Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (29)
- Posterpräsentation (27)
- Beitrag zu einem Tagungsband (25)
- Zeitschriftenartikel (20)
- Beitrag zu einem Sammelband (16)
- Buchkapitel (1)
Referierte Publikation
- nein (118) (entfernen)
Schlagworte
- DMA (5)
- Elastomere (5)
- Prozesskontrolle (5)
- Ultraschall (5)
- Dichtungen (4)
- Elastomer (4)
- Tieftemperaturverhalten (4)
- Ultrasound (4)
- Vulkanisation (4)
- Dichtung (3)
- Druckverformungsrest (3)
- Dynamic mechanical analysis (3)
- Phenolharz (3)
- Aushärtegrad (2)
- Bakelit (2)
- DSC (2)
- Epoxidharz (2)
- Epoxy (2)
- Glasübergang (2)
- Gütesicherung (2)
- High pressure DSC (2)
- Kochversuch (2)
- Phenolic resin (2)
- Post curing (2)
- Prepreg (2)
- RTM (2)
- Reaction kinetic (2)
- Schallgeschwindigkeit (2)
- Sound velocity (2)
- Vernetzungsreaktion (2)
- Aminoharz (1)
- Aushärtung (1)
- Aushärtungsverlauf (1)
- Autoclave (1)
- Compositbauteil (1)
- Compression set (1)
- Cure monitoring (1)
- Curing (1)
- Curing behaviour (1)
- Curing degree (1)
- Dielectric relaxation (1)
- Dielektrik (1)
- Differential Scanning Calorimetry (1)
- Differential scanning calorimetry (1)
- Dynamic Mechanical Analysis (1)
- EVA (1)
- Elektroinstallationsteile (1)
- Epxidharz (1)
- Ferroelectric polymer (1)
- Fertigungskontrolle (1)
- Gelation (1)
- Glass transition (1)
- Harnstoffformasse (1)
- Harnstoffharz (1)
- Harnstoffharze (1)
- Harzinjektionsverfahren (1)
- High temperature (1)
- Incoming goods inspection (1)
- Injection moulding (1)
- Isolierstoff (1)
- Kautschuk (1)
- Kinetic (1)
- Klebfolie (1)
- Kunstharze (1)
- Lineare Aufheizung (1)
- Low temperature behaviour (1)
- Materialprüfungsamt (1)
- Modulus (1)
- Mould (1)
- Mould wall coupling (1)
- Moulding compound (1)
- O-Ring (1)
- On-line monitoring (1)
- Online Prozesskontrolle (1)
- P(VDF-HFP) (1)
- Photovoltaik (1)
- Poly(vinylidene(fluoride - hexafluoropropylene) (1)
- Process optimization (1)
- Prüfung (1)
- Qualitätssicherung (1)
- Resin transfer moulding (1)
- Rheologie (1)
- Rheology (1)
- Rtm (1)
- Schallgeschwindgkeit (1)
- Schrumpf (1)
- Sealing material (1)
- Sensors (1)
- Sound damping (1)
- Spritzgießen (1)
- Technische Vereinigung (1)
- Thermoanalyse (1)
- Thermoset (1)
- Thermoset manufacturing (1)
- Ultrasonic (1)
- Ultrasound sensors (1)
- Uniaxial stretching (1)
- Urea rsin (1)
- Vernetzung (1)
- Verzug (1)
- Vitrification (1)
- Vulcanisation (1)
- Vulcanization (1)
- Vulkameter (1)
- tan delta (1)
Eingeladener Vortrag
- nein (29)
"Sehende" Nachtemperung: Praktische Anwendung der Methode der Dynamisch Mechanischen Analyse (DMA)
(2005)
The investigation of low temperature properties of elastomeric sealing materials by means of thermo-analytical methods is a sound way to get information about the glass transition process.
The breakdown temperature of the sealing function of O-ring seals was measured in a component test setup depending on material and degree of compression.
An in depth explanation of the observed component tests behaviour is currently in preparation. It requires the results of thermo-analytical methods and measurements as the compression set (not shown here). With that, a model was developed to describe the correlation between physical material parameters and observed component behaviour.
Ferroelektrete sind zelluläre polarisierte Polymere, die ferroelektrische und dadurch auch piezoelektrische Eigenschaften aufweisen. Unter anderem werden sie für den Bau von Mikrofonen und Ultraschallwandlern für Materialprüfung eingesetzt. Dabei erweist sich ihre besonders niedrige akustische Impedanz als Vorteil. Ursache dafür ist vor allem ihr außergewöhnlich niedriger Elastizitätsmodul in Dickenrichtung. In diesem Beitrag werden zwei Methoden für die Ermittlung des Elastizitätsmoduls des geladenen zellulären Polypropylens (zPP) dargestellt. Die erste ist eine neuartige modellgestützte Methode mittels Laservibrometrie an dem eigenentwickelten Polypropylen-Wandler, wobei die Resonanzschwingung des Wandlers bei 250 kHz gemessen wird.
Die zweite Methode ist dynamisch-mechanische Analyse (DMA) durchgeführt mit Frequenzen von 0,3 bis 50 Hz, erstmalig für das zPP angewendet.