Filtern
Erscheinungsjahr
- 2014 (3) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (3) (entfernen)
Schlagworte
- Aging (1)
- BAM-Zulassung (1)
- Bispidines (1)
- CE-Kennzeichnung (1)
- Chelates (1)
- Chemical reduction factor (1)
- Deponieverordnung (1)
- Geogrid (1)
- Geokunststoffe (1)
- Hydrolytic degradation (1)
Data from four samples of commercially available PET geogrids (made either of yarns or bars), which were measured by BAM or other institute, are analyzed to discuss the procedure and problems of determining the chemical reduction factor RFCH associated with a certain service life. Estimates from Arrhenius extrapolation usually have very large statistical errors. The level of confidence must therefore be specified. A reliable estimate requires data from immersion tests below the glass transition temperature of PET. To extrapolate the time of reductions for each reduction factor at such low temperatures, one has to know the functional form of the mechanical degradation curve. It is shown how the degradation curve of the tensile strength may be obtained by determining the relation between increase in concentration of carboxyl end group (CEG) and decrease in tensile strength. Therefore, experimental studies to determine the chemical reduction factor should be accompanied by the measurements of the CEG concentration and the intrinsic viscosity. Furthermore, such measurements allow a non-ambiguous determination of the molecular mass. Hydrolytic molecular degradation will proceed continuously even at 20 °C with half-life of the inverse of the CEG concentration of 40–100 y. Nevertheless, small chemical reduction factors at a lifetime of 100 y are obtained with high level of confidence for materials with low initial CEG concentration and high molecular mass. This is shown by pooling data from samples with comparable CEG concentration, molecular mass and above all comparable intrinsic relation between increase in CEG concentration and decrease in strength. Therefore, the recommendation of ISO TR 20432, Table 2, for chemical reduction factors seems to be applicable to PET geogrids with index properties well below the one specified by the technical report. Whether these index properties are actually a sufficient condition to have small chemical reduction factors even at a very long service life is still an open question. The determination of chemical reduction factor should be based on aging experiments, at least for products with index properties close to the limiting values for the following reasons. (1) Even so standards are available, results of different laboratories on absolute values of CEG concentration and number averaged molecular mass differ to a certain extent. (2) Other factors, like crystallization, affect the mechanical degradation significantly. (3) There is no universally applicable form of the mechanical degradation curve.
Bispidines for dual imaging
(2014)
The efficient transformation of the hexadentate bispidinol 1 into carbamate derivatives yields functional bispidines enabling convenient functionalization for targeted imaging. The BODIPY-substituted bispidine 3 combines a coordination site for metal ions, such as radioactive 64CuII, with a fluorescent unit. Product 3 was thoroughly characterized by standard analytical methods, single crystal X-ray diffraction, radiolabeling, and photophysical analysis. The luminescence of ligand 3 was found to be strongly dependent on metal ion coordination: CuII quenches the BODIPY fluorescence, whereas NiII and ZnII ions do not affect it. It follows that, in imaging applications with the positron emitter 64CuII, residues of its origin from enriched 64Ni and the decay products 64NiII and 64ZnII, efficiently restore the fluorescence of the ligand. This allows for monitoring of the emitted radiation as well as the fluorescence signal. The stability of the 64CuII–3 complex is investigated by transmetalation experiments with ZnII and NiII, using fluorescence and radioactivity detection, and the results confirm the high stability of 64CuII–3. In addition, metal complexes of ligand 3 with the lanthanide ions TbIII, EuIII, and NdIII are shown to exhibit emission of the BODIPY ligand and the lanthanide ion, thus enabling dual emission detection.
In absehbarer Zeit werden CE-gekennzeichnete Geovliesstoffe, Geogewebe, geosynthetische Dränelemente und Geogitter aus Kunststoff erhältlich sein, bei denen die CE-Leistungserklärung den Hinweis enthält 'dauerhaft für bis zu 100 Jahre' oder sogar 'dauerhaft für mindestens 100 Jahre'. Hersteller, Bauherren, Planer und zuständige Behörden werden sich daher die Frage stellen, ob diese Produkte auf der Grundlage von Anhang 1 Nummer 2.1 Satz 7 Ziffer 1 der Deponieverordnung (DepV) im Deponiebau auch ohne Zulassung verwendet werden dürfen. Ein Vergleich der europäisch harmonisierten Bauproduktnormen DIN EN 13252 und DIN EN 13257, die der CE-Kennzeichnung der Geotextilien und geotextilverwandten Produkte zugrunde liegen, mit den Anforderungen der DepV zeigt nun aber, dass nur ein Teil der für den Deponiebau wesentlichen technischen Eigenschaften in diesen Normen erfasst werden. Daher sind für CE gekennzeichnete Produkte zusätzliche Prüfungen auf der Grundlage der DepV-Liste der Kriterien und Einwirkmechanismen erforderlich. Die in den Produktnormen beschriebene Qualitätssicherung ist nach Anhang 1 Nummer 2 Satz 14 ff der DepV ebenfalls für die Gleichwertigkeit nicht ausreichend. Eine CE-Kennzeichnung ist deshalb noch kein Nachweis, dass die Produkte dem Stand der Technik nach der DepV entsprechen und die Eigenschaften der Produkte den geforderten Eigenschaften im Wesentlichen gleichwertig sind, auch wenn mit Bezug auf den Anhang B der genannten Normen deren Dauerhaftigkeit für 100 Jahre vom Hersteller deklariert wird.----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
In the near future, CE-marked woven and nonwoven geotextiles, geocomposite drains and geogrids will be available on the market, whose declaration of performance will contain the qualification 'predicted service life up to 100 years' or even 'predicted service life minimum 100 years'. Manufacturer, principals and their design engineers as well as the responsible authorities will have to deal with the question, whether such products can be used on the basis of Annex 1, no. 2.1, sentence 7, cipher 1 of the German landfill ordinance (DepV) as components of landfill liner and capping systems. A comparison of the harmonized European standards hEN 13252 and 13257, on which the CE-marking of geotextiles and geotextile-related products is based, with the DepV, shows that only a few of the essential technical characteristics actually relevant for landfill constructions are considered in these standards. Therefore, additional tests based on the DepV-list of criteria and mechanisms of action are necessary for CE-marked products. Requirements on quality managements in the hEN are likewise not adequate for essential equivalence with respect to annex 1, No. 2.1, sentence 14 ff, DepV. Therefore, CE-marking is actually no proof of the fulfilment of the state of the techno logy according to the DepV and of the essential equivalence of product properties to the required properties, albeit the declaration of performance indicates a predicted service life of 100 years.