Filtern
Dokumenttyp
Sprache
- Englisch (5)
Schlagworte
- BST (1)
- Damage detection (1)
- Disposal (1)
- Endosymbionts (1)
- Evolution (1)
- Ferroelectric (1)
- Fully printed component (1)
- Impulse response function (1)
- Issues (1)
- LTCC (1)
Organisationseinheit der BAM
The container of high-level radioactive waste (HLRW) being in deep geological disposal, the backfill material is needed to serve as the second defense for HLRW and the highly compacted bentonite is generally selected. As the time goes, the underground water will infiltrate the backfill, causing the corrosion of materials for the building of containers in the formed electrolyte. Carbon steel, titanium and its alloy are the potential candidate materials for the fabrication of HLRW containers.
The current investigation aims at assessing the safety of HLRW container in deep geological disposal for hundreds of thousands of years and facilitating the material selection for future Container fabrication by estimating their corrosion behavior in compacted bentonite with a series of moisture content at different temperatures through electrochemical methods including open circuit potential (OCP), electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization curve (PC) measurements. The corrosion rates were estimated for a carbon steel, a pure titanium and a titanium alloy in compacted Gaomiaozi Bentonite infiltrated with simulated underground water in Beishan area of China over an expected disposal period up to 106 years respectively, showing that titanium and its alloy are more reliable materials for building HLRW containers than carbon steel.
The primary crystallite size of titania powder relates to its properties in a number of applications. Transmission electron microscopy was used in this interlaboratory comparison (ILC) to measure primary crystallite size and shape distributions for a commercial aggregated titania powder. Data of four size descriptors and two shape descriptors were evaluated across nine laboratories. Data repeatability and reproducibility was evaluated by analysis of variance. One-third of the laboratory pairs had similar size descriptor data, but 83% of the pairs had similar aspect ratio data. Scale descriptor distributions were generally unimodal and were well-described by lognormal reference models. Shape descriptor distributions were multi-modal but data visualization plots demonstrated that the Weibull distribution was preferred to the normal distribution. For the equivalent circular diameter size descriptor, measurement uncertainties of the lognormal distribution scale and width parameters were 9.5% and 22%, respectively. For the aspect ratio shape descriptor, the measurement uncertainties of the Weibull distribution scale and width parameters were 7.0% and 26%, respectively. Both measurement uncertainty estimates and data visualizations should be used to analyze size and shape distributions of particles on the nanoscale.
Defect detection in concrete pile using impulse response measurements with sine sweep excitations
(2015)
For pile integrity inspection, a low cost and portable shaker was used to create the sine sweep signal for pile excitation. The impulse response function, calculated by the deconvolution of pile response from the sine sweep excitation, was proposed to identify the echoes in the piles due to the pile’s impedance changes. The proposed methodology has been evaluated and validated both numerically and experimentally. Based on the results from the simulations and experiments, it was found that the impulse response measurement with sine sweep excitation could be an effective tool to detect the echoes of the pile toe and the defects in the pile.
This paper presents, the investigation of tunable components based on LTCC technology, implementing ferroelectric tunable thick-film dielectric. The tunable loaded line phase shifters are fabricated with metal-insulator-metal (MIM) varactors to demonstrate the capabilities of this method for packaging of the tunable components. The MIM varactors consist of one tunable dielectric paste layer that is printed between two silver layers. The tunable ferroelectric paste is optimized for LTCC sintering temperature around 850°C. The phase shifters are fabricated in two different process. They were achieved a figure of merit of 24°/dB (phase shift 192°) at 3 GHz and 18°/dB (phase shift 98°) at 4.4 GHz by using seven unit cells that each unit cell consisting of two MIM varactors.
Bacteria of the class Endomicrobia form a deepbranching clade in the Elusimicrobia phylum. They are found almost exclusively in the intestinal tract of animals and are particularly abundant in many termites, where they reside as intracellular symbionts in the cellulolytic gut flagellates. Although small populations of putatively free-living lineages have been detected in faunated and flagellate-free hosts, the evolutionary origin of the endosymbionts is obscured by the limited amount of phylogenetic information provided by the 16S rRNA gene fragment amplified with Endomicrobia-specific primers. Here, we present a robust phylogenetic framework based on the nearfull-length 16S–23S rRNA gene region of a diverse set of Endomicrobia from termites and cockroaches, which also allowed us to classify the shorter reads from previous studies. Our data revealed that endosymbionts arose independently at least four times
from different free-living lineages, which were already present in ancestral cockroaches but became associated with their respective hosts long after the digestive symbiosis between termites and flagellates had been established. Pyrotag sequencing revealed that the proportion of putatively free-living lineages increased, when all flagellates and their symbionts were removed from the gut of lower termites by starvation, starch feeding or hyperbaric oxygen, but results varied between different methods.