Ermittlung des Chloridgehaltes von Betonproben mit Laser-Induzierter Breakdown Spektroskopie (LIBS)
(2004)
Quantitative determination of sulfur content in concrete with laser-induced breakdown spectroscopy
(2005)
Laser-induced breakdown spectroscopy has been employed for the investigation of the sulfur content of concrete. Sulfur compounds are a natural but minor component in building materials. The ingress of sulfates or sulfuric acid constitutes a major risk of chemical aggression for concrete. There is a need for a fast method, which can be used on-site and is able to investigate a wide range of different measuring points, so that damages can be characterized.
For quantitative determination the sulfur spectral line at 921.3 nm is used. The optimum ambient atmosphere has been determined by comparison of measurements accomplished under air, argon and helium atmosphere.
Reference samples have been produced and calibration curves have been determined, the results of LIBS measurements are compared with results from chemical analysis. Defining a limit for the intensity ratio of a calcium and a oxygen spectral line can reduce the influence of the heterogeneity of the material, so that only spectra with a high amount of cementitious material are evaluated. Depth profiles and spatial resolved sulfur distributions are presented measured on concrete cores originating from a highly sulfate contaminated clarifier.
Sulfate attack constitutes a major risk of chemical aggression for concrete and other building materials. Mainly structures exposed to sewage waters and sulfate rich soils are affected. The measurement of sulfate ingress is important for damage assessment previous to repair works and for quality assurance of the effectiveness of protecting coatings or during concrete removal.
Laser induced breakdown spectroscopy is introduced for the quantitative measurement of sulfur contents in building materials, providing detailed depth profiles and imaging element distributions with 1 mm spatial resolution. Detailed statistical evaluation is possible due to the spatial resolution and the fast measurement of the method. Practical applications of the method for damage assessment are demonstrated for three different sewage plants.
Laser-induced breakdown spectroscopy has been used for quantitative measurement of trace elements, e.g. sulfur and chlorine, in concrete. Chloride and sulfate ions have a large effect on the durability of concrete structures, and quantitative measurement is important for condition assessment and quality assurance. Concrete is a highly heterogeneous material in composition and grain-size distribution, i.e. the spatial distribution of elements. Calibration plots were determined by use of laboratory-made reference samples consisting of pressings of cement powder, hydrated cement, cement mortar, and concrete, in which the heterogeneity of the material is increasing because of the aggregates. Coarse aggregate and cement paste are distinguishable by the intensity of the Ca spectral lines. More advanced evaluation is necessary to account for the effect of the fine aggregate. The three series of reference samples enable systematic study of the effects of heterogeneity on spectral intensity, signal fluctuation, uncertainty, and limits of detection. Spatially resolved measurements and many spectra enable statistical evaluation of the data. The heterogeneity has an effect on measurement of the sulfur and chlorine content, because both occur mainly in the cement matrix. Critical chloride concentrations are approximately 0.04% (m/m). The chlorine spectral line at 837.6 nm is evaluated. The natural sulfur content of concrete is approximately 0.1% (m/m). The spectral line at 921.3 nm is evaluated. One future application may be simultaneous determination of the amount of damaging trace elements and the cement content of the concrete.
Zuverlässige Bestimmung von Chloridgehalten bei der Instandsetzung tausalzgeschädigter Bauwerke
(2010)
Nuclear Power Plants have been in operation for ca. 50 years. Based on this experience, non-destructive testing tasks specific to thick and highly reinforced nuclear containment structures have materialized. The performance based Service life extension of existing NPPs also needs a measurement based decision to support continuing the service of the concrete part of the installations.
By nature, concrete is a very durable material and any natural Deterioration processes may take a long time to become critical to the structure. The experience of more than 50 years of service limits the testing tasks to a few ones which are not yet solved.
Research in NDT of concrete structures is performed by many research institutions all over the world with different technical and systematic approaches. Results are mainly obtained on laboratory specimens, sometimes additional field studies are reported. This research takes place independently without coordination and as a result, the outcomes mostly lack full comparability.
Software for data analysis has become indispensable and very powerful. This part of testing needs more attention when it comes to evaluate test results. Validation of NDE solutions is becoming a critical part in concrete structure testing.
Validation is by definition the proof that a customer´s requirements in the test are being met by the testing solution. This includes equipment, personnel qualification and data analysis. In the following tables, the research recommendation Validation is used in the sense, that proof of the performance of existing solutions needs to be adressed. In general, a validation methodology for NDE solutions for concrete testing in itself needs to be researched and established.
Comparability of research also needs an accepted and easily accessible reference. From experience, it is almost impossible to manufacture exact copies of test specimens at different locations. Round Robin tests are therefore needed to evaluate the performance of a test.
Data evaluation is generally done using dedicated software, sometimes Hardware dependant and not interchangeable between systems. Software is ever more increasingly becoming more powerful and sophisticated. An in-depth evaluation needs to address the comparability and validation of Software used for data analysis and evaluation. The vision of a unified software pool for NDE investigations would undoubtedly support research tremendously.
Quantitative NDE is mostly recommended to assess the condition of a structure. However, qualitative data can be very useful, especially for processes which change the material properties or deteriorate the structure (e.g. corrosion of reinforcement). The need for reliable baseline data is a key factor for such monitoring tasks.