VOC emissions from building materials accompanying sensory tests for different evaluation schemes
(2011)
Within a follow up project of a former study (Horn et al. 2005) emissions and odor from different types of construction products were investigated (financed by the German Federal Environmental Agency - FKZ 37 07 62 300).
The tested materials were mainly those used for construction of floors indoors. For this type of materials in Germany several labeling procedures exist which are based on Emission chamber testing. Two important labeling procedures in Germany are based on the AgBBevaluation scheme (Däumling et al. 2005). For some applications (flooring material) it is the mandatory Ü-mark of DIBt (German Institute for Construction Technology). Furthermore for carpets, adhesives and many other products, like sealants, mattresses, furniture and so on the voluntary blue angel mark exist. Within this scheme the volatile organic compounds (VOC) compounds are measured with well established procedures and are evaluated with LCI-values which were derived from health information.
Beyond that many complaints according to building products are caused by odors. Therefore an evaluation procedure for the odor is very important and should be implemented into all of the mentioned labeling schemes.
Quality and trueness of results received from measurements are very important for all involved parties, producers and consumers as well; for instance, if the results were used for acceptance of a product within a labeling procedure. Based on an inter-laboratory study with many German, European and US-American laboratories an extemal quality assurance System for the analysis of VOC emitting from products or the measurement in indoor air should be implemented (financed by the German Federal Environmental Agency).
A focus was set on the emission test chamber experiments and the connected analytical procedure. VOC have a dominating influence when applying the German AgBB scheme for health evaluation of building products.
Therefore it is necessary to ensure that the results between the testing laboratories are comparable. The successful participation to such round robin tests is offen essential for the acceptance of results given by an analytical laboratory.
The labelling of construction products or building materials as “low-emitting” is based on measurements using third-party emission test chambers. Unfortunately there is no method to validate the performance of such test chamber measurements. This might give a Variation of results when testing one material at different laboratories. Therefore it is necessary to hold round robin tests as part of the quality management System to ensure comparable results.
A research project financed by the Federal Environmental Agency focused on the development of an external quality management System for the detection of relevant Chemical compounds from products and in ambient air. The project was structured in four phases (Horn et al., 2009 and 2011; Wilke et al., 2009a) This paper shows results of the fourth phase of the project, which was an inter-laboratory study for VOC-emission testing by means of emission test chambers.
Unterschiedliche Befeuchtungssysteme für Vitrinen, die die Ausstellungsobjekte bei definierter Luftfeuchtigkeit vor externen Einflüssen wie Staub bewahren sollen, wurden im Hinblick auf die Möglichkeit der potenziellen mikrobiologischen Kontamination untersucht. Ergänzend hierzu wurden Parameter wie pH-Wert und Leitfähigkeit des Wassers im Befeuchter untersucht und die mikrobiellen flüchtigen organischen Verbindungen (MVOC, microbial volatile organic compounds) in der Modellvitrine bestimmt. Die Leitfähigkeitsmessung kann als Indikator für den Verunreinigungsgrad des Wassers dienen, weil sie mit der mikrobiologischen Belastung korreliert. Weiterhin war eine mikrobiologische Belastung der Luft in der Modellvitrine auch bei relativ hoher Verunreinigung des Befeuchtungswassers nicht nachzuweisen.
Vor dem Hintergrund der anhaltenden öffentlichen Diskussion um mögliche gesundheitliche Risiken von Ultrafein- und Feinstaubemissionen aus Bürogeräten mit Laserdruckfunktion (LPD, Laser Printing Device) wurde vom Umweltbundesamt ein Forschungsvorhaben zur Entwicklung einer Prüfprozedur für die Quantifizierung der emittierten Partikel durch Zählung unter Standardbedingungen in Emissionsmesskammern, sowie zur physikalischen und chemischen Charakterisierung dieser Aerosole initiiert. Als Ergebnis konnte die Partikelzählung in den Entwurf des Prüfverfahrens für die Bestimmung von Emissionen (RAL-UZ-122, Anhang S-M) des Umweltzeichens "Blauer Engel" für Bürogeräte sowie in den Prüfstandards ECMA-328 und den Entwurf der ISO/IEC 28360 integriert werden. Die Methode wurde in einem internationalen Ringversuch erfolgreich getestet. Auf dieser Basis können Vergabekriterien und -werte für die Emission von Fein- und Ultrafeinpartikeln im Rahmen der Vergabe des Umweltzeichens Blauer Engel vereinbart und Produktprüfungen vorgenommen werden.