Filtern
Dokumenttyp
- Forschungsbericht (8) (entfernen)
Referierte Publikation
- nein (8)
Schlagworte
- EU FP7 project NanoValid (2)
- Inter-laboratory comparison (2)
- Silica nanoparticles (2)
- AEROSIL® OX50 (1)
- AES (1)
- Biozide (1)
- Contrast transfer function (1)
- Dispersion of nano materials (1)
- Euramet EMRP (1)
- Gold (1)
Organisationseinheit der BAM
IND15 JRP SurfChem: Traceable quantitative surface chemical analysis for industrial applications
(2016)
The SurfChem project has made a significant contribution to traceable quantitative surface chemical analysis for industrial applications by delivering new certified reference materials and test samples for specific technical applications. Regular performance tests of instruments, metrological methodology for the detection of (bio)organic surface species, ambient and non-destructive surface chemical analysis for in-line process control and new in situ characterisation techniques of catalytically active surfaces have been achieved.
An inter-laboratory comparison on the particle size, expressed as mean diameter d, of nanoscaled SiO2 (#14 BAM Silica (see NanoValid DoW, D.5.41/5.42)) has been performed. The majority of participants used Dynamic Light Scattering (DLS). A few used Electron Microscopy as method. Following methods had been applied by only one partner, respectively: Small Angle X-ray Scattering, Analytical Ultracentrifugation, Atomic Force Microscopy and Atomizer with electric mobility spectrometer.
An inter-laboratory comparison on the surface charge, expressed as zeta potential ζ, of nanoscaled SiO2 has been performed using #14 BAM Silica (see D.5.41/5.42) nanoparticles. The comparability of results delivered by participants has been tested.
The Task 5.4 of NanoValid is designed to test, compare and validate current methods to measure and characterize physicochemical properties of selected engineered nanoparticles. The measurand is Surface charge expressed as zeta-Potential. The measurements are to be accompanied by estimates of the uncertainties at a confidence level of 95%, deduced from the standard uncertainties. Therefore an uncertainty budget comprising statistical (Type A) and systematic (Type B) errors has to be established and delivered for the measurand. The protocol comprises two Annexes addressing the establishment of uncertainty budgets following GUM. The final goal of the comparison is to identify those methods of measurement which have potential as reference methods in pc characterization of nanoparticles for the determination of a given measurand.
This Report describes an inter-laboratory comparison aiming on the establishment of the used method (BET) as a reference method. Another purpose was the certification of the porous reference material #15 BAM Titania as CRM BAM-P110 (cf. D 5.41/42). The certified values determined by nitrogen ad-sorption at 77.3 K according to the international standards ISO 15901-2 and ISO 9277 are summarized in the Table below.
This report describes a standard operation procedure for dispersion of nanomaterials in liquids prior to toxicological or ecotoxicological testing. Main factors, who determine the state of agglomeration and aggregation of ENMs after dispersion are specific energy input, particle concentration and fluid composition. The method was validated in two round robin tests, where two typical nanomaterials (a nanopowder and a nanodispersion) were investigated. One main result arising out of the data comparison was that only those participants, who were able to follow the instructions in the SOPs completely, received similar results regarding particle size and zeta potential. The SOP is easy to adapt for other types of nanomaterials. The results provide the standardization process and were presented at DIN working group.