Filtern
Dokumenttyp
- Zeitschriftenartikel (8)
- Beitrag zu einem Tagungsband (8)
- Vortrag (3)
- Posterpräsentation (3)
Schlagworte
- Distributed fiber sensing (16)
- Acoustic sensing (10)
- Structural health monitoring (8)
- Distributed acoustic sensing (7)
- Leakage detection (5)
- Distributed fiber optic sensing (4)
- DAS (2)
- Fading suppression (2)
- Geothermal borehole (2)
- Ground movement (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (3)
Wavelength scanning coherent optical time domain reflectometer (WS-COTDR) is a good candidate to spatially resolve the environmental information at comparatively low frequency. This paper reveals it can also work as a traditional optical time domain reflectometer (OTDR) to identify Fresnel reflection by averaging the obtained signal over the wavelength scanning range. Simultaneous distributed vibration sensing and a traditional OTDR measurement are experimentally demonstrated using the WS-COTDR system.
Phase-sensitive optical time domain reflectometry (φOTDR) is an excellent distributed fiber sensing technique and has been applied in various areas. Its noise is however never been comprehensively studied to the best of our knowledge. The different detection noise sources in such a sensing system are thoroughly investigated. The impacts of thermal noise, shot noise and the beat between signal and the amplified spontaneous emission from a pre-amplifier have been theoretically and experimentally demonstrated. Due to the random nature of the φOTDR signal, the detection noise demonstrates distinct features at different fiber positions in a single measurement. The theoretical analysis and the experimental result explicitly affirm most of the fiber sections, and the difference at some positions may be explained by ambient noise.
Phase-sensitive optical time domain reflectometry becomes an effective tool to realize distributed sensing, and the optical phase of the received light is usually used to quantify the strain for both dynamic and static measurement. The analysis on the overall phase error has been improved by considering the proportionality of the detection noise to the local optical power. The estimation accuracy is greatly improved by using the proposed theory, the probability density of the estimation accuracy over 99% is > 0.6, ∼39 times larger than the previously reported method. The phase unwrapping may malfunction due to the noisy signal, causing large phase errors. Point break detection algorithms are used to locate the incorrect phase unwrapping points, so the temporal evolution of the phase retrieved at each position can be divided into several sections with different offset. The phase unwrapping error is then suppressed by removing the offset.
Introduction to group 8.6
(2023)
We present a preliminary investigation on distributed humidity monitoring during the drying process of concrete based on an embedded polymer optical fiber (POF). The water dissipated into the POF changes several properties of the fiber such as refractive index, scattering coefficient and attenuation factor, which eventually alters the Rayleigh backscattered light. The optical time Domain reflectometer (OTDR) technique is performed to acquire the backscattered signal at the wavelengths 650 nm and 500 nm, respectively. Experimental results show that the received signal increases at 650 nm while the fiber attenuation factor clearly increases at 500 nm, as the concrete dries out. In the hygroscopic range, the information retrieved from the signal change at 650 nm agrees well with the measurement result of the electrical humidity sensors also embedded in the concrete sample.
Kombinierte faseroptische Messungen in Bohrlöchern helfen bei der Detektion von Kleinstleckagen
(2020)
Seit November 2019 läuft ein breit angelegtes und vom BMWi gefördertes ZIM-Kooperationsprojekt zwischen der Bundesanstalt für Materialforschung und -prüfung (BAM), der IAB'Weimar gGmbH, der GKSO GmbH & Co. Projekt KG, der DEEP.KBB GmbH sowie der Rembe Consulting PartG mbB. Ziel des Forschungsvorhabens sind sowohl die Lokalisierung als auch die Quantifizierung insbesondere sehr kleiner Leckagen in einer Bohrlochverrohrung durch die Nutzung faseroptischer Messtechnik. Durch Messdatenkopplung und den Wegfall bewegungsbedingter Nachteile einer Messsonde werden wesentlich präzisere Ergebnisse zur Bewertung der Bohrlochintegrität als üblich
erwartet.