Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (55)
- Vortrag (29)
- Posterpräsentation (27)
- Beitrag zu einem Tagungsband (26)
- Beitrag zu einem Sammelband (16)
- Buchkapitel (1)
Schlagworte
- DMA (9)
- DSC (9)
- Elastomer (9)
- Ultraschall (7)
- Ultrasound (7)
- Compression set (6)
- Dynamic mechanical analysis (6)
- Elastomere (6)
- Glass transition (6)
- Prepreg (6)
- Prozesskontrolle (6)
- Dichtungen (5)
- Vulkanisation (5)
- Crosslinking (4)
- Druckverformungsrest (4)
- Epoxy (4)
- Low temperature behaviour (4)
- Sealing material (4)
- Tieftemperaturverhalten (4)
- Vulcanisation (4)
- Aushärtung (3)
- Cross-linking (3)
- Cure process (3)
- Curemeter (3)
- Dichtung (3)
- Dielectric parameters (3)
- EVA (3)
- Elastomers (3)
- Glasübergang (3)
- Microwave methods (3)
- Moulding compound (3)
- Phenolharz (3)
- Phenolic resin (3)
- Thermoset (3)
- Vitrification (3)
- Vulcanization (3)
- Aushärtegrad (2)
- Autoclave (2)
- Bakelit (2)
- Biodiesel (2)
- Carbon fibre (2)
- Curing (2)
- DMTA (2)
- Differential scanning calorimetry (2)
- Dynamic-mechanical analysis (2)
- Epoxidharz (2)
- Fuel sorption (2)
- Gelation (2)
- Gütesicherung (2)
- High pressure DSC (2)
- Impact strength (2)
- Kochversuch (2)
- Low temperature (2)
- Monitoring (2)
- PE-HD (2)
- Post curing (2)
- RTM (2)
- Reaction kinetic (2)
- Rheology (2)
- Schallgeschwindigkeit (2)
- Sensoren (2)
- Sound velocity (2)
- Thermosets (2)
- Vernetzungsreaktion (2)
- Acoustic propagation (1)
- Adhesion (1)
- Aminoharz (1)
- Atomic force microscope (1)
- Aushärtungsverlauf (1)
- Bauteilversuche (1)
- CFC (1)
- CRP (1)
- Cellular polypropylene (1)
- Charpy impact test (1)
- Component test (1)
- Compositbauteil (1)
- Composite material (1)
- Composites (1)
- Cross linked polyethylene insulation (1)
- Crystal melting (1)
- Cure (1)
- Cure monitoring (1)
- Curing behaviour (1)
- Curing degree (1)
- Degree of cure (1)
- Degree of curing (1)
- Desorption (1)
- Devitrification (1)
- Dielectric relaxation (1)
- Dielektrik (1)
- Differential Scanning Calorimetry (1)
- Dynamic Mechanical Analysis (1)
- Elastic-plastic properties (1)
- Elektroinstallationsteile (1)
- Epoxy system (1)
- Epxidharz (1)
- Ethylene vinyl acetate (1)
- Ferroelectret (1)
- Ferroelectric polymer (1)
- Fertigungskontrolle (1)
- Filled rubber compounds (1)
- Force-distance curves (1)
- Glass transition temperature (1)
- Harnstoffformasse (1)
- Harnstoffharz (1)
- Harnstoffharze (1)
- Harzinjektionsverfahren (1)
- High temperature (1)
- Incoming goods inspection (1)
- Indentation (1)
- Injection moulding (1)
- Interdiffusion (1)
- Interphase/interface (1)
- Isolierstoff (1)
- Kautschuk (1)
- Keramische Grünfolien (1)
- Kinetic (1)
- Klebfolie (1)
- Kunstharze (1)
- Leakage rate (1)
- Lineare Aufheizung (1)
- Materialparameter (1)
- Materialprüfungsamt (1)
- Mechanical variables measurement (1)
- Mechanische Prüfung (1)
- Melamine (1)
- Modulus (1)
- Mould (1)
- Mould wall coupling (1)
- Nasschemische Analyse (1)
- Natural rubber (1)
- O-Ring (1)
- O-Ringe (1)
- O-ring (1)
- On-line monitoring (1)
- Online Prozesskontrolle (1)
- Online control (1)
- Ozonbeständigkeit (1)
- Ozonkonzentrationsbestimmung (1)
- P(VDF-HFP) (1)
- Phenol (1)
- Phenolharze (1)
- Photovoltaik (1)
- Poly(vinylidene(fluoride - hexafluoropropylene) (1)
- Polymer (1)
- Post-curing (1)
- Process controlling (1)
- Process optimization (1)
- Prüfung (1)
- Qualitätssicherung (1)
- Relaxation (1)
- Resin transfer moulding (1)
- Resins (1)
- Rheologie (1)
- Rtm (1)
- Rubber seals (1)
- Schallgeschwindgkeit (1)
- Schrumpf (1)
- Schubmodul (1)
- Seal (1)
- Sensors (1)
- Silicone rubber (1)
- Sound damping (1)
- Spectroscopy (1)
- Spritzgießen (1)
- TMDSC (1)
- Technische Vereinigung (1)
- Temerature (1)
- Thermal analysis (1)
- Thermal properties (1)
- Thermische Analyse (1)
- Thermoanalyse (1)
- Thermoset manufacturing (1)
- Tiefe Temperatur (1)
- Time-temperature superposition principle (1)
- UV-Spektroskopie (1)
- Ultrasonic (1)
- Ultrasonic monitoring (1)
- Ultrasound sensors (1)
- Uniaxial stretching (1)
- Urea rsin (1)
- Verlustmodul (1)
- Vernetzung (1)
- Verzug (1)
- Viscoelastic (1)
- Vulkameter (1)
- tan delta (1)
Eingeladener Vortrag
- nein (29)
"Sehende" Nachtemperung: Praktische Anwendung der Methode der Dynamisch Mechanischen Analyse (DMA)
(2005)
A new method for the evaluation of the low temperature properties of rubber materials is presented. The method emulates the standardized compression set measurement, which is frequently used for sealing materials, but can be performed within a considerably shorter time. The results are compared with the standard test and found to be qualitatively the same. Slight differences are discussed on the basis of the differences in the measurement procedures. Further data evaluation is done by fitting functions to describe the material behaviour.
Partial discharges may cause damage to electrical insulation of high voltage equipment. They initiate elastic waves in the insulating material, e.g. in the stress cone of an outdoor termination. Localisation of the origin of such elastic waves can help to predict serious damaging processes in the electrical insulation. In order to measure and evaluate the wave propagation effects in typical multilayered elastomeric structures, knowledge of the material properties is required. The propagating velocity and the attenuation of longitudinal waves are important parameters. Values for these quantities found in the literature were not appropriate. Therefore, for cross-linked polyethylene (XLPE) and cured liquid silicone rubber (LSR), the longitudinal wave velocity and the attenuation were evaluated in the temperature interval from -20°C to 50°C and in the frequency range from 200 kHz to 600 kHz using a two-sample ultrasound technique. The loss factor was determined from these measured quantities. Additionally, low frequency Dynamic Mechanical Thermal Analysis (DMTA) was applied to investigate LSR and XLPE in a temperature interval between -100 and 50°C and to check qualitatively the ultrasound data.
Adhesion of amorphous polymers as a function of temperature probed with AFM force-distance curves
(2005)
Forcedisplacement curves have been obtained with a commercial atomic force microscope at different temperatures and probe rates on a thick film of poly(n-butyl methacrylate) and on two films of polystyrene with different molecular weight. In a previous publication [B. Cappella, S.K. Kaliappan, H. Sturm, Macromolecules 38 (2005)1874] the analysis of forcedisplacement curves has been focused on the stiffness and on the Young's modulus of the samples. In the present publication we consider the temperature dependence of the work of adhesion. We have obtained master curves of the work of adhesion at fixed maximum loads and, by comparing the results of the two analysis, we show that the work of adhesion follows the WilliamsLandelFerry equation with the same coefficients previously found for the Young's modulus. Furthermore, we show that the temperature dependence of the work of adhesion of the polymers is a consequence of the temperature dependence of the tipsample contact area and in the end of the temperature dependence of the stiffness and of the elasticplastic properties of the samples.
The investigation of low temperature properties of elastomeric sealing materials by means of thermo-analytical methods is a sound way to get information about the glass transition process.
The breakdown temperature of the sealing function of O-ring seals was measured in a component test setup depending on material and degree of compression.
An in depth explanation of the observed component tests behaviour is currently in preparation. It requires the results of thermo-analytical methods and measurements as the compression set (not shown here). With that, a model was developed to describe the correlation between physical material parameters and observed component behaviour.
Ferroelektrete sind zelluläre polarisierte Polymere, die ferroelektrische und dadurch auch piezoelektrische Eigenschaften aufweisen. Unter anderem werden sie für den Bau von Mikrofonen und Ultraschallwandlern für Materialprüfung eingesetzt. Dabei erweist sich ihre besonders niedrige akustische Impedanz als Vorteil. Ursache dafür ist vor allem ihr außergewöhnlich niedriger Elastizitätsmodul in Dickenrichtung. In diesem Beitrag werden zwei Methoden für die Ermittlung des Elastizitätsmoduls des geladenen zellulären Polypropylens (zPP) dargestellt. Die erste ist eine neuartige modellgestützte Methode mittels Laservibrometrie an dem eigenentwickelten Polypropylen-Wandler, wobei die Resonanzschwingung des Wandlers bei 250 kHz gemessen wird.
Die zweite Methode ist dynamisch-mechanische Analyse (DMA) durchgeführt mit Frequenzen von 0,3 bis 50 Hz, erstmalig für das zPP angewendet.
Carbon fibre prepregs have found widespread application in lightweight constructions. They are based on a carbon-fibre fabric impregnated with reactive epoxy resin. DMA measurements under temperature conditions similar to an autoclave programme were carried out using commercially available prepreg material with a high glass transition temperature. The characteristic of the temperature programme was a dynamic heating segment at 1.5 K/min followed by a longer isothermal segment at 180 °C. The courses of the storage modulus E', loss modulus E'' and tanδ were recorded. The measuring frequency was varied between 1 Hz and 33.3 Hz. Gelation and vitrification are assigned. The influence of the measuring frequency on the time to vitrification and the correlation with DSC are discussed. The reaction does not end even after 10 h curing at 180 °C, which is interpreted as the slow cessation of the reaction caused by vitrification.