1 Analytische Chemie; Referenzmaterialien
Filtern
Dokumenttyp
- Zeitschriftenartikel (34) (entfernen)
Sprache
- Englisch (21)
- Deutsch (12)
- Mehrsprachig (1)
Schlagworte
- Prozessindustrie (7)
- Digitalisation (4)
- Industry 4.0 (4)
- Automation (3)
- CONSENS (3)
- Digitale Transformation (3)
- Modular Production (3)
- Process Analytical Technology (3)
- Process Industry (3)
- Artificial neural networks (2)
- Chemometrie (2)
- Digital Transformation (2)
- Lab of the Future (2)
- Metal−organic frameworks (2)
- NAMUR (2)
- Online NMR spectroscopy (2)
- Process analytical technology (2)
- Prozessanalytik (2)
- Real-time process monitoring (2)
- Smart sensors (2)
- Smarter Sensor (2)
- Aktorik (1)
- Artificial Neural Networks (1)
- Atomic and molecular physics, and optics (1)
- Automatisierung (1)
- Baustoffe (1)
- Benchtop NMR (1)
- Benchtop NMR Spectroscopy (1)
- Big Data (1)
- CCQM-K (1)
- Chemical Process Control (1)
- Chemometrik (1)
- Continuous Processes (1)
- Continuous processes (1)
- Cryoadsorption (1)
- Cyber-Physical Systems (1)
- Cyber-physical Lab (1)
- Cyber-physical system (1)
- Cyber-physical systems (1)
- DFT (1)
- Data Analysis (1)
- Data Fusion (1)
- Datenanalyse (1)
- Datenkonzepte (1)
- Digital Twins (1)
- Digital transformation (1)
- Digital twins (1)
- Digitalisierung (1)
- Digitalisierung der Prozessindustrie (1)
- Digitization of process industry (1)
- Escherichia coli (1)
- Flow Chemistry (1)
- Gasanalytik (1)
- Gasgualität (1)
- Gasreinheit (1)
- Gerätekommunikation (1)
- Hydrogen Storage (1)
- Hydrogen adsorption storage (1)
- IT-OT-Testplattform (1)
- Imidazole (1)
- Impfstoffe (1)
- In situ Raman (1)
- Indirect Hard Modeling (1)
- Industrie 4.0 (1)
- Industrielle Analytik (1)
- Industry 4.0, (1)
- Infrastruktur (1)
- Inline Analytics (1)
- Inline NMR Spectroscopy (1)
- Instrument Communication (1)
- Integrated Processes (1)
- Iterative real-time optimization (1)
- Kommunikation (1)
- Konnektivität (1)
- Kristallolgraphie (1)
- Künstlicher Intelligenz (1)
- Labor der Zukunft (1)
- Labor-IT (1)
- Laboratory 4.0 (1)
- Laborkommunikation (1)
- Large-scale processing (1)
- Lastwechsel (1)
- MOF´s (1)
- Mass Spectrometry (1)
- Mass spectrometry (1)
- Mechanochemistry (1)
- MefHySto (1)
- Metabolite quantification (1)
- Metrologie (1)
- Model Predictive Control (1)
- Modifier adaptation (1)
- Multielementanalytik (1)
- Multimodale Analytik (1)
- Multivariate data analysis (1)
- NAMUR Open Architecture (1)
- NIR (1)
- NIR Spectroscopy (1)
- NMR Spectroscopy (1)
- NOA (1)
- Normung (1)
- Nuclear Magnetic Resonance Spectroscopy (1)
- Nuclear magnetic resonance spectroscopy (1)
- OPC-UA (1)
- Online NMR Spectroscopy (1)
- PEM-Wasserelektrolyse (1)
- Partial Least Squares Regression (1)
- Pharmazeutische Produktion (1)
- Physical and theoretical chemistry (1)
- Physical twin (1)
- Plant-model mismatch (1)
- Powder X-ray diffraction (1)
- Process Analytical Tecnology (1)
- Process Control (1)
- Process industry (1)
- Process intelligence (1)
- Process sensors 4.0 (1)
- Prouess-Sensoren 4.0 (1)
- QI-Digital (1)
- Quality by Design (1)
- Qualitätssicherung (1)
- Reaction Monitoring (1)
- Reactor control (1)
- Real-time quality control (1)
- Recycling (1)
- Regel- und Messtechnik (1)
- Rückverstromung (1)
- Salicylic acid (1)
- Salts (1)
- Sensorik (1)
- Smart Laboratoy (1)
- Smart Sensors (1)
- Smart actuators (1)
- Smart test laboratories (1)
- Smarte Aktoren (1)
- Smarte Sensoren (1)
- Smarter Aktor (1)
- SsNMR (1)
- Static Mixing (1)
- Surface-enhanced Raman spectroscopy (SERS) (1)
- Sustainable Production (1)
- Temperature Control (1)
- Thermal Process Engineering (1)
- Time-gated Raman (TG-Raman) (1)
- Tutzing Symposion (1)
- Tutzing-Symposion (1)
- Twin-screw extrusion (TSE) (1)
- Wasserstoff (1)
- Wasserstoff-Qualität (1)
- Wasserstoffspeicher (1)
- Wasserstofftankstelle (1)
- Wissenschaftskultur (1)
- ZIF-8 (1)
- Zertifikat (1)
- research landscape (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (34)
- 1.4 Prozessanalytik (33)
- 6 Materialchemie (3)
- 8 Zerstörungsfreie Prüfung (3)
- 6.0 Abteilungsleitung und andere (2)
- 6.3 Strukturanalytik (2)
- 8.0 Abteilungsleitung und andere (2)
- 8.6 Faseroptische Sensorik (2)
- 1.0 Abteilungsleitung und andere (1)
- 1.1 Anorganische Spurenanalytik (1)
Paper des Monats
- ja (1)
Establishing ZIF‐8 as a reference material for hydrogen cryoadsorption: An interlaboratory study
(2024)
AbstractHydrogen storage by cryoadsorption on porous materials has the advantages of low material cost, safety, fast kinetics, and high cyclic stability. The further development of this technology requires reliable data on the H2 uptake of the adsorbents, however, even for activated carbons the values between different laboratories show sometimes large discrepancies. So far no reference material for hydrogen cryoadsorption is available. The metal‐organic framework ZIF‐8 is an ideal material possessing high thermal, chemical, and mechanical stability that reduces degradation during handling and activation. Here, we distributed ZIF‐8 pellets synthesized by extrusion to 9 laboratories equipped with 15 different experimental setups including gravimetric and volumetric analyzers. The gravimetric H2 uptake of the pellets was measured at 77 K and up to 100 bar showing a high reproducibility between the different laboratories, with a small relative standard deviation of 3–4 % between pressures of 10–100 bar. The effect of operating variables like the amount of sample or analysis temperature was evaluated, remarking the calibration of devices and other correction procedures as the most significant deviation sources. Overall, the reproducible hydrogen cryoadsorption measurements indicate the robustness of the ZIF‐8 pellets, which we want to propose as a reference material.
Um die internationale Spitzenposition deutscher Unternehmen der Prozessindustrie auch in Zukunft sicher zu stellen, müssen die Unternehmen ihre Prozesse und Geschäftsabläufe digitalisieren und gemeinsam mit der Forschung innovative neue Methoden, Apparate, Anlagen, Sensoren und Automatisierungstechnik sowie Datenkonzepte entwickeln. All dies erfordert den Aufbau neuer Fähigkeiten, Investition in Talente, interdisziplinäre Kommunikation zwischen verschiedenen Personen und Abteilungen und eine Bereitschaft zur Veränderung.
Physical adsorption at cryogenic temperature (cryoadsorption) is a reversible mechanism that can reduce the pressure of conventional compressed gas storage systems. Metal–organic framework (MOF) materials are remarkable candidates due to the combination of high specific surface area and density which, in some cases, provide a high volumetric storage capacity. However, such extensive use of MOFs for this application requires the selection of affordable structures, easy to produce and made from feasible metallic and organic components. Herein, we introduce a MOF database detailing the crystallographic and porous properties of 3600 existing MOFs made from industrially relevant metals and their organic composition. The comparison of the available minimum costs of linkers allowed the creation of a database to select affordable structures with high potential for volumetric hydrogen storage by cryoadsorption, considering their composition based on individual or mixed building blocks. A user interface, available online, facilitates the selection of MOFs based on the properties or names of structures and linkers.
The application of compact NMR instruments to hot flowing samples or exothermically reacting mixtures is limited by the temperature sensitivity of permanent magnets. Typically, such temperature effects directly influence the achievable magnetic field homogeneity and hence measurement quality. The internal-temperature control loop of the magnet and instruments is not designed for such temperature compensation. Passive insulation is restricted by the small dimensions within the magnet borehole. Here, we present a design approach for active heat shielding with the aim of variable temperature control of NMR samples for benchtop NMR instruments using a compressed airstream which is variable in flow and temperature. Based on the system identification and surface temperature measurements through thermography, a model predictive control was set up to minimise any disturbance effect on the permanent magnet from the probe or sample temperature. This methodology will facilitate the application of variable-temperature shielding and, therefore, extend the application of compact NMR instruments to flowing sample temperatures that differ from the magnet temperature.
Optimizing the Green Synthesis of ZIF-8 by Reactive Extrusion Using In Situ Raman Spectroscopy
(2023)
We report the scale-up of a batch solid synthesis of zeolitic imidazolate framework-8 (ZIF-8) for reactive extrusion. The crystalline product forms in the extruder directly under the mixture of solid 2-methylimidazole and basic zinc carbonate in the presence of a catalytic amount of liquid. The process parameters such as temperature, liquid type, feeding rate, and linker excess were optimized using the setup specifically designed for in situ Raman spectroscopy. Highly crystalline ZIF-8 with a Brunauer–Emmett–Teller (BET) surface area of 1816 m2 g–1 was quantitatively prepared at mild temperature using a catalytic amount of ethanol and a small excess of the linker. Finally, we developed a simple and comprehensive approach to evaluating the environmental friendliness and scalability of metal–organic framework (MOF) syntheses in view of their large-scale production.
Cryoadsorption on the inner surface of porous materials is a promising solution for safe, fast, and reversible hydrogen storage. Within the class of highly porous metal−organic frameworks, zeolitic imidazolate frameworks (ZIFs) show high thermal, chemical, and mechanical stability. In this study, we selected ZIF-8 synthesized mechanochemically by twin-screw extrusion as powder and pellets. The hydrogen storage capacity at 77 K and up to 100 bar has been analyzed in two laboratories applying three different measurement setups showing a high reproducibility. Pelletizing ZIF-8 increases the packing density close to the corresponding value for a single crystal without loss of porosity, resulting in an improved volumetric hydrogen storage capacity close to the upper limit for a single crystal. The high volumetric uptake combined with a low and constant heat of adsorption provides ca. 31 g of usable hydrogen per liter of pellet assuming a temperature−pressure swing adsorption process between 77 K − 100 bar and 117 K − 5 bar. Cycling experiments do not indicate any degradation in storage capacity. The excellent stability during preparation, handling, and operation of ZIF-8 pellets demonstrates its potential as a robust adsorbent material for technical application in pilot- and full-scale adsorption vessel prototypes.
CCQM-K118 was an international key comparison on natural gas composition with two types of gases, i.e., a low calorific hydrogen-enriched natural gas and a high calorific LNG type of gas. There were 14 participating laboratories. The traveling standards (i.e., 14 mixtures each) were obtained from an external source and checked for homogeneity and stability before and after the participants' measurements at the two coordinating laboratories. The data evaluation was performed using a consensus value and a laboratory effect model. The results of the participants were benchmarked against a key comparison reference value computed from the largest consistent subset (LCS) of the submitted results, adjusted for the differences between the travelling standards. For the first time in a key comparison in gas analysis, the model included a term to account for excess variability in the LCS. Most of the participants reported one or a few (slightly) discrepant results. Partly this is due to the heterogeneity and heteroscedasticity of the datasets. In all, the results in this key comparison demonstrate the good comparability of the national measurement standards for natural gas composition maintained by the participating NMIs.
Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).
To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/.
The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
In dieser Arbeit werden die Grundlagen der Normung, die Entstehung einer Norm und die für die Gasanalytik relevanten Normungsgremien kurz dargestellt. Dazu werden die wichtigsten Normen zur Gasanalytik entlang des analytischen Prozesses gruppiert und aufgeführt. Schließlich wird als Anwendungsbeispiel aus der eigenen Praxis der Prozess von der Herstellung bis zur Zertifizierung eines Kalibriergases beschrieben.
Das europäische Projekt MefHySto befasst sich mit dem Bedarf an großmaßstäblichen Energiespeichern, die für eine Umstellung der Energieversorgung auf erneuerbare Energien erforderlich sind. Eine solche Speicherung ist entscheidend, um Energie zu Spitzenzeiten zu liefern, wenn die erneuerbaren Energiequellen schwanken. Eine mögliche Lösung für die Energiespeicherung ist der großtechnische Einsatz von Wasserstoff. Die messtechnische Rückführbarkeit in der Energieinfrastruktur für die Wasserstoffspeicherung ist dann von entscheidender Bedeutung und eine bessere Kenntnis der chemischen und physikalischen Eigenschaften von Wasserstoff sowie rückführbare Messungen und validierte Techniken unverzichtbar.
Mass Spectrometry (MS) and Nuclear Magnetic Resonance Spectroscopy (NMR) are critical components of every industrial chemical process as they provide information on the concentrations of individual compounds and by-products. These processes are carried out manually and by a specialist, which takes a substantial amount of time and prevents their utilization for real-time closed-loop process control. This paper presents recent advances from two projects that use Artificial Neural Networks (ANNs) to address the challenges of automation and performance-efficient realizations of MS and NMR. In the first part, a complete toolchain has been developed to develop simulated spectra and train ANNs to identify compounds in MS. In the second part, a limited number of experimental NMR spectra have been augmented by simulated spectra to train an ANN with better prediction performance and speed than state-of-theart analysis. These results suggest that, in the context of the digital transformation of the process industry, we are now on the threshold of a possible strongly simplified use of MS and MRS and the accompanying data evaluation by machine-supported procedures, and can utilize both methods much wider for reaction and process monitoring or quality control.