Correlation of aldehyde emissions and fatty acids content in pine wood and oriented strand boards
(2011)
Indoor air quality is important for human health and comfort. To ensure good indoor air quality contamination by volatile organic compounds (VOC) should be minimised. The aim of the project is the reduction of unsaturated aldehydes which can emit from oriented Strand boards (OSB): These aldehydes have an impact on the health based evaluation of emissions from products for indoor use according to the AgBB (Ausschuss zur gesundheitlichen Bewertung von Bauprodukten, Committee for Health Evaluation of Building Products) scheine (AgBB 2010). The model OSB were produced in a pilot plant using well known raw materials (Pinus sylvestris at different trunk heights) under using various processing parameters (Wilke et al. 2011).
OSB emit predominantly monoterpenes and aldehydes. Aldehydes are oxidation products of fatty acids in wood. The conditions which affect the oxidation process are the fatty acid concentration and composition, the oxygen content, the sample surface and the presence of compounds which indicate, inhibit or stop the oxidation respectively. The oxidation rate rises with an increasing number of double bounds in the fatty acid, e.g. the oxidation rate between oleic, linoleic and linolenic acid correspond to 1:12:24. One of the most important products of fatty acid oxidation is hexanal. It is generated during the oxidation of linoleic acid. This study shows a direct correlation between aldehyde emission and oxidation, hexanal can be used as an indicator for oxidation.
Indoor air pollutants influence the health and comfort of building occupants and consequently the energy consumption of the building. The pollutants are emitted by various sources.
Among these sources, building products are of particular importance. To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany also mandatory “Principles for the health assessment of construction products used in interiors” have been applied for the technical approval of floor coverings since 2004. This procedure is based on the assessment scheine of the Committee for Health-related
Evaluation of Building Products (AgBBScheme). The sensory-limit settings for building-material label Blue Angel offer consumer to differ not only low-emission but also low-odour Building materials from another building materials.
Product emissions chamber testing involves a complex protocol with several sources of measurement uncertainty (ASTM, 2010; ISO, 2006). Despite the potential for significant variability in measurement results within and among laboratories, there is no Standard method available to assess the accuracy of emissions chamber test results. Recently, Germany’s Federal Institute for Materials Research and Testing (BAM) started a program to evaluate the performance of laboratories testing for the AgBB (German Committee for Health-related Evaluation of Building Products) labelling scheme (Wilke et al., 2009). Test method validation was conducted through interlaboratory studies (ILS) with over 30 participants. Simultaneously, the National Institute of Standards and Technology (NIST) and Virginia Tech (VT) started a program to develop a series of reference materials that mimic real building products, can be tested in typical emissions chambers, and have independently known emission rates (Cox et al., 2010). BAM, NIST and VT subsequently joined forces to conduct a series of inter-laboratory studies using the prototype reference material. A pilot ILS was conducted with BAM and NIST followed by an expanded ILS with several participating countries. Results from these interlaboratory studies have the potential to define an internationally-accepted Standard approach to validate results from product emissions tests.
Besides measurement of VOC emissions also the evaluation of odour emissions and the perceived intensity of odours gains in importance. Due to difficulties detected in the measurement method of the perceived intensity described in (ISO 16000-28, 2012) the introduction of “reference” odours will be recommended for the training of panellists and as basis for interlaboratory comparisons.
In order to generate the “reference” odours standard liquid substances were directly injected into the main gas flow provided to the panellists. One of the substances tested was ethyl acetate. A pre-evaluation was conducted with six untrained panellists and has shown that ethyl acetate is potentially suitable as reference odour. For further validation of those “reference” odours they additionally will be provided to and evaluated by trained panellists of well established-measurement institutes.
Um eine gute Luftqualität in Gebäuden zu erreichen, müssen Reinigungslasten durch Lüften aus Räumen abgeführt bzw. vermieden oder verringert werden. Wird der Luftwechsel verringert, verschlechtert sich die Raumluftqualität, und die Zufriedenheit der Nutzer nimmt ab. An Arbeitsplätzen kann es bei schlechter Luftqualität und der daraus resultierenden Unzufriedenheit zu einer geringeren Produktivität der Beschäftigten kommen. Um die Reinigungslasten und deren Wirkung auf den Raumnutzer überdas Geruchsempfinden zu verringern, ist neben einer messtechnischen Erfassung der Verunreinigungen auch eine sensorische Prüfung in Innenräumen und von Bauprodukten notwendig. In diesem Artikel wird die Entwicklung der Bewertungsmethodik von Gerüchen im Innenraum erläutert und auf Anwendungen eingegangen.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap 300 (R) (a multi-bed tube using Carbopack C (R), Carbopack B (R) and Carbosive SIII (R)) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber.
Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren.
Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden.
Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden. Diese Entwicklungen werden hier aufgezeigt.
Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat.
Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits-anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor.
Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012.
Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically, air exchange rates are often smaller than 0.1 d-1, which can result in rising concentrations of potential harmful VOC inside of the display cases due to emissions from materials. Especially organic acids, e. g. formic or acetic acid which can emit from e.g. sealing materials or wood-based materials, can produce damage of cultural objects.
In 2012 BAM introduced a procedure which is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museums¬ausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Regarding the testing procedure only construction materials were evaluated, not the display cases their self. Micro chambers are used for VOC emission tests of display case construction materials, e.g. plastics, sealing materials, coatings, textiles and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde, piperidine-derivates and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme.
Mit dem BEMMA-Verfahren lassen sich flüchtige organische Verbindungen aus modernen Werkstoffen, die in mittel- oder unmittelbarem Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen, untersuchen und bewerten. Das Verfahren wurde im Rahmen eines AIF-Vorhabens und der Untersuchung von über 100 unterschiedlichen Materialien entwickelt. Weiterhin wurden mit den gewonnenen Ergebnissen und einigen zuvor bereits identifizierten Problemstoffen wie Essigsäure, Formaldehyd oder Oxime aus den Vorhabenerkenntnissen Bewertungskriterien erarbeitet. Die Vitrinenbaumaterialien, nicht die Vitrine, werden im Hinblick auf ihre Emissionen bewertet, wobei z. B. Holzwerkstoffe nicht bewertet werden, zumal diese meist mit Formaldehyd ein Emissionsproblem hätten. Der Einsatz von Materialien für Vitrinen, die gemäß BEMMA-Schema getestet wurden und die die Emissionswerte erfüllen, soll die Herstellung möglichst emissionsarmer Vitrinen ermöglichen. Kernstück des BEMMA-Schemas ist die Bewertung aller Messergebnisse gemäß dem im Folgenden dargestellten Untersuchungsablauf:
1. Beladen der µ-Kammer; 2. Probenahme der flüchtigen, kurzkettigen, organischen Säuren (ca. 0,5 bis 1 Stunde nach der Beladung für ca. 20 Stunden, 30 Liter Probenahmevolumen); 3. Probenahme der VOCs mit Tenax® (ca. 10 Minuten, 0,25 Liter Probenahmevolumen); 4. Probenahme Oxime und Piperidin-Derivate† mit Tenax® (ca. 40 Minuten, 1,0 Liter Probenahmevolumen); 5. Probenahme der Aldehyde und Ketone (für ca. 20 Stunden, 30 Liter Probenahmevolumen) Dabei werden 4 Sammlersysteme beladen und anschließend analysiert.
Die mit dem BEMMA Schema entwickelten Summenwerte für flüchtige organische Stoffe sind im Wesentlichen vor dem Hintergrund der Emissionsminimierung aufgestellt worden. Es gibt für viele VOC keine eindeutige Wechselwirkung mit den Objekten in der Vitrine, zumal diese auch aus vielen verschiedenen Werkstoffen bestehen können und ein VOC nicht mit all diesen reagieren wird. Grundsätzlich „verdächtig“ sind natürlich alle reaktiven Stoffe, wie z. B. Isocyanate. Diese werden aber aus gut gelagerten oder ausreichend belüfteten Baumaterialien für Vitrinen nicht abgegeben. Anorganische Schadgase können zwar in der Umgebungsluft verstärkt auftreten - sind aber aus Baumaterialien nicht zu erwarten. Daher kann das BEMMA-Schema auch nur für einen Teil der luftgetragenen Schadstoffe eine sinnvolle Aussage treffen.
Eines der Probleme bei der Bewertung vieler Kleb-/Dichtstoffe ist die Emission cyclischer Siloxane. Deren Schädigungspotential einzu¬schätzen wäre eine wichtige Aufgabe, um an dieser Stelle mehr Klarheit bei der Bewertung zu bekommen.
Ein Ringversuch ist eine Methode der externen Qualitätssicherung für sowohl Messverfahren als auch die Eignung von Mess- und Prüflaboratorien. Dabei werden möglichst identische Proben mit identischen Verfahren oder mit unterschiedlichen Verfahren untersucht. Die Teilnahme an Ringversuchen ist für alle akkreditierten Laboratorien ein wesentlicher Baustein der institutsinternen und -externen Qualitätssicherung. Je mehr Faktoren Einfluss auf das Endergebnis haben können, desto wichtiger ist es diese Faktoren zu kennen und deren Einflüsse durch weitestgehende Vergleichbarkeit der Messverfahren zu minimieren.
Für die Bewertung von Emissionen aus Bauprodukten haben sich Emissionsmess-kammer-Untersuchungen als Messverfahren etabliert. Diese Methode an sich weist zahlreiche Faktoren auf, die das Untersuchungsergebnis beeinflussen können, als da wären die Konstanz der Parameter wie Luftwechselrate, Luftfeuchtigkeit und Temperatur oder die konkrete Präparation der Probe und deren Positionierung in der Kammer etc. Für die Probenahme von flüchtigen organischen Komponenten kommen noch die eher analytischen Faktoren dazu und für die geruchliche Bewertung lassen sich weitere Einflussgrößen identifizieren. Um den Geruch auch für Innenraumanwendungen bewertbar zu machen sind in den letzten Jahren erste Normen entstanden (z. B. DIN ISO 16000-28 und VDI 4302-1). Um die Eignung dieser Normen und deren Anwendung zu untersuchen sind seit 2012 nunmehr 3 Ringversuche der BAM auch zum Thema Geruch durchgeführt worden.
Die ersten beiden dieser Ringversuche wurden mit hohem zeitlichen und personellen Aufwand begleitet. So fuhren in 2012 Mitarbeiter der BAM zu den Teilnehmern und begutachteten vor Ort die jeweils vorhandenen Bewertungs-einrichtungen. In 2014 und 2016 wurden jeweils Materialien verschickt, die sowohl eine geruchliche Bewertung als auch für die Bestimmung von VOC in der Prüfkammerluft geeignet waren. Parallel zu den Proben wurden eine sehr konkrete Anweisung verschickt, wie der Ringversuch durchzuführen war und weiterhin sehr ausführliche Fragebögen, deren Ergebnisse z. T. in die Neufassung der ISO-Norm einfließen sollen.
Die bislang durchgeführten Ringversuche mit dem Ziel der Geruchsbewertung wiesen Standardabweichungen von ca. 24 bis 30 % um den jeweiligen Mittelwert auf und wiesen somit ähnliche Werte auf, die auch bei den VOC-Vergleichen ermittelt wurden.
Textile floor coverings are often used in offices and residential buildings. Large areas like meeting rooms, cinemas, theaters and hotels are often equipped with such coverings. They contribute to the comfort of the users as they provide high pedaling comfort and sound absorption. The weakness of these building materials is due to the odor emission that is released from the floor covering, which affects the comfort of the users. A bad air quality and the resulting dissatisfaction can lead to lower employee productivity. The research project of the Hochschule für Technik und Wirtschaft Berlin (HTW-Berlin) is promoted by the German Environment Agency (UBA). The project has the following title: Low-emission and low-odor building products for energy-efficient buildings - Development of requirements and concepts for the Blue Angel from a climate protection perspective; investigates the emission and odor behavior of textile floor coverings (Emissions- und geruchsarme Bauprodukte für energieeffiziente Gebäude - Entwicklung von Anforderungen und Konzepten für den Blauen Engel aus Klimaschutzsicht; untersucht das Emissions- und Geruchsverhalten textiler Bodenbeläge).
Moderne Vitrinen sollen gleichzeitig eine hohe Dichtigkeit und die Abwesenheit jeglicher Fremdstoffe in den Vitrinen gewährleisten. Diese Anforderungen sind zeitgleich kaum erfüllbar, da es emissionsfreie Materialien (vor allem Kleb- und Beschichtungsstoffe) nicht gibt. Um die potentiellen Emissionen zu minimieren wurde ein Messverfahren entwickelt, welches inzwischen als BEMMA-Schema (Bewertung von Emissionen aus Materialien für Museumsausstattungen) in die Museumswelt Einzug genommen hat.
Die erfolgreiche Bewertung der für den Bau verwendeten Materialien gemäß BEMMA-Schema resultiert nicht in einer emissionsfreien Vitrine, sondern soll bei der Auswahl geeigneter Materialien zur Herstellung möglichst emissionsarmer Vitrinen helfen. Konkrete handwerkliche Durchführungen beim Bau, Dichtheits¬anforderungen, wie auch die Aufstellbedingungen (Umgebung der Vitrine) beeinflussen die Emissionscharakteristik der fertigen Vitrine in der Praxis. Eine saubere Vitrine hilft nichts in einer belasteten Umgebung oder auch bei emittierenden Exponaten. Inzwischen liegen Erfahrungen mit dem Schema seit 2012 vor.
Der Messablauf sieht vor, dass von den Materialien kleine Muster mit der Mikrokammer (Markes) innerhalb von 2 Tagen untersucht werden. Dabei wird mit Silikagelkartuschen auf Ameisen- und Essigsäure, mit DNPH auf Aldehyde und Ketone und mit Tenax® sowohl auf VOC als auch für die spezifische Oxim-Analytik die Abluft der Mikrokammern untersucht. Die Bewertungskriterien basieren auf den Ergebnissen einer Vorstudie mit ca. 150 verschiedenen Produkten im Zeitraum 2010 bis 2012.
Museumsvitrinen sollen Kunst- und Kulturgut „ins rechte Licht“ setzen und vor Diebstahl oder Vandalismus schützen. Vergleicht man historische Schauvitrinen, die zumeist aus einfachen Glasscheiben in Holzrahmungen bestehen, mit heutigen Konstruktionen, lässt sich eine Entwicklung zu hochtechnisierten Gebilden ablesen, die deutlich mehr Ansprüchen genügen müssen als in der Vergangenheit.
Zahlreiche Beispiele verdeutlichen, dass Kunstwerke nicht nur außerhalb, sondern auch innerhalb von Museen oder Archiven ungünstigen Umwelteinflüssen ausgesetzt sind. So können Einbauten bzw. Dekorationen in Ausstellungsräumen, Aufbewahrungsbehältnisse in Depoträumen oder Ausstellungsvitrinen flüchtige Substanzen, sogenannte VOCs (Volatile Organic Compounds) freisetzen, die zu irreversiblen Veränderungen an den Objekten führen und diese schädigen. Hierzu zählen organische Säuren, wie Ameisen- oder Essigsäure, aber auch Verbindungen, die Sulfide enthalten. Hier wird die an der BAM entwickelte BEMMA-Bewertungsmethode vorgestellt, die von Museen verwendet werden kann Materialien mit einem geringeren Emissionspotential auszusuchen.
Quality Improvement of VOC chamber emission tests observed for 10 years with round robin tests
(2018)
In Europe, the Construction Products Regulation (CPR, 2011/305/EU) sets basic requirements (BR) on how construction works must be designed and built. BR 3 “hygiene, health and the environment” states low emissions of toxic gases, Volatile Organic Compounds (VOCVOCs), particles, etc. from building materials. Meanwhile, a worldwide network of professional Commercial and non-commercial laboratories performing emission tests for the evaluation of products for interior use has been established.
Therefore, comparability of test results must be ensured. The participation in Round Robin Tests (RRTRRTs) is a means to prove a laboratory’s proficiency. Since 2006 BAM offers such proficiency test for emission chamber test every two years.
Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found. BAM used different materials over the years. Currently, the best suited reference material is a cured lacquer surface which contained several VOCs added to the liquid lacquer system. The round robin tests 2014, 2016 and 2018 were conducted with such a system.
Compounds like Styrene or n-Alkanes like Decane or Tridecane were tested in many of the proficiency test operated by BAM. Up to now the relative standard deviation of these compounds decrease continuously. Starting with values about 30 % in 2008 we reached values for the mentioned compounds 15 to 20 % now. But even for more polar compounds improved results were received.
Over the years the results of a large group of laboratories detected many compounds with much higher accuracy than at the beginning. So, the comparability between results of different laboratories becomes much better.
Natural building materials for interior fitting and refurbishment - What about indoor emissions?
(2021)
Indoor air quality can be adversely affected by emissions from building materials, consequently having a negative impact on human health and well-being. In this study, more than 30 natural building materials (earth dry boards and plasters, bio-based insulation materials, and boards made of wood, flax, reed, straw, etc.) used for interior works were investigated as to their emissions of (semi-) volatile organic compounds ((S)VOC), formaldehyde, and radon. The study focused on the emissions from complete wall build-ups as they can be used for internal Partition walls and the internal insulation of external walls. Test chambers were designed, allowing the compounds to release only from the surface of the material facing indoors under testing Parameters that were chosen to simulate model room conditions. The emission test results were evaluated using the AgBB evaluation scheme, a procedure for the health-related evaluation of construction products and currently applied for the approval of specific groups of building materials in Germany.
Seventeen out of 19 sample build-ups tested in this study would have passed this scheme since they generally proved to be low-emitting and although the combined emissions of multiple materials were tested, 50% of the measurements could be terminated before half of the total testing time.
Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases.
Bauprodukte, die in Innenräumen verwendet werden, sollten die Gesundheit und das Wohlbefinden der Personen die sich darin aufhalten nicht durch das Ausdünsten von Geruchsstoffen stören. Die DIN ISO 16000-28 „Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ (DIN ISO 16000-28) beschreibt umfassend die Möglichkeiten der Geruchsprüfung. In Verbindung mit der Anwendung der VDI-Richtlinie 4302 Blatt 1 „Geruchsprüfung von Innenraumluft und Emissionen aus Innenraummaterialien“ (VDI 4302 Blatt 1) ist sie zur Bewertung der empfundenen Intensität von Bauprodukten mit Vergleichsmaßstab geeignet (Umweltbundesamt 2015). In einem vom Umweltbundesamt (UBA) geförderten Forschungsprojekt der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) und der Bundesanstalt für Materialforschung und –prüfung (BAM) wurden erstmals verschiedene Vergleichsmaßstäbe miteinander verglichen. Ziel des derzeitigen Folgeprojektes ist nun, Mindestanforderungen an Vergleichsmaßstäbe zu erarbeiten, welche die Reproduzierbarkeit der Ergebnisse erhöhen und mit denen die Norm konkretisiert werden kann. Dieser Beitrag stellt die Untersuchungen und Ergebnisse des ersten Projektes und die Schlussfolgerungen für die Durchführung des zweiten Projektes dar.
Cellulose ethers, like methyl cellulose (MC) or hydroxypropyl cellulose (HPC), are widely used in conservation. They also occur as additives and rheology modifiers in various products like dispersions or gels. Do such products release harmful volatile organic compounds (VOC) during their accelerated aging? A mass testing series utilizing the Oddy test of 60 commercial cellulose ethers ranks the products in safe for permanent use (P, no corrosion), only for temporary use (T, slight corrosion), and unsuitable at all (F, heavy corrosion). Results show that 55% of the products passed the test whereas 33% are for temporary use as slight corrosion occurred on at least one metal coupon and only 11% failed the Oddy test. Raman measurements of the corrosion products identified oxides like massicot, litharge, cuprite, and tenorite among carbonates (hydrocerussite, plumbonacrite), and acetates like basic lead acetate, lead acetate trihydrate as well as lead formate as main phases. For example, commercial, industrial Klucel® G (HPC) scored a T rating through slight corrosion on the lead coupon. Basic lead acetate among other phases indicates the presence of acetic acid. Additional measurements of the sample with thermal desorption GC–MS utilizing the BEMMA scheme confirm the high acetic acid outgassing and reveal the presence of a small amount of formaldehyde.
Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt.
Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes.
Indoor air quality is affected by the emission of volatile organic compounds (VOC) or the odour from building products. Odours can be measured by applying the standard ISO 16000-28:2020.
In the study presented here proposals for further technical development of the ISO method are presented. The sampling procedure and evaluation
method of the perceived intensity are investigated in particular because they have a major influence on reproducibility of measurement results.
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.
The aim of this study was the development of a low volume air sampling strategy for biocides and polychlorinated biphenyls (PCB) at low air change rates in modern, air-tight showcases as they are present in museums. Lindane, pentachlorophenol, dichlofluanid, tolyfluanid, isodrin, p,p-dichlorodiphenyl trichloroethane and permethrin were the biocides and PCB 28 and PCB 153 were the PCBs studied, all of which are semi volatile organic compounds (SVOC). Their occurrences in the museum environment originate from various sources e.g. preventive treatment of organic exhibits or organic building materials. Exhibits are long-term exposed to these pollutants due to storing in showcases or other storage equipment at low air change rates. To achieve air sampling under the aforementioned conditions the influences of temperature, air circulation, air change rate and relative humidity on the emission behavior of the selected biocides and PCBs had to be determined. This was carried out with pre-soaked wood samples in low volume air sampling experiments using 27 L test showcases and 23 L and 24 L emission test chambers and also diffusive sampling with glass as the sampling material.
Generation of reproducible chamber concentrations for round robin tests based on reference materials
(2013)
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany.
Development of a multi-VOC reference material for quality assurance in materials emission testing
(2015)
Emission test chamber measurement is necessary to proof building materials as sources of volatile organic compounds (VOCs). The results of such measurements are used to evaluate materials and label them according to their potential to emit harmful substances, polluting indoor air. If only labelled materials were installed indoors, this would improve indoor air quality and prevent negative impacts on human health. Because of the complex testing procedure, reference materials for the quality assurance are mandatory. Currently, there is a lack of such materials because most building products show a broad variation of emissions even within one batch. A previous study indicates lacquers, mixed with volatile organic pollutants, as reproducible emission source for a wide range of substances. In the present study, the curing of the lacquer-VOC mixture inside micro-chambers was optimised. Therefore, the humidity and the chamber flow were varied. Typical indoor air pollutants with a wide range of volatilities, for example, styrene, n-hexadecane, dimethyl and dibutyl phthalate were selected. It turned out that, under optimised curing parameters inside the micro-chamber, their emission can be reproduced with variations of less than 10 %. With this, a next important step towards a reference material for emission testing was achieved.
The DIN ISO 16000-28 and VDI 4302-1 describe a method for the assessment of the perceived intensity of odours. It is based on a trained assessment panel using a referencing scale that provides defined acetone concentrations. Due to the AgBB-scheme including a place holder for odour assessment it is currently checked whether the method is applicable.
To check the applicability a pilot phase regarding the „Implementation of Odour Measurements into the Assessment of Building Products“ was started by AgBB1 in 2012. Düring this phase amongst others two interlaboratory tests were conducted. The first one in 2012 served to test the applicability and to identify need and potential for improvement. Based on those findings an additional Standard Operation procedure was developed for the second interlaboratory test in 2014.
The second interlaboratory test confirmed the findings of the first one and the need for improvement of the measurement method as well. Nonetheless both tests showed Standard deviations of reproducibility between 20 and 40%. Standard deviations of reproducibility of well-established interlaboratory tests for VOCs show comparable results.
Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten.
Während in der Vergangenheit insbesondere die Entwicklung einer sensorischen Prüfmethode (in DIN ISO 16000-28 und VDI 4302-1 genormt und im AgBB-Schema verankert) für die Bewertung von Bauprodukten im Vordergrund der Betrachtungen stand, wurde im Rahmen der vom UBA initiierten Pilotphase mithilfe des Ringversuches erstmals die institutsübergreifende Anwendbarkeit dieser Verfahren untersucht. Ziel dabei war es, noch bestehende Schwierigkeiten im Umgang mit der Prüfmethode zu identifizieren und Empfehlungen für das weitere Vorgehen herauszuarbeiten.
While in 2012 a commercially available acrylic sealant was used as sample material, in 2014 a lacquer doped with specific substances was sent to the participants for the VOC and odour measurement. The resulting measurement values for the perceived intensity were evaluated in consideration of various boundary conditions to identify parameters that could possibly influence the measurement procedure significantly. For the comparison of both interlaboratory comparisons qualified data sets were taken as a basis. Potential for improvement identified in 2012 was mainly confirmed by the interlaboratory test 2014 as well. Besides the accurate conduction as essential part of the measurement it became obvious again that the boundary conditions of the DIN ISO 16000-28 are not defined tight enough. Moreover the thesis that measurements based on the utilisation of comparison scales with only one funnel generate results especially imprecise could not be verified. Both interlaboratory comparisons resulted in relative standard deviations of reproducibility that lay between 20 and 40 % and such are quite comparable with those of well-established interlaboratory VOC comparisons.
Two new approaches towards an emission reference material for use in quality assurance measures for materials emissions testing were developed and intensively tested. The overall goal was to obtain solid materials with homogenous and reproducible (S)VOC release. Since the application in inter-laboratory comparisons is aimed at, it should furthermore be long-term stable to ensure safe shipment to the customer without sustaining compound losses. In the first approach, thermoplastic polyurethane (TPU) was impregnated with the VOC texanol under high-pressure with liquid CO2 as solvent. In the second, styrene (VOC) and the SVOC 2,6-diisopropylnaphthalene (DIPN) were spiked into vacuum grease (VG) and a mixture of paraf-fin/squalane (P/S). For the prediction of the emission rates a finite element model (FEM) was developed for the VG and P/S type materials. All requirements for reference materials were fulfilled, whereas the TPU samples need to be aged for about 10 days until repeatable and re-producible emission rates were obtained.
BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Ergebnisse der Untersuchungen seit ca. 2010 bis 2017 werden präsentiert und diskutiert.
Anregungen aus dem N.i.Ke.-Workshop 2017 und künftige Anforderungen. BEMMA steht für Bewertung von Emissionen aus Materialien für Museumsausstattungen. Es ist die Kurzbezeichnung für ein Schema/Verfahren zur Untersuchung und Bewertung flüchtiger organischer Verbindungen aus Werkstoffen, die im mittelbaren Kontakt mit historischen Materialien des Kunst- und Kulturgutes stehen. Hier wird der Status-Quo des Erreichten dargestellt. Wie wird das Schema in der Museumsöffentlichkeit wahrgenommen und seine Akzeptanz.
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail.
Since some volatile organic compounds (VOC) are
dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks.
Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. The basic evaluation for the values used for first assessments were a ZIM-project with nearly 100 tested materials. In-between more than 100 new materials were tested and enlarged the knowledge about material emissions from display case materials. Mainly silicone sealing materials were tested due to the fact that this group of material have the highest emissions. With regard to the testing procedure only construction materials were evaluated, not the display cases their self. Nevertheless in combination with the certificate also designed by BAM additionally the further steps of construction can be taken into account. So other factors such as age and storage time of materials, tightness respectively air change rate, air condition or ventilation of display cases can be included in the evaluation.
Design of Reference Materials for Proficiency Tests for Measurements in Emission Test Chambers
(2017)
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results.
Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found.
Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Currently, the second approach is not at a level that it could be tested within a RRT.
Important requirements for the production of a reference material were repeatability (homogeneity), reproducibility, long-term stability in terms of compound release and transport stability. The emission rates should be high enough to obtain well measurable chamber air concentrations at standardised test conditions.
The lacquer samples were prepared by weighing portions of a water-based lacquer to which defined amounts of the pure analytes were added. Defined amounts of the lacquer mixture were filled into Petri dishes and cured under standard conditions (23 °C and 50% relative humidity). Reproducible emissions were obtained when the storage time of the cured material was not longer than four weeks. The concentrations were analyzed 7 days after loading of the material into the chamber.
Two RRT were conducted by use of the lacquer system. Here, the laboratories had to identify and also to quantify the compounds. The relative standard deviations obtained were typical for such a kind of test. More than 50 participants reported results.
Volatile Organic Compounds (VOC) are ubiquitous in the indoor air since they are emitted from materials used indoors. Investigations of these materials are mostly carried out in emission test chambers under controlled climatic conditions. Reference materials are an important tool for quality assurance/Quality control of emission test chamber measurements but so far they are not commercially available. In this study, a new approach was tested to develop an appropriate reference material with homogenous and reproducible emission of the VOC with well measurable air concentrations in emission test Chambers larger than 20 L at air change rates of 0.5 - 1 /h.
Thermoplastic Polyurethane (TPU) was selected as Matrix material which was impregnated with 2,2,4- trimethyl-1,3-pentanediol monoisobutyrate (texanol) as test VOC using compressed carbon dioxide. An optimization of the impregnation parameters such as temperature, pressure, time, VOC injection volume and TPU sample size was performed until the targeted area specific Emission rate (SERa) value was reached. Further aspects like process control, storage effects and correlation of the sample size to the emission rate were investigated. It was found that the SERa immediately after sample preparation were not reproducible between the batches but became unified 10 days after loading into the test chamber indicating the necessity of aging before use. SERa between 13,000 and 18,000 mg m-2 h-1 were obtained, and the impregnated materials could be well stored in aluminum-coated polyethylene foil for at least seven weeks without significant losses. Furthermore, the impregnation of styrene and the SVOC 2,6-diisopropylnaphthalene was tested.