Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (36)
- Beitrag zu einem Tagungsband (17)
- Beitrag zu einem Sammelband (8)
- Vortrag (3)
- Posterpräsentation (2)
- Buchkapitel (1)
Sprache
- Englisch (67) (entfernen)
Schlagworte
- DSC (7)
- Ultrasound (7)
- Compression set (6)
- DMA (6)
- Dynamic mechanical analysis (6)
- Elastomer (6)
- Glass transition (6)
- Prepreg (5)
- Epoxy (4)
- Low temperature behaviour (4)
- Sealing material (4)
- Cross-linking (3)
- Crosslinking (3)
- Cure process (3)
- Curemeter (3)
- Dichtungen (3)
- Moulding compound (3)
- Thermoset (3)
- Vitrification (3)
- Vulcanisation (3)
- Vulcanization (3)
- Autoclave (2)
- Biodiesel (2)
- Carbon fibre (2)
- Curing (2)
- Dielectric parameters (2)
- Differential scanning calorimetry (2)
- Dynamic-mechanical analysis (2)
- EVA (2)
- Elastomere (2)
- Elastomers (2)
- Fuel sorption (2)
- Gelation (2)
- Impact strength (2)
- Low temperature (2)
- Microwave methods (2)
- PE-HD (2)
- Phenolic resin (2)
- Rheology (2)
- Sound velocity (2)
- Tieftemperaturverhalten (2)
- Ultraschall (2)
- Acoustic propagation (1)
- Adhesion (1)
- Atomic force microscope (1)
- Bauteilversuche (1)
- CFC (1)
- CRP (1)
- Cellular polypropylene (1)
- Charpy impact test (1)
- Component test (1)
- Composite material (1)
- Composites (1)
- Cross linked polyethylene insulation (1)
- Crystal melting (1)
- Cure monitoring (1)
- Curing behaviour (1)
- Curing degree (1)
- DMTA (1)
- Degree of cure (1)
- Degree of curing (1)
- Desorption (1)
- Devitrification (1)
- Dielectric relaxation (1)
- Differential Scanning Calorimetry (1)
- Druckverformungsrest (1)
- Dynamic Mechanical Analysis (1)
- Elastic-plastic properties (1)
- Epoxy system (1)
- Ethylene vinyl acetate (1)
- Ferroelectret (1)
- Ferroelectric polymer (1)
- Fertigungskontrolle (1)
- Filled rubber compounds (1)
- Force-distance curves (1)
- Glass transition temperature (1)
- High pressure DSC (1)
- High temperature (1)
- Incoming goods inspection (1)
- Indentation (1)
- Injection moulding (1)
- Interdiffusion (1)
- Interphase/interface (1)
- Kinetic (1)
- Leakage rate (1)
- Mechanical variables measurement (1)
- Melamine (1)
- Modulus (1)
- Monitoring (1)
- Mould (1)
- Mould wall coupling (1)
- Natural rubber (1)
- O-Ringe (1)
- O-ring (1)
- On-line monitoring (1)
- Online control (1)
- P(VDF-HFP) (1)
- Phenol (1)
- Poly(vinylidene(fluoride - hexafluoropropylene) (1)
- Polymer (1)
- Post curing (1)
- Post-curing (1)
- Process controlling (1)
- Process optimization (1)
- Prozesskontrolle (1)
- Qualitätssicherung (1)
- RTM (1)
- Reaction kinetic (1)
- Relaxation (1)
- Resin transfer moulding (1)
- Resins (1)
- Rheologie (1)
- Rtm (1)
- Rubber seals (1)
- Schallgeschwindigkeit (1)
- Seal (1)
- Sensors (1)
- Silicone rubber (1)
- Sound damping (1)
- Spectroscopy (1)
- TMDSC (1)
- Temerature (1)
- Thermal analysis (1)
- Thermal properties (1)
- Thermoset manufacturing (1)
- Thermosets (1)
- Tiefe Temperatur (1)
- Time-temperature superposition principle (1)
- Ultrasonic (1)
- Ultrasonic monitoring (1)
- Ultrasound sensors (1)
- Uniaxial stretching (1)
- Urea rsin (1)
- Vernetzungsreaktion (1)
- Viscoelastic (1)
- Vulkanisation (1)
- tan delta (1)
Eingeladener Vortrag
- nein (3)
Partial discharges may cause damage to electrical insulation of high voltage equipment. They initiate elastic waves in the insulating material, e.g. in the stress cone of an outdoor termination. Localisation of the origin of such elastic waves can help to predict serious damaging processes in the electrical insulation. In order to measure and evaluate the wave propagation effects in typical multilayered elastomeric structures, knowledge of the material properties is required. The propagating velocity and the attenuation of longitudinal waves are important parameters. Values for these quantities found in the literature were not appropriate. Therefore, for cross-linked polyethylene (XLPE) and cured liquid silicone rubber (LSR), the longitudinal wave velocity and the attenuation were evaluated in the temperature interval from -20°C to 50°C and in the frequency range from 200 kHz to 600 kHz using a two-sample ultrasound technique. The loss factor was determined from these measured quantities. Additionally, low frequency Dynamic Mechanical Thermal Analysis (DMTA) was applied to investigate LSR and XLPE in a temperature interval between -100 and 50°C and to check qualitatively the ultrasound data.
In processing fibre-reinforced composites, the curing reaction can be significantly retarded if the temperature and reaction time are not optimally set. In such situations, complete curing is sometimes impossible under practically relevant conditions. It is difficult for processors to recognize or detect incomplete curing. The equilibrium glass transition temperature plays an important role in complete curing in the production process.
In recent years eure monitoring with ultrasonic methods became more important. An on-line measurement System for industrial applications is presented in this paper. It operates in through-transmission and the measured parameters are the sound velocity and the attenuation of the sound wave. An objective of this paper is to establish the ränge of possible applications for an ultrasonic eure monitoring System.
Ultrasound on-line NDT methods have been demonstrated as a useful tool for monitoring the curing reaction of thermosets. In order to achieve this ultrasound sensors are incorporated into compression, injection and RTM (resin transfer) mould. For many commercial products imprints or any surface markings upon the moulded product are undesirable. Due to its physical properties ultrasound has a large advantage over other techniques for similar applications. The sound wave can pass through the wall of the mould and direct contact with the moulded part is not required. In this particular case one fundamental problem is a good coupling of the sensors to the mould wall. Several mediums came into question but because of the high technical (e. g. temperature and long time stability) and practical demands, it was decided that dry (non-fluid) coupling would be the most promising candidate. A handful of coupling foils suitable also at high temperatures and for long time application under industrial conditions were tested and are presented in this paper.
The application of microwave measurements to the characterisation of rubber compounds vulcanisation is considered. The behaviour of mechanical and microwave (20 GHz) dielectric parameters during vulcanisation was investigated for rubber compounds with different concentrations of active and non-active carbon black. An increase of concentration or activity of carbon black results in the increase of both dielectric permittivity ε?(T) and loss ε?(T) and in the increase of torsion modulus as well. The start of the vulcanisation reaction is indicated by an increase of dielectric permittivity and torsion modulus in all investigated unvulcanised compounds with carbon black. While for compounds with non-active carbon black the vulcanisation can be better indicated by the ε?(T) anomaly, for compounds with active carbon black it is more clearly seen by the change of ε?(T) behaviour.
Ultrasound waves penetrate solid objects without damaging them. Their fields of application range from the imaging of internal organs in medicine, to interior testing of mechanical and chemical engineering components. However, ultrasonic systems can also be used to visualise the way the mechanical properties of reactive resins change during processing in the mould.
The curing conditions play an important role in the quality assurance of composite products.
Especially as composite materials are widely used in high tech areas so that they are required to fulfil high quality Standards. Some problems which occur during curing, for instance undercuring, can hardly be detected using Standard NDT investigations, mainly because they are manifested only at high temperatures, particularly close to glass-rubber-transition. On-line eure monitoring has the outstanding advantage that it can monitor the material parameters even at the highest temperatures possible.
In recent years eure monitoring with ultrasonic methods has become more populär. In comparison to dielectric methods mechanical parameters are measured directly. The quantities to be measured are the velocity and the attenuation of the sound wave. On this basis the storage and loss modulus can be calculated. Depending on the form of excitation with longitudinal or transversal waves these moduli are referred to as long wave or shear modulus.
Well developed Computer based technology and sensor materials are available in the non-destructive testing (NDT) market. The measuring equipment employed a commercial NDT System, which worked computer-aided. With a special Software the demands of automatic Operation under industrial conditions was accomplished. This measurement equipment was tested on composites. Its structure, performance and some practical results will be presented in the following paper.
Post-annealing of thermosets
(2006)
Adhesion of amorphous polymers as a function of temperature probed with AFM force-distance curves
(2005)
Forcedisplacement curves have been obtained with a commercial atomic force microscope at different temperatures and probe rates on a thick film of poly(n-butyl methacrylate) and on two films of polystyrene with different molecular weight. In a previous publication [B. Cappella, S.K. Kaliappan, H. Sturm, Macromolecules 38 (2005)1874] the analysis of forcedisplacement curves has been focused on the stiffness and on the Young's modulus of the samples. In the present publication we consider the temperature dependence of the work of adhesion. We have obtained master curves of the work of adhesion at fixed maximum loads and, by comparing the results of the two analysis, we show that the work of adhesion follows the WilliamsLandelFerry equation with the same coefficients previously found for the Young's modulus. Furthermore, we show that the temperature dependence of the work of adhesion of the polymers is a consequence of the temperature dependence of the tipsample contact area and in the end of the temperature dependence of the stiffness and of the elasticplastic properties of the samples.
Rubbers are widely used as main sealing materials for Containers for low and intermediate level radioactive waste and as additional component to metal seals in spent fuel and high active waste containers. The save enclosure of the radioactive container inventory has to be guaranteed according to legislation and appropriate guidelines for long term storage periods as well as down to temperatures of -40 °C for transportation. Therefore the understanding of failure mechanisms that lead to leakage at low temperatures is necessary to ensure a proper material choice which is certainly also influenced by additional factors as e.g. the aging behavior.
The investigation of low temperature properties of elastomeric sealing materials by means of thermo-analytical methods is a sound way to get information about the glass transition process.
The breakdown temperature of the sealing function of O-ring seals was measured in a component test setup depending on material and degree of compression.
An in depth explanation of the observed component tests behaviour is currently in preparation. It requires the results of thermo-analytical methods and measurements as the compression set (not shown here). With that, a model was developed to describe the correlation between physical material parameters and observed component behaviour.
Rubbers are often used for seal applications due to their special material properties and easy use. In many applications the material is exposed to low temperatures during Operation. Therefore it is important to know the material behavior at low temperatures to determine the temperature ränge that allows a Safe Operation of the seal, e.g. in storage and transport Containers for radioactive materials.
The seal function of an elastomer is limited in temperature by the rubber-glass transition during which the material properties change from rubber-like to stiff and glass-like. For a given application this correlation is not trivial and therefore needs an in-depth investigation under consideration of the physical properties and the
application conditions.
In this work different analytical methods are used to characterize the material behavior at low temperature in the ränge of the glass-rubber-transition and are compared with the quality of Operation of a component which is here defined by the detected leakage rate.
Carbon fibre prepregs have found widespread application in lightweight constructions. They are based on a carbon fibre fabric impregnated with reactive epoxy resin. Measurements were carried out using commercially available prepreg material. For Dynamic Mechanical Analysis (DMA), a single cantilever measuring device was applied. The DMA results were refined by additional DSC measurements. The measurements were carried out with dynamic heating in the temperature range -90 to 280 °C. The heating rates were 1 and 2 K/min, respectively. A glass transition of the uncured material (Tg0) near 1 °C, and crosslinking-induced vitrification and devitrification at the maximal glass transition temperature of the cured material (Tgmax) in the temperature range 220 to 230 °C were found. The activation energies for the glass transitions were determined using an Arrhenius plot. By detailed consideration of the influence of the frequency on the DMA data, indications for gelation were deduced.
EVA is a widely used material for the encapsulation of photovoltaic modules. It melts at elevated temperatures, and seals the module before it is crosslinked at temperatures above 130 °C by a peroxide-initiated crosslinking reaction. EVA has good optical properties necessary for application in solar modules. For process optimization and quality management, a method for the quick and reliable characterization of EVA crosslinking behaviour is of great value. Here, the practicability of ultrasound for online crosslinking monitoring is demonstrated. A sound velocity increase of about 8 m/s during the crosslinking reaction is found. The ultrasound results are compared with rheometer measurements performed with a curemeter typically used for the investigation of rubber crosslinking.
A stoichiometric amineepoxy formulation was cured in the presence of a thermoplastic, namely poly(vinylpyrrolidone) (PVP). The epoxy system consisted of the resin diglycidyl ether of bisphenol A (DGEBA) and the aromatic curing agent 4,4'-diaminodiphenylsulfone (DDS). As shown for this system in a former study by Oyama et al. [Oyama HT, Lesko JJ, Wightman JP. J Polym Sci B 1997;35:33146. [36]], preferential absorption of amine molecules by PVP can occur. In the present study, the focus is on the variations of local elastic properties within the epoxy interphase adjacent to the PVP layer. The curing was performed close to the glass transition temperature, Tα, of the PVP film, namely at 170 °C. Variations of the local amine concentration were tracked using energy-dispersive analysis of X-rays (EDX), by taking benefit of the sulfur contained in DDS. Using temperature-dependent dynamic mechanical analysis (DMA), a series of epoxy reference samples of different amineepoxy concentration ratios, r, was investigated in order to work out the relationship between r and the epoxy storage modulus at room temperature. In the excess-epoxy regime, r<1, the modulus is observed to increase with departure from the stoichiometric ratio, r=1. Considering the respective suppression of the ß-transition, the observed characteristic can be explained by an antiplasticisation effect. Depth-sensing indentation (DSI) experiments across the epoxy/PVP interphase provided evidence for strong modulus variations. In consistency with the EDX and the DMA data, in the vicinity of the PVP layer the local epoxy modulus is increased. The total change of the epoxy Young's modulus is ~1.1 GPa. However, the total width of the modulus decay of ~175 µm is ~2.5 times larger than the one of the DDS concentration gradient. This finding is discussed in terms of additional spatial variations of the DGEBA concentration as well as long-range diffusion currents of DDS induced by the interdiffusion processes and their effect on the final network of crosslinks.
Two different approaches to investigate the local complex conductivity and the surface charge with Scanning Force Microscopy (SFM) techniques are presented. It is shown that the measurement of local electrical properties with SFM leads to interesting information about the composition of electrically heterogeneous surfaces
With an extended contact and non-contact mode scanning force microscope samples with different heterogeneous electrical properties can be characterized. The contact mode method allows the determination of local electric conductivities of heterogeneous systems at the sample surfaces. An interpretation of this behaviour can be obtained in combination with other SFM modes such as topography, friction and compliance used simultaneously. The non-contact mode SFM allows to get more information about the local surface charge of heterogeneous samples. In this paper two new SFM approaches will be discussed on examples of carbon-fibre reinforced, organic and ceramic materials
Investigation of curing of epoxy resin composite materials by dynamic mechanical analysis (DMA)
(2006)
Making Cure Visible
(2005)
The prospects of modern thermoanalytical methods for characterisation
of flow, curing and final mechanical behaviour of
moulding compounds were demonstrated. Using urea resin
moulding compounds from different manufacturers the possibilities
of the various techniques could be shown. With comparatively
low effort, fundamental information can be gained
before production process had been started. On this basis it is
possible to make appropriate material selection at an early
point in the process chain. On the basis of thermoanalytical
data an incoming goods inspection can be established. Also it
is easy to control the compliance with the conditions of delivery.
In some cases it could also be helpful to have stored analysis
data especially when problems appear in manufacturing
process or unexpected part damages occur
With the ultrasound measuring system it is possible to transfer
the findings from the analytical methods directly to the processes
in the mould. The application of ultrasound provides
Dynamic Mechanical Analysis in the mould. Beside quality
assurance ultrasound can also be used for process optimisation,
especially for reduction of cycle time. In an advanced form
ultrasound information can be used as a basis for improved
machine control based on material state. The ultrasound measuring
system developed by ISK Iserlohn and BAM can be
obtained from the ISK.
Carbon-fibre prepregs have found widespread use in lightweight applications. They are based on a carbon-fibre fabric impregnated with reactive epoxy resin. Prepreg materials are generally pre-cured so that they have a higher molecular weight than typical resins in order to reduce resin flow, which facilitates storage and later processing properties.
The measurements were carried out using commercially available materials and follow the published DMA investigations of the same material. TMDSC was used to find the correlation between curing conditions, the degree of cure and glass transition temperature. TMDSC has the advantage over standard DSC that it enables better determination of the glass transition temperature, which is often accompanied by an exothermic curing reaction, and thus overshadowed. The influence of the amplitude of temperature modulation was tested in preliminary experiments. For non-cured material a glass transition temperature of approximately 0 °C was determined; whereas for the totally cured material it was approximately 230 °C. The changes in degree of cure, temperature of actual glass transition and post-reaction are given as a function of curing time at 180 °C. The correlation between actual glass transition temperature and degree of cure is derived.
Commercially available melamine/phenolic (MP) moulding compounds used for manufacturing electro installation parts were investigated by laboratory thermal analysis methods: Dynamic Mechanical Analysis (DMA), Differential Scanning Calorimetry (DSC) and Dielectric Analysis (DEA). The results were compared with on-line measurements in a compression mould using incorporated dielectric and ultrasound sensors. Softening and cross-linking behaviour were analyzed. For on-line process monitoring, only the ultrasound method worked well. The dielectric method was distorted by water formed as a by-product from the poly-condensation reaction.
Two types of commercially applied Ethylene/Vinyl Acetate Copolymers (EVA) for encapsulation of photovoltaic modules were investigated by the thermal analysis methods of Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) in the temperature range from -150 °C to 200 °C. Glass transition, crystal melting and cross-linking were analyzed. The aims of the investigations were to gain more information for incoming goods control and to get information about the whole temperature dependent material properties in the investigated temperature range, starting at very low temperatures up to the crosslinking temperature region.
The method for the determination of compression set values with a Dynamic Mechanical Analysis (DMA) setup at low temperatures, which was presented previously, allows a much faster and readily automated procedure than the standardized compression set test according to ISO 815-2. This method is applied to a series of different elastomeric materials that are commonly used for sealing applications. The results of the compression set test are compared with results from thermal analysis to allow an in depth comparison of the material behaviour at low temperatures.
Furthermore, a comparison between two EPDM materials is presented. These materials show very similar properties determined by thermo analytical methods such as Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) but differ clearly in their compression set behaviour. This comparison shows the importance and value of information of the compression set test in addition to thermal analysis to judge the behaviour of sealing materials and confirms the relevance of the new compression set test method for the investigation of low temperature properties of elastomers.
The time-dependent sorption of biodiesel in a typical polyethylene for container applications is investigated in comparison to conventional diesel fuel at three different temperatures. In this context, the desorption behavior is also addressed. Subsequently, the effects of both penetrants on mechanical properties are characterized in terms of impact strength and dynamic-mechanical analysis. The discussion of property changes is firstly based on the sorption kinetics of biodiesel and diesel, which is determined by immersion experiments allowing for the calculation of respective diffusion coefficients. Changes in impact strength as determined by the Charpy method are further characterised in more detail by analyzing the fracture surfaces, and correlated with results of dynamic-mechanical analysis.
Non-destructive evaluation (NDE) of composites: using ultrasound to monitor the curing of composites
(2013)
Typical composite materials for lightweight construction consist of a fibre (glass or carbon) reinforced thermosetting matrix. The impregnation of the fabric is made with liquid resin – usually epoxy resin or unsaturated polyester resin are used. The main processing methods are resin transfer moulding (RTM) and prepreg technology often used in combination with autoclave curing. After shaping, the resin must be cured. The final properties of the produced parts depend on the curing degree and the final glass transition temperature. Analytical methods and the use of ultrasound for online cure monitoring in the manufacturing process are introduced. Examples for the application of ultrasonic cure monitoring for the production of composite parts for traffic systems are also covered.
To achieve the required tightness levels of Containers for low and intermediate level radioactive wastes rubbers are widely applied as main sealing materials. The save encapsulation of the radioactive Container contents has to be guaranteed according to legislation and appropriate guidelines for long storage periods as well as down to temperatures of-40 °C during transportation.
Therefore the understanding of failure mechanisms that lead to leakage at low temperatures is of high importance.
It is known that the material properties of rubbers are strongly influenced by temperature. At low temperatures this is caused by the rubber-glass transition (abbr. glass transition). During continuous cooling the material changes from rubber-like entropy-elastic to stiff energy-elastic behaviour, that allows nearly no strain or retraction. Therefore, rubbers are normally used above their glass transition but the minimum working temperature limit is not defrned precisely, what can cause problems during application. The temperature ränge where full functionality is possible is strongly dependent on the application conditions and the material.
For this investigation mainly ethylene propylene diene (EPDM) and fluorocarbon rubbers (FKM) were selected as they are often used for radioactive waste Containers.
Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) are typically used for the determination of the temperature ränge of the glass transition process. The standardized compression set measurement according to ISO 815 is common for investigation of rubber sealing materials as the test simulates the seal behaviour after release. To reduce the test time of the Standard tests a faster technique giving the same information was developed.
Additionally, the breakdown temperature of the sealing function of complete O-ring seals is measured in a component test Setup to compare it with the results of the other tests. The experimental Setup is capable of measuring the leakage rate at low temperatures by the pressure rise method.
A model was developed that allows calculating the minimum working temperature limit of a seal by combining the results of the applied methods.
Rubbers are widely used as sealing material in various applications. In many fieldsthefunction of seal materials at lowtemperatures is required. Therefore the understanding of faiiure mechanisms that lead to leakage at low temperatures is of high importance. Therefore the lower Operation temperature limit of rubber seals should be determined in dependence of the material properties.
The results of Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) are combined with results of standardized measurements as the compression set according to ISO 815. To reduce the test time of the Standard tests a faster and more efficient technique was developed and applied. In addition the breakdown temperature of the sealing function of O-ring seals at lowtemperatures is measured in a component test Setup in dependence of the material and the degree of compression.
Carbon fibre prepregs have found widespread application in lightweight constructions. They are based on a carbon-fibre fabric impregnated with reactive epoxy resin. DMA measurements under temperature conditions similar to an autoclave programme were carried out using commercially available prepreg material with a high glass transition temperature. The characteristic of the temperature programme was a dynamic heating segment at 1.5 K/min followed by a longer isothermal segment at 180 °C. The courses of the storage modulus E', loss modulus E'' and tanδ were recorded. The measuring frequency was varied between 1 Hz and 33.3 Hz. Gelation and vitrification are assigned. The influence of the measuring frequency on the time to vitrification and the correlation with DSC are discussed. The reaction does not end even after 10 h curing at 180 °C, which is interpreted as the slow cessation of the reaction caused by vitrification.
Viscoelastic properties of cellular polypropylene ferroelectrets (PP FEs) were studied at low
frequencies (0.3–33 Hz) by dynamic mechanical analysis and at high frequencies (250 kHz) by laser Doppler vibrometry. Relaxation behavior of the in-plane Young’s modulus (Y´
11~1500 MPa at room temperature) was observed and attributed to the viscoelastic response of polypropylene matrix.
The out-of-plane Young’s modulus is very small (Y´33≈0.1 MPa) at low frequencies, frequency- and stress-dependent, evidencing nonlinear viscoelastic response of PP FEs. The highfrequency mechanical response of PP FEs is shown to be linear viscoelastic with Y´33≈0.8 MPa. It is described by thickness vibration mode and modeled as a damped harmonic oscillator with one degree of freedom. Frequency dependence of Y*33 in the large dynamic strain regime is described by the broad Cole-Cole relaxation with a mean frequency in kHz range attributed to the Dynamics of the air flow between partially closed air-filled voids in PP FEs. Switching-off the relaxation contribution causes dynamic crossover from the nonlinear viscoelastic regime at low frequencies to the linear viscoelastic regime at high frequencies. In the small strain regime, contribution of the air flow seems to be insignificant and the power-law response, attributed to the mechanics of polypropylene cell walls and closed air voids, dominates in a broad frequency range. Mechanical Relaxation caused by the air flow mechanism takes place in the sound and ultrasound frequency range (10 Hz–1MHz) and, therefore, should be taken into account in ultrasonic applications of the PP FEs deal with strong exciting or receiving signals.