Advances and Applications of Molecular Absorption Spectrometry: from Non-Metals to Isotope Analysis
(2019)
The present work covers two main aspects of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS), an analytical technique for elemental trace analysis.
First, a comprehensive mechanistic study of molecule formation in graphite furnaces is presented, which is a key step into the recovery of analytical signals. For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in HR-CS-GFMAS. A zirconium coating catalyzes the CaF formation, and its structure was investigated. The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. Here a mechanism is proposed, where ZrO2 works as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface.
Second, analytical methods were developed by using HR-CS-MAS as detector for non-metals and isotope analysis. Therefore, the determination of organic absorbable chlorine in water, the quantification of fluorine in consume care products with declared perfluorinated ingredients, and the determination of sulfur content in crude oils were investigated. Finally, the high resolution of the instrumentation allows to measure isotopic shifts with high precision in some observed molecular spectra. Consequently, the molecular spectra of enriched isotopes of boron and magnesium were investigated, establishing so the potential of HR-CS-MAS for the accurate and precise determination of isotopic amount ratios.
Zusammenfassung
Die vorliegende Arbeit befasst sich mit zwei zentralen Aspekten der High-Resolution-Continuum-Source-Molekülabsorptionsspektrometrie mit Graphitrohrtechnik (HR-CS-GFMAS), einer Analysetechnik für elementare Spurenanalyse.
Der erste Teil der Arbeit umfasst eine mechanistische Studie zur Molekülbildung auf Graphitoberflächen. Dies ist ein wichtiger Schritt, um analytische Signale zu entdecken. Dazu wurde die Molekülbildung von CaF analysiert, welches für die indirekte, analytische Bestimmung von Fluor in HR-CS-GFMAS genutzt wird. Die CaF Bildung wurde mittels einer Beschichtung aus Zirconium katalysiert und deren Struktur analysiert. Die Kinetik dieser Reaktion wurde durch Beobachtung des jeweiligen Molekülspektrums bei verschiedenen Atomisierungstemperaturen beobachtet. Ein Arrheniusplot zeigte für Fluor (n = 1) eine Reaktion Pseudo-erster Ordnung. Ein Übergangszustand wurde über die mit Zirconium überzogene Grafitoberfläche isoliert und seine Struktur mittels spektroskopischer Methoden Energiedispersive Rasterelektronenmikroskopie / Röntgenspektroskopie (REM-EDX), Röntgenphoto¬elektronenspektroskopie (XPS), Röntgenabsorptionsspektroskopie (XAS) und Raman Spektroskopie untersucht. Auf Grundlage dieser Ergebnisse wird ein Mechanismus vorgeschlagen, bei dem ZrO2 als heterogener Katalysator fungiert; in Folge einer Pyrolysestufe wird ein Übergangszustand des ZrO(OCaF) aktiviert, welcher bei höheren Temperaturen CaF(g) an der Zirconium-Graphitoberfläche freisetzt.
Im zweiten Teil der Arbeit werden Analysemethoden entwickelt, in dem HR-CS-MAS als Detektor für Nichtmetalle und Isotopanalyse angewandt wird. Hierfür wurde organisch gebundenes Chlor im Wasser bestimmt, der Fluorgehalt in Pflegeprodukten mit perfluorierten Inhaltsstoffen quantifiziert und der Schwefelgehalt in Erdöl untersucht. Weiterhin ermöglicht die hohe Auflösung der Messgeräte eine präzise Bestimmung der Isotopenverschiebung einiger untersuchter Molekülspektren. Daher wurden die Molekülspektren angereicherter Bor- und Magnesiumisotope untersucht. Auf diese Weise wurde das Potential von HR-CS-MAS für die akkurate und präzise Bestimmung von Isotop-Mengenverhältnissen nachgewiesen.
Die matrixunterstützte Laser Desorptions/Ionisations Massenspektrometrie (MALDI-MS) hat sich in den letzten Jahren zu einer etablierten Methode zur Charakterisierung von synthetischen Polymeren entwickelt. Neben der Messung von Molmassen und deren Verteilungen bietet diese Technik die Möglichkeit, simultan Monomerstrukturen und Endgruppen eines Polymers zu bestimmen.
Ein weiterer wesentlicher Vorteil liegt in der einfachen Probenpräparation, die überwiegend durch Auftropfen der Matrix- und Polymerlösung (engl. Dried Droplet Method) erfolgt. Anstelle eines homogenen Probenspots wird nach dem Verdampfen des Lösemittels häufig jedoch die Bildung von Eintrocknungsringen beobachtet. Dies führt zu lokal unterschiedlichen Matrix/Polymer Verhältnissen, was die Qualität und Reproduzierbarkeit der MALDI Methode erheblich beeinträchtigt. Dies ist insbesondere von Interesse, da synthetische Polymere, im Gegensatz zu biologischen Makromolekülen, eine Kettenlängen-Verteilung aufweisen, die ebenfalls Segregationseffekten unterliegen kann. Eine realistische Bestimmung von Molmassen und deren Verteilung ist demzufolge nahezu unmöglich. Auf Grund der weiten Verbreitung der Dried Droplet Methode ist es daher erforderlich, mögliche Ursachen der Segregation aufzuklären und gegebenenfalls alternative Probenpräparationstechniken, basierend auf dieser simplen Tropfenmethode zu entwickeln. Zu diesem Zweck wurde die Trocknung verschiedener Polymer/Matrix Spots bei Verwendung unterschiedlicher Lösemittel untersucht. Da die MALDI Methode auch die Möglichkeit bietet, als bildgebendes Verfahren (MALDI-Imaging Massenspektrometrie) genutzt zu werden, wurde diese Technik primär für die Untersuchung der Segregationseffekte verwendet. In Analogie zum Einsatz in biologischen Systemen, beispielsweise bei der Lokalisierung von Metaboliten oder Wirkstoffen in Gewebeproben, kann mittels MALDI-Imaging MS die laterale Verteilung von Polymeren mit unterschiedlichen Strukturen und Molmassen sowie der Matrix simultan bestimmt werden.
Im Gegensatz zu den in der Literatur beschriebenen Prozessen, wie Kapillarfluss oder Marangoni Strömung, die u.a. für die Ringbildung verantwortlich gemacht wurden, zeigen die Ergebnisse der hier vorgestellten Experimente deutlich, dass die Löslichkeit von Polymer und Matrix im verwendeten Lösemittel von entscheidender Bedeutung ist. Im Verlauf des Verdampfungsprozesses findet eine Aufkonzentrierung der Moleküle im abgesetzten Tropfen statt. Beim Erreichen der Sättigungskonzentration beginnen die Polymermoleküle mit den hohen Molmassen zuerst auszufallen, während die restlichen, immer noch gelösten Homologen weiterhin den Transportvorgängen unterliegen, die beim Eintrocknen generiert werden. Bei Lösemitteln die langsam verdunsten kann das zur molmassenabhängigen Segregation von Polymerhomologen führen. Verwendet man Lösemittel die schnell verdunsten erfolgt keine Molmassen-Segregation der Polymere, sondern ausschließlich eine Entmischung von Matrix und Polymer. Auf Grund ihrer geringen Molmasse bleibt die Matrix am längsten gelöst und kann demzufolge bis unmittelbar vor dem Eintrocknen an den Tropfenrand transportiert werden. Dies erklärt die Bildung von hauptsächlich aus Matrix bestehenden Ringen bei der üblicherweise verwendeten Konzentration von 10 mg ml-1. Die Experimente haben jedoch auch gezeigt, dass die beobachtete Entmischung bei einer deutlich höheren Konzentration von 100 mg ml-1 ohne Einschränkungen in der Qualität der Spektren vermieden werden kann. Bei dieser Konzentration wird die Sättigungskonzentration der Matrix bereits vor dem ersten Ausfallen der Polymere erreicht. Dadurch entsteht eine hoch viskose Lösung, welche die folgenden Transportprozesse der Polymermoleküle behindert. Eine Entmischung kann somit nicht mehr erfolgen und man erhält eine chemisch homogene Spotoberfläche.
Eine andere einfache Möglichkeit die Viskosität der Probenspots soweit zu erhöhen, dass keine Segregation erfolgen kann, bietet die Verwendung von Matrizes basierend auf ionischen Flüssigkeiten. Neben der einfachen Synthese zeichnen sich diese Verbindungen durch ihre hohe Stabilität und der Vermeidung einer Sublimation im Vakuum aus. Selbst nach 24h im Hochvakuum der MALDI-Quelle konnten reproduzierbare Spektren gemessen werden. Die Intensität der Spektren ist dabei deutlich höher als bei der Verwendung konventioneller Matrizes. Dies ermöglicht die Aufnahme von Spektren bei geringerer Bestrahlungsstärke, was wiederum zu weniger Fragmentierungen führt und insbesondere für labile Polymere interessant sein könnte. Die mit der Dried Droplet Methode und ionischen Matrizes erzeugten Spots weisen eine überragende Homogenität auf. Diese Matrixklasse stellt somit eine neue und interessante Alternative zur konventionellen Spotpräparation in der MALDI-TOF Massenspektrometrie dar.
Inductively coupled plasma mass spectrometry (ICP-MS) has been applied for the analysis of biomolecules due to its high sensitivity, wide linear dynamic range, and multielement capabilities. However, outside the elemental MS community the potential of this technique, e.g. for life sciences applications, is not yet fully exploited. Thus, the development of ICP-MS-based (immuno) assays for a wide range of medical (cancer diagnostics, cisplatin toxicity studies), biochemical (DNA microarray, single cell analysis), and environmental (analysis of comestible goods) applications was accomplished by utilization of chemical labels. Laser ablation (LA)-ICP-MS was employed for the direct analysis of solid samples like microarrays and thin tissue sections. An immunoassay was developed for ochratoxin A (OTA) determination in wine, and ICP-MS detection was compared to conventional photometry by gold nanoparticle tagging and horseradish peroxidase, respectively. Detection limits of the assay were optimized to 0.003 μg L-1, and the quantification range was 0.01–1 μg L-1 for both methods. For LA-ICP-MS-based DNA microarray detection, gold nanoparticle tags were specifically introduced via a streptavidin-biotin linkage. In immunohistochemistry (IHC), up to 20 tumor markers are routinely evaluated for one patient and thus, a common analysis results in a series of time consuming staining procedures. Hence, LA-ICP- MS was elaborated as a detection tool for a novel, multiplexed IHC analysis of tissue sections. Different lanthanides were employed for the simultaneous detection of up to three tumor markers (Her 2, CK 7, and MUC 1) in a breast cancer tissue. Additionally, iodine was employed as a labeling reagent, and a new LA-ICP-MS method for single cell and cell nucleus imaging was developed at 4 μm laser spot size. Iodine was also applied as a new internal standard for tissue samples. Moreover, Pt-protein complexes separated by an optimized 1D and 2D gel electrophoresis were analyzed by LA-ICP-MS. The high spatial resolution of this technique was further demonstrated in a current study of cisplatin toxicity and renal protective strategies in rat kidney tissue by detecting platinated proteins.
Seit einem Jahrzehnt sind Röntgenquellen für die Mikrofokus-Röntgenfluoreszenzanalyse (μ-RFA) kommerziell erhältlich und bieten die Möglichkeit, die Analytik am Rasterelektronenmikroskop (REM) mit angeschlossenem energiedispersiven Röntgenspektrometer (EDS) zu erweitern. Mit der μ-RFA lässt sich quantitativ, referenzfrei und zerstörungsfrei der Gehalt der chemischen Elemente in einem mikroskopischen Probenvolumen bestimmen. Für die referenzfreie Quantifizierung mit der RFA wird auf die Sherman-Gleichung zurückgegriffen. Diese Gleichung führt die Intensität der detektierten Röntgenstrahlung auf den Gehalt des Elements in der Probe mittels Fundamentalparameter zurück. Zu den instrumentellen Fundamentalparametern zählen das Anregungsspektrum bestehend aus dem Röntgenröhrenspektrum und der Transmission der Röntgenoptik, die Messgeometrie und die Spektrometereffizienz. Das Ziel dieser Arbeit ist die Entwicklung von Prozeduren zur Charakterisierung der instrumentellen Fundamentalparameter der μ-RFA am REM sowie die Evaluierung und Verringerung der Messunsicherheiten anhand einer kalibrierten Instrumentierung: Die aus der Literatur bekannten Algorithmen zur Berechnung von Röntgenröhrenspektren sollen hinsichtlich ihrer Abweichungen evaluiert werden. Ein semi-empirischer Ansatz wird innerhalb dieser Arbeit bezüglich seiner Unsicherheiten und im niederenergetischen Bereich verbessert. Für drei weitere Anodenmaterialien soll dieser Ansatz erweitert werden. Die mit diesem Ansatz berechneten Röntgenröhrenspektren werden mit direkt gemessenen Röntgenröhrenspektren verglichen, die an einem speziell entwickelten Messstand eines Röntgenröhrenherstellers aufgenommen wurden. Eine Prozedur zur Bestimmung der wichtigsten Parameter von Röntgenhalblinsen im parallelisierenden Modus wird entwickelt. Die zeitliche Stabilität der Transmission von Röntgenvolllinsen, die seit mehreren Jahren im regelmäßigen Einsatz an einer μ-RFA-Quelle waren, wird untersucht. Für das Labor wird ein Verfahren zur Bestimmung der Spektrometereffizienz bis 50 keV neu entwickelt. Neben dieser methodischen Weiterentwicklung werden Anwendungen für die neu charakterisierten instrumentellen Fundamentalparameter vorgestellt. Darunter soll die referenzfreie Quantifizierung mit der μ-RFA am REM anhand von repräsentativen Probenklassen hinsichtlich ihrer Stärken und Schwächen vorgestellt werden. Die Nachweisgrenzen der μ-RFA am REM für schwere Spurenelemente in leichten Matrizen werden an Proben zur Überprüfung einer EU-Richtlinie bestimmt. Darüber hinaus soll überprüft werden, ob die Berücksichtigung der Streueigenschaften einer Probe von Röntgenphotonen für die Analytik ausgenutzt werden kann.
Die vorliegende Arbeit beschäftigt sich mit der systematischen Untersuchung von gas- und aerosolförmigen Reaktionsprodukten beim Abbrand von pyrotechnischen Gegenstanden für den Indoor-Bereich. Dazu wurden alle Parameter der in meiner Diplomarbeit eigens dafür konstruierten Messkammer optimiert und eine Vielzahl an pyrotechnischen Gegenständen vermessen. Die Resultate wurden mit Messungen unter realen Bedingungen verglichen. Zur besseren Beurteilung wurden zusätzlich Emissionsmessungen bei fünf verschiedenen Feuerwerksshows, sowohl Indoor als auch Outdoor, durchgeführt. Als Hauptergebnis konnte festgestellt werden, dass die gas- und aerosolförmigen Reaktionsprodukte unabhängig von dem pyrotechnischen Gegenstand online und mit einer guten Zeitauflösung in der Messkammer detektierbar sind. Eine Korrelation der Resultate zu den Messungen unter realen Bedingungen konnte hergestellt werden. Des Weiteren wurde nachgewiesen, dass der Effekt der als raucharm deklarierten pyrotechnischen Gegenstände nicht durch geringere Anzahlkonzentrationen, sondern durch geringere Durchmesser der entstehenden Aerosole erzielt wurde. Resultierend daraus waren mehr Partikel alveolengängig.
Entwicklung neuer Sonden für bioanalytische Anwendungen der oberflächenverstärkten Raman-Streuung
(2011)
Surface-enhanced Raman scattering (SERS) has been established as a versatile tool for probing and labeling in analytical applications, based on the vibrational spectra of samples as well as label molecules in the proximity of noble metal nanostructures. The aim of this work was the construction of novel SERS hybrid probes. The hybrid probes consisted of Au and Ag nanoparticles and reporter molecules, as well as a targeting unit. The concept for the SERS hybrid probe design was followed by experiments comprising characterization techniques such as UV/Vis- spectroscopy (UV/Vis), Transmission electron microscopy (TEM) and Dynamic Light Scattering (DLS), respectively. SERS experiments were per- formed for studying and optimizing the plasmonic properties of nanoparticles with respect to their enhancement capabilities. The SERS-probes had to meet following requirements: biocompatibility, stability in physiological media, and enhancement of Raman-signals from Raman reporter molecules enabling the identification of different probes even in a complex biological environment. Au and Ag nanoaggregates were found to be the most appropriate SERS substrates for the hybrid probe design. The utilization of Raman reporters enabled the identification of different SERS probes in multiplexing experiments. In particular, the multiplexing capability of ten various reporter molecules para-aminobenzenethiol, 2-naphthalenethiol, crystal violet, rhodamine (B) isothiocyanate, fiuorescein isothiocyanate, 5,5'dithiobis(2-nitrobenzoic acid), para- mercaptobenzoic acid, acridine orange, safranine O und nile blue was studied using NIR-SERS excitation. As demonstrated by the results the reporters could be identified through their specific Raman signature even in the case of high structural similarity. Chemical separation analysis of the reporter signatures was performed in a trivariate approach, enabling the discrimination through an automated calculation of specific band ratios. The trivariate identification could be a promising method for SERS-multiplexing in analytical applications. Multivariate methods such as Principal Components Analysis (PCA) and Hierarchical Cluster Analysis (HCA) were as well applied for discrimination and imaging of the reporter signatures. With the help of multivariate imaging methods based on cluster analysis, it could be for the first time demonstrated that such methods provided a fast identification of various SERS hybrid probes inside the biological matrix, this was demonstrated using living 3T3 cells. Further, in a duplex imaging approach, the probes fulfill the requirements for the sensitive detection of both the specific reporter signatures and intrinsic information coming from eukaryotic cells. The results of cluster methods and principal components approaches for discrimination indicate that fast, multivariate evaluation of whole sets of multiple probes is feasible, beyond the visual inspection of individual spectra that has been practiced so far. This suggests multiplexing applications with SERS hybrid nanoprobes and SERS tags in very high density sensing and biological imaging applications, where fast read-out is required. The pH-sensitivity of SERS-Tags that consisted of different reporter molecules attached to aggregated Au and Ag nanoparticles in the range between pH∼3-10 was studied. It could be demonstrated that the reporter molecules provided pH-dependent SERS signatures and could therefore be suitable for the sensitive pH-detection, e.g., inside cellular compartments. The construction of targeted SERS probes was based on the integration of a goat-anti- mouse antibody as targeting element Antibodies were coupled to Au and Ag nanoprobes surrounded by a Bovine Serum Albumin (BSA) coating which served as a carrier for the covalent linkage of a Raman reporter molecule and the targeting units at the same time In experiments with BSA and a conjugated reporter the spectra of the BSA-coupled re- porters provided an indication of the secondary structure of BSA which is related to the BSA-reporter coupling procedure In in v i t ro -experiments with BSA-coupled nanoprobes inside 3T3 cells reporter signatures and intrinsic information from the cellular matrix could be delivered BSA enabled the coupling of reporter molecules as well as the targeting of antibodies and served as stabilizer of the gold nanoaggregates The functionality of the coupled antibodies after their integration into the SERS probe was retained This was verified by the results of a direct Enzyme-Linked Immunosorbent Assay (ELISA) Conjugates with implemented reporter molecules could be characterized using SERS The application of the complete probes suggested a use of these novel biocompatible stable and targeted SERS probes that can be excited out-of- resonance also for other bioanalytical applications. On the basis of the constructed SERS hybrid probes comprising a large number of BSA- coupled reporters could e g be implemented for automated high-througput immuno- assays where they are arranged on a microstructured device for the simultaneous and multilevel SERS-readout in one step .
Mycotoxins are toxic secondary metabolites of ubiquitously occurring moulds. Through the consumption of contaminated foods, they can cause acute or chronic intoxications in humans. Here, it is demonstrated how covalent hydrazine chemistry can be used to improve the performance of instrumental methods for the quantification of trace level food mycotoxins. In the case of the Alternaria mycotoxin tenuazonic acid, pre-column derivatisation with 2,4-dinitrophenylhydrazine resolved chromatographic issues due to the chemical properties of the analyte and allowed for its rapid, sensitive and selective quantification in cereals and beer by high performance liquid chromatography- ion-trap two stage mass spectrometry (HPLC-IT-MS2). Tenuazonic acid could be detected for the first time in beer and buckwheat flour. Although the encountered levels were too low to cause acute intoxications, the frequency of contamination indicated possible health risks due to chronic exposure. In a second scenario, dynamic covalent hydrazine chemistry (DCHC) was exploited for a novel extraction and cleanup method applicable to the Fusarium mycotoxin zearalenone occurring in edible oils. Zearalenone was extracted by hydrazone formation on a hydrazinefunctionalised polymer resin and subsequently released hydrolytically for quantification by HPLC-fluorescence detection (HPLC- FLD). The high selectivity of the approach allowed for the omission of MS detection and immunoaffinity cleanup. The DCHC method was superior to previously published methods in terms of handling efforts, cost, precision and selectivity and is well suited for the monitoring of the current European maximum level for zearalenone in refined maize oil. In the second part of the dissertation, possible degradation routes of Alternaria mycotoxins upon storage and bread baking are discussed. In the frame of a kinetic study, it was shown that tenuazonic acid is degraded by two parallel processes, deacetylation and epimerisation, when stored in aqueous solution (half-life at 25 °C ~ 74 days). The primary degradation product deacetyl tenuazonic acid was less stable than its parent compound and degraded rapidly in beverage matrices. In model baking experiments it was furthermore revealed that alternariol, alternariol monomethyl ether and altenuene are stable under typical baking conditions. A newly identified degradation route, which is based on a sequence of hydrolysis and decarboxylation, caused only minor substance losses (< 1 %). Still, the degradation products could be detected in commercial rusk and crispbread by HPLC-tandem mass spectrometry (HPLC-MS/MS).
Diese Arbeit widmet sich der Analyse von Pollenkörnern und einzelnen Pollenkomponenten mit Hilfe der Raman-Spektroskopie, ergänzt wurden diese Untersuchungen durch den Einsatz der Massenspektrometrie, ESEM-Technik, Hochleistungs-Dünnschicht- Chromatographie, IR- und NMR-Spektroskopie. Die Klassifizierung der Pollenspezies erfolgte durch eine Clusteranalyse der Raman- Spektren. Diese Methode kann die Grundlage für eine automatische On-line-Detektion zur Erstellung von Pollenflugwarnungen für Allergiker bilden. Es gelang die Pollenarten zu unterscheiden, darüber hinaus spiegeln die resultierenden Dendrogramme den phylogenetischen Ursprung der Pollenspezies wider. Eine Ursache für falsche Zuordnungen der Pollen stellten hohe Gehalte an Carotinoiden dar. Durch das Bestrahlen der Proben mit 633 nm wurden die Carotinoide abgebaut und der Einfluss der Carotinoide auf die Clusteranalyse reduziert. Die Aufnahmen von resonanten Raman-Spektren der mittels HPTLC aufgetrennten Carotinoide belegten Unterschiede in der Zusammensetzung der Carotinoide in Abhängigkeit von der Pollenspezies. Die Konzentrationen der Carotinoide in den Pollen konnten mit Hilfe der UV-Vis Absorptions- Spektroskopie bestimmt werden. Des Weiteren konnte belegt werden, dass die in-situ Spektren ganzer Pollenkörner die typischen Carotinoidsignaturen einer Pollenspezies widergeben. Die in-situ Spektren sind von Vorteil, weil sie ohne Präparation aufgenommen wurden. Außerdem wurde der Einfluss der biologischen Matrix berücksichtigt. Weitere Bestandteile der Pollenkörner wurden isoliert und mit Hilfe der Raman-, IR- und NMR-Spek- troskopie untersucht. So konnten Veränderungen der chemischen Struktur durch die Aufreinigungsprozeduren nachgewiesen werden. Von besonderem Interesse ist die Analyse des Biomakromoleküls Sporopollen in, welches für die Langlebigkeit und chemischen Stabilität der Pollenkörner verantwortlich ist. Es wurden Aminosäuren, Phosphorlipide, Cellulose und Coumarinsäure in den Pollenkörnern gefunden. Die Verteilung dieser Substanzen in den Pollenkörnern konnte via 2D Raman-Experimente dargestellt werden. Die Signale der Coumarinsäure konnten ebenfalls in den Raman-Spektren keimender Pollenkörner entdeckt werden. Die Pollenschläuche bestehen überwiegend aus Cellulose. Neben diesen Gemeinsamkeiten wurden speziesspezifische Unterschiede der chemischen Zusammensetzung festgestellt.
Die vorliegende Arbeit befasst sich mit der Analyse hochreiner Metalle mittels GD-MS (Glimmentladungs-Massenspektrometrie). Der Schwerpunkt war dabei die Verbesserung der genauen Bestimmung von Elementspuren, insbesondere im μg kg-1-Bereich, für den Kalibrierproben bekannter Zusammensetzung praktisch nicht existieren. Zur Überwindung des Problems wurden flüssigdotiere Pulverpresslinge als synthetische Kalibrierproben für die Matrices Zn, In, Cu, Fe sowie Co und das System Co/C hergestellt. Durch umfassende Untersuchungen der Praparationsschritte und eine eingehende Charakterisierung der Presslinge konnte deren Herstellungsprozess optimiert und deren Verhalten in der Glimmentladung besser verstanden werden. Das erarbeitete Quantifizierungskonzept wurde durch die Messung zertifizierter Matrixreferenzmaterialien mit Gehalten im mg kg-1-Bereich validiert, und seine Eignung auf hohem metrologischen Niveau bei der sehr erfolgreichen Teilnahme an einem weltweiten Ringversuch der internationalen Metrologieinstitute nachgewiesen. Gegenüber den bislang mangels tragfähiger Alternative verwendeten kalibrierprobenfreien Quantifizierungskonzepten ist der Einsatz der Presslinge bezüglich Richtigkeit, Unsicherheit und Rückführung auf das internationale Einheitensystem deutlich überlegen. Die GD-MS mit ihren Vorteilen als schnelle direkte Feststoffmethode erreicht so erstmalig die Analysenqualität der etablierten losungsbasierten Analysenmethoden, und erhöht damit ihren Anwendungsbereich deutlich, so dass sie schließlich auch für die Analyse von realen Proben für wichtige metrologische Fragestellungen angewendet werden konnte, wie für die Analyse von Zn-Fixpunktzellen, die für die Definition der internationalen Temperaturskala ITS 90 benötigt werden, oder für Primarnormale der chemischen Analytik. Darüber hinaus wurde grundlegend die Übertragbarkeit der klassischen kalibrierprobenfreien Quantifizierungskonzepte auf das neu auf dem Markt befindliche hochauflösenden GD-MS Gerat (Element GD) untersucht. Dabei wurden insbesondere die Einschränkungen herausgearbeitet, die für das völlig anders konstruierte Vorgängermodell VG 9000 nicht gelten. Ergänzende Untersuchungen zum Hohlkathodeneffekt führten zwar nicht bei der GD-MS, wohl aber bei der GD OES (Glimmentladung mit optischer Emissionsspektrometrie), zu einer enormen Steigerung des Nachweisvermögens für Elementspuren.
Ihre Fähigkeiten schnell und ohne hohen Kostenaufwand jegliche Probenmatrices auf eine Vielzahl an Elementen analysieren zu können macht die laserinduzierte Plasmaspektroskopie besonders interessant für industrielle Anwendungen. Bisher jedoch weist die Methode Schwachstellen auf, die LIBS im Vergleich zu anderen Techniken unattraktiv erscheinen lässt. Es fehlt an kostengünstigen, einheitlichen, leicht bedienbaren Aufbauten. Die inhomogene Natur eines laserinduzierten Plasmas erschwert eine Elementanalyse mit LIBS. Für eine quantitative Analyse werden bisher am häufigsten Kalibrierungen über Linienintensitäten von bekannten Referenzmaterialien mit möglichst vergleichbarer Matrix unter selben Versuchsbedingungen durchgeführt. In dieser Arbeit wurden verschiedene Bereiche, die eine LIBS-Analyse beeinflussen, untersucht. Instrumentell bestimmt der Detektor neben dem wellenlängenseparierenden Element die Qualität der Auflösung einer Messung. Anhand des Vergleichs von zwei Detektoren, einer ICCD- und einer CCD-Kamera, konnte die Effizienz der CCD-Kamera gegenüber der ICCD experimentell bewiesen werden. Untersuchungen des Plasmaexpansionsverhaltens unter verschiedenen atmosphärischen Bedingungen konnten zeigen, dass die Detektionsgeometrie die Empfindlichkeit und Reproduzierbarkeit von Messungen beeinflusst. Bei der Konzentrationsermittlung unbekannter Elemente in einer Probe durch lineare Kalibriergeraden dürfen keine selbstabsorbierten Emissionslinien verwendet werden, die eine geringere Konzentration als tatsächlich vorhanden vortäuschen. Die Dupliaktionsmethode und die lineare Korrelationsanalyse wurden getestet solche Linien zu identifizieren. Verglichen zur Duplikationsmethode zeigte die lineare Korrelationsanalyse hohes Potenzial zur Charakterisierung des Beginns von Selbstabsorption einer Emissionslinie. Da oftmals die Referenzmaterialien zur Erstellung von Kalibriergeraden fehlen, wurden in dieser Arbeit individuelle Kalibrierstandards basierend auf einer Kupfer- und einer Polyacrylamidmatrix hergestellt und auf ihre Anwendbarkeit für LIBS getestet. Die Ergebnisse dieser Arbeit zeigen Optimierungsmöglichkeiten der Methode im instrumentellen sowie im applikativen Bereich.