Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (61)
- Beitrag zu einem Tagungsband (20)
- Beitrag zu einem Sammelband (19)
- Forschungsbericht (2)
- Sonstiges (1)
Schlagworte
- NEXAFS (13)
- Plasma polymerization (9)
- XPS (7)
- Plasma (6)
- ToF-SIMS (5)
- ESCA/XPS (4)
- Ageing (3)
- Allyl alcohol (3)
- Oberflächenanalyse (3)
- Polyethylene (PE) (3)
Organisationseinheit der BAM
Die Bewertung der wasserstoffbeeinflußten Kaltrißneigung mit der Implant-, TRC- und Lehigh-Probe
(1980)
NEXAFS analysis of a plasma treated, partially crystalline poly(ehtylene terephtalate) surface
(1996)
Self-assembled octadecyltrichlorosilane (CH3(CH2)17SiCl3, OTS) films were deposited on an oxidized silicon wafer. They were carefully exposed to a low-pressure oxygen direct current (dc) plasma and/or Cr vapor. Subsequently, they were characterized by X-ray photoelectron spectroscopy, near-edge X-ray absorption fine structure spectroscopy, and atomic force microscopy. Detailed information on the oxygen functionalization and the molecular conformation of the OTS films was obtained. The main result was that functionalization conditions can be found where the order of the film remains almost unaffected. Similarly, Cr evaporation of pure OTS films revealed only slight effects on the order in the film. Cr evaporation of an ordered but functionalized OTS film immediately changes its state toward a fully isotropic one. In the course of interaction, oxygen sites at the surface of the functionalized OTS film are reduced whereas Cr becomes oxidized. A redox reaction scheme is proposed for this interfacial reaction. Finally, it is concluded that the given study should be of importance for advanced plasma processing of polyolefins.
Organic thin films with defined chemical structures and physical properties are required for various applications. Plasma polymerization is of technological interest, since the deposition of plasma polymers is possible on any material of any shape in the desired thickness. We report on the TOF-SIMS (TOF: time-of-flight) and XPS investigations of pulse plasma poly(acetylene) and alkali metal doped pulse plasma poly(acetylene) films. The combination of TOF-SIMS and XPS supplies detailed information on the surface chemistry of these films. Application of both methods provides the possibility for cross-checking certain results. Moreover the different sensitivities of the methods can be utilized. According to the TOF-SIMS and XPS data it can be concluded that the interaction of alkali metals with plasma poly(acetylene) results in electrovalent bonds of the type Me?+C?- between carbon and metal. Furthermore carbonoxygenmetal interactions were observed. These interactions are of the type C=O?-cdots, three dots, centeredMe?+ and/or CO?-Me?+.
Barrier properties of plasma and chemically fluorinated polypropylene and polyethyleneterephthalate
(1995)
The functionalization, perfluorination or an coating of polypropylene (PP) and polyethyleneterephthalate (PET) surfaces in different plasma atmospheres and in an F[2] + N[2] gas mixture were investigated. The aim of this work was to form a barrier layer against solvent and fuel permeation. Typical test solvents were n-pentane, toluene, tetrachloroethylene and mixtures of n-pentane and methanol. The permeation was gravimetrically measured. The permeation of the solvent mixtures was analyzed by mass spectrometry and Fourier transform IR spectroscopy. The permeation of the solvent mixtures through the plasma-modified polymer samples was associated with increased absorption of polar solvent components in the polymer film. The thickness of the plasma-fluorinated PP surface layer was 10-100 nm and that of chemically fluorinated PP about 5000 nm. Nearly the same barrier efficiency was measured for both plasma- and chemically fluorinated samples.
Several approaches were investigated to produce monosort functionalized polymer surfaces with a high density and homogeneity of functional groups: (i) Plasma oxidation followed by wet-chemical reduction, (ii) formation of radicals and grafting on of functional group carrying molecules, (iii) plasma bromination followed by (iv) Williamson or Gabriel-like synthesis of spacer molecules, and (v) a pulsed plasma polymerization of functional groups bearing monomers or (vi) their copolymerisation with other comonomers. The formation of hydroxyl (OH), primary amino (NH2), and carboxyl (COOH) groups was studied in detail. The oxygen plasma treatment (i) in a low-pressure non-isothermal glow discharge results in the formation of a wide variety of O functional groups, polymer degradation and crosslinking. Low power densities and short exposure times (0.1 to 2 s) are required to functionalize a surface while preserving the original polymer structure. Carbonate, ester, and aromatic groups are rapidly degraded by an oxygen plasma treatment leading to scissions of polymer backbones and loss in molecular weight. Also the formation of macrocycles and C=C bonds was observed in a region of around 4 nm in depth. The investigated polymers could be classified by their degradation behaviour on exposure to the oxygen plasma.___TAGSTART___BR___TAGEND___ In order to maximize the process selectivity for OH groups, the variety of oxygen functionalities formed by the oxygen plasma was wet-chemically reduced by diborane, vitridetrade (Na complex), and LiAlH4. Typical yields were 9 to 14 OH groups per 100 carbon atoms.___TAGSTART___BR___TAGEND___ Plasma bromination (iii) (40 Br per 100 C atoms) of polymers, followed by grafting of spacer molecules (iv), has been proved to be a highly selective reaction.___TAGSTART___BR___TAGEND___ Another way to produce high densities of monosort functionalities was the pulsed plasma polymerization of functional group bearing monomers such as allylamine, allylalcohol or acrylic acid (v). The retention of chemical structure and functional groups during plasma polymerization was achieved by using low power densities and the pulsed plasma technique. The maximum yields were 30 OH, 18 NH2, and 24 COOH groups per 100 C atoms. To vary the density of functional groups a chemical copolymerization with ''chain-extending'' comonomers such as butadiene and ethylene was initiated in the pulsed plasma (vi). Additionally, the often-observed post-plasma oxidations of such layers initiated by reaction of trapped radicals with oxygen from the air were successfully suppressed by using NO gas as radical quencher.
This new functionalization method consists of the deposition of very thin plasma polymer layers (20 to 100 nm) of functional group bearing monomers in pulsed plasma. With allylalcohol, a maximum of 30 OH groups per 100 C atoms was measured with a selectivity of about 90% and a significant stability at long-time exposure to air. Allylamine was used to produce primary amino groups, with a maximum of 18 NH2 groups per 100 C atoms. Side reactions were observed during the storage in air, such as oxidation of the amino groups. Carboxylic groups could be produced using acrylic acid with a maximum concentration of 24 COOH groups per 100 C atoms. The most prominent side reaction was the decarbonylation/ decarboxylation of the acid group during plasma deposition.___TAGSTART___BR___TAGEND___ The variation of the density of functional groups using the pulsed-plasma polymerization of functional-group-bearing monomers was possible by the chemically-initiated radical copolymerization with either a chain-extending monomer, such as ethylene, or a cross linker, such as butadiene, in plasma. The density of functional groups could be adjusted continuously (0 to 30 OH, 0 to 18 NH2 and 0 to 24 COOH groups per 100 C atoms).___TAGSTART___BR___TAGEND___ The successful application of these densely functionalized polymer surfaces for producing biocompatible surfaces and for use in metalpolymer composites is proposed.
The effect of the composite plasma parameter P/F, where P is the plasma power and F is the monomer flow rate, on the chemical character of pulsed plasma deposited allyl alcohol films was investigated by ToF-SSIMS. Information on the unsaturated character, the cross-linked and/or branched character of the plasma polymer films was derived in detail. The problem of the retention of OH groups in plasma deposited allyl alcohol films was elucidated in detail using SSIMS data. The lowest conversion rate from the monomer's hydroxyl groups to other oxygen functionalities in the plasma was concluded for the plasma polymer film produced at a P/F ratio of 0.05 W · sccm-1. It was found that the overall oxygen content of the films decreased vs. increasing P/F ratio. Because the freshly prepared films were investigated without air exposure, ageing on ambient air could be studied in detail. It was found that in the case of plasma deposited allyl alcohol films the ageing on air is probably based on two competing processes which are discussed in detail. Additionally, a review of literature data on the characterization of plasma deposited allyl alcohol films is given.
Plasma-deposited polymer films were prepared from organic molecules and investigated using near edge X-ray absorption fine structure (NEXAFS) and X-ray photoelectron spectroscopy (XPS) for aging effects after exposure to air. Results from the investigation of homopolymers are summarized. Primarily the effect of the deposition parameters duty cycle and power are dealt with. The effect of the deposition parameter pressure is briefly discussed. An example to show the effect of feed gas composition on the aging of plasma polymerized ethylene/allyl alcohol and styrene/allyl alcohol copolymer is also given. In general, change in content of unsaturated or aromatic species, change in concentration of monomer functionality, and change in the oxygen content was observed in the plasma polymerized films on aging.
XPS and NEXAFS spectroscopy were used for the chemical characterization of pulsed plasma-deposited ethylene films before and after exposure to ambient air. The influence of external plasma parameters on the spectroscopic results was investigated. Information on the chemical character of the plasma-polymerized films, such as the regularity of the primary structure, the amount of long-living radicals, and branching or cross-linking or both was derived from this data. Irregularity and radical concentration for post-plasma reactions of the plasma-deposited films increased with the duty cycle or power. A decreased level of monomer fragmentation and, consequently, an increase in regularity is partially concluded from the experimental data when the monomer pressure is increased. The concentration of surface radicals available for post-plasma reactions also increased with monomer pressure. The correlation found between the degree of the post-plasma oxygen incorporation and the variation of the various external parameters agreed with earlier ToF-SSIMS findings.
Static ToF-SIMS analysis of plasma chemically deposited ethylene/allyl alcohol co-polymer films
(2006)
A plasma co-polymerization of ethylene as a chain extending monomer and allyl alcohol as a carrier monomer for hydroxyl groups was studied. The composition of the feed gas was systematically varied and the plasma co-polymers were analyzed in terms of their relative concentrations of OH functional groups by static Time of Flight Secondary Ion Mass Spectrometry (ToF-SIMS) immediately after their preparation without any air contact, i.e., under so called in situ conditions.
The relative OH group concentration involved in the CH2OH groups was derived from the normalized yields of the CH3O+ secondary fragment ion. The density of functional groups in the plasma co-polymers was found to vary non-linearly with respect to the mole percentage of the monomers in the feed gas.
Co-polymerization phenomena, i.e. chemical interactions and recombination reactions taking place between monomer molecules in the plasma and/or during the deposition process, become evident in ToF-SIMS spectra.
Chemical properties of plasma-polymerized styrene films can be effectively controlled by the appropriate choice of external plasma parameters, such as duty cycle, power and monomer pressure. Chemical properties here are the regularity of the primary structure, the amount of long living radicals and branching or cross-linking or both in plasma polymerized styrene films, which can be indirectly monitored by X-ray photoelectron spectroscopy (XPS) and near edge X-ray absorption fine structure (NEXAFS) spectroscopy. Principally, XPS and NEXAFS spectra of plasma-polymerized styrene show all the spectroscopic fingerprints characteristic of atactic polystyrene indicating an inherent similarity of the respective primary chemical structures. There is an increase in irregularity and radical concentration for the plasma deposited films with increasing duty cycle or power. With an increase in monomer pressure, a decreased level of monomer fragmentation and, consequently, an increase in regularity must be concluded from the experimental data. The applied power regulates the fragmentation of the monomers as monitored by spectroscopic signals correlated to the aromatic rings. A trend in the extent of the post-plasma oxygen incorporation according to the variation of the various external plasma parameters was deduced, which agrees with earlier ToF-SIMS findings
Pulsed-plasma-deposited ethylene films were studied by time-of-flight static secondary ion mass spectrometry (ToF-SSIMS) before and after exposure to ambient air. The influence of the external plasma parameters on the secondary ion mass spectra of plasma-deposited ethylene films was investigated. From these data, information on the chemical character of the plasma-deposited ethylene films was derived. The investigation of the effect of external plasma parameters on the chemical character of the plasma-deposited ethylene films revealed that there were some drastic changes in the secondary ion mass spectra of the films. It was found that fragmentation and re-arrangement of the monomer molecules in the plasma, which affects the chemical character of the deposited films, vary according to the external plasma parameters. When the plasma polymers are exposed to air, extensive oxygen incorporation occurs. The oxygen uptake is high at the beginning and then it levels of. Some indications for the formation and decay of peroxy radicals (COO) and, subsequently, hydroperoxides (COOH) are found. It was observed that the oxygen uptake of the plasma deposited ethylene films increase when the plasma conditions become harder.
Selected FTIR, XPS and NEXAFS spectroscopy results obtained with films deposited with different plasma polymerization processes and different monomers (styrene, acetylene, ethylene and butadiene) are presented. In detail FTIR spectra, XPS surveys, XPS valence bands and core level signals including shake-up features as well as carbon K-edge absorption spectra are qualitatively and, in some cases, semi-quantitatively considered. Information on the film formation, the chemistry of the films and the film stability against air exposure are derived from spectroscopic features. With styrene chemically rather well defined plasma polymer layers can be formed with rather high deposition rates applying a pulse plasma process. Using ethylene, acetylene or butadiene as a monomer in the plasma deposition process the deposition rates are smaller. Using these monomers plasma polymer films can be obtained with a primary chemical structure which is similar to each other but more or less different from those of the respective conventional polymers. The main difference between these samples is their individual concentration of unsaturated carbon species. Finally, a technologically relevant example, i.e. a plasma deposited polymer barrier layer deposited on the inner wall of a poly(ethylene) vessel is briefly considered.
Several possibilities exist to produce a modified polymer surface with a high density of only one sort of functional group such as: (i) the plasma grafting of unfragmented monomer molecules and their polymerization forms OH, NH2, COOH groups, etc. in concentrations of approximately 25 groups per 100 C atoms; (ii) selective plasma bromination provides 1025 CBr groups; (iii) the plasma oxidation of polymer surfaces in an O2 plasma followed by the chemical reduction of all O-containing groups to OH groups by diborane, vitride (Na complex) or LiAlH4 yields 914 OH groups per 100 carbon atoms; and (iv) the grafting of spacers with different endgroups onto OH or CBr groups produces 710 spacer molecules/100 C. This work was focused on the formation of thin plasma deposited polymer layers with a maximum of (homo)functional groups and with a minimum of chemical irregularities using the pulsed plasma technique. The monomers were allylalcohol, allylamine, acrylonitrile and acrylic acid. The further intent was to study the interactions of functional groups (OH, COOH, NH2) and deposited metals (Cr, Al, Ti). It was expected that more basic (NH2), weakly basic or neutral (OH) or more acidic (COOH) groups would show different interactions and chemical reactions with metal atoms.
The retention of chemical structure and functional groups during plasma polymerization was investigated. Usually plasma polymer layers, prepared by a continuous wave radio-frequency plasma, are often chemically irregular in their structure and composition. To minimize these irregularities low wattages and the pulsed plasma technique were applied to avoid fragmentations. The first goal was to produce plasma polymers comprising double or triple bonds as precursors for electrically conducting polymers. Acetylene, ethylene, butadiene and polystyrene were used as monomers and deposited as thin polymer films by pulsed plasmas of low wattages. Styrene polymerization was strongly enhanced in the dark phase (plasma off) of a pulsed r.f. plasma caused by the reactivity of the vinyl-type double bond. This could be confirmed by a verification of a rather high chemical regularity of the film sample. The oxygen content of this film measured by X-ray photoelectron spectrometry (XPS) was in situ 0% and after 24 h exposure to air lower than 1%. Additionally, post-plasma oxidations of trapped radicals with air could be suppressed using NO gas as radical quencher. Such quenched plasma polymer layers were completely stable against oxidation for a number of weeks. During the low-wattage pulse plasma polymerization metal atoms were simultaneously or layer by layer evaporated into the growing layer and in situ measured by XPS. These metal atoms are acting as dopants. Here, Li, K, Mg and Cr were used at different concentrations providing electrical conductivity and magnetic properties for the film.
Eine neue Generation von alterungsbeständigen Plasmapolymeren mit definierter chemischer Struktur
(2000)
Polymeroberflächenfunktionalisierungen im gepulsten Plasma mit nachfolgender chemischer Behandlung
(2000)
The chemical and morphological stabilities of polymer segments in the near-surface layer were investigated by spectroscopic methods such as X-ray photoelectron spectroscopy and near-edge X-ray absorption fine structure spectroscopy. Model studies were undertaken with LangmuirBlodgett films, self-assembled monolayers and oligomer films. For thin polymer layers (30 to 500 nm), the changes in molecular-weight distributions of some polymers were investigated systematically by size exclusion chromatography, matrix-assisted laser desorption/ionizationtime-of-flight mass spectrometry and thermal-field flow fractionation for oxygen- and helium-plasma exposures. The polymer surfaces were found to be relatively stable at exposure to an oxygen low-pressure plasma up to ca. 2 s. This is important information to get maximum adhesion to metals in composites. In correlation to their redox potentials, potassium, aluminium and chromium react with oxygen functional groups at the polymer/metal interface. In a dedicated study, chromium was found to attack aromatic rings and form different reaction products.
Reactions and Intermediates at the Metal-Polymer Interface - Detected by XPS and NEXAFS Spectroscopy
(1998)
Modelling plasma-induced reactions on polymer surfaces using aliphatic self-assembling and LB layers
(1998)
Different types of plasma, irradiative and chemical activation were compared in terms of surface functionalization. Corona and spark jet plasmas are characterized by low gas temperatures and high rates in surface modification. UV irradiation in the presence of ozone does not involve any particle bombardment and acts only by enhanced photooxidative processes. Although ion implantation can be avoided, this method is not free of radiative damage in both the surface-near region and the bulk of polymers. Furthermore, its functionalization rate is low. In relation to low-pressure O2 plasma modification, all treatments mentioned here have a low efficiency in adhesion promotion due to oxidative degradation of macromolecules and formation of molecular debris known as the ''weak boundary layer''.
Up to the present, the thermomechanical loads during welding and subsequent cooling under design-specific shrinkage restraint resulting from the interaction between the materials and the structure have often not been taken into consideration approperiately for weldability assessment of components. As compared to previous investigations using small specimens this report presents component weld tests under varying intensities of restraint. Online records of the reaction forces and moments demonstrate in which way the intensity of restraint affects the reaction stresses and moments and their meaning for the evaluation of the load level in welded components.
Düring the past decades, weldability studies have predominantly been concentrated on the material and the welding process. In order to achieve a closer insight into the structural effects, component weldability tests have been performed by online monitoring of the reaction forces and moments. As a particular item, the effects of different strengths of the base and filier material on the reaction force and stress build up transverse to the welding direction have been studied at a specific structural restraint. As a most relevant result for practical welding it is demonstrated that the final reaction force and also the reaction stress level in the multilayer butt welds decreases with overmatch of the weld metal.
Pulsed plasma deposited styrene and ethylene films were studied by Time of Flight Static Secondary Ion Mass Spectrometry (ToF-SSIMS) before and after exposure to ambient air. The influence of the external plasma parameters on the secondary ion mass spectra of plasma deposited films was investigated. Approaches for the interpretation of SSIMS spectra of organic materials were reviewed and applied to the evaluation of SSIMS data of plasma deposited films. From these data, information on the chemical character of the plasma deposited films was derived.
When the plasma polymers are exposed to air oxygen incorporation occurs. The oxygen uptake is high at the beginning and then it levels of.
A relation that higher the regularity of the film lower is the oxygen uptake was found. Harder plasma conditions, which could be obtained by applying higher plasma power or lower monomer flow rate, result in higher oxygen uptake and vice versa.
Plasma polymerised films of acrylic acid, allyl alcohol and allyl amine were prepared and studied by XPS (X-ray photoelectron spectroscopy) and XAS (X-ray absorption spectroscopy). The influence of external plasma parameters on certain chemical aspects of the films was investigated. The use of XPS and NEXAFS (near edge X-ray absorption fine structure) as complimentary tools in the surface characterisation of thin films has been highlighted. Certain chemical aspects of the plasma polymerised films such as presence of ROCdouble bond; length as m-dashO in the case of plasma polymerised acrylic acid films, presence of RCdouble bond; length as m-dashO and RCOR bonds in case of plasma polymerised allyl alcohol films and presence of RCdouble bond; length as m-dashN and C?N in case of plasma polymerised allyl amine films were studied. The concentration of ROCdouble bond; length as m-dashO species was found to decrease with increase in r.f. duty cycle in the case of plasma polymerised acrylic acid films. In case of plasma polymerised allyl alcohol films there is a decrease in the concentration of RCdouble bond; length as m-dashO species and increase in the concentration of RCOR species at higher pressures, while in the case of plasma polymerised allyl amine films the concentration of RCdouble bond; length as m-dashN and C?N increases at higher powers, with an increase in C?N more pronounced at higher powers.
Br bonding on plasma brominated graphite surfaces has been studied by using Near Edge X-ray Absorption Fine Structure (NEXAFS) and X-ray Photoelectron Spectroscopy (XPS). Br2 and bromoform were used as plasma gases in an r.f. cw low pressure plasma process. Kr plasma had been used to study separately the physical and chemical plasma etching effects. At early steps of plasma bromination which lead to only small XPS Br surface concentration values a quick decay of aromaticity has been observed. At low Br surface concentration radical or even electrophilic addition of bromine onto sp2 carbon atoms is discussed as the dominating reaction pathway. At higher Br surface concentrations the inherent formation of sp3 defects in the graphene network by chemical etching processes promotes nucleophilic substitution of bromine at sp3 carbons as a competing reaction pathway. Both reaction pathways lead to CBr species characterized by the same Br 3d XPS binding energy. However more than one Br 3d component in XP spectra has been found at lower Br2 plasma induced Br surface concentrations and complexation of bromine at HOPG is assumed as a third way of interaction with Br2 plasma.
Monotype functionalizations with different types of functional groups (OH, NH2, COOH) on polypropylene and poly(tetrafluoroethylene) surfaces were synthesized using pulsed plasma-initiated homo- or copolymerization of functional group-carrying monomers. The maximum concentrations of functional groups were 31 OH, 18 NH2 or 24 COOH groups per 100 C atoms using allyl alcohol, allylamine or acrylic acid respectively as the monomer. The measured peel strengths of aluminium deposits increased linearly with the concentration of functional groups. Near the maximum concentration of OH (>27 OH/100 C atoms) or at moderate concentrations of COOH groups (>10 COOH/100 C atoms), constant (maximum) peel strengths were measured due to the mechanical collapse of one component in the composite (cohesive failure). Interface failures in Al-PP composites were found with COOH, NH2 and OH groups and cohesive failures were seen when higher concentrations of COOH groups were applied (>10 COOH/100 C atoms).
Pulsed plasma-deposited polystyrene films were studied by time-of-flight static secondary ion mass spectrometry (ToF-SSIMS) before and after exposure to ambient air. The influence of the external plasma parameters on the secondary ion mass spectra of plasma-deposited polystyrene films was investigated. From these data, information on the chemical character of the plasma polystyrene films was derived. In the range of deposition conditions applied in this study, the fragmentation of styrene is a minor process. The main process is probably the radical chain propagation to polymers. All the polystyrene plasma polymers, relying on ToF-SIMS, seem to be rather similar to a reference polystyrene oligomer sample. When the plasma polymers are exposed to air, extensive oxygen incorporation occurs. Oxygen uptake was found to alter the emission probabilities of secondary ions. A relation between the regularity of the plasma polymers and the amount of oxygen incorporation was found. The result was that the chemical regularity of the plasma polystyrene decreases when the effective power in the plasma is increased.
Plasma deposited styrene/allyl alcohol and ethylene/allyl alcohol copolymer films were prepared and characterized using XPS, NEXAFS and ToF-SIMS. The relative partial flow rates of the co-monomers are used as deposition process parameters to vary and all other process parameters were constrained to conditions optimized for retention of functional groups. By doing this it is possible to control certain chemical properties of the copolymer films such as unsaturation, oxygen and hydroxyl group relative surface contents. The aging behavior of the plasma copolymer films on air was studied, too. Non-linear variations of relative oxygen contents, contents of C—OR species and contents of carbonyl species are obtained vs. variation of feed gas composition for both monomer combinations. The chemical character of the plasma copolymer films varies between the limits given by the respective plasma homopolymers. The observed non-linear correlations are discussed in terms of approaches developed for classic radical copolymerization. The aging behavior of the different plasma copolymers films depends on the feed gas composition. Principally these aging phenomena known from plasma polymer aging studies of that respective monomer which dominates the character of the plasma copolymer are observed.
Verformungsmessungen an einem geschweißten Zahnrad infolge Spannungsarmglühen, Aufkohlen und Härten
(1982)
Plasma-chemical bromination applied to graphitic materials, in particular to highly ordered pyrolytic graphite is reviewed. The resulting bromination efficiency of the plasma-chemical treatment was subject of systematic process optimization. The plasma of elemental bromine vapour produced bromine concentrations on graphene surfaces of more than 30 % Br/C using either inductively or capacitively coupled low-pressure radio-frequency plasmas. Plasma brominated graphite surfaces have been studied by Near Edge X-ray Absorption Fine Structure, X-ray Photoelectron Spectroscopy, Atomic Force Microscopy and Scanning Electron Microscopy. The introduction of bromine into graphene-like graphite layers and its binding situation were investigated. To study the physical effect of the plasma bromination process, Kr plasma was also used because of its chemical inertness but similar atomic mass. Covering the samples with a Faraday cage or with a LiF window should help to differentiate between physical, chemical and radiation effects of the plasma. Bromination was assigned to radical or electrophilic addition of bromine onto fully substituted aromatic double bonds (sp² C) with exothermal reaction enthalpy. Low bromination shows a strong decay of aromatic double bonds, higher bromination percentage let disappear all aromatic rings. The formed C–Br bonds were well suited for efficient grafting of organic molecules by post-plasma wet-chemical nucleophilic substitution. This grafting onto the graphene surface was demonstrated using aminosilane and different diamines. The bromination of double bonds changes the hybridization of carbon atoms from plane sp² to tetrahedral sp³ hybridization. Thus, the plane topography of graphene is destroyed and the conductivity is lost.
Since more than 40 years ammonia plasma exposure of polyolefins is used for introduction of primary amino groups. The selectivity of this reaction and the yield in primary amino groups was found to be low. Here, a prominent side-reactions of this process was investigated, the hydrogenation by NH3 plasma. For identification of hydrogenation ammonia (NH3) and deuterated ammonia (ND3) were exposed to Polyethylene (h-PE) and fully deuterated polyethylene (d-PE) as well as hexatriacontane (h-HTC) and fully deuterated hexatriacontane (d-HTC) as low-molecular weight model for PE. HD exchange was assumed and detected by Time-of-Flight Secondary Ion Mass Spectrometry (ToFSIMS), X-ray Photoelectron Spectroscopy (XPS), Attenuated Total Reflectance (ATR-FTIR) and 1H and 2H Nuclear magnetic Resonance. Results show a significant HD exchange within the sampling depth of ATR (2.5 µm). However, N- and NH2 introduction was limited to the topmost surface as shown by SIMS and XPS (a few nanometers).
ToF-SIMS has been used to study the surface functionalization of polypropylene and polyethylene samples by exposure to low-pressure ammonia plasma. Static secondary ion mass spectrometry is an appropriate tool to determine hydrogen isotopes as elements and in fragment ions with high sensitivity and selectivity. Specifically the exchange of hydrogen isotopes and the incorporation of N-containing moieties in the near-surface layer of the polyolefins have been studied in ND3 plasma experiments with conventional polypropylene (h-PP) and polyethylene (h-PE) and NH3 plasma experiments with deuterated polyethylene (d-PE). Considering the exchange of hydrogen between the plasma and the polymer surface studied by using deuterated ammonia and polyolefin samples the conclusion has been derived that polypropylene with its side chain methyl groups is more susceptible to hydrogen exchange reactions. For ND3 plasma treatment of polyethylene and polypropylene similar N-containing fragments were obtained and the measured semi-quantitative ToF-SIMS N-uptake data are rather similar. The observation of a wide range of characteristic mixed CkNlHmDn+ secondary fragment ions suggests complex and manifold reaction pathways at the polymer–plasma interface besides simple grafting of –ND2 or –NH2 moieties formed by ammonia fragmentation in the plasma. Finally, indications of an isotopic effect for hydrogen isotopes in the plasma process have been observed by comparison of ND3/h-PE results with those of NH3/d-PE.
Die hier vorgestellte Großanlage zur Prüfung und Simulation von Bauteil schweißungen (GAPSI 16) mit einer Maximalprüfkraft von ±16 MN erlaubt wirklichkeitsnahe Analysen des Bau teilverhaltens während des Schwei ßens. Ein fundamentaler Vorteil ge genüber konventionellen Universal prüfmaschinen ist, Momente während des Schweißens mittels acht unabhän giger Hydraulikzylinder in zwei Prüf tischen aufbringen bzw. registrieren zu können.
Derzeitige Forschungsvorhaben sind zum einen Spannungs- und Verformungsvorgängen während des Schweißens von Blechen und zum anderen Modellen gewidmet, womit Kenngrößen für Flammrichtarbeiten ermittelt werden können. Simulations versuche an Großproben tragen we sentlich zu höherer Aussagesicherheit bei, zumal konventionelle Prüfmetho den mit einfachen Kleinproben und auch Berechnungen nach der Finite Elemente-Methode (FEM) stets Rand bedingungen und zumeist größere Idealisierungen enthalten. Dagegen weist die Großprüfanlage GAPSI 16 mit angepaßten Probengeometrien und Spannkräften einen neuen Weg.