Methods for the determination of biocide emissions from treated materials into water and air were developed and tested in order to support a comparative ecological assessment of biocidal products. Leaching tests, experiments with simulated rain, extraction cleaning of carpets and emission chamber tests were performed with a series of treated materials. The experiments focused on the effect of changes in the procedure as well as characteristics of the specimens and demonstrate the suitability of the proposed methods for biocides of different product types.
It was demonstrated that emissions of biocides into water can be compared on the basis of leaching tests in which the emission kinetics of the active ingredients are recorded. However, the water volume per surface area and the timetable for water changes have to be defined in such tests. Functions of flux rates related to time can be well described for inorganic compounds, whereas modelling of the data is more complicated for organic substances.
Emission chamber tests using 20-litre and 23-litre glass exsiccators, originally developed to study volatile organic compounds, were successfully adapted for the investigation of the emission of biocides from treated materials which are usually semi volatile organic compounds. However, test parameters and the method of analysis have to be adapted to the substances to be determined.
Generally, it was found that the emission curves for the semi volatile organic compounds investigated differ from those of volatile organic compounds.
Background to the studies was the revision of the current selection criteria of the German ecolabel Blauer Engel (Blue angel) for copiers and printers. In the requirements limits were set for ozone, dust and styrene emissions. The former test methods did no longer correspond to todays requirements with regard to emission measurements. In addition, the emission behaviour of hardcopy devices due to the use of different and non-com parable test methods has been recently discussed controversely. For this reason a new test method had to be developed which enables a reliable, reproducible determination of emission rates (ER) for dust, ozone and VOC (volatile organic compounds). The basis for this was the ECMA-Standard 328 compiled by ECMA (European Computer Manufacturer Association) using dynamic chamber measurements. Nine different machines, desktop laser printers as well as office devices like bigger copiers and multifunctional devices were investigated. As a result of the study new criteria for the Blauer Engel for copiers, printers and a new created for multifunctional devices, concerning TVOC, ozone and dust emission were determined. Additionally a model is presented calculating the concentrations in real rooms under usual printing conditions derived from the test chamber results.
The development of a gas mixing system (GMS) that enables dynamic and retraceable production of stable long-term VOC gas mixtures within the ppb range is discussed. In this system pure liquid substances are kept separately at a constant temperature, evaporated according to their vapour pressure and removed by a small inert gas flow. A modular set-up allows flexible handling. All vapours generated are finally united in a mixing chamber. Any concentration level of the gas mixture can be produced by a suitable combination of evaporation temperature, carrier and dilution gas flows. Test results from continuous operation over six weeks are presented. The equipment was tested on seven volatile organic compounds (VOC) of different vapour pressure ranges. It was possible to establish stable operation for the equipment during the entire period and reproducible gas concentrations which were traceable to the mass as an SI unit, thus the system is suitable for long-term tests.---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Im Beitrag wird die Entwicklung eines Gasmischsystems (GMS) beschrieben, das die dynamische und rückführbare Generierung von langzeitstabilen VOC-Gasgemischen im ppb-Bereich erlaubt. Dabei werden Reinsubstanzen separat temperiert, ihrem Dampfdruck entsprechend verdampft und durch einen kleinen Inertgasstrom abgeführt. In einer Mischkammer werden sie schließlich zusammengeführt. Durch die Kombination von Verdampfungstemperatur, Träger- und Verdünnungsgasflüssen ist die Einstellung eines beliebigen Konzentrationsniveaus des Gasgemischs möglich. Aus einem Dauerbetrieb von sechs Wochen werden Untersuchungsergebnisse gezeigt. Dabei wurde die Apparatur mit insgesamt sieben flüchtigen organischen Verbindungen (VOC) unterschiedlicher Dampfdruckbereiche betrieben. Die Anlage lief über den gesamten Zeitraum stabil und lieferte reproduzierbare und auf die Masse als SI-Einheit rückführbare Gaskonzentrationen. Somit ist das Verfahren für Langzeitanwendungen geeignet.
Since semi-volatile organic compounds (SVOCs), including biocides and polychlorinated biphenyls (PCBs), occur indoors as well as outdoors, air sampling adsorbents and measuring methods for all these compounds are indispensable. This paper presents the initial steps in the development of such a method, the aim of which is the analysis of selected compounds in the above-mentioned classes using low air sampling volumes and air-exchange rates close to zero, as is common in museum showcases. For measurements under easily controlled conditions, a micro-chamber system was used at different temperatures. A surface modified styrene divinylbenzene (SDVB) polymer was selected as the air sampling adsorbent for the elution experiments. After successfully performing pretests using the micro-chamber system with target compound solutions, the emissions of these compounds from self-soaked wood samples and con-taminated wood samples were investigated for method development.
Vor dem Hintergrund der notwendigen Revision der Kriterien zur Vergabe des Gütezeichens "Blauer Engel" für Laserdrucker, Kopierer und Multifunktionsgeräte mussten auch die Prüfmethoden angepasst werden, da die alten Verfahren nicht mehr die heutigen Anforderungen der Emissionsmessung erfüllen. In diesem Zusammenhang wurde auch das unterschiedliche Emissionsverhalten von Hardcopy-Geräten auf Grund der verschiedenen und nicht miteinander vergleichbaren Prüfverfahren heftig diskutiert. Aus diesen Gründen wurde ein neues Prüfverfahren entwickelt, mit dem eine verlässliche und reproduzierbare Prüfung der Emissionsraten von Staub, Ozon und flüchtiger organischer Verbindungen auf der Basis des ECMA (European Computer Manufacturer Association) Standards 328 möglich ist. Dazu wurden neun verschiedene Geräte unter verschiedenen Bedingungen untersucht. Als ein Ergebnis dieser Studie wurden neue Kriterien zur Vergabe des "Blauen Engels" für Kopierer, Drucker und Multifunktionsgeräte festgelegt.
Die Analytik von Phthalaten (DMP bis DEHP) in der Luft ist mit thermischer Desorption unter Verwendung von Quarzwolle als Adsorbens erfolgreich realisierbar. Dies wurde durch eine Methodenvalidierung bestätigt. Es wurden sowohl Messungen im Innenraum als auch in Emissionskammern vorgenommen. In den Emissionskammermessungen wurden mögliche Senkeneffekte der Kammeroberfläche (Glas) untersucht. Unter Zuhilfenahme der idealen Abklingkurve wird bestätigt, dass diese Oberfläche eine Senke darstellt.
Im Rahmen der Richtlinienarbeit der Kommission Reinhaltung der Luft im VDI und DIN - Normenausschuss KRdL wurde ein Ringversuch zur Validierung des Analysenverfahrens für Phthalate in der Innenraumluft durchgeführt. Dabei wurden die beiden in der künftigen Richtlinie beschriebenen Analysenverfahren der Thermodesorption von Adsorptionsröhrchen sowie der Lösemittelextraktion von Florisilröhrchen mit jeweils anschließender Gaschromatographie und Massenspektrometrie (GC/MS) erprobt. Die Ergebnisse des Ringversuchs belegen die Vergleichbarkeit der beiden Verfahren. Auch die Richtigkeit der Ergebnisse im Rahmen einer akzeptablen Streuung sowie die Praktikabilität in der Praxis konnten bestätigt werden. Weiterhin wurden wichtige Erkenntnisse zur Minimierung der Blindwerte erarbeitet.
Volatile organic compounds (VOCs) found indoors have the potential to affect human health. Typical sources include building materials, furnishings, cleaning agents, etc. To address this risk, chemical emission testing is used to assess the potential of different materials to pollute indoor air. One objective of the European Joint Research Project 'MACPoll' (Metrology for Chemical Pollutants in Air) aims at developing and testing a reference material for the quality control of the emission testing procedure. Furthermore, it would enable comparison of measurement results between test laboratories. The heterogeneity of the majority of materials makes it difficult to find a suitable reference sample.
In the present study, styrene, 2-ethyl-1-hexanol, N-methyl-α-pyrrolidone, lindane, n-hexadecane, 1,2-dimethyl- and 1,2-di-n-butyl-phthalate were added to 12 commercially available lacquers (6 alkyd and 6 acrylic polymer based lacquers) serving as carrier substrate. After homogenization, the mixtures were loaded into a Markes Micro-Chamber/Thermal Extractor (µ-CTE) for curing and investigation of the emission behavior for each compound. For almost all of the investigated chemicals, the preferred glossy acrylic lacquer showed emissions that were reproducible with a variation of less than 20% RSD. Such lacquer systems have therefore been shown to be good candidates for use as reference materials in inter-laboratory studies.
Odours might cause offensive nuisance and are under suspicion to be directly harmful to health. Surprisingly their assessment is by definition no part of the determination of indoor air quality (yet). As odours emit from building materials as well as from common consumer goods the users awareness increases continuously and demand for improved consumer protection raises. In comparison to well established methods for the determination of volatile organic compounds (VOC) in the air, there is little experience regarding the applicability, comparability and reproducibility of odour measurements. Considering this, the international and the German standardisation take into account odour assessment, e.g. ISO 16000-28 and VDI 4302-1.
In Germany the AgBB-Scheme is a mandatory tool for the evaluation of building products and it is intended to implement odour measurement into it. Initially and essentially the newly developed method had to be put to test involving institutes that deal with VOC measurements. To test the applicability of the method an interlaboratory test was conducted. The results and identified potential improvements are presented in this study (Brosig, 2013).
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap 300 (R) (a multi-bed tube using Carbopack C (R), Carbopack B (R) and Carbosive SIII (R)) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber.
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.
The aim of this study was the development of a low volume air sampling strategy for biocides and polychlorinated biphenyls (PCB) at low air change rates in modern, air-tight showcases as they are present in museums. Lindane, pentachlorophenol, dichlofluanid, tolyfluanid, isodrin, p,p-dichlorodiphenyl trichloroethane and permethrin were the biocides and PCB 28 and PCB 153 were the PCBs studied, all of which are semi volatile organic compounds (SVOC). Their occurrences in the museum environment originate from various sources e.g. preventive treatment of organic exhibits or organic building materials. Exhibits are long-term exposed to these pollutants due to storing in showcases or other storage equipment at low air change rates. To achieve air sampling under the aforementioned conditions the influences of temperature, air circulation, air change rate and relative humidity on the emission behavior of the selected biocides and PCBs had to be determined. This was carried out with pre-soaked wood samples in low volume air sampling experiments using 27 L test showcases and 23 L and 24 L emission test chambers and also diffusive sampling with glass as the sampling material.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Emissions of building materials might have negative impact on human health and well-being. In the EU-funded research project H-House more than 30 natural materials (earthen dry boards and plasters, bio-based insulation materials made of wood, flax, reed, straw, etc.) used for renovation and refurbishment were tested regarding emissions of VOC, formaldehyde and radon. Different to ordinary emission tests on single materials this study focuses on the emissions from complete wall assemblies. Therefore, specially designed test chambers were used allowing the compounds to release only from the surface of the material facing indoors. The testing parameters were chosen in order to simulate model room conditions. The emission results were finally evaluated using the AgBB evaluation scheme, a procedure currently applied for the approval of flooring materials in Germany.
Development of a multi-VOC reference material for quality assurance in materials emission testing
(2015)
Emission test chamber measurement is necessary to proof building materials as sources of volatile organic compounds (VOCs). The results of such measurements are used to evaluate materials and label them according to their potential to emit harmful substances, polluting indoor air. If only labelled materials were installed indoors, this would improve indoor air quality and prevent negative impacts on human health. Because of the complex testing procedure, reference materials for the quality assurance are mandatory. Currently, there is a lack of such materials because most building products show a broad variation of emissions even within one batch. A previous study indicates lacquers, mixed with volatile organic pollutants, as reproducible emission source for a wide range of substances. In the present study, the curing of the lacquer-VOC mixture inside micro-chambers was optimised. Therefore, the humidity and the chamber flow were varied. Typical indoor air pollutants with a wide range of volatilities, for example, styrene, n-hexadecane, dimethyl and dibutyl phthalate were selected. It turned out that, under optimised curing parameters inside the micro-chamber, their emission can be reproduced with variations of less than 10 %. With this, a next important step towards a reference material for emission testing was achieved.
Volatile Organic Compounds (VOC) are ubiquitous in the indoor air since they are emitted from materials used indoors. Investigations of these materials are mostly carried out in emission test chambers under controlled climatic conditions. Reference materials are an important tool for quality assurance/Quality control of emission test chamber measurements but so far they are not commercially available. In this study, a new approach was tested to develop an appropriate reference material with homogenous and reproducible emission of the VOC with well measurable air concentrations in emission test Chambers larger than 20 L at air change rates of 0.5 - 1 /h.
Thermoplastic Polyurethane (TPU) was selected as Matrix material which was impregnated with 2,2,4- trimethyl-1,3-pentanediol monoisobutyrate (texanol) as test VOC using compressed carbon dioxide. An optimization of the impregnation parameters such as temperature, pressure, time, VOC injection volume and TPU sample size was performed until the targeted area specific Emission rate (SERa) value was reached. Further aspects like process control, storage effects and correlation of the sample size to the emission rate were investigated. It was found that the SERa immediately after sample preparation were not reproducible between the batches but became unified 10 days after loading into the test chamber indicating the necessity of aging before use. SERa between 13,000 and 18,000 mg m-2 h-1 were obtained, and the impregnated materials could be well stored in aluminum-coated polyethylene foil for at least seven weeks without significant losses. Furthermore, the impregnation of styrene and the SVOC 2,6-diisopropylnaphthalene was tested.
Recent research into emissions of (semi-)volatile organic compounds [(S)VOC] from solid materials has focused on the development of suitable reference materials for quality assurance/quality control of emission test chamber measurements, which fulfill requirements such as homogenous and reproducible (S)VOC release. The approach of this study was to find a method for preparation of a material with predictable (S)VOC emission rates. AVOC (styrene) and an SVOC (2,6-diisopropylnaphthalene, DIPN), loaded into either vacuum grease or a 1:1 mixture of paraffin/squalane, have been tested. For the prediction of the emission rates, a model using the finite element method (FEM) was created to simulate the (S)VOC emission profiles. Theoretical and experimental results obtained in a Micro-Chamber/Thermal Extractor (μ-CTE™) and in 24 L emission test chamber measurements were in good agreement. Further properties were investigated concerning the material applicability, such as shelf life and inter-laboratory comparability. The maximum relative standard deviation in the inter-laboratory study was found to be 20%.
Emission testing of products is currently a rapidly increasing field of measurement activity. Labelling procedures for construction products are based on such emission test chamber measurements and hence measurement performance should be verified. A suited procedure for this purpose is the testing of one unique homogenous material in different laboratories within a Round Robin Test (RRT). Therefore, it is useful to have a reference material which can be used within inter-laboratory studies or as part of the quality management system to ensure comparable results. Several approaches on the development of reproducibly emitting materials have been published. These have in common only to emit a single VOC – toluene. Two further research studies carried out by BAM aimed to develop reference material for emissions testing containing one or more VOC in a single material. The first approach was a doped lacquer with Volatile and Semi-Volatile Organic Compounds (VOC/SVOC) and the second was Thermoplastic Polyurethane (TPU) or a Squalane/Paraffin mixture. Results received with the lacquer based material were presented in more detail.
Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt für Materialforschung und -prüfung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well-characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 µg/m3. This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 µg/m3. In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28 % in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51 %.
EN 16516 sets specifications for the determination of emissions into indoor air from construction products. Reliable, accurate and International System of Unit (SI)-traceable measurement results of the emissions are the key to consumer protection. Such measurement results can be obtained by using metrologically traceable reference materials. Gas-phase standards of volatile organic compounds (VOCs) in air can be prepared by a variety of dynamic methods according to the ISO 6145 series. However, these methods are not always applicable for semi-VOCs (SVOCs) due to their high boiling point and low vapour pressure. Therefore, a novel dynamic gas mixture generation system has been developed. With this system gas-phase standards with trace level VOCs and SVOCs in air can be prepared between 10 nmol mol−1 and 1000 nmol mol−1. The VOCs and SVOCs in this study have normal boiling points ranging from 146 °C to 343 °C. Metrologically traceable reference materials of the gas-phase standard were obtained by sampling of the VOC gas-phase standard into Tenax TA® sorbent material in SilcoNert® coated stainless steel tubes. Accurately known masses between 10 ng and 1000 ng per VOC were sampled. These reference materials were used to validate the dynamic system. Furthermore, the storage and stability periods of the VOCs in the reference materials were determined as these are crucial characteristics to obtain accurate and SI-traceable reference materials. In a round robin test (RRT), the reference materials were used with the aim of demonstrating the feasibility of providing SI-traceable standard reference values for SVOCs for interlaboratory comparison purposes. Based on the results from the validation, the storage and stability studies and the RRT, gas-phase standards and reference materials of VOCs and SVOCs with relative expanded uncertainties between 5% and 12% (k = 2) have been developed. These reference standards can be used as calibrants, reference materials or quality control materials for the analysis of VOC emissions.
Bauprodukte und Einrichtungsgegenstände für Innenräume, wie Bodenbeläge und Wandpaneele, sollen das Wohlbefinden und die Gesundheit der Raumnutzerinnen und -nutzer nicht durch das Ausdünsten von Geruchsstoffen stören. Mit der Geruchsprüfung nach ISO 16000-28 „Innenraumluft - Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ wird der Produktgeruch zu einer messbaren Größe. So kann z. B. die empfundene Intensität, also die Stärke eines Geruchseindruckes, mit Hilfe eines Vergleichsmaßstabes von Probandinnen und Probanden ermittelt werden. Im hier vorgestellten Projekt werden Vorschläge zur Weiterentwicklung der Methode vorgestellt, um im Ergebnis die Reproduzierbarkeit der Messergebnisse weiter zu verbessern. Dabei werden vor allem das Probenpräsentationssystem und die Bewertungsmethodik für die empfundene Intensität bei der Bewertung von Bauprodukten gemäß AgBB-Schema betrachtet, da diese einen wesentlichen Einfluss haben.
Die im Oktober 2001 erschienenen Dämmstoffnormen der 1. Generation DIN EN 13162 (Mineralwolle), DIN EN 13163 (EPS) und folgende (bis DIN EN 13171) verlangen vom Hersteller einen initial type test (ITT) von einer notifizierten Prüfstelle - nicht nur für bauphysikalische Eigenschaften wie den Wärmedurchgangswiderstand - sondern auch für die Freisetzung gefährlicher Substanzen. In den Normen wird allerdings noch auf nationale Regelungen verwiesen, da entsprechende Erfahrungen mit europäischen Prüfverfahren nicht vorliegen - auch nationale Erfahrungen liegen nur sehr eingeschränkt vor. Deshalb ist die Entwicklung eines kostengünstigen und praxisrelevanten Prüfverfahrens zur Bestimmung der Emissionen aus Dämmstoffen von normativem Interesse. Es konnte gezeigt werden, daß das Emissionsprüfzellenverfahren (FLEC mit Subunit) gemäß DIN V ENV 13419-2 vergleichbare Ergebnisse wie das aufwendigere 1-m3-Prüfkammerverfahren gemäß DIN V ENV 13419-1 liefert und damit als Erstprüfverfahren fungieren könnte.
Geruchsintensität und Emissionen von Bauprodukten - Vorstellung des Verfahrens und Laborvergleich
(2007)
Die Bewertung von VOC-Emissionen aus Bauprodukten soll durch das AgBB-Schema vereinheitlicht werden und eine gesundheitsrelevante Komponente enthalten. Das Deutsche Institut für Bautechnik (DIBt) hat das AgBB-Schema in weiten Teilen für seine Grundsätze zur gesundheitlichen Bewertung von Bauprodukten in Innenräumen implementiert. Neben der üblichen chemischen Emissionsmessung soll auch der Geruch für die Bewertung des Produkts herangezogen werden. Um den Geruch als festen Bestandteil in die Produktprüfung zu integrieren, wurden vom Umweltbundesamt zwei Vorhaben initiiert. Erste Ergebnisse des zweiten Vorhabens (FKZ 37 07 62 300; Sensorische Bewertung der Emissionen aus Bauprodukten Integration in die Vergabegrundlagen für den Blauen Engel und das Bewertungsschema des Ausschusses zur gesundheitlichen Bewertung von Bauprodukten) werden hier dargestellt.
Unterschiedliche Befeuchtungssysteme für Vitrinen, die die Ausstellungsobjekte bei definierter Luftfeuchtigkeit vor externen Einflüssen wie Staub bewahren sollen, wurden im Hinblick auf die Möglichkeit der potenziellen mikrobiologischen Kontamination untersucht. Ergänzend hierzu wurden Parameter wie pH-Wert und Leitfähigkeit des Wassers im Befeuchter untersucht und die mikrobiellen flüchtigen organischen Verbindungen (MVOC, microbial volatile organic compounds) in der Modellvitrine bestimmt. Die Leitfähigkeitsmessung kann als Indikator für den Verunreinigungsgrad des Wassers dienen, weil sie mit der mikrobiologischen Belastung korreliert. Weiterhin war eine mikrobiologische Belastung der Luft in der Modellvitrine auch bei relativ hoher Verunreinigung des Befeuchtungswassers nicht nachzuweisen.
Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography mass spectrometry/mass spectrometry).
Natural building materials for interior fitting and refurbishment - What about indoor emissions?
(2021)
Indoor air quality can be adversely affected by emissions from building materials, consequently having a negative impact on human health and well-being. In this study, more than 30 natural building materials (earth dry boards and plasters, bio-based insulation materials, and boards made of wood, flax, reed, straw, etc.) used for interior works were investigated as to their emissions of (semi-) volatile organic compounds ((S)VOC), formaldehyde, and radon. The study focused on the emissions from complete wall build-ups as they can be used for internal Partition walls and the internal insulation of external walls. Test chambers were designed, allowing the compounds to release only from the surface of the material facing indoors under testing Parameters that were chosen to simulate model room conditions. The emission test results were evaluated using the AgBB evaluation scheme, a procedure for the health-related evaluation of construction products and currently applied for the approval of specific groups of building materials in Germany.
Seventeen out of 19 sample build-ups tested in this study would have passed this scheme since they generally proved to be low-emitting and although the combined emissions of multiple materials were tested, 50% of the measurements could be terminated before half of the total testing time.
Cellulose ethers, like methyl cellulose (MC) or hydroxypropyl cellulose (HPC), are widely used in conservation. They also occur as additives and rheology modifiers in various products like dispersions or gels. Do such products release harmful volatile organic compounds (VOC) during their accelerated aging? A mass testing series utilizing the Oddy test of 60 commercial cellulose ethers ranks the products in safe for permanent use (P, no corrosion), only for temporary use (T, slight corrosion), and unsuitable at all (F, heavy corrosion). Results show that 55% of the products passed the test whereas 33% are for temporary use as slight corrosion occurred on at least one metal coupon and only 11% failed the Oddy test. Raman measurements of the corrosion products identified oxides like massicot, litharge, cuprite, and tenorite among carbonates (hydrocerussite, plumbonacrite), and acetates like basic lead acetate, lead acetate trihydrate as well as lead formate as main phases. For example, commercial, industrial Klucel® G (HPC) scored a T rating through slight corrosion on the lead coupon. Basic lead acetate among other phases indicates the presence of acetic acid. Additional measurements of the sample with thermal desorption GC–MS utilizing the BEMMA scheme confirm the high acetic acid outgassing and reveal the presence of a small amount of formaldehyde.