Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (35) (entfernen)
Schlagworte
- VOC (12)
- Bauprodukte (8)
- Emission test chamber (6)
- SVOC (6)
- Emissionen (5)
- Geruch (4)
- Reference material (4)
- BEMMA (3)
- Indoor air (3)
- Micro-chamber (3)
Organisationseinheit der BAM
Since semi-volatile organic compounds (SVOCs), including biocides and polychlorinated biphenyls (PCBs), occur indoors as well as outdoors, air sampling adsorbents and measuring methods for all these compounds are indispensable. This paper presents the initial steps in the development of such a method, the aim of which is the analysis of selected compounds in the above-mentioned classes using low air sampling volumes and air-exchange rates close to zero, as is common in museum showcases. For measurements under easily controlled conditions, a micro-chamber system was used at different temperatures. A surface modified styrene divinylbenzene (SDVB) polymer was selected as the air sampling adsorbent for the elution experiments. After successfully performing pretests using the micro-chamber system with target compound solutions, the emissions of these compounds from self-soaked wood samples and con-taminated wood samples were investigated for method development.
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail.
Cellulose ethers, like methyl cellulose (MC) or hydroxypropyl cellulose (HPC), are widely used in conservation. They also occur as additives and rheology modifiers in various products like dispersions or gels. Do such products release harmful volatile organic compounds (VOC) during their accelerated aging? A mass testing series utilizing the Oddy test of 60 commercial cellulose ethers ranks the products in safe for permanent use (P, no corrosion), only for temporary use (T, slight corrosion), and unsuitable at all (F, heavy corrosion). Results show that 55% of the products passed the test whereas 33% are for temporary use as slight corrosion occurred on at least one metal coupon and only 11% failed the Oddy test. Raman measurements of the corrosion products identified oxides like massicot, litharge, cuprite, and tenorite among carbonates (hydrocerussite, plumbonacrite), and acetates like basic lead acetate, lead acetate trihydrate as well as lead formate as main phases. For example, commercial, industrial Klucel® G (HPC) scored a T rating through slight corrosion on the lead coupon. Basic lead acetate among other phases indicates the presence of acetic acid. Additional measurements of the sample with thermal desorption GC–MS utilizing the BEMMA scheme confirm the high acetic acid outgassing and reveal the presence of a small amount of formaldehyde.
Ausstellungskuratoren, Restauratoren oder Fachplaner stehen immer wieder vor der Entscheidung, geeignete Materialien für Museumsausstattungen auswählen zu müssen. Vitrinen, Depoteinrichtungen, aber auch Transportverpackungen für Kunst- und Kulturgut sollten unbedingt frei von Schadstoffen sein. Ein neues Verfahren ermöglicht nun eine problemorientierte Untersuchung und Bewertung von Materialien mit belastbaren und reproduzierbaren Ergebnissen.
Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography mass spectrometry/mass spectrometry).
Volatile organic compounds (VOCs) found indoors have the potential to affect human health. Typical sources include building materials, furnishings, cleaning agents, etc. To address this risk, chemical emission testing is used to assess the potential of different materials to pollute indoor air. One objective of the European Joint Research Project 'MACPoll' (Metrology for Chemical Pollutants in Air) aims at developing and testing a reference material for the quality control of the emission testing procedure. Furthermore, it would enable comparison of measurement results between test laboratories. The heterogeneity of the majority of materials makes it difficult to find a suitable reference sample.
In the present study, styrene, 2-ethyl-1-hexanol, N-methyl-α-pyrrolidone, lindane, n-hexadecane, 1,2-dimethyl- and 1,2-di-n-butyl-phthalate were added to 12 commercially available lacquers (6 alkyd and 6 acrylic polymer based lacquers) serving as carrier substrate. After homogenization, the mixtures were loaded into a Markes Micro-Chamber/Thermal Extractor (µ-CTE) for curing and investigation of the emission behavior for each compound. For almost all of the investigated chemicals, the preferred glossy acrylic lacquer showed emissions that were reproducible with a variation of less than 20% RSD. Such lacquer systems have therefore been shown to be good candidates for use as reference materials in inter-laboratory studies.
Development of a multi-VOC reference material for quality assurance in materials emission testing
(2015)
Emission test chamber measurement is necessary to proof building materials as sources of volatile organic compounds (VOCs). The results of such measurements are used to evaluate materials and label them according to their potential to emit harmful substances, polluting indoor air. If only labelled materials were installed indoors, this would improve indoor air quality and prevent negative impacts on human health. Because of the complex testing procedure, reference materials for the quality assurance are mandatory. Currently, there is a lack of such materials because most building products show a broad variation of emissions even within one batch. A previous study indicates lacquers, mixed with volatile organic pollutants, as reproducible emission source for a wide range of substances. In the present study, the curing of the lacquer-VOC mixture inside micro-chambers was optimised. Therefore, the humidity and the chamber flow were varied. Typical indoor air pollutants with a wide range of volatilities, for example, styrene, n-hexadecane, dimethyl and dibutyl phthalate were selected. It turned out that, under optimised curing parameters inside the micro-chamber, their emission can be reproduced with variations of less than 10 %. With this, a next important step towards a reference material for emission testing was achieved.
Background to the studies was the revision of the current selection criteria of the German ecolabel Blauer Engel (Blue angel) for copiers and printers. In the requirements limits were set for ozone, dust and styrene emissions. The former test methods did no longer correspond to todays requirements with regard to emission measurements. In addition, the emission behaviour of hardcopy devices due to the use of different and non-com parable test methods has been recently discussed controversely. For this reason a new test method had to be developed which enables a reliable, reproducible determination of emission rates (ER) for dust, ozone and VOC (volatile organic compounds). The basis for this was the ECMA-Standard 328 compiled by ECMA (European Computer Manufacturer Association) using dynamic chamber measurements. Nine different machines, desktop laser printers as well as office devices like bigger copiers and multifunctional devices were investigated. As a result of the study new criteria for the Blauer Engel for copiers, printers and a new created for multifunctional devices, concerning TVOC, ozone and dust emission were determined. Additionally a model is presented calculating the concentrations in real rooms under usual printing conditions derived from the test chamber results.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Methods for the determination of biocide emissions from treated materials into water and air were developed and tested in order to support a comparative ecological assessment of biocidal products. Leaching tests, experiments with simulated rain, extraction cleaning of carpets and emission chamber tests were performed with a series of treated materials. The experiments focused on the effect of changes in the procedure as well as characteristics of the specimens and demonstrate the suitability of the proposed methods for biocides of different product types.
It was demonstrated that emissions of biocides into water can be compared on the basis of leaching tests in which the emission kinetics of the active ingredients are recorded. However, the water volume per surface area and the timetable for water changes have to be defined in such tests. Functions of flux rates related to time can be well described for inorganic compounds, whereas modelling of the data is more complicated for organic substances.
Emission chamber tests using 20-litre and 23-litre glass exsiccators, originally developed to study volatile organic compounds, were successfully adapted for the investigation of the emission of biocides from treated materials which are usually semi volatile organic compounds. However, test parameters and the method of analysis have to be adapted to the substances to be determined.
Generally, it was found that the emission curves for the semi volatile organic compounds investigated differ from those of volatile organic compounds.