Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (26) (entfernen)
Schlagworte
- DMA (3)
- Ultrasound (3)
- Dichtungen (2)
- Elastomere (2)
- High pressure DSC (2)
- Phenolic resin (2)
- Post curing (2)
- Reaction kinetic (2)
- Tieftemperaturverhalten (2)
- Compositbauteil (1)
- Compression set (1)
- Cure monitoring (1)
- Dichtung (1)
- Dielectric relaxation (1)
- Differential Scanning Calorimetry (1)
- Druckverformungsrest (1)
- Dynamic Mechanical Analysis (1)
- Dynamic mechanical analysis (1)
- Elastomer (1)
- Elastomers (1)
- Epoxidharz (1)
- Epoxy (1)
- Epxidharz (1)
- Ferroelectric polymer (1)
- Glasübergang (1)
- High temperature (1)
- Incoming goods inspection (1)
- Leakage rate (1)
- Lineare Aufheizung (1)
- Low temperature (1)
- Modulus (1)
- Moulding compound (1)
- Online Prozesskontrolle (1)
- P(VDF-HFP) (1)
- Poly(vinylidene(fluoride - hexafluoropropylene) (1)
- Prepreg (1)
- Process optimization (1)
- Prozesskontrolle (1)
- Rheologie (1)
- Rubber seals (1)
- Thermoanalyse (1)
- Ultraschall (1)
- Uniaxial stretching (1)
- Urea rsin (1)
- Vernetzungsreaktion (1)
- Vulcanization (1)
- Vulkanisation (1)
- tan delta (1)
Das Fließ-Härtungs-Verhalten von Duroplastformmassen wird gegenwärtig nur
unvollständig durch empirische Größen beschrieben. Diese ungenauen und
unsicheren Angaben können zu Schwierigkeiten bei der optimalen Einstellung
der Fertigungsmaschinen des Verarbeiters führen. Insbesondere Veränderungen
der Formmasseeigenschaften während des Transportes und der Lagerung stören
die Produktion. Das vorgestellte Messverfahren mit Ultraschall-sensoren ermöglicht
die schnelle und vollständige Erfassung des Fließ-Härtungs-Verhaltens, auch
während des technologischen Prozesses. Experimentelle Ergebnisse zu
Alterungs-erscheinungen dieser Formmassen illustrieren den Nutzen des
Verfahrens für Formmasse-produzenten und -verarbeiter.
The temperature dependences of dielectric permittivity and elastic modulus of poly(vinylidene fluoride - hexafluoropropylene) (P(VDF-HFP)) are compared and explained by use of structural data obtained by differential scanning calorimetry and X-ray analysis. Special emphasis is put on the effect of uniaxial stretching which renders the polymer ferroelectric. It is shown that dielectric and mechanical relaxations at the glass transition (aa relaxation) are closely related and not significantly affected by stretching. It is further confirmed that stretching destroys the non-polar spherulitic crystalline structure and produces relatively small-sized polar crystallites. This manifests in the disappearence of the so-called ac relaxation which is associated to molecular motions within the spherulitic crystalline lamellae. However, there are discrepancies between dielectric and mechanical losses above the glass transition which point towards a still not described structural transition.
Ferroelektrete sind zelluläre polarisierte Polymere, die ferroelektrische und dadurch auch piezoelektrische Eigenschaften aufweisen. Unter anderem werden sie für den Bau von Mikrofonen und Ultraschallwandlern für Materialprüfung eingesetzt. Dabei erweist sich ihre besonders niedrige akustische Impedanz als Vorteil. Ursache dafür ist vor allem ihr außergewöhnlich niedriger Elastizitätsmodul in Dickenrichtung. In diesem Beitrag werden zwei Methoden für die Ermittlung des Elastizitätsmoduls des geladenen zellulären Polypropylens (zPP) dargestellt. Die erste ist eine neuartige modellgestützte Methode mittels Laservibrometrie an dem eigenentwickelten Polypropylen-Wandler, wobei die Resonanzschwingung des Wandlers bei 250 kHz gemessen wird.
Die zweite Methode ist dynamisch-mechanische Analyse (DMA) durchgeführt mit Frequenzen von 0,3 bis 50 Hz, erstmalig für das zPP angewendet.
Rubbers are often used for seal applications due to their special material properties and easy use. In many applications the material is exposed to low temperatures during Operation. Therefore it is important to know the material behavior at low temperatures to determine the temperature ränge that allows a Safe Operation of the seal, e.g. in storage and transport Containers for radioactive materials.
The seal function of an elastomer is limited in temperature by the rubber-glass transition during which the material properties change from rubber-like to stiff and glass-like. For a given application this correlation is not trivial and therefore needs an in-depth investigation under consideration of the physical properties and the
application conditions.
In this work different analytical methods are used to characterize the material behavior at low temperature in the ränge of the glass-rubber-transition and are compared with the quality of Operation of a component which is here defined by the detected leakage rate.
Für Elastomenwerkstoffe im Allgemeinen und im Bereich der Dichtungstechnik im Besonderen ist der Druckverformungsrest eine wichtige Kenngröße zur Beurteilung der Eignung eines Werkstoffs bzw. der Funktion eines Bauteils. Er ermöglicht eine Einschätzung des zeitabhängigen Rückstellverhaltens eines Werkstoffs nach Deformation. Dieses ist für Dichtungen von besonderer Bedeutung, da der Test deren Einbauzustand nachstellt.
Oft wird er, bei der Prüfung unter erhöhten Temperaturen, zur Beurteilung des Alterungsverhaltens verwendet und kann anhand eines definierten Versagenskriteriums zur Lebensdauerabschätzung eingesetzt werden. Bei tiefen Temperaturen dient er dazu, die limitierende Einsatztemperatur zu bestimmen. Dabei spielt eine Alterung im eigentlichen Sinne nur eine untergeordnete Rolle, wohl aber physikalische Effekte wie Tieftemperaturkristallisation und Glasübergang. Diese Effekte sind weit weniger durch lange Lagerzeiten beeinflusst als die eigentliche Alterung.
Die Versuchsdurchführung unterscheidet sich je nach angewandter Norm und kann einen deutlichen Einfluss auf den Druckverformungsrest haben. Alle standardisierten Methoden sind aufgrund der langen Lagerzeiten relativ langwierig und erfordern das regelmäßige Eingreifen durch den Prüfer. Zusätzlich sehen einige Methoden nur die Bestimmung eines einzelnen Wertes nach einer definierten Zeit vor.
Um die Messungen zu beschleunigen wurde eine Methode entwickelt, die automatisch die erforderlichen Messungen bei mehreren Temperaturen durchführt.
Dazu wird ein Prüfgerät der Dynamisch Mechanischen Analyse verwendet, das kontinuierlich die Deformation während eines frei programmierbaren Temperaturzyklus misst, wodurch eine sehr große Datenmenge verfügbar ist.
Ein Vergleich der neuen Methode mit den Ergebnissen des nach ISO 815 genormten Messprinzips ergibt eine gute Übereinstimmung. Ergebnisse der neuen Methode werden vorgestellt und die Vorzüge der kontinuierlichen Datenerfassung, z.B. für die Materialauswahl, diskutiert.
Die vorgestellten Ergebnisse beziehen sich zum großen Teil auf die in beschriebenen Untersuchungen und Ergebnisse.