Zusammenfassung
The working principle of nuclear analytical methods (NAMs) is not influenced by the chemical bond. Consequently, they are independent counterparts to the well-known chemical procedures. NAMs obey fundamental laws or can be described and understood thoroughly. This qualifies them as candidates for reference methods. Although following similar nuclear reaction schemes, they comprise bulk analyzing capability (neutron and photon activation analysis) as well as detection power in surface near regions of solids (ion beam techniques). Prominent features of NAMs are sensitivity, selectivity, multielement determination and linearity of the calibration function covering a concentration range of several orders of magnitude. Moreover, ion beam techniques allow depth profiling with nm-resolution in several cases while the ion microprobe additionally offers a lateral resolution in the wm-scale. As NAMs require expensive apparatus (nuclear reactor, accelerator in radioactive control areas) their availability is restricted to a small number of suitably equipped institutes. However, they are able to solve complex analytical tasks, take part in key comparisons and play an essential role in the certification of reference materials.
Strahlenverfahren in Kombination - ein Werkzeug für Analyse und Zertifizierung von Feststoffen
(2002)
Orientierende Versuche zur Schwefelbestimmung in Kraftstoffen haben gezeigt, dass die Röntgenbeamline der BAM bei BESSY II geeignet ist, Schwefel auch in kleinen Konzentrationen zu bestimmen. Da das Verfahren der synchrotronstrahlungsinduzierten Röntgenfluoreszenzanalyse (SYRFA) für den Vor-Ort-Einsatz nicht geeignet ist, ist das Ziel der Untersuchungen, durch Variation von Anregungsenergie und -geometrie mögliche Quellen für systematische Fehler zu untersuchen. Durch geeignete Korrekturfaktoren kann dann die Richtigkeit der Analyseergebnisse gewährleistet werden. Das Verfahren soll dann als Alternative bzw. Ergänzung zu zerstörenden Verfahren der Schwefelanalyse Anwendung finden. Damit wird ein Beitrag zur künftigen Herstellung zertifizierter Referenzmaterialien (ZRM) geleistet.
The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications.
The neutron transmutation doping (NTD) of highly pure copper with zinc was investigated as a promising means of achieving controlled gradation of the zinc content in the range 1-20 wg g-1. The doping process leads to the enrichment of two stable isotopes 64Zn and 66Zn in a ratio which differs from that of natural isotopic distribution. Mass spectrometric investigations by thermal ionization mass spectrometry (TIMS) were performed to validate the results obtained by gamma spectrometry. The investigations included both determination of the isotopic ratios of the doped zinc isotopes and the analysis of the accumulated zinc contents by isotope dilution (ID) analysis. Thereby a sample-specific correction of the blank could be performed because the isotope 68Zn was not influenced, because of the transmutation process. The results obtained by TIMS prove the strict proportionality of the doped zinc content, in the range 5 to 20 wg g-1, to the neutron fluence. Comparison with gamma spectrometric results showed a very good agreement within the uncertainties.
The first hard x-ray beamline at BESSY II has been installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a double-multilayer monochromator and a double-crystal monochromator. Depending on the application, the two devices are used separately or in-line. The main applications of the monochromatic radiation with photon energies up to 60 keV are x-ray fluorescence analysis, micro computed tomography, x-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV is available for radiometric applications.
A new application of neutron transmutation doping is described. The method is useful to prepare graded zinc contents in highly pure copper materials. The research reactor BER II at the Hahn-Meitner-Institute, Berlin served as a neutron source. The zinc content produced in the samples was analyzed by determining the 65Zn-activity via gamma-spectrometry. Simultaneously irradiated flux monitors were used to determine the neutron flux density. Since cylindrical sample geometries are favorable for a reference material application in optical emission (OE) spectroscopy, the spatial distribution of the induced activity in a cylinder with a diameter of 8 mm and a length of 35 mm was investigated.
New analyses of a series of very rare silverpoint drawings that were executed by Rembrandt Harmensz. van Rijn (16061669) which are kept today in the Kupferstichkabinett (Museum of Prints and Drawings) of the State Museums of Berlin are reported here. Analysis of these drawings requires particular attention because the study has to be fully non-destructive and extremely sensitive. The metal alloy on the paper does not exceed some hundreds of µg/cm². Therefore, synchrotron radiation induced X-ray fluorescence (SR-XRF) is together with external micro-proton-induced X-ray emission the only well-suited method for the analyses of metalpoint drawings. In some primary work, about 25 German and Flemish metalpoint drawings were investigated using spatially resolved SR-XRF analysis at the BAMline at BESSY. This study enlarges the existing FrenchGerman database of metalpoint drawings dating from the 15th and 16th centuries, as these Rembrandt drawings originate from the 17th century where this graphical technique was even rarer and already obsolete. It also illustrates how SR-XRF analysis can reinforce art historical assumptions on the dating of drawings and their connection.
The ?- branching ratio of 64Cu was determined by investigating the resulting decay products in copper doped by neutron transmutation. The numbers of 64Zn and 64Ni atoms were analyzed using isotope dilution analysis combined with thermal ionization mass spectrometry. A ?- branching ratio of (38.06±0.30)% was obtained, which agrees with the study of Kawada (Appl. Radiat. Isot. 37 (1) (1986) 7) to a higher accuracy. However, our result differs from the value cited in the NUDAT database of (39.0±0.3)%.
Large-volume instrumental photon and neutron activation analysis (IPAA resp. INAA) was used for
investigation of shredded electronic waste material. Sample masses from 1 to 150 grams were analysed
to obtain an estimate of the minimum sample size to be taken to achieve a representativeness
of the results which is satisfactory for a defined investigation task. Furthermore, the influence of
irradiation and measurement parameters upon the quality of the analytical results were studied. Finally,
the analytical data obtained from IPAA and instrumental neutron activation analysis (INAA),
both carried out in a large-volume mode, were compared. Values within the limits of satisfactory
agreement were found only partially. Analytical process control using on-site X-ray fluorescence
analysis performed during recycling of electronic waste is currently under development.
The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAMline) can now be used for absorption, refraction as well as phase contrast dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope up to 14 mm x 14 mm field of view) to high resolution (microscope down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science.
In activation analysis of traces in small samples, the non-equivalence of the activating radiation doses of sample and calibration material gives rise to sometimes tolerable systematic errors. Conversely, analysis of major components usually demands high trueness and precision. To meet this, beam geometry activation analysis (BEAMGAA) procedures have been developed for instrumental photon (IPAA) and neutron activation analysis (INAA) in which the activating neutron/photon beam exhibits broad, flat-topped characteristics. This results in a very low lateral activating flux gradient compared to known radiation facilities, however, at significantly lower flux density. The axial flux gradient can be accounted for by a monitor-sample-monitor assembly. As a first approach, major components were determined in high purity substances as well as selenium in a cattle fodder additive.
Spatially resolved X-ray fluorescence analysis using synchrotron radiation (SR-XRF) at the wavelength shifter beamline, BAMline, at BESSY was used to investigate Renaissance silverpoint drawings as it is extremely sensitive, non-destructive and can be carried out in air using an excitation spot in the hundred micrometer range.
This paper deals with first results of the study of silverpoint drawings of Albrecht Dürer (14711528) belonging to the sketchbook that Albrecht Dürer used during a travel to the Netherlands in 1520/21. These results are compared to a PIXE study performed on drawings from the same sketchbook.
The minor element composition of the silverpoint used for the drawings in the sketchbook was (10.6 ± 3.5) wt.% of Cu and traces of Zn. Mercury was found in the marks but does not belong to the initial composition of the silverpoint as it is attributed to an alteration phenomenon. One drawing of the sketchbook represents an exception. It consists of silver marks containing an additional minor element, Zn, in the marks and was, therefore, created with another silverpoint, probably at a different time than the other drawings.
Synchrotron-induced X-ray fluorescence (Sy-XRF) analysis was used to study the chemical composition of precious Renaissance silverpoint drawings. Drawings by famous artists such as Albrecht Dürer (14711528) and Jan van Eyck (approximately 13951441) must be investigated non-destructively. Moreover, extremely sensitive synchrotron- or accelerator-based techniques are needed since only small quantities of silver are deposited on the paper. New criteria for attributing these works to a particular artist could be established based on the analysis of the chemical composition of the metal points used. We illustrate how analysis can give new art historical information by means of two case studies. Two particular drawings, one of Albrecht Dürer, showing a profile portrait of his closest friend, Willibald Pirckheimer (1503), and a second one attributed to Jan van Eyck, showing a Portrait of an elderly man, often named Niccolò Albergati, are the object of intense art historical controversy. Both drawings show inscriptions next to the figures. Analyses by Sy-XRF could reveal the same kind of silverpoint for the Pirckheimer portrait and its mysterious Greek inscription, contrary to the drawing by Van Eyck where at least three different metal points were applied. Two different types of silver marks were found in this portrait. Silver containing gold marks were detected in the inscriptions and over-subscriptions. This is the first evidence of the use of gold points for metal point drawings in the Middle Ages.
Quantification of energy dispersive SRXRF for the certification of reference materials at BAMline
(2010)
The certification of reference materials (CRMs) is one of the main tasks of the BAM Federal Institute for Materials Research and Testing. In this context CRMs for analytical chemistry play the dominant role. Traditionally, energy dispersive X-ray fluorescence (EDXRF) has been excluded from the final certification scheme. It has lacked the proof to be reliable enough due to peak overlapping and risks of incorrect background subtraction leading to unacceptable uncertainty and bias of the results. The development described aims at enabling ED-SRXRF to really contribute to certification by the aid of synchrotron radiation. This has been partly shown for macrocontents and has been successfully demonstrated for trace elements and thin layers. The method is based on a combination of measurements of pure elements or stoichiometric compounds as comparator materials and Monte Carlo simulations. Measurements have been performed at the BAMline, the hard X-ray beam line of the BAM at the synchrotron BESSY II in Berlin.
C, N, O, F and P can be analyzed by instrumental photon activation analysis (IPAA) including decay curve analysis. The interference of 30P (T1/2 = 149.9 s) by 15O (T1/2 = 122.2 s) can be ruled out by direct positron measurement making use of the largely different maximum β+-energies of both nuclides (3.24 MeV and 1.73 MeV, respectively). Interference by carbon (11C) can be avoided by sub-threshold activation with 17 MeV bremsstrahlung. The short half-life of 30P allows a high productivity of the method. Reliability was demonstrated in the range of 0.2%2% P (detection limit = 40 µg/g). Analysis of a certified reference material (BCR-CRM 063) yielded excellent agreement with the certified data.