P Präsident
Filtern
Dokumenttyp
- Zeitschriftenartikel (32)
- Vortrag (13)
- Posterpräsentation (10)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- HR-CS-MAS (6)
- Laser-induced plasma (6)
- Isotope analysis (5)
- Laser ablation (5)
- Mass Spectrometry (5)
- ICP-MS (4)
- Lithium (4)
- Machine learning (4)
- Magnesium (4)
- Analytical Sciences (3)
- Battery (3)
- DPSS laser (3)
- LIBS (3)
- Lithium isotope (3)
- Mass spectrometry (3)
- Traceability (3)
- Abwasser (2)
- Ambient mass spectrometry (2)
- Atomic absorption spectrometry (2)
- Bioconjugation (2)
- Bisphenol A (2)
- Cells (2)
- Characterization (2)
- Copper (2)
- Diatomic molecule (2)
- Digital transformation (2)
- ELISA (2)
- Graphite furnace (2)
- Immunoassay (2)
- Isotope (2)
- Isotope dilution (2)
- LC-MS/MS (2)
- Laser (2)
- Laser-spark (2)
- MC-ICP-MS (2)
- Optical spectroscopy (2)
- Photodegradation (2)
- Photooxidation (2)
- Spectroscopy (2)
- Sulfur (2)
- Uncertainty (2)
- Validierung (2)
- AAS (1)
- ABC (1)
- Absorption spectrometry (1)
- Acoustic levitation (1)
- Acoustical Levitation (1)
- Africa (1)
- Airborne (1)
- AlCl (1)
- Algorithms (1)
- Alloys (1)
- Ambient Desorption/Ionization (1)
- Ambient Ionization (1)
- Ambient desorption/ionization (1)
- Ambient ionization (1)
- Ambient pressure laser ionization (1)
- Anemia (1)
- Array (1)
- Atmospheric Pressure Chemical Ionization (1)
- Atomic Absorption Spectrometry (1)
- Atomic spectrometry (1)
- Autonomous chemistry (1)
- BODIPY dyes (1)
- Behavior (1)
- Boronic acid (1)
- Brunauer-Emmett-Teller (1)
- Calcium monofluoride (1)
- Calibration (1)
- Cell (1)
- Chemometric (1)
- Chemometrics (1)
- Chlorides (1)
- Chlorine (1)
- Cluster (1)
- Concrete (1)
- DPSS-laser (1)
- Diffusion (1)
- Digital (1)
- Dissolution (1)
- Duplex (1)
- EC/MS (1)
- ESR (1)
- Embrittlement (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Fe nanoparticles metabolism (1)
- Fenton (1)
- Ferritic steels (1)
- Fluorescence (1)
- Fragmentation activation (1)
- Fungicide (1)
- GDMS (1)
- Geological thermometer (1)
- Germanium sulfide (1)
- HPLC-ICP-MS (1)
- HR-CS-AAS (1)
- HRMS (1)
- Heavy crude oil (1)
- High repetition rate (1)
- High-resolution absorption isotopic spectrometry (1)
- High-resolution continuum source atomic absorption spectrometer (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hormone (1)
- Human serum (1)
- Hydrodynamic chromatography (HDC) (1)
- IDMS (1)
- In situ (1)
- In vitro (1)
- Industry 4.0 (1)
- Ionmobility spectrometry (1)
- Iposomes (1)
- Iron nanoparticles (1)
- Katalysator (1)
- LA-ICP-MS (1)
- Laser Desorption (1)
- Laser-Induced Plasma (1)
- Laser-spark ionization (1)
- MS-ICP-MS (1)
- Magnetic nanocatalyst (1)
- Magnetpartikel (1)
- Matrix (1)
- Matrixeffekte (1)
- Metals (1)
- Microemulsion (1)
- Microfluidic (1)
- Microfluidics (1)
- Molecular spectrum (1)
- Mukuru (1)
- Multivariate analysis (1)
- Nano-carrier (1)
- Nanon (1)
- Nanoparticle (1)
- Nanoparticle characterization (1)
- Nanoparticles (1)
- Oberflächenwasser (1)
- Online NMR spectroscopy (1)
- Optical emission spectroscopy (1)
- Oxidative metabolism (1)
- Peptide library (1)
- Pesticide (1)
- Plasma (1)
- Polymerwissenschaften (1)
- Process analytical technology (1)
- Process industry (1)
- Public funding (1)
- Purity (1)
- Quality assurance (1)
- Quantification (1)
- Quantum state (1)
- Reaction dynamics (1)
- Reference (1)
- Reference material (1)
- Reference materials (1)
- SEM (1)
- SI (1)
- Single particle ICP-MS (1)
- Singulettsauerstoff (1)
- Sonochemical synthesis (1)
- SpICP-MS (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrochemical analysis (1)
- Spectrometer (1)
- Spectrometry (1)
- Strain rates (1)
- Sugars (1)
- Surface chemistry (1)
- Sustainability (1)
- TEM (1)
- Tandem MS (1)
- Thermal-desorption spectroscopy (1)
- Titanium (1)
- Transformation products (1)
- Ultrasonic Levitation (1)
- Ultrasonic acoustic resonator (1)
- Urban planning (1)
- Vacuum ultraviolet (VUV) light (1)
- Validation (1)
- Wastewater (1)
- Water (1)
- Xerogel (1)
- Zirconium (1)
- ion optics (1)
Organisationseinheit der BAM
- P Präsident (56)
- 1 Analytische Chemie; Referenzmaterialien (49)
- P.0 Präsident und andere (43)
- 1.1 Anorganische Spurenanalytik (20)
- 1.3 Instrumentelle Analytik (18)
- 1.6 Anorganische Referenzmaterialien (15)
- PST Präsidiale Stabsstelle (15)
- 1.9 Chemische und optische Sensorik (12)
- 6 Materialchemie (11)
- 6.3 Strukturanalytik (7)
The therapeutic dose of lithium (Li) compounds, which are widely used for the treatment of psychiatric and hematologic disorders, is close to its toxic level; therefore, drug monitoring protocols are mandatory. Herein, we propose a fast, simple, and low-cost analytical procedure for the traceable determination of Li concentration in human serum, based on the monitoring of the Li isotope dilution through the partially resolved isotope shift in its electronic transition around 670.80 nm using a commercially available high-resolution continuum source graphite furnace atomic absorption spectrometer. With this technique, serum samples only require acidic digestion before analysis. The procedure requires three measurements—an enriched 6Li spike, a mixture of a certified standard solution and spike, and a mixture of the sample and spike with a nominal 7Li/6Li ratio of 0.82. Lanthanum has been used as an internal spectral standard for wavelength correction. The spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Both the spectral constants and the correlation between isotope ratio and relative band intensity have been experimentally obtained using commercially available materials enriched with Li isotopes. The Li characteristic mass (mc) obtained corresponds to 0.6 pg. The procedure has been validated using five human serum certified reference materials. The results are metrologically comparable and compatible to the certified values. The measurement uncertainties are comparable to those obtained by the more complex and expensive technique, isotope dilution mass spectrometry.
Mass spectrometric Methods MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
Optical spectrometric methods are proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS) and laser ablation molecular isotopic spectrometry (LAMIS). First, stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated heteronuclear diatomic molecules (MH or MX) in graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. Finally, the application of molecular spectrometry via emission by LAMIS is compared and discussed.
The meeting was organised by the European Commission’s Joint Research Centre and held at the JRC-Geel site on 22–23 February 2018. It was a follow-up of a similar meeting held in 2009. The objective of the meeting was to exchange information about ongoing publicly funded reference material (RM) production, identify areas of interest for future specific RMs, including certified reference material (CRM) developments, investigate potential areas of collaboration, and to identify areas which may be of a lower importance in the future for a specific RM producer. The benefit of exchanging such information is to avoid duplication of efforts in RM production, make better use of public funds by potentially matching competencies, and to address problems that are common to publicly funded RM producers.
Optical elemental analysis in the gas phase typically relies on electrically driven plasmas. As an alternative approach, laser-induced plasmas (LIPs) have been suggested but have so far been only scarcely used.
Here, a novel signal enhancement strategy for laser-based airborne plasma optical Emission spectroscopy for gas phase analytics is presented. In contrast to an electrically driven plasma, in the laser-induced analogue dynamic matter transport equilibrium builds up. The latter results in a rarefied density regime in the plasma core itself, surrounded by an area of compressed matter. The central rarefaction leads to a decrease in plasma intensity and analyte number density, both of which are detrimental for analytical purposes. Since the repetitive ignition of LIPs is a transient process, a restoration of the former gaseous medium by other dynamically equilibrated diffusion processes would be favourable. The presented combination of an airborne LIP and an ultrasonic acoustic resonator yields a fourfold signal enhancement while the Background contribution of ubiquitous air is at the same time effectively suppressed. Since the entire enhancement effect occurs without contact, no additional sources for abrasive sample contamination are introduced.
Magnesium is a major element in the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg. It is due to their relatively large mass difference (~8% between) that isotope fractionation leads to slight variations of isotope amount ratios in biological, environmental and geological samples. Traditionally, isotope amount ratios are measured by mass spectrometric methods. Their drawbacks include the high costs for instruments and their operation, experienced operators and elaborate time-consuming chromatographic sample preparation. Recently, an optical spectrometric method has been proposed as faster and low-cost alternative for the analysis of isotope ratios: high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS).
For the determination of Mg isotope ratios in selected rock reference materials, the high-resolution molecular absorption spectrum of in-situ generated MgF molecule was studied applying multivariate analysis and the results compared with MC-ICP-MS. Samples were dissolved by acid digestion and Mg isotopes analyzed with and without matrix. The absorption spectra were recorded for MgF for the electronic transition X 2Σ → B 2Σ+. The MgF spectrum is described as the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF. The isotope analysis was done by deconvolution of the MgF spectrum by partial least square regression (PLS). A PLS model was built and calibrated with enriched isotope spikes and certified reference materials. Spectra data was preprocessed by a derivate of second order and venetian blinds cross-validation was employed for finding the optimum latent variables. Finally, the model was refined by a genetic algorithm which identified the best subset of variables for a precise and accurate regression. Results are compatible with those obtained by MC-ICP-MS with an accuracy of ± 0.3‰ with uncertainties ranging between 0.02 to 0.6‰.
Arraying of single cells for mass spectrometric analysis is a considerable bioanalytical challenge. In this study, we employ a novel single cell arraying technology for quantitative analysis and isotopic fingerprinting by laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS). The single cell arraying approach is based on a piezo-acoustic microarrayer with software for automated optical detection of cells within the piezo dispense capillary (PDC) prior to arraying. Using optimized parameters, single cell occupancy of >99%, high throughput (up to 550 cells per hour), and a high cell recovery of >66% is achieved. LA-ICP-TOF-MS is employed to detect naturally occurring isotopes in the whole mass range as fingerprints of individual cells. Moreover, precise quantitative determination of metal-containing cell dyes is possible down to contents of ∼100 ag using calibration standards which were produced using the same arrayer.
An alternative method for lithium isotope analysis by using high-resolution atomic absorption spectrometry (HR-CS-AAS) is proposed herein. This method is based on monitoring the isotope shift of approximately 15 pm for the electronic transition 22P←22S at around the wavelength of 670.8 nm, which can be measured by state-of-the-art HR-CS-AAS. Isotope analysis can be used for (i) the traceable determination of Li concentration and (ii) isotope amount ratio analysis based on a combination of HR-CS-AAS and spectral data analysis by machine learning (ML).
In the first case, the Li spectra are described as the linear superposition of the contributions of the respective isotopes, each consisting of a spin-orbit doublet, which can be expressed as Gaussian components with constant spectral position and width and different relative intensity, reflecting the isotope ratio in the sample. Precision was further improved by using lanthanum as internal spectral standard. The procedure has been validated using human serum-certified reference materials. The results are metrologically comparable and compatible with the certified values.
In the second case, for isotope amount ratio analysis, a scalable tree boosting ML algorithm (XGBoost) was employed and calibrated using a set of samples with 6Li isotope amount fractions ranging from 0.06 to 0.99 mol mol−1. The training ML model was validated with certified reference materials. The procedure was applied to the isotope amount ratio determination of a set of stock chemicals and a BAM candidate reference material NMC111 (LiNi1/3Mn1/3Co1/3O2), a Li-battery cathode material. These determinations were compared with those obtained by MC-ICP-MS and found to be metrologically comparable and compatible. The residual bias was −1.8‰, and the precision obtained ranged from 1.9‰ to 6.2‰. This precision was sufficient to resolve naturally occurring variations. The NMC111 cathode candidate reference material was analyzed using high-resolution continuum source atomic absorption spectrometry with and without matrix purification to assess its suitability for technical applications. The results obtained were metrologically compatible with each other.
Because of the globally increasing prevalence of diabetes, the need for accurate, efficient and at best miniaturized automated analytical systems for sugar detection in medical diagnostics and the food industry is still urgent. The development of molecular probes for sugars based on boronic acid receptors offers an excellent alternative to the kinetically slow enzyme-based sugar sensors. Moreover, by coupling such chelating units with dye scaffolds like BODIPYs (boron–dipyrromethenes), highly fluorescent sugar sensing schemes can be realized. In this work, a boronic acid-functionalized BODIPY probe was developed, which binds selectively to fructose’s adjacent diols to form cyclic boronate esters. Placement of an amino group in direct neighborhood of the boronic acid moiety allowed us to obtain a broad working range at neutral pH, which distinguishes the probe from the majority of systems working only at pH > 8, while still meeting the desired sensitivity in the micro-molar range due to a pronounced analyte-induced fluorescence increase. To enhance the applicability of the test in the sense described above, integration with a microfluidic chip was achieved. Here, fructose was selectively detected by fluorescence with similar sensitivity in real time on chip, and an assay for the straightforward detection of sugar in (colored) sodas without sample clean-up was established.