Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (52)
- Vortrag (46)
- Forschungsbericht (17)
- Beitrag zu einem Sammelband (10)
- Posterpräsentation (9)
- Zeitschriftenartikel (8)
Sprache
- Englisch (73)
- Deutsch (68)
- Mehrsprachig (1)
Referierte Publikation
- nein (142) (entfernen)
Schlagworte
- VOC (34)
- Bauprodukte (25)
- Geruch (24)
- Emissionen (18)
- Emission test chamber (15)
- BEMMA (10)
- Odour (9)
- Round robin test (9)
- SVOC (9)
- Emission (8)
- AgBB-Scheme (6)
- Museum (6)
- VOC emission (6)
- VOC-emission (6)
- Blauer Engel (5)
- Chamber test (5)
- Emissions (5)
- Interlaboratory study (5)
- Kammermessungen (5)
- Perceived intensity (5)
- Reference material (5)
- AbBB-Schema (4)
- AgBB (4)
- AgBB-Schema (4)
- Building products (4)
- Construction product (4)
- Emissionskammer (4)
- Ringversuch (4)
- Volatile organic compounds (4)
- Building material (3)
- Emissionsmesskammern (3)
- Emissionsmessungen (3)
- GC/MS (3)
- Geruchsmessung (3)
- ISO 16000-6 (3)
- Odour evaluation (3)
- Perceived air quality (3)
- QA/QC (3)
- Thermal desorption (3)
- VOC-Emission (3)
- VOC-Emissionen (3)
- VOCs (3)
- VVOC (3)
- Vitrinen (3)
- Acceptability (2)
- Air sampling (2)
- Bauprodukt (2)
- Bewertung (2)
- Bewertung Emissionen (2)
- Biocide (2)
- Biocides (2)
- Blue Angel (2)
- Bürogeräte (2)
- CO2 assisted impregnation (2)
- Chamber tests (2)
- Construction products (2)
- Copiers (2)
- Display case (2)
- Dust (2)
- Emission tests (2)
- Emissionsmessung (2)
- Empfundene Intensität (2)
- External quality management system (2)
- GC-ODP (2)
- Gas mixing device (2)
- Geruchstest (2)
- Harmonisation (2)
- Hedonik (2)
- Indoor air (2)
- Kammerverfahren (2)
- Labelsysteme (2)
- Laborvergleich (2)
- Laserdrucker (2)
- Material emission (2)
- Messmethoden (2)
- Normung (2)
- Odour standard of comparison (2)
- Ozone (2)
- Partikelemissionen (2)
- Perceived Intensity (2)
- Perceived odour intensity (2)
- Printers (2)
- Product emission testing (2)
- Präventive Konservierung (2)
- Referenzmaterial (2)
- Standardisation (2)
- Tenax thermal desorption (2)
- VOC Emissionen (2)
- VOC analysis (2)
- Acetic and formic acid (1)
- Acrylic and silicone sealant (1)
- Adsorptive wall material (1)
- AgBB Bewertung (1)
- AgBB scheme (1)
- AgBB-scheme (1)
- Assessment of emissions from materials for museum equipment (1)
- Assessment procedure (1)
- Ausstellungsvitrinen (1)
- BEMMA Bewertung (1)
- BEMMA display case (1)
- Bewertungsverfahren (1)
- Bodenbelag (1)
- Bodenbeläge (1)
- Building materials (1)
- Building product (1)
- Bürogeräte mit Druckfunktion (1)
- Bürogeräte mit Laserdruckfunktion (1)
- Capsules (1)
- Carbograph 5TD (1)
- Carbopack X (1)
- Chamber copmparison (1)
- Chamber study (1)
- Chamber-test (1)
- Chemische Emissionen (1)
- Climate control device (1)
- Conductivity (1)
- Construction products directive (1)
- Consumer products (1)
- Coverings (1)
- Detection of formic and acetic acid (1)
- Directive (1)
- Dispay case (1)
- Display cases (1)
- Drucker (1)
- Dämmstoffe (1)
- EN-Standards (1)
- Emission reference material (1)
- Emission test (1)
- Emission testing (1)
- Emissions testing (1)
- Emissionsarme Vitrine (1)
- Emissionsarme Vitrinen (1)
- Emissionsmesskammer (1)
- Environmental label (1)
- Environmental sign (1)
- Evaluation (1)
- Evaluation system (1)
- FEM model (1)
- Fatty acid (1)
- Feine und ultrafeine Partikel (1)
- Floor coverings (1)
- Flooring material (1)
- Flüchtige Emission (1)
- Framework (1)
- Gas atmosphere (1)
- Gas sensor (1)
- Geruchsmessungen (1)
- Hardcopy device (1)
- Hardcopygerät (1)
- Health assessment (1)
- Health care (1)
- Hedonic (1)
- Hedonic tone (1)
- Hexanal (1)
- Hydrocarbon (1)
- Indoor material emissions (1)
- Innenraum (1)
- Innenraumluftqualtität (1)
- Insulation material (1)
- Inter laboratory study (1)
- Interlaboratory comparison (1)
- Kohlenwasserstoff (1)
- Kopierer (1)
- Label (1)
- Labeling (1)
- Labelling (1)
- Labelling scheme (1)
- Labelling schemes (1)
- Labelling systems (1)
- Laboratory studies (1)
- Lacquers (1)
- Low VOC concentrations (1)
- Material emissions (1)
- Material labelling (1)
- Measurements (1)
- Micro-chamber (1)
- Microbiological contamination (1)
- Museumsvitrine (1)
- Museumsvitrinen (1)
- OSB (1)
- Odor (1)
- Odour assessment (1)
- Odour intensity (1)
- Odour labelling (1)
- Odour measurement (1)
- Olfactory detection port (1)
- Organic acids (1)
- Oxidation products (1)
- Ozon (1)
- Paints (1)
- Partikelemission (1)
- Perceived Air Quality (1)
- Perceived air-quality (1)
- Poficiency test (1)
- Pollutant (1)
- Polymer (1)
- Polymeric material (1)
- Polyurethane foam (1)
- Probenahmebehälter (1)
- Product certification (1)
- Product labelling (1)
- Produkttypischer Geruch (1)
- Proficiency Test (1)
- Proficiency testing (1)
- Profiling (1)
- Protection of cultural object (1)
- Prüfverfahren (1)
- Quality assurance (1)
- Quality control (1)
- Quantification of formic and acetic acid (1)
- RAL UZ (1)
- RAL-UZ 122 (1)
- Reasonability (1)
- Reference materials (1)
- Reference odour (1)
- Round robin (1)
- SDVB-polymer (1)
- Saturated and unsaturated aldehyde (1)
- Schadstoff (1)
- Schadstoffe (1)
- Semi volatile organic compounds (1)
- Sensor system (1)
- Sensor systems (1)
- Sensorik (1)
- Sensorsystem (1)
- Sensory evaluation (1)
- Sensory tests (1)
- Sorption flux (1)
- Sources/emissions (1)
- Standardization (1)
- Staub (1)
- Test method (1)
- Test method validation (1)
- Test procedure (1)
- Testing method (1)
- Testing using sensors (1)
- Thermal extraction (1)
- Umweltzeichen (1)
- VOC emissions (1)
- Verpackungsmaterialien (1)
- Very volatile organic compounds (1)
- Vitrine (1)
- Volatile emission (1)
- Volatile organic compound (1)
- Wood (1)
- Wood-based product (1)
- sensory evaluation of building materials and rooms (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (46)
Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt.
Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes.
Anregungen aus dem N.i.Ke.-Workshop 2017 und künftige Anforderungen. BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Hier wird der Status-Quo des Erreichten dargestellt. Wie wird das Schema in der Museumsöffentlichkeit wahrgenommen und seine Akzeptanz.