Monitoring of PAH in aqueous samples - a comparison of different sample preparation techniques
(2011)
Synthetic athletic tracks and turf areas for outdoor sporting grounds may release contaminants due to the chemical composition of some components. A primary example is that of zinc from reused scrap tires (main constituent, styrene butadiene rubber, SBR), which might be harmful to the environment. Thus, methods for the risk assessment of those materials are required. Laboratory leaching methods like batch and column tests are widely used to examine the soil–groundwater pathway. We tested several components for artificial sporting grounds with batch tests at a liquid to solid (LS) ratio of 2 L/kg and column tests with an LS up to 26.5 L/kg. We found a higher zinc release in the batch test eluates for all granules, ranging from 15% higher to 687% higher versus data from column tests for SBR granules. Accompanying parameters, especially the very high turbidity of one ethylene propylene diene monomer rubber (EPDM) or thermoplastic elastomer (TPE) eluates, reflect the stronger mechanical stress of batch testing. This indicates that batch test procedures might not be suitable for the risk assessment of synthetic sporting ground components. Column tests, on the other hand, represent field conditions more closely and allow for determination of time-dependent contaminants release.
Laboratory leaching tests may be used for source term determination as a basis for risk assessment for soilgroundwater pathway (leachate forecast) on contaminated sites in Germany. Interlaboratory comparisons on the evaluation of the reproducibility of column percolation tests were conducted within the framework of an integrated R + D program using three waste reference materials.
The interlaboratory comparisons of column percolation tests showed good reproducibility of the results for inorganic and organic parameters as well as for the accompanying parameters. This is due to the stipulations concerning the time of contact between leachant and sample material as well as the sample placement in the columns. Different column dimensions used by the participants of the interlaboratory comparisons did not have any substantial influence on the column test results.