P Präsident
Filtern
Dokumenttyp
- Zeitschriftenartikel (32)
- Vortrag (13)
- Posterpräsentation (10)
- Beitrag zu einem Tagungsband (1)
Schlagworte
- HR-CS-MAS (6)
- Laser-induced plasma (6)
- Isotope analysis (5)
- Laser ablation (5)
- Mass Spectrometry (5)
- ICP-MS (4)
- Lithium (4)
- Machine learning (4)
- Magnesium (4)
- Analytical Sciences (3)
- Battery (3)
- DPSS laser (3)
- LIBS (3)
- Lithium isotope (3)
- Mass spectrometry (3)
- Traceability (3)
- Abwasser (2)
- Ambient mass spectrometry (2)
- Atomic absorption spectrometry (2)
- Bioconjugation (2)
- Bisphenol A (2)
- Cells (2)
- Characterization (2)
- Copper (2)
- Diatomic molecule (2)
- Digital transformation (2)
- ELISA (2)
- Graphite furnace (2)
- Immunoassay (2)
- Isotope (2)
- Isotope dilution (2)
- LC-MS/MS (2)
- Laser (2)
- Laser-spark (2)
- MC-ICP-MS (2)
- Optical spectroscopy (2)
- Photodegradation (2)
- Photooxidation (2)
- Spectroscopy (2)
- Sulfur (2)
- Uncertainty (2)
- Validierung (2)
- AAS (1)
- ABC (1)
- Absorption spectrometry (1)
- Acoustic levitation (1)
- Acoustical Levitation (1)
- Africa (1)
- Airborne (1)
- AlCl (1)
- Algorithms (1)
- Alloys (1)
- Ambient Desorption/Ionization (1)
- Ambient Ionization (1)
- Ambient desorption/ionization (1)
- Ambient ionization (1)
- Ambient pressure laser ionization (1)
- Anemia (1)
- Array (1)
- Atmospheric Pressure Chemical Ionization (1)
- Atomic Absorption Spectrometry (1)
- Atomic spectrometry (1)
- Autonomous chemistry (1)
- BODIPY dyes (1)
- Behavior (1)
- Boronic acid (1)
- Brunauer-Emmett-Teller (1)
- Calcium monofluoride (1)
- Calibration (1)
- Cell (1)
- Chemometric (1)
- Chemometrics (1)
- Chlorides (1)
- Chlorine (1)
- Cluster (1)
- Concrete (1)
- DPSS-laser (1)
- Diffusion (1)
- Digital (1)
- Dissolution (1)
- Duplex (1)
- EC/MS (1)
- ESR (1)
- Embrittlement (1)
- Endocrine disruptor (1)
- Endokrine Disruptoren (1)
- Fe nanoparticles metabolism (1)
- Fenton (1)
- Ferritic steels (1)
- Fluorescence (1)
- Fragmentation activation (1)
- Fungicide (1)
- GDMS (1)
- Geological thermometer (1)
- Germanium sulfide (1)
- HPLC-ICP-MS (1)
- HR-CS-AAS (1)
- HRMS (1)
- Heavy crude oil (1)
- High repetition rate (1)
- High-resolution absorption isotopic spectrometry (1)
- High-resolution continuum source atomic absorption spectrometer (1)
- High-resolution continuum source graphite furnace atomic absorption spectrometry (1)
- Hormone (1)
- Human serum (1)
- Hydrodynamic chromatography (HDC) (1)
- IDMS (1)
- In situ (1)
- In vitro (1)
- Industry 4.0 (1)
- Ionmobility spectrometry (1)
- Iposomes (1)
- Iron nanoparticles (1)
- Katalysator (1)
- LA-ICP-MS (1)
- Laser Desorption (1)
- Laser-Induced Plasma (1)
- Laser-spark ionization (1)
- MS-ICP-MS (1)
- Magnetic nanocatalyst (1)
- Magnetpartikel (1)
- Matrix (1)
- Matrixeffekte (1)
- Metals (1)
- Microemulsion (1)
- Microfluidic (1)
- Microfluidics (1)
- Molecular spectrum (1)
- Mukuru (1)
- Multivariate analysis (1)
- Nano-carrier (1)
- Nanon (1)
- Nanoparticle (1)
- Nanoparticle characterization (1)
- Nanoparticles (1)
- Oberflächenwasser (1)
- Online NMR spectroscopy (1)
- Optical emission spectroscopy (1)
- Oxidative metabolism (1)
- Peptide library (1)
- Pesticide (1)
- Plasma (1)
- Polymerwissenschaften (1)
- Process analytical technology (1)
- Process industry (1)
- Public funding (1)
- Purity (1)
- Quality assurance (1)
- Quantification (1)
- Quantum state (1)
- Reaction dynamics (1)
- Reference (1)
- Reference material (1)
- Reference materials (1)
- SEM (1)
- SI (1)
- Single particle ICP-MS (1)
- Singulettsauerstoff (1)
- Sonochemical synthesis (1)
- SpICP-MS (1)
- Species-unspecific on-line isotope dilution (1)
- Spectrochemical analysis (1)
- Spectrometer (1)
- Spectrometry (1)
- Strain rates (1)
- Sugars (1)
- Surface chemistry (1)
- Sustainability (1)
- TEM (1)
- Tandem MS (1)
- Thermal-desorption spectroscopy (1)
- Titanium (1)
- Transformation products (1)
- Ultrasonic Levitation (1)
- Ultrasonic acoustic resonator (1)
- Urban planning (1)
- Vacuum ultraviolet (VUV) light (1)
- Validation (1)
- Wastewater (1)
- Water (1)
- Xerogel (1)
- Zirconium (1)
- ion optics (1)
Organisationseinheit der BAM
- P Präsident (56)
- 1 Analytische Chemie; Referenzmaterialien (49)
- P.0 Präsident und andere (43)
- 1.1 Anorganische Spurenanalytik (20)
- 1.3 Instrumentelle Analytik (18)
- 1.6 Anorganische Referenzmaterialien (15)
- PST Präsidiale Stabsstelle (15)
- 1.9 Chemische und optische Sensorik (12)
- 6 Materialchemie (11)
- 6.3 Strukturanalytik (7)
Society for Applied Spectroscopy (SAS) Atomic Section Student Award.
Magnesium is a major element in the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg. It is due to their relatively large mass difference (~8% between) that isotope fractionation leads to slight variations of isotope amount ratios in biological, environmental and geological samples. Traditionally, isotope ratios are measured by mass spectrometric methods. Their drawbacks include the high costs for instruments and their operation, experienced operators and elaborate time-consuming chromatographic sample preparation.
Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS), and laser ablation molecular isotopic spectrometry (LAMIS).
For the determination of Mg isotope ratios in selected rock reference materials, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied and their results compared with MC-ICP-MS. By HR-CS-MAS, samples were dissolved by acid digestion and Mg isotopes analyzed with and without matrix. The absorption spectrum was recorded for MgF for the electronic transitions X 2Σ → A 2 Πi, and X 2Σ → B 2Σ+. In the case of LAMIS, we investigated the MgF molecule for the electronic transition A 2Πi → X 2Σ, as well as direct analysis by the MgO molecule for the electronic transition A 1Π+ → X 1Σ. The MgF and MgO spectra are described as the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO. The isotope analysis was done by deconvolution of the MgF spectrum by partial least square regression (PLS) calibrated with enriched isotope spikes. Results were accurate with precisions ranging between 0.2 ‰ and 0.8 ‰ (2 SD, n= 10) for HR-CS-GFMAS. No statistically significant differences were observed for samples w/o matrix extraction. On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of direct analysis, however the precision is lower due the lack of solid isotopic calibration standards.
Magnesium is a major element in the hydrosphere and biosphere and plays important roles in (bio-) geochemical and physiological cycles. Mg has three stable isotopes, 24Mg, 25Mg and 26Mg. It is due to their relatively large mass difference (~8% between) that isotope fractionation leads to slight variations of isotope amount ratios in biological, environmental and geological samples. Traditionally, isotope amount ratios are measured by mass spectrometric methods. Their drawbacks include the high costs for instruments and their operation, experienced operators and elaborate time-consuming chromatographic sample preparation. Recently, an optical spectrometric method has been proposed as faster and low-cost alternative for the analysis of isotope ratios: high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS).
For the determination of Mg isotope ratios in selected rock reference materials, the high-resolution molecular absorption spectrum of in-situ generated MgF molecule was studied applying multivariate analysis and the results compared with MC-ICP-MS. Samples were dissolved by acid digestion and Mg isotopes analyzed with and without matrix. The absorption spectra were recorded for MgF for the electronic transition X 2Σ → B 2Σ+. The MgF spectrum is described as the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF. The isotope analysis was done by deconvolution of the MgF spectrum by partial least square regression (PLS). A PLS model was built and calibrated with enriched isotope spikes and certified reference materials. Spectra data was preprocessed by a derivate of second order and venetian blinds cross-validation was employed for finding the optimum latent variables. Finally, the model was refined by a genetic algorithm which identified the best subset of variables for a precise and accurate regression. Results are compatible with those obtained by MC-ICP-MS with an accuracy of ± 0.3‰ with uncertainties ranging between 0.02 to 0.6‰.
Magnesium is a naturally occurring element that can be found in several mineral forms in the earth crust. This element presents three stable isotopes 24Mg, 25Mg and 26Mg with a natural abundance of 79%, 10%, and 11% respectively. It is due to their relatively large mass difference (~8% between 24Mg and 26Mg) that isotope fractionation leads to slight isotope amount ratio variations n(26Mg)/n(24Mg) in biological and geological samples. Traditionally, isotope amount ratios have been measured by mass spectrometric methods. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time-consuming. Recently, optical spectrometric methods have been proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) and laser ablation molecular isotopic spectrometry (LAMIS). For the determination of Mg isotope amount ratios, the molecular spectrum of the in-situ generated MgF and MgO molecules were studied. In the case of HR-CS-GFMAS, the absorption spectrum was recorded for MgF for the electronic transitions X 2Σ → A 2 Πi and X 2Σ → B 2Σ+ around wavelengths 358 nm and 268 nm respectively. In the case of LAMIS, it was studied the MgF molecule for the electronic transitions A 2Πi → X 2Σ as well as the MgO molecule for the electronic transition A 1Π+ → X 1Σ around 500 nm. The MgF and MgO spectra are composed by the linear combination of their isotopic components or isotopologues: 24MgF, 25MgF, and 26MgF for the MgF and 24MgO, 25MgO, and 26MgO for the MgO (F is monoisotopic, and the isotope composition of O is assumed as constant). By HR-CS-GFMAS the analysis of Mg was done by deconvolution of the MgF spectrum by a partial least square regression (PLS) calibrated with enriched isotope spikes. The isotope amount ratios in rock samples with and without matrix separation were analyzed. Resulting delta values were obtained with precisions ranging between 0.2-0.5 ‰. On the other hand, LAMIS allows the direct analysis of solid samples with the extended possibility of in-situ analysis. Main advantages, limitations, and scopes of both optical techniques are going to be discussed and compared with MC-ICP-MS.
Mass spectrometric Methods MC-ICP-MS and TIMS) are without doubt the working horse of stable isotope analysis. However, drawbacks of these methods include the high costs for instruments and their operation, experienced operators and elaborate chromatographic sample preparation which are time consuming.
Optical spectrometric methods are proposed as faster and low-cost alternative for the analysis of isotope ratios of selected elements by means of high-resolution continuum source molecular absorption spectrometry (HR-CS-MAS) and laser ablation molecular isotopic spectrometry (LAMIS). First, stable isotope amount compositions of boron (B) and magnesium (Mg) were determined based on the absorption spectra of in-situ generated heteronuclear diatomic molecules (MH or MX) in graphite furnace HR-CS-MAS. The use of a modular simultaneous echelle spectrograph (MOSES) helps to find the maximal isotope shift in the diatomic molecular spectra produced in a graphite furnace by using isotopic spike solutions. Isotopes of boron (10B and 11B) were studied via their hydrides for the electronic transition X 1Σ+ → A 1Π. The spectrum of a given sample is a linear combination of the 10BH molecule and its isotopologue 11BH. Therefore, the isotopic composition of samples can be calculated by a partial least square regression (PLS). For this, a spectral library was built by using samples and spikes with known isotope composition. Boron isotope ratios measured by HR-CS-MAS are identical with those measured by mass spectrometric methods at the 0.15 ‰ level. Similar results were obtained for a multiple isotope system like Mg (24Mg, 25Mg, and 26Mg), where isotope shifts of their isotopologues can be resolved in the MgF molecule for the electronic transition X 2Σ → A 2 Πi. Finally, the application of molecular spectrometry via emission by LAMIS is compared and discussed.
Arraying of single cells for mass spectrometric analysis is a considerable bioanalytical challenge. In this study, we employ a novel single cell arraying technology for quantitative analysis and isotopic fingerprinting by laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOF-MS). The single cell arraying approach is based on a piezo-acoustic microarrayer with software for automated optical detection of cells within the piezo dispense capillary (PDC) prior to arraying. Using optimized parameters, single cell occupancy of >99%, high throughput (up to 550 cells per hour), and a high cell recovery of >66% is achieved. LA-ICP-TOF-MS is employed to detect naturally occurring isotopes in the whole mass range as fingerprints of individual cells. Moreover, precise quantitative determination of metal-containing cell dyes is possible down to contents of ∼100 ag using calibration standards which were produced using the same arrayer.
Tandem mass spectrometry represents an important analytical tool to unravel molecular structures and to study the gas-phase behavior of organic molecules. Besides commonly used methods like collision-induced dissociation and electron capture or transfer dissociation, new ultraviolet light–based techniques have the potential to synergistically add to the activation methods. Here, we present a new simple, yet robust, experimental design for polychromatic activation of trapped ions using the 115–160 nm output of a commercially available deuterium lamp. The resulting continuous dissociative excitation with photons of a wide energy range from 7.7 to 10.8 eV is studied for a comprehensive set of analyte classes in both positive and negative ion modes. While being simple, affordable, compact, and of low maintenance, the new setup initiates fragmentation of most precursor ions via their known dissociation pathways. Additionally, some new fragmentation patterns were discovered. Especially, electron loss and electron capture reactions with subsequent fragmentations were observed. For oligonucleotides, peptides, carbohydrates, and organic dyes, in comparison to collision-induced dissociation, a significantly wider fragment distribution was obtained, resulting in an information increase. Since the individual photons carry enough energy to post-ionize the nascent fragments, a permanent vacuum ultraviolet light exposure inside the ion trap potentially goes along with a general increase in detection capability.
A fast and simple method for sulfur quantification in crude oils was developed by using high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS). For this, heavy crude oil samples were prepared as microemulsion (shake) and injected into a graphite furnace (shut). Finally, the concentration of sulfur was determined by monitoring in situ the transient molecular spectrum of GeS at wavelength 295.205nm after adding a germanium solution as molecular forming agent (and go). Zirconium dioxide in the form of nanoparticles (45–55nm) was employed as a permanent modifier of the graphite furnace. Calibration was done with an aqueous solution standard of ammonium sulfate, and a characteristic mass (m0) of 7.5ng was achieved. The effectiveness of the proposed method was evaluated analizing, ten heavy crude oil samples with Sulfur amounts ranging between 0.3 and 4.5% as well as two NIST standard reference materials, 1620c and 1622e. Results were compared with those obtained by routine ICP-OES analysis, and no statistical relevant differences were found.
Advances in laser-induced plasmas have enabled various rapid and simple analytical applications. Especially, their uses in the analyses of condensed-phase samples have drawn significant attention in the past few decades. Depending on the laser energy per pulse, various analytical goals can be achieved. Laser-induced airborne plasmas allow direct analysis of species in ambient air. Importantly,
all of these applications are based on a fundamental understanding of the laser–medium interaction. Recent developments of diode-pumped solid-state lasers offer an alternative to conventional powerful, yet bulky lasers, which can specifically operate at high Repetition rates. Although these lasers deliver much lower power per pulse (mJ compared to mJ), the outstanding repetition rates offer significant improvement to meet statistical needs in some cases. In the present work, a mJ-laserinduced airborne plasma was characterized through optical emission analysis. By using a ns-timegated image detector coupled with specific bandpass filters, spatially, temporally, and spectrally resolved plasma images were recorded. Compared to conventional mJ-laser-induced plasmas, the one induced by mJ-lasers demonstrated unique features during its evolution. Specifically,
measurements of the distribution of ionic and atomic species revealed distinctive energy/matter transfer processes during early ignition of the plasma. Meanwhile, dynamic investigations suggested subsequent matter transport in the later stage.
Sustainability means meeting the needs of today without compromising the needs of the next generations. How can we meet the needs of the next generations, if we do not even know what these needs are? If we do not listen to the next generation and learn from them? Do we even meet the needs of today for everyone on earth?