Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (36) (entfernen)
Schlagworte
- DSC (7)
- Compression set (5)
- Elastomer (5)
- Glass transition (5)
- Crosslinking (4)
- DMA (4)
- Prepreg (4)
- Cross-linking (3)
- Cure process (3)
- Curemeter (3)
- Dielectric parameters (3)
- Dynamic mechanical analysis (3)
- Elastomers (3)
- Low temperature behaviour (3)
- Microwave methods (3)
- Sealing material (3)
- Ultrasound (3)
- Vulcanisation (3)
- Aushärtung (2)
- Biodiesel (2)
- Carbon fibre (2)
- DMTA (2)
- Dynamic-mechanical analysis (2)
- EVA (2)
- Epoxy (2)
- Fuel sorption (2)
- Impact strength (2)
- Low temperature (2)
- Monitoring (2)
- Moulding compound (2)
- PE-HD (2)
- Sensoren (2)
- Thermoset (2)
- Thermosets (2)
- Ultraschall (2)
- Vitrification (2)
- Vulcanization (2)
- Acoustic propagation (1)
- Adhesion (1)
- Atomic force microscope (1)
- Autoclave (1)
- Bauteilversuche (1)
- CFC (1)
- CRP (1)
- Cellular polypropylene (1)
- Charpy impact test (1)
- Component test (1)
- Composite material (1)
- Composites (1)
- Cross linked polyethylene insulation (1)
- Crystal melting (1)
- Cure (1)
- Curing (1)
- Degree of cure (1)
- Degree of curing (1)
- Desorption (1)
- Devitrification (1)
- Dichtungen (1)
- Differential scanning calorimetry (1)
- Druckverformungsrest (1)
- Elastic-plastic properties (1)
- Elastomere (1)
- Epoxy system (1)
- Ethylene vinyl acetate (1)
- Ferroelectret (1)
- Filled rubber compounds (1)
- Force-distance curves (1)
- Gelation (1)
- Glass transition temperature (1)
- Glasübergang (1)
- Indentation (1)
- Interdiffusion (1)
- Interphase/interface (1)
- Keramische Grünfolien (1)
- Leakage rate (1)
- Materialparameter (1)
- Mechanical variables measurement (1)
- Mechanische Prüfung (1)
- Melamine (1)
- Nasschemische Analyse (1)
- Natural rubber (1)
- O-Ringe (1)
- O-ring (1)
- Online control (1)
- Ozonbeständigkeit (1)
- Ozonkonzentrationsbestimmung (1)
- Phenol (1)
- Phenolharze (1)
- Phenolic resin (1)
- Polymer (1)
- Post-curing (1)
- Process controlling (1)
- Prozesskontrolle (1)
- Relaxation (1)
- Resins (1)
- Rheology (1)
- Rubber seals (1)
- Schubmodul (1)
- Seal (1)
- Silicone rubber (1)
- Spectroscopy (1)
- TMDSC (1)
- Temerature (1)
- Thermal analysis (1)
- Thermal properties (1)
- Thermische Analyse (1)
- Tiefe Temperatur (1)
- Time-temperature superposition principle (1)
- UV-Spektroskopie (1)
- Ultrasonic monitoring (1)
- Verlustmodul (1)
- Viscoelastic (1)
- Vulkanisation (1)
Partial discharges may cause damage to electrical insulation of high voltage equipment. They initiate elastic waves in the insulating material, e.g. in the stress cone of an outdoor termination. Localisation of the origin of such elastic waves can help to predict serious damaging processes in the electrical insulation. In order to measure and evaluate the wave propagation effects in typical multilayered elastomeric structures, knowledge of the material properties is required. The propagating velocity and the attenuation of longitudinal waves are important parameters. Values for these quantities found in the literature were not appropriate. Therefore, for cross-linked polyethylene (XLPE) and cured liquid silicone rubber (LSR), the longitudinal wave velocity and the attenuation were evaluated in the temperature interval from -20°C to 50°C and in the frequency range from 200 kHz to 600 kHz using a two-sample ultrasound technique. The loss factor was determined from these measured quantities. Additionally, low frequency Dynamic Mechanical Thermal Analysis (DMTA) was applied to investigate LSR and XLPE in a temperature interval between -100 and 50°C and to check qualitatively the ultrasound data.
In recent years eure monitoring with ultrasonic methods became more important. An on-line measurement System for industrial applications is presented in this paper. It operates in through-transmission and the measured parameters are the sound velocity and the attenuation of the sound wave. An objective of this paper is to establish the ränge of possible applications for an ultrasonic eure monitoring System.
The application of microwave measurements to the characterisation of rubber compounds vulcanisation is considered. The behaviour of mechanical and microwave (20 GHz) dielectric parameters during vulcanisation was investigated for rubber compounds with different concentrations of active and non-active carbon black. An increase of concentration or activity of carbon black results in the increase of both dielectric permittivity ε?(T) and loss ε?(T) and in the increase of torsion modulus as well. The start of the vulcanisation reaction is indicated by an increase of dielectric permittivity and torsion modulus in all investigated unvulcanised compounds with carbon black. While for compounds with non-active carbon black the vulcanisation can be better indicated by the ε?(T) anomaly, for compounds with active carbon black it is more clearly seen by the change of ε?(T) behaviour.
Angesichts der spezifischen Bedeutung der Aushärtung von Phenolharzen für ihre Eigenschaften als Ingenieurwerkstoffe besteht großes Interesse an deren quantitativer Charakterisierung. Mittels DSC-Messungen unter hohem Druck (HP-DSC) kann die Vernetzungsreaktion der Phenolharzformmassen durch die Unterdrückung der Verdampfung niedermolekularer Substanzen ohne störende Überlagerungen verfolgt werden. Mittels verschiedener Vernetzungsgrade können die Einflussparameter der Aufheizrate und der Nachtemperung optimiert werden. Die Messergebnisse ermöglichen eine Modellierung der Reaktionskinetik mit dem Ziel einer verbesserten Prozessführung und Qualitätskontrolle in der industriellen Praxis.
Adhesion of amorphous polymers as a function of temperature probed with AFM force-distance curves
(2005)
Forcedisplacement curves have been obtained with a commercial atomic force microscope at different temperatures and probe rates on a thick film of poly(n-butyl methacrylate) and on two films of polystyrene with different molecular weight. In a previous publication [B. Cappella, S.K. Kaliappan, H. Sturm, Macromolecules 38 (2005)1874] the analysis of forcedisplacement curves has been focused on the stiffness and on the Young's modulus of the samples. In the present publication we consider the temperature dependence of the work of adhesion. We have obtained master curves of the work of adhesion at fixed maximum loads and, by comparing the results of the two analysis, we show that the work of adhesion follows the WilliamsLandelFerry equation with the same coefficients previously found for the Young's modulus. Furthermore, we show that the temperature dependence of the work of adhesion of the polymers is a consequence of the temperature dependence of the tipsample contact area and in the end of the temperature dependence of the stiffness and of the elasticplastic properties of the samples.
Rubbers are widely used as main sealing materials for Containers for low and intermediate level radioactive waste and as additional component to metal seals in spent fuel and high active waste containers. The save enclosure of the radioactive container inventory has to be guaranteed according to legislation and appropriate guidelines for long term storage periods as well as down to temperatures of -40 °C for transportation. Therefore the understanding of failure mechanisms that lead to leakage at low temperatures is necessary to ensure a proper material choice which is certainly also influenced by additional factors as e.g. the aging behavior.
Carbon fibre prepregs have found widespread application in lightweight constructions. They are based on a carbon fibre fabric impregnated with reactive epoxy resin. Measurements were carried out using commercially available prepreg material. For Dynamic Mechanical Analysis (DMA), a single cantilever measuring device was applied. The DMA results were refined by additional DSC measurements. The measurements were carried out with dynamic heating in the temperature range -90 to 280 °C. The heating rates were 1 and 2 K/min, respectively. A glass transition of the uncured material (Tg0) near 1 °C, and crosslinking-induced vitrification and devitrification at the maximal glass transition temperature of the cured material (Tgmax) in the temperature range 220 to 230 °C were found. The activation energies for the glass transitions were determined using an Arrhenius plot. By detailed consideration of the influence of the frequency on the DMA data, indications for gelation were deduced.
EVA is a widely used material for the encapsulation of photovoltaic modules. It melts at elevated temperatures, and seals the module before it is crosslinked at temperatures above 130 °C by a peroxide-initiated crosslinking reaction. EVA has good optical properties necessary for application in solar modules. For process optimization and quality management, a method for the quick and reliable characterization of EVA crosslinking behaviour is of great value. Here, the practicability of ultrasound for online crosslinking monitoring is demonstrated. A sound velocity increase of about 8 m/s during the crosslinking reaction is found. The ultrasound results are compared with rheometer measurements performed with a curemeter typically used for the investigation of rubber crosslinking.
A stoichiometric amineepoxy formulation was cured in the presence of a thermoplastic, namely poly(vinylpyrrolidone) (PVP). The epoxy system consisted of the resin diglycidyl ether of bisphenol A (DGEBA) and the aromatic curing agent 4,4'-diaminodiphenylsulfone (DDS). As shown for this system in a former study by Oyama et al. [Oyama HT, Lesko JJ, Wightman JP. J Polym Sci B 1997;35:33146. [36]], preferential absorption of amine molecules by PVP can occur. In the present study, the focus is on the variations of local elastic properties within the epoxy interphase adjacent to the PVP layer. The curing was performed close to the glass transition temperature, Tα, of the PVP film, namely at 170 °C. Variations of the local amine concentration were tracked using energy-dispersive analysis of X-rays (EDX), by taking benefit of the sulfur contained in DDS. Using temperature-dependent dynamic mechanical analysis (DMA), a series of epoxy reference samples of different amineepoxy concentration ratios, r, was investigated in order to work out the relationship between r and the epoxy storage modulus at room temperature. In the excess-epoxy regime, r<1, the modulus is observed to increase with departure from the stoichiometric ratio, r=1. Considering the respective suppression of the ß-transition, the observed characteristic can be explained by an antiplasticisation effect. Depth-sensing indentation (DSI) experiments across the epoxy/PVP interphase provided evidence for strong modulus variations. In consistency with the EDX and the DMA data, in the vicinity of the PVP layer the local epoxy modulus is increased. The total change of the epoxy Young's modulus is ~1.1 GPa. However, the total width of the modulus decay of ~175 µm is ~2.5 times larger than the one of the DDS concentration gradient. This finding is discussed in terms of additional spatial variations of the DGEBA concentration as well as long-range diffusion currents of DDS induced by the interdiffusion processes and their effect on the final network of crosslinks.
Carbon-fibre prepregs have found widespread use in lightweight applications. They are based on a carbon-fibre fabric impregnated with reactive epoxy resin. Prepreg materials are generally pre-cured so that they have a higher molecular weight than typical resins in order to reduce resin flow, which facilitates storage and later processing properties.
The measurements were carried out using commercially available materials and follow the published DMA investigations of the same material. TMDSC was used to find the correlation between curing conditions, the degree of cure and glass transition temperature. TMDSC has the advantage over standard DSC that it enables better determination of the glass transition temperature, which is often accompanied by an exothermic curing reaction, and thus overshadowed. The influence of the amplitude of temperature modulation was tested in preliminary experiments. For non-cured material a glass transition temperature of approximately 0 °C was determined; whereas for the totally cured material it was approximately 230 °C. The changes in degree of cure, temperature of actual glass transition and post-reaction are given as a function of curing time at 180 °C. The correlation between actual glass transition temperature and degree of cure is derived.
Commercially available melamine/phenolic (MP) moulding compounds used for manufacturing electro installation parts were investigated by laboratory thermal analysis methods: Dynamic Mechanical Analysis (DMA), Differential Scanning Calorimetry (DSC) and Dielectric Analysis (DEA). The results were compared with on-line measurements in a compression mould using incorporated dielectric and ultrasound sensors. Softening and cross-linking behaviour were analyzed. For on-line process monitoring, only the ultrasound method worked well. The dielectric method was distorted by water formed as a by-product from the poly-condensation reaction.
Two types of commercially applied Ethylene/Vinyl Acetate Copolymers (EVA) for encapsulation of photovoltaic modules were investigated by the thermal analysis methods of Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA) in the temperature range from -150 °C to 200 °C. Glass transition, crystal melting and cross-linking were analyzed. The aims of the investigations were to gain more information for incoming goods control and to get information about the whole temperature dependent material properties in the investigated temperature range, starting at very low temperatures up to the crosslinking temperature region.
Dargestellt wird eine Gegenüberstellung der Ergebnisse von Messungen zur Ozonkonzentrationsbestimmung nach zwei Verfahren. International wird in der Kautschukindustrie ein UV-spektroskopisches Verfahren angewandt. Die deutsche Kautschukindustrie verwendet ein nasschemisches Verfahren. Die beiden Verfahren ergeben nicht die gleichen Ergebnisse. Daher wird der Unterschied genauer ermittelt.
Die Auswirkungen der unterschiedlichen Ozonkonzentrationsbestimmungen auf die Prüfung der Ozonbeständigkeit an Elastomeren werden gezeigt.