Do particleboards produced with recycled wood contribute to indoor air pollution with biocides?
(2003)
The European biocides directive (98/8/EG) demand the control of emissions into the envi-ronment like soil, water and air. In this study a method for measuring the input of biocides into the indoor air from materials should be developed. The emission of two products containing biocides (plastic foil, wool carpet) and six different types of biocide containing formulations applied on wood or ceramic tiles were investigated in 20 or 23 l glass emission chambers. Each chamber test was performed over a period of 100 up to 200 days. SVOC show totally different emission curves in chamber tests compared to volatile organic com-pounds (VOC). They reach their maximum value after some days or weeks. Thus a period of 3 months is sometimes necessary for exact measurements. Area specific emission rates (SERa in µg/m²h) for permethrin (0.006), propiconazole (0.2), dichlofluanid (1.5), tolylfluanid (1.2), octylisothiazolinone (2.5) and for iodpropinylbutyl-carbamat (1.7) were determined.
Do Particleboards produced with recycled wood contribute to indoor air pollution with biocides?
(2003)
Biocides are used to protect materials that might be damaged by fungal, microbial or insect activity. The aim of this study is to develop a method for the measurement of these organic compounds, which generally have low or moderate vapor pressures. The biocides considered in this study are permethrin, dichlofluanid, tolylfluanid, iodpropinylbutylcarbamat, octylisothiazolinone, tebuconazole and propiconazole. The emission from two commercial products (plastic foil, wool carpet) containing biocides and of seven types of biocidal formulations applied to wood or clay tiles were investigated in 20-l glass emission test chambers. Each chamber test was performed over a period of 100200 days, and one investigation was conducted over several years. Compared to volatile organic compounds, low-volatility compounds show totally different emission curves in chamber tests; maximal emission values may be reached in days or weeks. A period of 3 months is sometimes necessary for the determination of area-specific emission rates (SERa's). The SERa's (?g m-2 h-1) from biocide-containing products were determined for permethrin (0.006), propiconazole (0.3), dichlofluanid (2.0), tolylfluanid (1.0), octylisothiazolinone (2.5) and iodpropinylbutylcarbamat (2). In most cases, the SERa stayed at its maximum value or declined slowly over the test period. Additionally, a chamber test begun in 1994 with a piece of wood treated with a typical mixture of biocides dissolved in a technical solvent was continued. SERa's (?g m-2 h-1) for dichlofluanid (0.20), tebuconazole (0.49) and permethrin (0.08) remained detectable after the period of nearly 9 years during which the sample remained continuously in the chamber. This test proved the very slow decrease of emission of low-volatility compounds like permethrin and tebuconazole.
Using the AgBB evaluation scheme for VOC and odour emissions of different construction products
(2006)
Methods for the determination of biocide emissions from treated materials into water and air were developed and tested in order to support a comparative ecological assessment of biocidal products. Leaching tests, experiments with simulated rain, extraction cleaning of carpets and emission chamber tests were performed with a series of treated materials. The experiments focused on the effect of changes in the procedure as well as characteristics of the specimens and demonstrate the suitability of the proposed methods for biocides of different product types.
It was demonstrated that emissions of biocides into water can be compared on the basis of leaching tests in which the emission kinetics of the active ingredients are recorded. However, the water volume per surface area and the timetable for water changes have to be defined in such tests. Functions of flux rates related to time can be well described for inorganic compounds, whereas modelling of the data is more complicated for organic substances.
Emission chamber tests using 20-litre and 23-litre glass exsiccators, originally developed to study volatile organic compounds, were successfully adapted for the investigation of the emission of biocides from treated materials which are usually semi volatile organic compounds. However, test parameters and the method of analysis have to be adapted to the substances to be determined.
Generally, it was found that the emission curves for the semi volatile organic compounds investigated differ from those of volatile organic compounds.
An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unterschiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden. Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL UZ 62, RAL UZ 85 sowie des neuen RAL UZ 114 für Multifunktionsgeräte darstellt.
Kurzfassung An neun verschiedenen Hardcopygeräten wurden in unterschiedlichen Emissionsmesskammern (zwei verschiedene 1 m³ - Kammern und eine 20 m³ - Kammer) in Kombination mit geeigneten Probenahme- und Analysenverfahren Untersuchungen zum Emissionsverhalten dieser Geräte hinsichtlich Staub, Ozon und VOC (TVOC) durchgeführt. Luftprobenahme und Analytik erfolgten für VOC mittels Tenax TA und anschließender Thermodesorption (TDS) in Verbindung mit GC / MS. Ozon wurde kontinuierlich bestimmt. Der Ozonanalysator arbeitete auf der Grundlage der flammenlosen Reaktion von Ozon mit Ethylen nach dem Prinzip der Chemilumineszenz. Die Staubbestimmung erfolgte gravimetrisch mittels Glasfaserfilter und Ultramikrowaage. Zusätzlich wurde die Partikelemission während des Druckbetriebes mit einem Partikelzähler bestimmt. Aufgrund der technischen Rahmenbedingungen standen nur kurze Druckzeiten von maximal 36 Minuten zur Verfügung. Um die Gleichgewichtskonzentration in der Prüfkammer zu erreichen, wurde die Luftaustauschrate in den 1 m³ - Kammern auf n = 4,0 bis 4,7 pro Stunde erhöht. Zusätzlich zur Prüfung in den Emissionsmesskammern sind verschiedene Papiere mittels Direkt - TDS sowie unter- schiedliche Toner mittels Headspaceprobenahme in Kombination mit GC / MS hinsichtlich ihres Emissionsverhaltens untersucht worden.
Für die untersuchten Geräte wurden Emissionsraten ermittelt. Sie betrugen für TVOC 0,41 bis 22,4 mg pro Stück und Stunde, für Ozon kleiner 0,02 bis 4,6 mg pro Stück und Stunde sowie für Staub 0,10 bis 7,63 mg pro Stück und Stunde. Verglichen mit Frischfaserpapier wurden bei den Untersuchungen mit Recyclingpapier deutlich höhere SVOC - Konzentrationen nachgewiesen. Im Ergebnis der Untersuchungen wurde ein Prüfverfahren entwickelt, das die Basis für Emissionsmessungen im Rahmen der Umweltzeichen RAL UZ 62, RAL UZ 85 sowie des neuen RAL UZ 114 für Multifunktionsgeräte darstellt. Abstract The emission behaviour with regard to dust, ozone and VOC (TVOC) of nine different hardcopy devices in combination with suitable air sampling and analysis procedures was investigated in different emission test chambers (two different 1 m³ - chambers and one 20 m³ - chamber). Air sampling and analysis for VOC were done by means of Tenax TA and subsequent thermal desorption (TDS) in connection with GC / MS. Ozone was determined continuously. The ozone analyser worked on the basis of the flame rid reaction of ozone with ethylene according to the principle of chemiluminescence. The dust determination was done gravimetrically by means of glass fibre filter and an ultra micro - balance. Additional the particle emission during the printing process was measured with a particle counter. The general technical conditions of the tested hardcopy devices were the reason for short printing times with a maximum of 36 minutes. In order to achieve the equilibrium concentration in the test chambers the air exchange rate in the 1 m³ - test chambers had to be increased to a value of n = 4,0 to 4,7 per hour. Additional to the examination of the hardcopy devices in the emission test chambers different papers were investi- gated by means of direct - TDS and different toners were tested by means of head space sampling in combination with GC / MS. For the examined hardcopy devices emission rates were determined. The emission rates for TVOC ranged from 0,41 to 22,4 mg per piece and hour, for ozone from less than 0,02 to 4,6 mg per piece and hour and for dust from 0,10 to 7,63 mg per piece and hour. The comparison between recycling paper and paper produced from primary fibres showed in general higher SVOC emissions from recycling paper. As the result of the investigations a test method for the determination of emissions from hardcopy devices was developed. This test method is the basis for emission tests in the framework of the German Award of the Environmental Label for office devices RAL -UZ 62, RAL -UZ 85 and the new RAL -UZ 114 for multifunctional devices.
Background to the studies was the revision of the current selection criteria of the German ecolabel Blauer Engel (Blue angel) for copiers and printers. In the requirements limits were set for ozone, dust and styrene emissions. The former test methods did no longer correspond to todays requirements with regard to emission measurements. In addition, the emission behaviour of hardcopy devices due to the use of different and non-com parable test methods has been recently discussed controversely. For this reason a new test method had to be developed which enables a reliable, reproducible determination of emission rates (ER) for dust, ozone and VOC (volatile organic compounds). The basis for this was the ECMA-Standard 328 compiled by ECMA (European Computer Manufacturer Association) using dynamic chamber measurements. Nine different machines, desktop laser printers as well as office devices like bigger copiers and multifunctional devices were investigated. As a result of the study new criteria for the Blauer Engel for copiers, printers and a new created for multifunctional devices, concerning TVOC, ozone and dust emission were determined. Additionally a model is presented calculating the concentrations in real rooms under usual printing conditions derived from the test chamber results.
Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography mass spectrometry/mass spectrometry).
The development of a gas mixing system (GMS) that enables dynamic and retraceable production of stable long-term VOC gas mixtures within the ppb range is discussed. In this system pure liquid substances are kept separately at a constant temperature, evaporated according to their vapour pressure and removed by a small inert gas flow. A modular set-up allows flexible handling. All vapours generated are finally united in a mixing chamber. Any concentration level of the gas mixture can be produced by a suitable combination of evaporation temperature, carrier and dilution gas flows. Test results from continuous operation over six weeks are presented. The equipment was tested on seven volatile organic compounds (VOC) of different vapour pressure ranges. It was possible to establish stable operation for the equipment during the entire period and reproducible gas concentrations which were traceable to the mass as an SI unit, thus the system is suitable for long-term tests.---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Im Beitrag wird die Entwicklung eines Gasmischsystems (GMS) beschrieben, das die dynamische und rückführbare Generierung von langzeitstabilen VOC-Gasgemischen im ppb-Bereich erlaubt. Dabei werden Reinsubstanzen separat temperiert, ihrem Dampfdruck entsprechend verdampft und durch einen kleinen Inertgasstrom abgeführt. In einer Mischkammer werden sie schließlich zusammengeführt. Durch die Kombination von Verdampfungstemperatur, Träger- und Verdünnungsgasflüssen ist die Einstellung eines beliebigen Konzentrationsniveaus des Gasgemischs möglich. Aus einem Dauerbetrieb von sechs Wochen werden Untersuchungsergebnisse gezeigt. Dabei wurde die Apparatur mit insgesamt sieben flüchtigen organischen Verbindungen (VOC) unterschiedlicher Dampfdruckbereiche betrieben. Die Anlage lief über den gesamten Zeitraum stabil und lieferte reproduzierbare und auf die Masse als SI-Einheit rückführbare Gaskonzentrationen. Somit ist das Verfahren für Langzeitanwendungen geeignet.
Since semi-volatile organic compounds (SVOCs), including biocides and polychlorinated biphenyls (PCBs), occur indoors as well as outdoors, air sampling adsorbents and measuring methods for all these compounds are indispensable. This paper presents the initial steps in the development of such a method, the aim of which is the analysis of selected compounds in the above-mentioned classes using low air sampling volumes and air-exchange rates close to zero, as is common in museum showcases. For measurements under easily controlled conditions, a micro-chamber system was used at different temperatures. A surface modified styrene divinylbenzene (SDVB) polymer was selected as the air sampling adsorbent for the elution experiments. After successfully performing pretests using the micro-chamber system with target compound solutions, the emissions of these compounds from self-soaked wood samples and con-taminated wood samples were investigated for method development.
Emissions from building products can considerably impair the quality of indoor air. The AgBB scheme is employed to evaluate the emissions of volatile organic compounds (VOC) from building products. The hygienic evaluation according to the AgBB scheme requires product-specific measuring procedures.
These are available for a range of products. They have been validated in co-operation with several research and testing institutes and have been included in the criteria for awarding the Blue Angel ecolabel.
The evaluation is, however, stricter and generally has lower limits. VOC emissions and odours can cause health problems so testing using sensors is an important element in the evaluation of building products and has – for reasons of precaution – been set down in the AgBB scheme. The main goal of the project was to derive a method of evaluation using sensors and limits for awarding the Blue Angel and for the AgBB scheme. Based on the research conducted (see Chapter 5 Results and Discussion), perceived intensity and hedonics were suggested as a suitable Evaluation method. The derivation of limits for the evaluation using sensors on the 28th day was effected in the present study through the additional questioning of the test subjects on the reasonability of a sample.
For the Blue Angel, there could be different limits of perceived intensity and hedonics for each group of products. A preliminary suggestion for possible limits – for all product groups – is a perceived intensity of 7 pi (5 pi + 2 pi as confidence coefficient, Chapter 5.1.5) and -1 (0+/-0.8, rounded to -1) for the hedonic value.
Messung und Bewertung von Gerüchen aus Bauprodukten für den Innenraum gewinnen vor allem durch den zunehmenden Bau energieeffizienter Gebäude an Bedeutung. Intensive und unangenehme Gerüche werden von Bewohnerinnen, Bewohnern und Angestellten nicht akzeptiert und können auf Dauer krank machen. Bislang stand noch kein allgemein anerkanntes Messverfahren zur Verfügung. Dieses wurde nun in Forschungsprojekten entwickelt, wobei auch konkrete Bewertungsvorschläge zur Zumutbarkeit von Gerüchen gemacht wurden. Das Verfahren ist an die Messung der Emissionen flüchtiger organischer Verbindungen aus Bauprodukten gekoppelt und nutzt Probanden, um die Geruchsstärke (Intensität) und den Geruchseindruck (Hedonik) zu ermitteln. In der Praxis wird das Verfahren nun an verschiedenen Stellen erprobt. Die Bewertung der Geruchsemissionen gibt der Industrie die Möglichkeit, geruchsarme Produkte zu gestalten. Die Kennzeichnung geruchsarmer Bauprodukte mit dem Umweltzeichen Blauer Engel erleichtert Verbraucherinnen und Verbrauchern die Orientierung beim Einkauf.
Unterschiedliche Befeuchtungssysteme für Vitrinen, die die Ausstellungsobjekte bei definierter Luftfeuchtigkeit vor externen Einflüssen wie Staub bewahren sollen, wurden im Hinblick auf die Möglichkeit der potenziellen mikrobiologischen Kontamination untersucht. Ergänzend hierzu wurden Parameter wie pH-Wert und Leitfähigkeit des Wassers im Befeuchter untersucht und die mikrobiellen flüchtigen organischen Verbindungen (MVOC, microbial volatile organic compounds) in der Modellvitrine bestimmt. Die Leitfähigkeitsmessung kann als Indikator für den Verunreinigungsgrad des Wassers dienen, weil sie mit der mikrobiologischen Belastung korreliert. Weiterhin war eine mikrobiologische Belastung der Luft in der Modellvitrine auch bei relativ hoher Verunreinigung des Befeuchtungswassers nicht nachzuweisen.
Emissionen aus Bauprodukten beeinträchtigen die Qualität der Innenraumluft erheblich. Mit Hilfe des AgBB-Schemas werden die Emissionen flüchtiger organischer Verbindungen (VOC) aus Bauprodukten bewertet. Die gesundheitliche Bewertung nach dem AgBB-Schema erfordert produktspezifische Messverfahren.
Diese gibt es mittlerweile für eine Reihe von Produkten. Sie wurden durch Beteiligung verschiedener Forschungseinrichtungen und Messinstitute validiert und u. a. in die Vergabekriterien des Umweltzeichens Blauer Engel übernommen. Die Bewertung ist allerdings mit zumeist niedrigeren Grenzwerten strenger. VOC-Emissionen und Gerüche können beide zu gesundheitlichen Belastungen führen. So ist die sensorische Prüfung ein weiteres wichtiges Element bei der Bewertung von Bauprodukten und vorsorglich auch im AgBB-Schema verankert.
Hauptziel des Projektes ist es, eine Methode der sensorischen Bewertung und Grenzen für die Vergabe des Blauen Engels und für das AgBB-Schema abzuleiten. Auf Grundlage der durchgeführten Untersuchungen (siehe Kapitel 5 Ergebnisse und Diskussion) wird als Bewertungsmethode die empfundene Intensität und die Hedonik vorgeschlagen. Die Ableitung der Grenzwerte für die sensorische Bewertung am 28. Tag erfolgt über die zusätzliche Befragung der Probanden im Rahmen der vorliegenden Studie nach der Zumutbarkeit einer Probe.
Für den Blauen Engel könnte es je Produktgruppe unterschiedliche Grenzen der empfundenen Intensität und der Hedonik geben. Ein erster Vorschlag für mögliche Grenzen, hier zunächst einheitlich für alle
Produktgruppen, ist für die empfundene Intensität 7 pi (5 pi + 2 pi als Sicherheit, Kapitel 5.1.5) und für die Hedonik -1 (0 +/-0,8, gerundet auf -1) (siehe dazu Abbildung 6-2).
Schadstoffe beschäftigen derzeit Museen weltweit Heute weiß man, dass diese auch aus Materialien, die für den Ausstellungsbau verwendet werden, austreten können, was eine Gefahr für Exponate darstellt. Ein neues Verfahren namens BEMMA bietet nun erstmalig die Möglichkeit, relativ schnell und effektiv eine problemorientierte Untersuchung und Bewertung mit belastbaren und reproduzierbaren Ergebnissen vorzunehmen.
Die im Oktober 2001 erschienenen Dämmstoffnormen der 1. Generation DIN EN 13162 (Mineralwolle), DIN EN 13163 (EPS) und folgende (bis DIN EN 13171) verlangen vom Hersteller einen initial type test (ITT) von einer notifizierten Prüfstelle - nicht nur für bauphysikalische Eigenschaften wie den Wärmedurchgangswiderstand - sondern auch für die Freisetzung gefährlicher Substanzen. In den Normen wird allerdings noch auf nationale Regelungen verwiesen, da entsprechende Erfahrungen mit europäischen Prüfverfahren nicht vorliegen - auch nationale Erfahrungen liegen nur sehr eingeschränkt vor. Deshalb ist die Entwicklung eines kostengünstigen und praxisrelevanten Prüfverfahrens zur Bestimmung der Emissionen aus Dämmstoffen von normativem Interesse. Es konnte gezeigt werden, daß das Emissionsprüfzellenverfahren (FLEC mit Subunit) gemäß DIN V ENV 13419-2 vergleichbare Ergebnisse wie das aufwendigere 1-m3-Prüfkammerverfahren gemäß DIN V ENV 13419-1 liefert und damit als Erstprüfverfahren fungieren könnte.
Messung der empfundenen Geruchsintensität mit Multigas-Sensorsystemen, das Forschungsvorhaben SysPAQ
(2007)
Möglichkeiten und Grenzen der Bewertung und Kennzeichnung geruchsarmer Bauprodukte und Einrichtungen
(2007)