Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (15)
- Beitrag zu einem Sammelband (10)
- Zeitschriftenartikel (1)
- Corrigendum (1)
- Forschungsbericht (1)
Sprache
- Englisch (28) (entfernen)
Referierte Publikation
- nein (28) (entfernen)
Schlagworte
- Composite liner (3)
- Contaminant transport (2)
- Durability (2)
- Geomembranes (2)
- Geosynthetics (2)
- Geotextiles (2)
- Landfill (2)
- Organic contaminants (2)
- Aging (1)
- Antioxidant (1)
Organisationseinheit der BAM
Testing of the oxidative resistance of polyolefin based geosynthetics in
autoclaves at high oxygen pressure has been suggested as an alternative method to
conventional forced-air oven aging. The intention is to shorten considerably the testing
time and to ensure that aging is performed under the condition of rate-controlled
and not diffusion-limited oxidation. We compare data from high pressure autoclave
tests (HPAT) with data from oven aging and water immersion tests at 80 °C. For this,
the stabilization of the samples has to be taken into account. Polyolefin based geosynthetics
are usually stabilized by two types of “packages” of antioxidants (AO), designated
here as P1 and P2. P1 consists of phenols and phosphites, P2 of hindered amine
stabilizers (HAS) in addition to a marginal stabilization P1 of the resin for the manufacturing
process. Phenolic and phosphite AO are quickly consumed in the HPAT.
Failure time is tremendously reduced compared to forced-air oven aging or water
immersion. The results are discussed within the framework of a basic autoxidation
scheme (Wise et al., 1997). The reduction is much greater than expected from theoretical
considerations. Therefore, a direct and degrading reaction of oxygen with the AO
has to be assumed. In case of HAS, the time dependence of the degradation of tensile
properties in the HPAT is significantly different from the dependence observed in
conventional forced-air oven aging and their effectiveness is likewise strongly reduced.
A conclusive interpretation of HPAT results needs a better understanding of
what happens to the AO at high oxygen pressure.
This is a corrigendum to the original article "Determining the thickness and completeness of the shell of polymer core-shell nanoparticles by X-ray photoelectron spectroscopy, secondary ion mass spectrometry, and transmission scanning electron microscopy" that was published in "The journal of physical chemistry C", vol. 123 (2019), no. 49 pp. 29765-29775.
Long term behaviour of composite liners under exposure to a mixture of concentrated hydrocarbons
(1999)
To properly understand and assess the long-term behaviour of geosynthetic materials it is necessary to investigate the various types of possible degradation mechanims. This includes both chemical and mechanical behaviour, and sometimes even their interactions with one another. Clearly, chemical degradation of geosynthetics depends on the polymer type. For example, polyolefins are vulnerable to oxidation; polyesters are susceptible to hydrolysis; and plasticizers can leach from polyvinyl chloride. This paper describes the concept of these three types of degradation, but focuses on the oxidation of polyolefins since the majority of the geosynthetics is made from this type of polymer. The methods used to predict the lifetime of antioxidants and service life of the geosynthetic material will be illustrated. Furthermore, the influence of temperature, pressure, and ultraviolet light on the service life are also demonstrated. Finally, the current specifications targeting the longevity of different geosynthetics are presented.
Regarding mechanical degradation, the paper mainly focuses upon the creep deformation of geogrids and stress crack resistance (SCR) of polyethylene geomembranes and geopipe. The method to assess stress crack resistance is described, and the microscopic mechanisms that lead to such failure are explained. For creep evaluation, different acceleration tests are presented and their applicability with respect to the different types of polymers is illustrated. In addition, the long-term shear behaviour of geocomposites and geosynthetic clay liners is presented.
The German landfill ordinance regulates the use of geosynthetics, polymers and leak detection systems (LDS) in the field of landfill engineering in Germany. It governs the certification process and sets a framework for the requirements on these products. The certification guidelines of the BAM Federal Institute of Materials Research and Testing turn these requirements into detailed technical specifications and associated test procedures. The present paper describes the procedure of developing certification guidelines for LDS by BAM and its advisory board. The requirements for the certification of LDS under the terms of the new German landfill ordinance with regard to operation and capability are listed and the technical criteria are described. The performance test for LDS used in connection with geomembranes is discussed in detail.
An approach to achieve “zero leakage” is discussed with respect to the experience in Germany, where strict regulations for landfill lining and capping systems have been developed and issued because of large environmental problems related to landfills that accumulated in the 1970’s and 1980’s. Using a thick, high quality HDPE geomembrane (GMB), which is installed free of residual waves and wrinkles in intimate contact with a compacted clay liner (CCL) or geosynthetic clay liner (GCL) of very low permeability, by a qualified, experienced, well equipped and properly third-party controlled installer and which are protected by heavy protection layers designed with respect to long-term performance of the GMB, may result in a liner or capping system of practically no leakage. This is demonstrated by analyzing results of measurements obtained from permanently installed leak detection systems in combination with HDPE GMBs. The survey is based on 32 German landfills with 1,276,500 m² of installed HDPE GMB.
The behaviour of HDPE geomembranes and installation quality control in geotechnical application
(2013)
The German Landfill Ordinance regulates the use of geosynthetics and other materials in the field of waste Containment Systems. It requires a certification of the geosynthetics by the BAM. The certification-guidelines define the state of the art by giving detailed requirements and specifications i the various geosynthetic products used in landfill constructions. According to the German Landfill Ordinance geosynthetic products have to fulfil their function for more than 100 years. Beyond, supported by an advisory board of landfill experts, BAM has developed installation requirements and demands on quality management for production, installation and third party control. The BAM is responsible to define tests and testing criteria for geosynthetics, to include provisions into the certification document and in addition to stipulate requirements with regard to installation procedure and quality management in Germany. All documents of the BAM such as certification guidelines, recommendations and testing specifications which are approved by the advisory board are published in German language on the website and in the Official Gazette*** of the BAM. For the certification one of the basic requirements is that the geosynthetic product is produced with well defined and well reproducible properties. Thus, a sophisticated quality management System is needed. In addition, not only production control, but also a quality assurance for the installation is necessary.
Designing the performance of geogrids in reinforce soil constructions usually does not consider long-term behavior and possible failure modes of junctions between longitudinal and transverse ribs. How could behavior of junctions be included? To which extend is it necessary? On the conference Geo-Chicago 2016, Swan and Yuan presented an ultimate limit state equation for the short-term material resistance of junctions. We discuss limitations and suggest improvements to include long-term behavior of junctions. Nevertheless, the approach applies only to a specific mode of shear-tensile failure of junctions and only to strictly rigid geogrids. A new design concept presented in the same year by Jacobs on the conference GeoAmerica for the special case of the anchorage of geogrids, which reinforce capping system on long and steep slopes of landfills, tried to overcome these drawbacks. We discuss the aspects of this concept related to the long-term behavior
of junctions and the interplay between the load applied to junctions and the flexibility of longitudinal ribs. This interplay and the long-term junction strength determine the long-term behavior of geogrids.