquots of both solutions will be measured on the Neptune Plus MC-ICP-MS to define this second anchor point with a low uncertainty. Further will we send several aliquots of both solutions to different laboratories to also measure this second anchor point of high purity Fe on the 56/54Fe scale.
We will report the values of that study on BAM high purity Fe and will provide a guide for scale conversion to the IRMM-014 scale and for uncertainty calculation to use that new anchor point instead of the exhausted IRMM-014.