Filtern
Dokumenttyp
- Dissertation (3)
Sprache
- Englisch (3) (entfernen)
Referierte Publikation
- nein (3) (entfernen)
Schlagworte
- Alternaria (1)
- Applied optical spectroscopy (1)
- Boron (1)
- Elemental Tags (1)
- Fluorine (1)
- Graphite furnace (1)
- HR-CS-MAS (1)
- ICP-MS (1)
- Isotope analysis (1)
- Life Sciences (1)
Organisationseinheit der BAM
Inductively coupled plasma mass spectrometry (ICP-MS) has been applied for the analysis of biomolecules due to its high sensitivity, wide linear dynamic range, and multielement capabilities. However, outside the elemental MS community the potential of this technique, e.g. for life sciences applications, is not yet fully exploited. Thus, the development of ICP-MS-based (immuno) assays for a wide range of medical (cancer diagnostics, cisplatin toxicity studies), biochemical (DNA microarray, single cell analysis), and environmental (analysis of comestible goods) applications was accomplished by utilization of chemical labels. Laser ablation (LA)-ICP-MS was employed for the direct analysis of solid samples like microarrays and thin tissue sections. An immunoassay was developed for ochratoxin A (OTA) determination in wine, and ICP-MS detection was compared to conventional photometry by gold nanoparticle tagging and horseradish peroxidase, respectively. Detection limits of the assay were optimized to 0.003 μg L-1, and the quantification range was 0.01–1 μg L-1 for both methods. For LA-ICP-MS-based DNA microarray detection, gold nanoparticle tags were specifically introduced via a streptavidin-biotin linkage. In immunohistochemistry (IHC), up to 20 tumor markers are routinely evaluated for one patient and thus, a common analysis results in a series of time consuming staining procedures. Hence, LA-ICP- MS was elaborated as a detection tool for a novel, multiplexed IHC analysis of tissue sections. Different lanthanides were employed for the simultaneous detection of up to three tumor markers (Her 2, CK 7, and MUC 1) in a breast cancer tissue. Additionally, iodine was employed as a labeling reagent, and a new LA-ICP-MS method for single cell and cell nucleus imaging was developed at 4 μm laser spot size. Iodine was also applied as a new internal standard for tissue samples. Moreover, Pt-protein complexes separated by an optimized 1D and 2D gel electrophoresis were analyzed by LA-ICP-MS. The high spatial resolution of this technique was further demonstrated in a current study of cisplatin toxicity and renal protective strategies in rat kidney tissue by detecting platinated proteins.
Mycotoxins are toxic secondary metabolites of ubiquitously occurring moulds. Through the consumption of contaminated foods, they can cause acute or chronic intoxications in humans. Here, it is demonstrated how covalent hydrazine chemistry can be used to improve the performance of instrumental methods for the quantification of trace level food mycotoxins. In the case of the Alternaria mycotoxin tenuazonic acid, pre-column derivatisation with 2,4-dinitrophenylhydrazine resolved chromatographic issues due to the chemical properties of the analyte and allowed for its rapid, sensitive and selective quantification in cereals and beer by high performance liquid chromatography- ion-trap two stage mass spectrometry (HPLC-IT-MS2). Tenuazonic acid could be detected for the first time in beer and buckwheat flour. Although the encountered levels were too low to cause acute intoxications, the frequency of contamination indicated possible health risks due to chronic exposure. In a second scenario, dynamic covalent hydrazine chemistry (DCHC) was exploited for a novel extraction and cleanup method applicable to the Fusarium mycotoxin zearalenone occurring in edible oils. Zearalenone was extracted by hydrazone formation on a hydrazinefunctionalised polymer resin and subsequently released hydrolytically for quantification by HPLC-fluorescence detection (HPLC- FLD). The high selectivity of the approach allowed for the omission of MS detection and immunoaffinity cleanup. The DCHC method was superior to previously published methods in terms of handling efforts, cost, precision and selectivity and is well suited for the monitoring of the current European maximum level for zearalenone in refined maize oil. In the second part of the dissertation, possible degradation routes of Alternaria mycotoxins upon storage and bread baking are discussed. In the frame of a kinetic study, it was shown that tenuazonic acid is degraded by two parallel processes, deacetylation and epimerisation, when stored in aqueous solution (half-life at 25 °C ~ 74 days). The primary degradation product deacetyl tenuazonic acid was less stable than its parent compound and degraded rapidly in beverage matrices. In model baking experiments it was furthermore revealed that alternariol, alternariol monomethyl ether and altenuene are stable under typical baking conditions. A newly identified degradation route, which is based on a sequence of hydrolysis and decarboxylation, caused only minor substance losses (< 1 %). Still, the degradation products could be detected in commercial rusk and crispbread by HPLC-tandem mass spectrometry (HPLC-MS/MS).
Advances and Applications of Molecular Absorption Spectrometry: from Non-Metals to Isotope Analysis
(2019)
The present work covers two main aspects of high-resolution continuum source graphite furnace molecular absorption spectrometry (HR-CS-GFMAS), an analytical technique for elemental trace analysis.
First, a comprehensive mechanistic study of molecule formation in graphite furnaces is presented, which is a key step into the recovery of analytical signals. For this, the molecule formation of CaF was studied, which is used for the indirect analytical determination of fluorine in HR-CS-GFMAS. A zirconium coating catalyzes the CaF formation, and its structure was investigated. The kinetics of this reaction was established by monitoring its molecular spectrum at different atomisation temperatures. An Arrhenius plot showed a pseudo-first order reaction with respect to fluorine (n = 1). An intermediate state was isolated, and its structure was elucidated by spectroscopic methods: scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDX), X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XANES and EXAFS), and Raman microspectroscopy. Here a mechanism is proposed, where ZrO2 works as a heterogeneous catalyst: after a pyrolytic step, an intermediate state of ZrO(OCaF) is activated, and at higher temperatures, CaF(g) is released from the zirconium-coated graphite surface.
Second, analytical methods were developed by using HR-CS-MAS as detector for non-metals and isotope analysis. Therefore, the determination of organic absorbable chlorine in water, the quantification of fluorine in consume care products with declared perfluorinated ingredients, and the determination of sulfur content in crude oils were investigated. Finally, the high resolution of the instrumentation allows to measure isotopic shifts with high precision in some observed molecular spectra. Consequently, the molecular spectra of enriched isotopes of boron and magnesium were investigated, establishing so the potential of HR-CS-MAS for the accurate and precise determination of isotopic amount ratios.
Zusammenfassung
Die vorliegende Arbeit befasst sich mit zwei zentralen Aspekten der High-Resolution-Continuum-Source-Molekülabsorptionsspektrometrie mit Graphitrohrtechnik (HR-CS-GFMAS), einer Analysetechnik für elementare Spurenanalyse.
Der erste Teil der Arbeit umfasst eine mechanistische Studie zur Molekülbildung auf Graphitoberflächen. Dies ist ein wichtiger Schritt, um analytische Signale zu entdecken. Dazu wurde die Molekülbildung von CaF analysiert, welches für die indirekte, analytische Bestimmung von Fluor in HR-CS-GFMAS genutzt wird. Die CaF Bildung wurde mittels einer Beschichtung aus Zirconium katalysiert und deren Struktur analysiert. Die Kinetik dieser Reaktion wurde durch Beobachtung des jeweiligen Molekülspektrums bei verschiedenen Atomisierungstemperaturen beobachtet. Ein Arrheniusplot zeigte für Fluor (n = 1) eine Reaktion Pseudo-erster Ordnung. Ein Übergangszustand wurde über die mit Zirconium überzogene Grafitoberfläche isoliert und seine Struktur mittels spektroskopischer Methoden Energiedispersive Rasterelektronenmikroskopie / Röntgenspektroskopie (REM-EDX), Röntgenphoto¬elektronenspektroskopie (XPS), Röntgenabsorptionsspektroskopie (XAS) und Raman Spektroskopie untersucht. Auf Grundlage dieser Ergebnisse wird ein Mechanismus vorgeschlagen, bei dem ZrO2 als heterogener Katalysator fungiert; in Folge einer Pyrolysestufe wird ein Übergangszustand des ZrO(OCaF) aktiviert, welcher bei höheren Temperaturen CaF(g) an der Zirconium-Graphitoberfläche freisetzt.
Im zweiten Teil der Arbeit werden Analysemethoden entwickelt, in dem HR-CS-MAS als Detektor für Nichtmetalle und Isotopanalyse angewandt wird. Hierfür wurde organisch gebundenes Chlor im Wasser bestimmt, der Fluorgehalt in Pflegeprodukten mit perfluorierten Inhaltsstoffen quantifiziert und der Schwefelgehalt in Erdöl untersucht. Weiterhin ermöglicht die hohe Auflösung der Messgeräte eine präzise Bestimmung der Isotopenverschiebung einiger untersuchter Molekülspektren. Daher wurden die Molekülspektren angereicherter Bor- und Magnesiumisotope untersucht. Auf diese Weise wurde das Potential von HR-CS-MAS für die akkurate und präzise Bestimmung von Isotop-Mengenverhältnissen nachgewiesen.