Using the AgBB evaluation scheme for VOC and odour emissions of different construction products
(2006)
Methods for the determination of biocide emissions from treated materials into water and air were developed and tested in order to support a comparative ecological assessment of biocidal products. Leaching tests, experiments with simulated rain, extraction cleaning of carpets and emission chamber tests were performed with a series of treated materials. The experiments focused on the effect of changes in the procedure as well as characteristics of the specimens and demonstrate the suitability of the proposed methods for biocides of different product types.
It was demonstrated that emissions of biocides into water can be compared on the basis of leaching tests in which the emission kinetics of the active ingredients are recorded. However, the water volume per surface area and the timetable for water changes have to be defined in such tests. Functions of flux rates related to time can be well described for inorganic compounds, whereas modelling of the data is more complicated for organic substances.
Emission chamber tests using 20-litre and 23-litre glass exsiccators, originally developed to study volatile organic compounds, were successfully adapted for the investigation of the emission of biocides from treated materials which are usually semi volatile organic compounds. However, test parameters and the method of analysis have to be adapted to the substances to be determined.
Generally, it was found that the emission curves for the semi volatile organic compounds investigated differ from those of volatile organic compounds.
Kurzfassung An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unter- schiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden.
Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL UZ 62, RAL UZ 85 sowie des neuen RAL UZ 114 für Multifunktionsgeräte darstellt. Abstract The emission behaviour with regard to dust, ozone and VOC (TVOC) of nine different hardcopy devices in combination with suitable air sampling and analysis procedures was investigated in different emission test chambers (two different 1 m³ - chambers and one 20 m³ - chamber). Air sampling and analysis for VOC were done by means of Tenax TA and subsequent thermal desorption (TDS) in connection with GC / MS. Ozone was determined continuously. The ozone analyser worked on the basis of the flame rid reaction of ozone with ethylene according to the principle of chemiluminescence. The dust determination was done gravimetrically by means of glass fibre filter and an ultra micro - balance. Additional the particle emission during the printing process was measured with a particle counter. The general technical conditions of the tested hardcopy devices were the reason for short printing times with a maximum of 36 minutes. In order to achieve the equilibrium concentration in the test chambers the air exchange rate in the 1 m³ - test chambers had to be increased to a value of n = 4,0 to 4,7 per hour. Additional to the examination of the hardcopy devices in the emission test chambers different papers were investi- gated by means of direct - TDS and different toners were tested by means of head space sampling in combination with GC / MS. For the examined hardcopy devices emission rates were determined. The emission rates for TVOC ranged from 0,41 to 22,4 mg per piece and hour, for ozone from less than 0,02 to 4,6 mg per piece and hour and for dust from 0,10 to 7,63 mg per piece and hour. The comparison between recycling paper and paper produced from primary fibres showed in general higher SVOC emissions from recycling paper. As the result of the investigations a test method for the determination of emissions from hardcopy devices was developed. This test method is the basis for emission tests in the framework of the German Award of the Environmental Label for office devices RAL -UZ 62, RAL -UZ 85 and the new RAL -UZ 114 for multifunctional devices.
Background to the studies was the revision of the current selection criteria of the German ecolabel Blauer Engel (Blue angel) for copiers and printers. In the requirements limits were set for ozone, dust and styrene emissions. The former test methods did no longer correspond to todays requirements with regard to emission measurements. In addition, the emission behaviour of hardcopy devices due to the use of different and non-com parable test methods has been recently discussed controversely. For this reason a new test method had to be developed which enables a reliable, reproducible determination of emission rates (ER) for dust, ozone and VOC (volatile organic compounds). The basis for this was the ECMA-Standard 328 compiled by ECMA (European Computer Manufacturer Association) using dynamic chamber measurements. Nine different machines, desktop laser printers as well as office devices like bigger copiers and multifunctional devices were investigated. As a result of the study new criteria for the Blauer Engel for copiers, printers and a new created for multifunctional devices, concerning TVOC, ozone and dust emission were determined. Additionally a model is presented calculating the concentrations in real rooms under usual printing conditions derived from the test chamber results.
The development of a gas mixing system (GMS) that enables dynamic and retraceable production of stable long-term VOC gas mixtures within the ppb range is discussed. In this system pure liquid substances are kept separately at a constant temperature, evaporated according to their vapour pressure and removed by a small inert gas flow. A modular set-up allows flexible handling. All vapours generated are finally united in a mixing chamber. Any concentration level of the gas mixture can be produced by a suitable combination of evaporation temperature, carrier and dilution gas flows. Test results from continuous operation over six weeks are presented. The equipment was tested on seven volatile organic compounds (VOC) of different vapour pressure ranges. It was possible to establish stable operation for the equipment during the entire period and reproducible gas concentrations which were traceable to the mass as an SI unit, thus the system is suitable for long-term tests.---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Im Beitrag wird die Entwicklung eines Gasmischsystems (GMS) beschrieben, das die dynamische und rückführbare Generierung von langzeitstabilen VOC-Gasgemischen im ppb-Bereich erlaubt. Dabei werden Reinsubstanzen separat temperiert, ihrem Dampfdruck entsprechend verdampft und durch einen kleinen Inertgasstrom abgeführt. In einer Mischkammer werden sie schließlich zusammengeführt. Durch die Kombination von Verdampfungstemperatur, Träger- und Verdünnungsgasflüssen ist die Einstellung eines beliebigen Konzentrationsniveaus des Gasgemischs möglich. Aus einem Dauerbetrieb von sechs Wochen werden Untersuchungsergebnisse gezeigt. Dabei wurde die Apparatur mit insgesamt sieben flüchtigen organischen Verbindungen (VOC) unterschiedlicher Dampfdruckbereiche betrieben. Die Anlage lief über den gesamten Zeitraum stabil und lieferte reproduzierbare und auf die Masse als SI-Einheit rückführbare Gaskonzentrationen. Somit ist das Verfahren für Langzeitanwendungen geeignet.
Since semi-volatile organic compounds (SVOCs), including biocides and polychlorinated biphenyls (PCBs), occur indoors as well as outdoors, air sampling adsorbents and measuring methods for all these compounds are indispensable. This paper presents the initial steps in the development of such a method, the aim of which is the analysis of selected compounds in the above-mentioned classes using low air sampling volumes and air-exchange rates close to zero, as is common in museum showcases. For measurements under easily controlled conditions, a micro-chamber system was used at different temperatures. A surface modified styrene divinylbenzene (SDVB) polymer was selected as the air sampling adsorbent for the elution experiments. After successfully performing pretests using the micro-chamber system with target compound solutions, the emissions of these compounds from self-soaked wood samples and con-taminated wood samples were investigated for method development.
In this study 50 construction products were tested in emission test chambers according to the requirements of the AgBB-scheme: 7 acrylic and 6 silicone sealants, 6 paste-like synthetic resin plasters, 13 wood based products, 4 adhesives, 5 lacquers, 6 wall paints and 3 further construction products. VOC and odour emissions were tested on the 1st, 3rd, 10th, and 28th day. In addition to the VOC-measurements, a test procedure was developed to evaluate odour emission of construction products.This test is planned to be implemented into the AgBB-Scheme. A direct evaluation by a sensory panel in the emission test chamber was not possible. So the odour samples were collected in 300- litre tedlar bags which were evaluated later. Odour intensity of the samples was compared with different acetone concentrations. Within this study an interlaboratory comparison was conducted using the newly developed odour test method. Additionally, VVOC emissions, detection of carcinogenic compounds, repeatability of emission test chamber tests, and other issues are presented. This project has shown that construction products can be evaluated in accordance with the AgBB scheme. A sensory evaluation is intended to be introduced in the AgBB scheme. A method for this evaluation is described in this study. The test procedure should be enhanced and validated for practical utilisation.
Most VVOC were rarely considered in the evaluation of construction products. (Salthammer, 2014) In Germany this will change because the latest version of the German AgBB scheme for health evaluation (2015) now include VVOC, e.g. ethyl acetate and ethanol. In this study selected compounds were tested with the procedure described in ISO 16017 and a method for measuring VVOC with thermal desorption was developed.
Three different adsorbents Tenax TA, Carbograph 5TD and Carbopack X were tested to analyse VVOC according to ISO 16017. For the tested VVOC, Carbograph 5TD showed the best results under the chosen analytical conditions.
Volatile organic compounds (VOCs) found indoors have the potential to affect human health. Typical sources include building materials, furnishings, cleaning agents, etc. To address this risk, chemical emission testing is used to assess the potential of different materials to pollute indoor air. One objective of the European Joint Research Project 'MACPoll' (Metrology for Chemical Pollutants in Air) aims at developing and testing a reference material for the quality control of the emission testing procedure. Furthermore, it would enable comparison of measurement results between test laboratories. The heterogeneity of the majority of materials makes it difficult to find a suitable reference sample.
In the present study, styrene, 2-ethyl-1-hexanol, N-methyl-α-pyrrolidone, lindane, n-hexadecane, 1,2-dimethyl- and 1,2-di-n-butyl-phthalate were added to 12 commercially available lacquers (6 alkyd and 6 acrylic polymer based lacquers) serving as carrier substrate. After homogenization, the mixtures were loaded into a Markes Micro-Chamber/Thermal Extractor (µ-CTE) for curing and investigation of the emission behavior for each compound. For almost all of the investigated chemicals, the preferred glossy acrylic lacquer showed emissions that were reproducible with a variation of less than 20% RSD. Such lacquer systems have therefore been shown to be good candidates for use as reference materials in inter-laboratory studies.
Odours might cause offensive nuisance and are under suspicion to be directly harmful to health. Surprisingly their assessment is by definition no part of the determination of indoor air quality (yet). As odours emit from building materials as well as from common consumer goods the users awareness increases continuously and demand for improved consumer protection raises. In comparison to well established methods for the determination of volatile organic compounds (VOC) in the air, there is little experience regarding the applicability, comparability and reproducibility of odour measurements. Considering this, the international and the German standardisation take into account odour assessment, e.g. ISO 16000-28 and VDI 4302-1.
In Germany the AgBB-Scheme is a mandatory tool for the evaluation of building products and it is intended to implement odour measurement into it. Initially and essentially the newly developed method had to be put to test involving institutes that deal with VOC measurements. To test the applicability of the method an interlaboratory test was conducted. The results and identified potential improvements are presented in this study (Brosig, 2013).
With a gas mixing system (GMS) developed in our laboratory we created a gas mixture of
four substances. Adsorptive wall materials of four different compositions were exposed to this
gas mixture, consisting of 1-pentanol, hexanal, butyl acetate and n-decane. Aim of this study
was to scrutinize the ability of these samples to reduce the concentration of the supplied gas.
This capacity is expressed in the sorption flux F or area specific adsorption rate respectively.
The test was performed referring to a draft of ISO 16000-24.
Correlation of aldehyde emissions and fatty acids content in pine wood and oriented strand boards
(2011)
Indoor air quality is important for human health and comfort. To ensure good indoor air quality contamination by volatile organic compounds (VOC) should be minimised. The aim of the project is the reduction of unsaturated aldehydes which can emit from oriented Strand boards (OSB): These aldehydes have an impact on the health based evaluation of emissions from products for indoor use according to the AgBB (Ausschuss zur gesundheitlichen Bewertung von Bauprodukten, Committee for Health Evaluation of Building Products) scheine (AgBB 2010). The model OSB were produced in a pilot plant using well known raw materials (Pinus sylvestris at different trunk heights) under using various processing parameters (Wilke et al. 2011).
OSB emit predominantly monoterpenes and aldehydes. Aldehydes are oxidation products of fatty acids in wood. The conditions which affect the oxidation process are the fatty acid concentration and composition, the oxygen content, the sample surface and the presence of compounds which indicate, inhibit or stop the oxidation respectively. The oxidation rate rises with an increasing number of double bounds in the fatty acid, e.g. the oxidation rate between oleic, linoleic and linolenic acid correspond to 1:12:24. One of the most important products of fatty acid oxidation is hexanal. It is generated during the oxidation of linoleic acid. This study shows a direct correlation between aldehyde emission and oxidation, hexanal can be used as an indicator for oxidation.
Indoor air pollutants influence the health and comfort of building occupants and consequently the energy consumption of the building. The pollutants are emitted by various sources.
Among these sources, building products are of particular importance. To control the emission of pollutants from building materials, a few different voluntary labelling Systems have been introduced in Europe. In Germany also mandatory “Principles for the health assessment of construction products used in interiors” have been applied for the technical approval of floor coverings since 2004. This procedure is based on the assessment scheine of the Committee for Health-related
Evaluation of Building Products (AgBBScheme). The sensory-limit settings for building-material label Blue Angel offer consumer to differ not only low-emission but also low-odour Building materials from another building materials.
Product emissions chamber testing involves a complex protocol with several sources of measurement uncertainty (ASTM, 2010; ISO, 2006). Despite the potential for significant variability in measurement results within and among laboratories, there is no Standard method available to assess the accuracy of emissions chamber test results. Recently, Germany’s Federal Institute for Materials Research and Testing (BAM) started a program to evaluate the performance of laboratories testing for the AgBB (German Committee for Health-related Evaluation of Building Products) labelling scheme (Wilke et al., 2009). Test method validation was conducted through interlaboratory studies (ILS) with over 30 participants. Simultaneously, the National Institute of Standards and Technology (NIST) and Virginia Tech (VT) started a program to develop a series of reference materials that mimic real building products, can be tested in typical emissions chambers, and have independently known emission rates (Cox et al., 2010). BAM, NIST and VT subsequently joined forces to conduct a series of inter-laboratory studies using the prototype reference material. A pilot ILS was conducted with BAM and NIST followed by an expanded ILS with several participating countries. Results from these interlaboratory studies have the potential to define an internationally-accepted Standard approach to validate results from product emissions tests.
Besides measurement of VOC emissions also the evaluation of odour emissions and the perceived intensity of odours gains in importance. Due to difficulties detected in the measurement method of the perceived intensity described in (ISO 16000-28, 2012) the introduction of “reference” odours will be recommended for the training of panellists and as basis for interlaboratory comparisons.
In order to generate the “reference” odours standard liquid substances were directly injected into the main gas flow provided to the panellists. One of the substances tested was ethyl acetate. A pre-evaluation was conducted with six untrained panellists and has shown that ethyl acetate is potentially suitable as reference odour. For further validation of those “reference” odours they additionally will be provided to and evaluated by trained panellists of well established-measurement institutes.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap 300 (R) (a multi-bed tube using Carbopack C (R), Carbopack B (R) and Carbosive SIII (R)) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber.
Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically, air exchange rates are often smaller than 0.1 d-1, which can result in rising concentrations of potential harmful VOC inside of the display cases due to emissions from materials. Especially organic acids, e. g. formic or acetic acid which can emit from e.g. sealing materials or wood-based materials, can produce damage of cultural objects.
In 2012 BAM introduced a procedure which is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museums¬ausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Regarding the testing procedure only construction materials were evaluated, not the display cases their self. Micro chambers are used for VOC emission tests of display case construction materials, e.g. plastics, sealing materials, coatings, textiles and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde, piperidine-derivates and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme.
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.
The aim of this study was the development of a low volume air sampling strategy for biocides and polychlorinated biphenyls (PCB) at low air change rates in modern, air-tight showcases as they are present in museums. Lindane, pentachlorophenol, dichlofluanid, tolyfluanid, isodrin, p,p-dichlorodiphenyl trichloroethane and permethrin were the biocides and PCB 28 and PCB 153 were the PCBs studied, all of which are semi volatile organic compounds (SVOC). Their occurrences in the museum environment originate from various sources e.g. preventive treatment of organic exhibits or organic building materials. Exhibits are long-term exposed to these pollutants due to storing in showcases or other storage equipment at low air change rates. To achieve air sampling under the aforementioned conditions the influences of temperature, air circulation, air change rate and relative humidity on the emission behavior of the selected biocides and PCBs had to be determined. This was carried out with pre-soaked wood samples in low volume air sampling experiments using 27 L test showcases and 23 L and 24 L emission test chambers and also diffusive sampling with glass as the sampling material.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany.
Development of a multi-VOC reference material for quality assurance in materials emission testing
(2015)
Emission test chamber measurement is necessary to proof building materials as sources of volatile organic compounds (VOCs). The results of such measurements are used to evaluate materials and label them according to their potential to emit harmful substances, polluting indoor air. If only labelled materials were installed indoors, this would improve indoor air quality and prevent negative impacts on human health. Because of the complex testing procedure, reference materials for the quality assurance are mandatory. Currently, there is a lack of such materials because most building products show a broad variation of emissions even within one batch. A previous study indicates lacquers, mixed with volatile organic pollutants, as reproducible emission source for a wide range of substances. In the present study, the curing of the lacquer-VOC mixture inside micro-chambers was optimised. Therefore, the humidity and the chamber flow were varied. Typical indoor air pollutants with a wide range of volatilities, for example, styrene, n-hexadecane, dimethyl and dibutyl phthalate were selected. It turned out that, under optimised curing parameters inside the micro-chamber, their emission can be reproduced with variations of less than 10 %. With this, a next important step towards a reference material for emission testing was achieved.
While in 2012 a commercially available acrylic sealant was used as sample material, in 2014 a lacquer doped with specific substances was sent to the participants for the VOC and odour measurement. The resulting measurement values for the perceived intensity were evaluated in consideration of various boundary conditions to identify parameters that could possibly influence the measurement procedure significantly. For the comparison of both interlaboratory comparisons qualified data sets were taken as a basis. Potential for improvement identified in 2012 was mainly confirmed by the interlaboratory test 2014 as well. Besides the accurate conduction as essential part of the measurement it became obvious again that the boundary conditions of the DIN ISO 16000-28 are not defined tight enough. Moreover the thesis that measurements based on the utilisation of comparison scales with only one funnel generate results especially imprecise could not be verified. Both interlaboratory comparisons resulted in relative standard deviations of reproducibility that lay between 20 and 40 % and such are quite comparable with those of well-established interlaboratory VOC comparisons.
Two new approaches towards an emission reference material for use in quality assurance measures for materials emissions testing were developed and intensively tested. The overall goal was to obtain solid materials with homogenous and reproducible (S)VOC release. Since the application in inter-laboratory comparisons is aimed at, it should furthermore be long-term stable to ensure safe shipment to the customer without sustaining compound losses. In the first approach, thermoplastic polyurethane (TPU) was impregnated with the VOC texanol under high-pressure with liquid CO2 as solvent. In the second, styrene (VOC) and the SVOC 2,6-diisopropylnaphthalene (DIPN) were spiked into vacuum grease (VG) and a mixture of paraf-fin/squalane (P/S). For the prediction of the emission rates a finite element model (FEM) was developed for the VG and P/S type materials. All requirements for reference materials were fulfilled, whereas the TPU samples need to be aged for about 10 days until repeatable and re-producible emission rates were obtained.
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail.
Since some volatile organic compounds (VOC) are
dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks.
Museums worldwide are equipped with different display cases. Exhibit display cases should protect cultural objects from dust as well as from mechanical and physical damage. To ensure a stable climate inside the display cases, a low air exchange rate is maintained. Typically air exchange rates are often smaller than 0.1 d 1, which can result in rising concentrations of potential harmful immissions inside of the display cases due to emissions from materials. Especially high concentrations of organic acids, which can emit from e.g. sealing materials, can produce damage of cultural objects. In 2012 BAM introduced a procedure witch is called: BEMMA-Scheme (Bewertung von Emissionen aus Materialien für Museumsausstattungen) which stands for: “Assessment of Emissions from Materials for Museum Equipment”. Micro chambers are used for VOC emission tests of display case construction materials, e.g. textiles, plastics, sealing material, coatings and others. Each sampling procedure is carried out in duplicate. Emissions like formic acid, acetic acid, formaldehyde and oximes are excluded and the sum of emissions of VVOCs, VOCs and SVOCs is limited. For a positive assessment all listed criteria must be fulfilled; otherwise the display construction material fails the BEMMA scheme. The BEMMA scheme is not a guarantee for an emission free display case, but a necessary requirement for the choice of suitable materials for emission and immission reduced display cases. The basic evaluation for the values used for first assessments were a ZIM-project with nearly 100 tested materials. In-between more than 100 new materials were tested and enlarged the knowledge about material emissions from display case materials. Mainly silicone sealing materials were tested due to the fact that this group of material have the highest emissions. With regard to the testing procedure only construction materials were evaluated, not the display cases their self. Nevertheless in combination with the certificate also designed by BAM additionally the further steps of construction can be taken into account. So other factors such as age and storage time of materials, tightness respectively air change rate, air condition or ventilation of display cases can be included in the evaluation.
Design of Reference Materials for Proficiency Tests for Measurements in Emission Test Chambers
(2017)
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results.
Any commercially available product on the market can be used as reference material, provided it is thoroughly characterised. However, these materials often emit only a few and material specific VOCs and appropriate homogeneity is not given. Therefore, alternative materials should be found.
Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Currently, the second approach is not at a level that it could be tested within a RRT.
Important requirements for the production of a reference material were repeatability (homogeneity), reproducibility, long-term stability in terms of compound release and transport stability. The emission rates should be high enough to obtain well measurable chamber air concentrations at standardised test conditions.
The lacquer samples were prepared by weighing portions of a water-based lacquer to which defined amounts of the pure analytes were added. Defined amounts of the lacquer mixture were filled into Petri dishes and cured under standard conditions (23 °C and 50% relative humidity). Reproducible emissions were obtained when the storage time of the cured material was not longer than four weeks. The concentrations were analyzed 7 days after loading of the material into the chamber.
Two RRT were conducted by use of the lacquer system. Here, the laboratories had to identify and also to quantify the compounds. The relative standard deviations obtained were typical for such a kind of test. More than 50 participants reported results.
Volatile Organic Compounds (VOC) are ubiquitous in the indoor air since they are emitted from materials used indoors. Investigations of these materials are mostly carried out in emission test chambers under controlled climatic conditions. Reference materials are an important tool for quality assurance/Quality control of emission test chamber measurements but so far they are not commercially available. In this study, a new approach was tested to develop an appropriate reference material with homogenous and reproducible emission of the VOC with well measurable air concentrations in emission test Chambers larger than 20 L at air change rates of 0.5 - 1 /h.
Thermoplastic Polyurethane (TPU) was selected as Matrix material which was impregnated with 2,2,4- trimethyl-1,3-pentanediol monoisobutyrate (texanol) as test VOC using compressed carbon dioxide. An optimization of the impregnation parameters such as temperature, pressure, time, VOC injection volume and TPU sample size was performed until the targeted area specific Emission rate (SERa) value was reached. Further aspects like process control, storage effects and correlation of the sample size to the emission rate were investigated. It was found that the SERa immediately after sample preparation were not reproducible between the batches but became unified 10 days after loading into the test chamber indicating the necessity of aging before use. SERa between 13,000 and 18,000 mg m-2 h-1 were obtained, and the impregnated materials could be well stored in aluminum-coated polyethylene foil for at least seven weeks without significant losses. Furthermore, the impregnation of styrene and the SVOC 2,6-diisopropylnaphthalene was tested.
Volatile Organic Compounds (VOC) are ubiquitous in the indoor air, since they emit from materials used indoors. Investigations of these materials are mostly carried out in test chambers under controlled climatic conditions. Quality control of these test chamber measurements is important but there is a lack of commercially available homogenous reference materials as required for round robin tests or quality assurance of laboratories. The approach of the present study is the impregnation of a supporting material with VOC, which are reproducibly released in measurable chamber air concentrations under standardised test conditions. A polymer made of Thermoplastic Polyurethane (TPU) was chosen as carrier material. It was impregnated with the VOC trimethyl pentanediol isobutyrat (texanol).
Recent research into emissions of (semi-)volatile organic compounds [(S)VOC] from solid materials has focused on the development of suitable reference materials for quality assurance/quality control of emission test chamber measurements, which fulfill requirements such as homogenous and reproducible (S)VOC release. The approach of this study was to find a method for preparation of a material with predictable (S)VOC emission rates. AVOC (styrene) and an SVOC (2,6-diisopropylnaphthalene, DIPN), loaded into either vacuum grease or a 1:1 mixture of paraffin/squalane, have been tested. For the prediction of the emission rates, a model using the finite element method (FEM) was created to simulate the (S)VOC emission profiles. Theoretical and experimental results obtained in a Micro-Chamber/Thermal Extractor (μ-CTE™) and in 24 L emission test chamber measurements were in good agreement. Further properties were investigated concerning the material applicability, such as shelf life and inter-laboratory comparability. The maximum relative standard deviation in the inter-laboratory study was found to be 20%.
Since some volatile organic compounds (VOC) are dangerous to human health whilst others cause harm to the environment by influencing the oxidative capacity of the atmosphere, the overall aim of the KEY-VOCs project is to improve the measurement infrastructure for Key Volatile Organic Compounds in indoor and outdoor air. This is done by providing traceable and comparable reference gas standards and by validating new measurement systems in support to the air monitoring networks.
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail.