Filtern
Dokumenttyp
- Zeitschriftenartikel (21)
- Beitrag zu einem Sammelband (10)
- Sonstiges (8)
- Vortrag (7)
- Beitrag zu einem Tagungsband (6)
- Posterpräsentation (1)
Schlagworte
- RFA (5)
- Röntgenfluoreszenzanalyse (5)
- XRF (5)
- Albrecht Dürer (4)
- Silberstiftzeichnung (4)
- Silverpoint drawing (4)
- X-ray spectrometry (4)
- Synchrotron (3)
- Archaeometry (2)
- Archäometrie (2)
Eingeladener Vortrag
- nein (7)
Quantification of energy dispersive SRXRF for the certification of reference materials at BAMline
(2010)
The certification of reference materials (CRMs) is one of the main tasks of the BAM Federal Institute for Materials Research and Testing. In this context CRMs for analytical chemistry play the dominant role. Traditionally, energy dispersive X-ray fluorescence (EDXRF) has been excluded from the final certification scheme. It has lacked the proof to be reliable enough due to peak overlapping and risks of incorrect background subtraction leading to unacceptable uncertainty and bias of the results. The development described aims at enabling ED-SRXRF to really contribute to certification by the aid of synchrotron radiation. This has been partly shown for macrocontents and has been successfully demonstrated for trace elements and thin layers. The method is based on a combination of measurements of pure elements or stoichiometric compounds as comparator materials and Monte Carlo simulations. Measurements have been performed at the BAMline, the hard X-ray beam line of the BAM at the synchrotron BESSY II in Berlin.
The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAMline) can now be used for absorption, refraction as well as phase contrast dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope up to 14 mm x 14 mm field of view) to high resolution (microscope down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science.
C, N, O, F and P can be analyzed by instrumental photon activation analysis (IPAA) including decay curve analysis. The interference of 30P (T1/2 = 149.9 s) by 15O (T1/2 = 122.2 s) can be ruled out by direct positron measurement making use of the largely different maximum β+-energies of both nuclides (3.24 MeV and 1.73 MeV, respectively). Interference by carbon (11C) can be avoided by sub-threshold activation with 17 MeV bremsstrahlung. The short half-life of 30P allows a high productivity of the method. Reliability was demonstrated in the range of 0.2%2% P (detection limit = 40 µg/g). Analysis of a certified reference material (BCR-CRM 063) yielded excellent agreement with the certified data.
New analyses of a series of very rare silverpoint drawings that were executed by Rembrandt Harmensz. van Rijn (16061669) which are kept today in the Kupferstichkabinett (Museum of Prints and Drawings) of the State Museums of Berlin are reported here. Analysis of these drawings requires particular attention because the study has to be fully non-destructive and extremely sensitive. The metal alloy on the paper does not exceed some hundreds of µg/cm². Therefore, synchrotron radiation induced X-ray fluorescence (SR-XRF) is together with external micro-proton-induced X-ray emission the only well-suited method for the analyses of metalpoint drawings. In some primary work, about 25 German and Flemish metalpoint drawings were investigated using spatially resolved SR-XRF analysis at the BAMline at BESSY. This study enlarges the existing FrenchGerman database of metalpoint drawings dating from the 15th and 16th centuries, as these Rembrandt drawings originate from the 17th century where this graphical technique was even rarer and already obsolete. It also illustrates how SR-XRF analysis can reinforce art historical assumptions on the dating of drawings and their connection.
The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications.