Sensors for assessment of the structure’s behaviour must work durably and reliably. Even if the performance of produced and delivered sensor is well specified, the sensor's strain characteristics and the performance of an applied sensor can significantly differ from the virgin sensor’s performance. The quality and appropriateness of installation decides over the long-term operability and getting reliable measurement results. The paper shows how important a clear terminology is, which problems might occur when sensor are not well characterized according to Standards or guidelines. Short outlook to experimental methods providing clear knowledge and appropriate Validation of the sensor’s performance for a defined measurement task is given. Finally, the state of-the-art in fibre-optic sensor Standardization is given.
Measurement and data recording systems are important parts of a holistic Structural Health Monitoring (SHM) system. They are often based on modern measurement and data communication technologies for which standards (or at least guidelines) do not exist yet. A lack in standardization, however, makes the establishment of new sensing and application technologies - and thus up-to-date SHM systems - substantially difficult. Successful commercialization and wide acceptance of SHM systems needs widely accepted standards and guidelines. Standards help to design SHM systems in an optimal way. Currently, standardization gets increasing attention in civil engineering field; there are some activities e.g. in ISHMII, IEC and ISO groups to develop standards for the most important components of SHM systems.
The paper gives an overview on current activities in standardization to propose sound and safe procedures for assessment of the existing structure's behavior and for estimation of its residual life. Special attention is paid in this paper to newly developed standards for fiber-optic measurement systems; important aspects of such sensor systems are mentioned.
The contribution is aimed at owners of structures that have to be assessed as well as at developers of sensors and monitoring systems who have to select appropriate effective sensing technologies. Using standards, both parties find recommendations how to proceed in development SHM systems to estimate the design or residual life, and how to find out the optimal maintenance strategy. The usefulness of standardized procedures is shown using the example of risk-based management of structures.
Partial discharge in polymeric insulation of high voltage equipment causes cumulative damage that progressively deteriorates the insulation, leading to eventual failure. The electrical detection of related discharge current pulses may be challenged by electromagnetic interference from the environment. In such situations the detection of acoustic emission from partial discharge can greatly enhance its detectability, especially when electromagnetically immune fiber-optic acoustic sensors are used. During experiments involving such fiber-optic sensors that were specifically designed for the detection of partial discharge in elastomeric insulation, an unexpected type of acoustic emission was observed in silicone elastomer specimens with tip–plate electrode configurations and under DC electrical stress. We present and discuss experimental results that indicate space charge injection and subsequent spontaneous dynamical processes as the source of the detected acoustic emission. We use sensitive conventional partial discharge measurement instrumentation to show that the apparent acoustic efficiency of the processes leading to the observed acoustic emission is very high. Acoustic emission triggered by discharge events with individual apparent charge values of only a few femtocoulombs could be detected.
Movements in geological areas are often caused by shear zones deep in the underground or by hardly observable slipping zones. Detection of movements reaching critical values is of crucial importance to avoid losses and harms. Optical sensor fibers with gauge lengths of several meters or even distributed fiber-optic sensors with gauge lengths of hundreds of meters allow detecting deformation of such zones with quite good resolution. The paper presents a new technology of detecting deformations and movements in soil or rock massifs. The core part of the sensing system is a tiny pultruded rod with an outer diameter of 3 mm to 6 mm. It contains two fiber-optic sensor systems. One sensor system is used for permanent online measurement and provides integral strain information along the whole length of the rod; in case of critical deformations, it provides a warning signal. The second sensing system uses fiber-optic Bragg grating (FBG) strain sensors located close to the expected shear zone. This measurement system will be activated after the warning signal has been initiated by the integral strain measurement system. The FBG strain sensor system records then resulting deformations in detail. The sensing rod containing both sensor systems can be installed in a borehole to detect beginning soil movements automatically. The electronic equipment is powered by a solar panel; the amount of deformation in soil or rock formations can be estimated from the strain change measured in the sensor fibers. The effectiveness of this warning system will be shown using the example of a critically sliding slope in an open brown coal pit in Germany.
Standardization in fibre-optic sensing for structural safety - activities in the ISHMII and IEC
(2015)
Fiber-optic sensors are increasingly established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations to enhance the operational performance of aged structures or to monitor the structural behavior of safety-relevant structures or their components. However, there are some barriers in use due to a lack of extensive standardization of fiber-optic sensors. This leads very often to restraints in the users community. The paper shows the status in international standardization of fiber-optic sensors as well as current activities in leading institutions such as IEC and ISHMII and others with the purpose of providing relevant standards for a broader use of selected fiber-optic sensor technologies.