Anmelden

Open Access

  • Startseite
  • Suchen
  • Browsen
  • Veröffentlichen
  • Hilfe
  • Organisationseinheit der BAM

P Präsidium

  • P.0 Präsident und Vizepräsident (209) RSS-Feed abonnieren
  • PST Präsidiale Stabsstelle (41) RSS-Feed abonnieren
  • UK Unternehmenskommunikation RSS-Feed abonnieren

Filtern

Autor

  • Jakubowski, Norbert (6) (entfernen)

Erscheinungsjahr

  • 2015 (6) (entfernen)

Dokumenttyp

  • Zeitschriftenartikel (3)
  • Vortrag (3)

Sprache

  • Deutsch (3)
  • Englisch (3)

Referierte Publikation

  • nein (3)
  • ja (3)

Schlagworte

  • Asymmetric flow filed-flow fractionation (1)
  • Berlin tap water (1)
  • Gadolinium-based contrast agents (1)
  • Hydrophilic interaction chromatography (HILIC) (1)
  • ICP-MS (1)
  • Inductively coupled plasma mass spectrometry (ICP-MS) (1)
  • Internal standard (1)
  • Nanoparticles (1)
  • Quantification (1)
  • Sample loss (1)
+ weitere

Organisationseinheit der BAM

  • 1 Analytische Chemie; Referenzmaterialien (6)
  • 1.1 Anorganische Spurenanalytik (6)
  • P Präsidium (6)
  • P.0 Präsident und Vizepräsident (6)
  • 1.3 Strukturanalytik (1)
  • 6 Materialschutz und Oberflächentechnik (1)
  • 6.1 Oberflächenanalytik und Grenzflächenchemie (1)

6 Treffer

  • 1 bis 6
  • CSV
  • RIS
  • 10
  • 20
  • 50
  • 100

Sortieren nach

  • Jahr
  • Jahr
  • Titel
  • Titel
  • Autor
  • Autor
Determination and Speciation of Lanthanoides by ICP-MS (2015)
Jakubowski, Norbert
Sample loss in asymmetric flow field-flow fractionation coupled to inductively coupled plasma-mass spectrometry of silver nanoparticles (2015)
Sötebier, Carina ; Bierkandt, Frank ; Rades, Steffi ; Jakubowski, Norbert ; Panne, Ulrich ; Weidner, Steffen
In this work, sample losses of silver nanoparticles (Ag NPs) in asymmetrical flow field-flow fractionation (AF4) have been systematically investigated with the main focus on instrumental conditions like focusing and cross-flow parameters as well as sample concentration and buffer composition. Special attention was drawn to the AF4 membrane. For monitoring possible silver depositions on the membrane, imaging laser ablation coupled to inductively coupled plasma mass spectrometry (LA-ICP-MS) was used. Our results show that the sample residue on the membrane was below 0.6% of the total injected amount and therefore could be almost completely avoided at low sample concentrations and optimized conditions. By investigation of the AF4 flows using inductively coupled plasma mass spectrometry (ICP-MS), we found the recovery rate in the detector flow under optimized conditions to be nearly 90%, while the cross-flow, slot-outlet flow and purge flow showed negligible amounts of under 0.5%. The analysis of an aqueous ionic Ag standard solution resulted in recovery rates of over 6% and the ionic Ag content in the sample was found to be nearly 8%. Therefore, we were able to indicate the ionic Ag content as the most important source of sample loss in this study.
Laser Ablation ICP-MS: A new tool for Bio-Imaging (2015)
Jakubowski, Norbert
Analysis of Gadolinium-based contrast agents in tap water with a new hydrophilic interaction chromatography (ZIC-cHILIC) hyphenated with inductively coupled plasma mass spectrometry (2015)
Lindner, Uwe ; Lingott, Jana ; Richter, Silke ; Jiang, W. ; Jakubowski, Norbert ; Panne, Ulrich
Hydrophilic interaction chromatography (HILIC) coupled with inductively coupled plasma mass spectrometry (ICP-MS) were optimised for the direct determination of gadolinium-based contrast agents in tap water. In comparison to our previous work, a new developed zwitterionic HILIC column (ZIC-cHILIC) was used for speciation of Gd-containing contrast agents. The limit of quantification (LOQ) for the five contrast agents Gd-BOPTA, Gd-DPTA-BMA, Gd-BT-DO3A, Gd-DOTA and Gd-DTPA are in the range of 5–12 ng Gd per litre. Additionally, a new internal standard, Pr-DOTA, was investigated to correct intensity drifts, minor and major changes in the sample volumes and possible matrix effects. With the speciation method described, tap water samples from the area of Berlin were analysed and for the first time, three Gd species, Gd-BT-DO3A, Gd-DOTA and Gd-BOPTA, were found in tap water samples at concentrations of about 10–20 ng Gd per litre. These are the same Gd species which have been previously detected predominantly in surface waters of the Berlin area.
Speciation and imaging of Gd containing MRI contrast agents in environmental samples by ICP-MS (2015)
Jakubowski, Norbert
Direct multi-elementanalysis of plastic materials via solid sampling electrothermal vaporization inductively coupled plasma optical emission spectroscopy (2015)
Börno, Fabian ; Richter, Silke ; Deiting, D. ; Jakubowski, Norbert ; Panne, Ulrich
In this work the determination of Cd, Cu, Cr, Fe and Sb as organic and inorganic additives in in-house plastic materials (ABS, LDPE) using electrothermal vaporization combined with inductively coupled plasma optical emission spectroscopy is described. The influence of CCl2F2 as gaseous halogenation modifier was investigated. Especially for the carbide forming elements the sensitivity was improved and the memory effects were significantly reduced. Calibration was performed by external calibration and standard addition with aqueous standard solutions added directly into the sample boats. Absolute limits of detection (3s-criterion) range between 0.1 ng (Cd) and 9 ng (Fe) which corresponds to relative values of 0.1 mg kg-1 and 1.6 mg kg-1, respectively, taking 5 mg as typical sample mass. The detection limits are sufficient to monitor the element contents of plastic materials according to European directives such as European directive on the safety of toys. The developed ETV-ICP-OES method allows a fast analysis with a high sample throughput (3 minutes per analysis), low sample consumption and good trueness and precision for the analyzed elements. Sample preparation is reduced to ashing the samples in a muffle furnace. Furthermore, measurements are possible regardless of the chemical form in the additives. For verification the results obtained with the developed method were compared with measurement results of independent methods ICP-MS/OES after digestion. In addition Cd, Cr and Pb were determined in a solid plastic reference material BAM-H010 to confirm the applicability and accuracy of the method.
  • 1 bis 6

OPUS4 Logo

  • Kontakt
  • Impressum
  • Sitelinks