Filtern
Erscheinungsjahr
- 2010 (10) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (8)
- Vortrag (2)
Sprache
- Englisch (7)
- Deutsch (2)
- Portugiesisch (1)
Schlagworte
- Alternaria (1)
- Bioisomerization (1)
- Breath alcohol (1)
- Brominated flame retardant (1)
- Certification (1)
- Certified reference material (1)
- Chemical derivatisation (1)
- Chromatography (1)
- DDT breakdown (1)
- Degradation (1)
Eingeladener Vortrag
- nein (2)
A first inter-laboratory comparison was conducted to demonstrate and document the capability of interested laboratories to measure the fraction of C—OH species on a plasma oxidised poly(propylene) sample by using a chemical derivatisation XPS approach. This report presents the results from that inter-laboratory comparison and includes the data received for the measured values and their associated standard deviations of laboratory means, at a 95% confidence level. The measurements were guided by a protocol developed within the group before and summarised shortly in the paper. Standard deviations that may characterise the state-of-the-art for the nominally simple and rather often practised case of TFAA chemical derivatisation XPS of C—OH species on a plasma oxidised polyolefin surface are calculated following ISO 5725-2:1994. The main conclusion is that the associated degree of equivalence reached by the participating laboratories in this comparison is still low. Further research to improve chemical derivatisation XPS protocols is mandatory.
The resource-saving utilisation of recovered
waste wood is a matter of growing concern. In several
European countries, this utilisation is governed by regulations
and is dependent on the contents of certain trace
elements and organic compounds. Thus, for decisionmaking
with respect to waste wood management (recycling
or combustion), reliable analytical data are needed and, due
to their great economic and environmental impact, must be
assured by appropriate quality control. To support the
improvement in quality assurance in waste wood analysis,
for the first time, a wood reference material was certified
for its mass fractions of arsenic, cadmium, chromium,
copper, lead, mercury, and pentachlorophenol (PCP).
These analytes were selected because they represent typical
constituents of wood preservatives most widely used in the
past. Material preparation and testing of homogeneity and
stability were carried out by BAM Federal Institute for
Materials Research and Testing. The certification measurements
were performed involving selected laboratories
with documented expertise in the field of waste wood
analysis. The certified values and their corresponding
uncertainties were assigned in full compliance with the
requirements of ISO Guide 35. The certified mass fractions
and their expanded uncertainties (k/i> = 2) are as follows:
(3.1 ± 0.5) mg/kg for As, (3.02 ± 0.24) mg/kg for Cd,
(36.4 ± 2.6) mg/kg for Cr, (22.9 ± 1.7) mg/kg for Cu,
(0.60 ± 0.14) mg/kg for Hg, (39 ± 4) mg/kg for Pb, and
(7.9 ± 0.6) mg/kg for PCP. The certified material is
available as European Reference Material ERM®-CD100.
Ethanol/water solutions as certified reference materials for breath alcohol analyzer calibration
(2010)
The Federal Institute for Materials Research and Testing (BAM), Germany, has issued a series of large volume ethanol in water certified reference materials (CRMs), primarily developed for the calibration of evidential breath alcohol analyzers in Germany. The certified parameter is the ethanol mass concentration at 20 °C. When used in a wet bath simulator, the solutions deliver gas samples that meet the requirements set by the Organization of Legal Metrology for calibration of breathalyzers. The materials were prepared gravimetrically by spiking of ethanol into water in single 5 L units. A complete uncertainty budget for the preparation process has been established. The purity of the commercial ethanol stock solution was identified to be the main source of uncertainty. For stability and homogeneity measurements and for the verification of the gravimetric mass concentration of the CRMs, a robust high-precision gas chromatography, with flame-ionization detection method for ethanol determination in aqueous samples was developed and validated. The good performance of this method has been demonstrated in several international comparisons organized by the Consultative Committee for Amount of Substance-Metrology in Chemistry at the International Bureau of Weights and Measures.
HBCD stereoisomer pattern in mirror carps following dietary exposure to pure Gamma-HBCD enantiomers
(2010)
An international intercomparison involving eight national metrology institutes (NMIs) was conducted to establish their current measurement capabilities for determining five selected congeners from the brominated flame retardant classes polybrominated diphenyl ethers and polybrominated biphenyls. A candidate reference material consisting of polypropylene fortified with technical mixtures of penta-, octa- and decabromo diphenyl ether and decabromo biphenyl, which was thoroughly assessed for material homogeneity and stability, was used as study material. The analytical procedures applied by the participants differed with regard to sample pre-treatment, extraction, clean-up, employed calibrants and type of calibration procedure as well as regarding analytical methods used for separation, identification and quantification of the flame retardant congeners (gas chromatography coupled to an electron capture detector (GC-ECD), gas chromatography-mass spectrometry in the electron ionisation mode (GC-EI-MS), gas chromatography-mass spectrometry in the electron capture negative ionisation mode (GC-ECNI-MS), and liquid chromatography-inductive coupled plasma-mass spectrometry (LC-ICP-MS)). The laboratory means agreed well with relative standard deviations of the mean of means of 1.9%, 4.8%, 5.5% and 5.4% for brominated diphenyl ether (BDE) 47, 183 and 209 and for the brominated biphenyl (BB) congener 209, respectively. For BDE 206, a relative standard deviation of 28.5% was obtained. For all five congeners, within-laboratory relative standard deviations of six measurements obtained under intermediate precision conditions were between 1% and 10%, and reported expanded measurements uncertainties typically ranged from 4% to 10% (8% to 14% for BDE 206). Furthermore, the results are in good agreement with those obtained in the characterization exercise for determining certified values for the flame retardant congeners in the same material. The results demonstrate the state-of-the-art measurement capabilities of NMIs for quantifying representative BDE congeners and BB 209 in a polymer. The outcome of this intercomparison (pilot study) in conjunction with possible improvements for employing exclusively calibrants with thoroughly assessed purity suggests that a key comparison aiming at underpinning calibration and measurement capability (CMC) claims of NMIs can be conducted.
The measurement uncertainty is useful to estimate the confidence of analytical results. Nowadays, a result without the uncertainty statement cannot be considered reliable, but the scientific literature still lacks examples of the estimate of the measurement uncertainty. This paper presents a practical and reliable description of the measurement uncertainty estimation of the analytical determination of ethyl carbamate in cachaça by GC-IDMS. The isotope dilution technique (ID) associated with GC-MS was used to improve the accuracy. The uncertainty estimated corresponds to 10% of the mass fraction of ethyl carbamate (115 ± 11) ng/g, which is in agreement with ppb level.
The degradation kinetics of the Alternaria mycotoxin tenuazonic acid (l-TA) in aqueous buffer were studied over a period of 4 months at different pH levels (3.5 and 7.0) and temperatures (4, 25 and 40°C). l-TA and its degradation products were quantified by newly developed high-performance liquid chromatography methods with UV or electrospray multistage mass spectrometry detection. At pH 3.5, significant degradation occurred at 25 and 40°C, the respective l-TA half-lives being 73.8±0.4 and 14.0±0.1 days. Two degradation processes, epimerization and hydrolysis, were evaluated kinetically. The hydrolytically formed iso-deacetyl TA (iso-DTA, epimeric mixture) was found to be the stable end product of l-TA degradation under the conditions of this study. This indicates that iso-DTA as well as the l-TA epimer u-TA are formed in aqueous beverage matrices.