Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (81)
- Preprint (8)
- Sonstiges (7)
- Beitrag zu einem Tagungsband (4)
- Vortrag (4)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (96)
- Deutsch (11)
- Mehrsprachig (1)
Schlagworte
- ELISA (14)
- Affinity chromatography (8)
- Antibodies (8)
- Immunoassay (8)
- Antibody (7)
- IgG (7)
- Lab-on-a-chip (7)
- Mass spectrometry (7)
- Reproducibility (7)
- Biosensor (6)
- HPLC (6)
- Nitrotyrosine (6)
- Traceability (6)
- Amino acid analysis (5)
- Fluorescence (5)
- Immunosensor (5)
- LC-MS/MS (5)
- Metrology (5)
- Protein A (5)
- Tyrosine (5)
- Air pollution (4)
- Drone (4)
- Immunoassays (4)
- Immunoglobulins (4)
- Monoclonal antibody (4)
- Nitration (4)
- Peptides (4)
- Purification (4)
- Quality control (4)
- Reference material (4)
- AAA (3)
- Allergy (3)
- Biochip (3)
- Bioconjugation (3)
- Biosensors (3)
- Caffeine (3)
- Diagnostics (3)
- FPLC (3)
- Hybridoma (3)
- Immunocapture (3)
- Immunoprecipitation (3)
- Microarray (3)
- Microfluidics (3)
- Nanoparticles (3)
- Nitrogen oxides (3)
- PCR (3)
- Phenylalanine (3)
- Protein (3)
- Protein G (3)
- Quality Control (3)
- Reference materials (3)
- Regeneration (3)
- Ring resonator (3)
- Screening (3)
- Sequencing (3)
- Silanization (3)
- Terrorism (3)
- Validation (3)
- ABID (2)
- Affinity Chromatography (2)
- Affinity extraction (2)
- Affinitätschromatographie (2)
- Albumin (2)
- Allergene (2)
- Animal species differentiation (2)
- Antibody ID (2)
- Antibody coating (2)
- Antibody identification (2)
- Antikörper (2)
- Aromatic amino acid analysis (2)
- BSA (2)
- Biophotonics (2)
- Bioseparation (2)
- Calibration (2)
- Carbamazepine (2)
- Carrier (2)
- Carrier protein (2)
- Chemical evolution (2)
- Chirality (2)
- Chromatography (2)
- Click chemistry (2)
- Combinatorial chemistry (2)
- Copper (2)
- Degradation (2)
- Dimer (2)
- Dityrosine (2)
- Documentation (2)
- Explosives detection (2)
- Fish species (2)
- Fluoreszenz (2)
- Folding chirality (2)
- Glutaraldehyde (2)
- HTS (2)
- Hapten (2)
- Hydrolysis (2)
- Identity (2)
- Immunoaffinity extraction (2)
- Immunogen (2)
- LAMP (2)
- Linker (2)
- MALDI (2)
- Magnetic resonance imaging (2)
- Miniaturization (2)
- Mobile phase (2)
- Monoclonal Antibodies (2)
- Monolithic column (2)
- Multiplex (2)
- Multiplexing (2)
- Nickel (2)
- Open Science (2)
- Optical sensors (2)
- Oriented immobilization (2)
- Oxidation (2)
- Ozone (2)
- PEG (2)
- Passive Smart Dust (2)
- Peer review (2)
- Peptide (2)
- Peptide analysis (2)
- Peptide library (2)
- Peptide mass fingerprinting (2)
- Permethrin (2)
- Photonic sensors (2)
- Polyethylene glycol (2)
- Polyglycerol (2)
- Protein hydrolysis (2)
- Protein nitration (2)
- Protein quantification (2)
- Proximity-enhanced reaction (2)
- Qualitätskontrolle (2)
- Quantitative protein analysis (2)
- Remote Detection (2)
- Reproducibility crisis (2)
- SBA-15 (2)
- SPR (2)
- Sapphire (2)
- Security (2)
- Sequence coverage (2)
- Silicon photonics (2)
- Smart Dust (2)
- Synthetic peptides (2)
- TATP (2)
- Tryptophan (2)
- immunoassay (2)
- 150th anniversary (1)
- 150th anniversary of BAM (1)
- 2,5-dihydroxyacetophenone (1)
- 280 nm (1)
- 3R concept (1)
- 6xHis (1)
- AAAA (1)
- ABC (1)
- ADC (1)
- ATCUN (1)
- Aautomatisation (1)
- Abiogenesis (1)
- Absorption (1)
- Acidic cleavage (1)
- Acute myocardial infarction (1)
- Additive Fertigung (1)
- Additive Manufacturing (1)
- Adhesion (1)
- Adhesives (1)
- Adjuvantien (1)
- Adsorption (1)
- Aeroallergens (1)
- Affinity (1)
- Affinity Extraction (1)
- Affinity Separation (1)
- Affinity immobilization (1)
- Affinitätsextraktion (1)
- Aflatoxin (1)
- Agarose (1)
- Air filter samples (1)
- Air particulate matter (1)
- Air-segmented flow (1)
- Airport (1)
- Airport security (1)
- Alanine scan (1)
- Algal toxins (1)
- Allergentest (1)
- Allergie (1)
- Aluminum oxide (1)
- Ambient ionization (1)
- Amino acids (1)
- Amplification (1)
- Analysis (1)
- Analytical sciences (1)
- Analytische Expertise (1)
- Anatoxin-a (1)
- Anatoxin-a(s) (1)
- Animal welfare (1)
- Anthropocene (1)
- Anthropogenic markers (1)
- Antibody Purification (1)
- Antibody antigen complex (1)
- Antibody drug conjugate (1)
- Antibody light chain (1)
- Antibody quality (1)
- Antibody quantification (1)
- Antibody subclass (1)
- Antibody-gated indicator delivery (1)
- Antibody-gated indicator delivery systems (1)
- Antigen (1)
- Aromatic amino acid analysis aaaa (1)
- Array (1)
- Atmospheric aerosol (1)
- Augenbohne (1)
- Automated Purification (1)
- Aviation (1)
- BAM (1)
- BCA test (1)
- BODIPY-Farbstoffe (1)
- Back-side integration (1)
- Bacterial lysates (1)
- Basic solvent (1)
- Benchmarking study (1)
- Benzene-1,3,5-tricarboxylic acid (1)
- Bet v 1 (1)
- Betula pendula (1)
- Binder (1)
- Binding molecule (1)
- Binding strength (1)
- Bio-interaction (1)
- Bioanalysis (1)
- Biochemische Sensoren (1)
- Biochemistry (1)
- Bioconjugate (1)
- Bioinformatics (1)
- Bioluminescence (1)
- Biomarker (1)
- Biosensing (1)
- Biosensor development (1)
- Biotechnology (1)
- Biotoxins (1)
- Birch pollen allergen (1)
- Blindwert (1)
- Block copolymer (1)
- Blue-green algae (1)
- Bombs (1)
- Border surveillance (1)
- Borosilicate Glass (1)
- Borosilicatglas (1)
- Borosilikatglas (1)
- Bovine serum albumin (1)
- Bovine serum albumin (BSA) (1)
- Bradford (1)
- Bundesanstalt für Materialforschung und -prüfung (1)
- Byproducts (1)
- CMOS (1)
- COVID-19 (1)
- Carbamazepin (1)
- Cardiac troponin (1)
- Cardiovascular (1)
- Carrier load (1)
- Carrier-Material (1)
- Cellulose (1)
- Certified reference materials (1)
- Cetirizin (1)
- Cetirizine (1)
- Chelate (1)
- Chemical protein modification (1)
- Chemiluminescence (1)
- Chemosensor (1)
- Chicken antibodies (1)
- Chip (1)
- Chronic kidney disease (1)
- Citation (1)
- Citizen Science (1)
- Cleavage (1)
- Click reaction (1)
- Clone M2 (1)
- Clones (1)
- Cmos (1)
- Collection (1)
- Colorchanging Particles (1)
- Colorimetric Sensor (1)
- Colorimetric sensor particles (1)
- Column holder (1)
- Combinatorial peptide library (1)
- Combinatorial polymer libraries (1)
- Combustion (1)
- Commercialization (1)
- Compartmentalization (1)
- Competitive Immunoassay (1)
- Competitive immunoassay (1)
- Compound-independent calibration (1)
- Concentration step (1)
- Confetti (1)
- Confiscation (1)
- Conformation (1)
- Conjugates (1)
- Conjugation density (1)
- Conjugation ratio (1)
- Construction (1)
- Continuous Sensor (1)
- Contrast agent (1)
- Coproantibodies (1)
- Corona virus (1)
- Corundum (1)
- Covalent conjugation (1)
- Crisis (1)
- Cross-linking (1)
- Crosslinker (1)
- Customs (1)
- Cyanotoxins (1)
- Cylindrospermopsin (1)
- Cytochrome P450 CYP1A2 (1)
- Cytoplasm (1)
- DAMP (1)
- DAR (1)
- DHAP (1)
- DNA (1)
- DNA chip (1)
- DNA-Chip (1)
- Damage-associated molecular patterns (DAMPs) (1)
- Database (1)
- De novo peptide sequencing (1)
- Deep learning-based tools (1)
- Dendrimer (1)
- Derivatization (1)
- Detection (1)
- Diagnosis (1)
- Diagnostic Antibodies (1)
- Diesel (1)
- Diesel exhaust (1)
- Digital PCR (1)
- Digital immunoassay (1)
- Digitale PCR (1)
- Dimerization (1)
- Dissociation constant (1)
- Dityrosine crosslinking (1)
- Docking (1)
- Down Stream Processing (1)
- Downstream Processing (1)
- Downstream processing (1)
- Druckstabilität (1)
- Drug (1)
- Drug discovery (1)
- Drug search (1)
- Drug trafficking (1)
- Drug transporters (1)
- Drug-to-antibody ratio (1)
- EDTAD (1)
- ELISA methods (1)
- ESI MS (1)
- Editorial (1)
- Elastin-specific contrast agent ESMA (1)
- Element Specific Bioimaging Using Laser Ablation (1)
- Emergency (1)
- Enantiomeric excess ee (1)
- Encapsulation (1)
- Enhancement (1)
- Environment (1)
- Environmental Monitoring (1)
- Environmental analysis (1)
- Environmental monitoring (1)
- Environmental pollutants (1)
- Enzyme-linked immunosorbent assay (1)
- Epoxy (1)
- Equilibrium constant (1)
- Erdnuß (1)
- Error correction (1)
- Escherichia coli (1)
- Ethylenediaminetetraacetic acid (1)
- Etofenprox (1)
- Evanescent wave (1)
- Exhaust (1)
- Experiment (1)
- Explosive (1)
- Explosiven (1)
- Explosives (1)
- FLAG peptide (1)
- False Positives (1)
- Farbstoffe (1)
- Feces (1)
- Fischarten (1)
- Flow injection immunoassay (1)
- Fluorescence label (1)
- Formulation additives (1)
- Fragmentation (1)
- Functionalization (1)
- Gadofosveset (1)
- Gadolinium-based contrast agent (1)
- Gadovist (1)
- Gated hybrid material (1)
- Gated materials (1)
- Gesteuerten Nanopartikeln (1)
- Github (1)
- Glasmonolith (1)
- Glass (1)
- Glass Support (1)
- Glue (1)
- Glycidylethers (1)
- Gold particles (1)
- Gold surface (1)
- Grass pollen (1)
- HPLC-DAD (1)
- Hapten Immunoassay (1)
- Hapten immunoassay (1)
- Hard protein corona (1)
- Harmful algal blooms (1)
- Haselnuß (1)
- Hay fever (1)
- Hazard Detection (1)
- Hazardous substances (1)
- Heart attack (1)
- Heavy chains (1)
- Herceptin (1)
- Heterologous hapten (1)
- HexaHis-Tag (1)
- High pH (1)
- High-Speed (1)
- High-Speed Separations (1)
- High-speed biosensor (1)
- High-throughput (1)
- Highspeed (1)
- His6 (1)
- His8 (1)
- Histidine (1)
- Human Plasma (1)
- Human serum (1)
- Hybridisierung (1)
- Hydrochloric acid (1)
- Hydroxyl radicals (1)
- Hyperbranched polymer (1)
- IC50 (1)
- IMAC purification (1)
- IgE (1)
- IgG determination (1)
- IgY (1)
- Igg (1)
- Iinductively coupled plasma mass spectrometry (1)
- Illicit drug (1)
- Immobilisierung (1)
- Immunglobulin (1)
- Immunglobuline (1)
- Immunization monitoring (1)
- Immunochemical response optimization (1)
- Immunoglobulin E (1)
- Immunometric assay (1)
- Immunometric biosensor (1)
- Immunsensoren (1)
- Impact (1)
- Impurites (1)
- Indicator (1)
- Inductively Coupled Mass Spectroscopy (1)
- Inflammation (1)
- Inhibition (1)
- Inhibition assay (1)
- Insecticide (1)
- Interlaboratory studies (1)
- Internal standard (1)
- Internal standards (1)
- International drug trade (1)
- Iron disorders (1)
- Isotope dilution (1)
- Jahrestag (1)
- Kjeldahl (1)
- Klimaveränderung (1)
- Kontamination (1)
- Kreuzreaktion (1)
- Kreuzreaktivität (1)
- LC-MS (1)
- LC-UV absorbance (1)
- LCMSMS (1)
- LIF (1)
- Lab on a chip (1)
- Lab-on-a-Chip (1)
- Lab-on-chip (1)
- Label (1)
- Laborvergleichuntersuchungen (1)
- Ladder sequencing (1)
- Ladungstransfer (1)
- Lanthanide DOTA (1)
- Lanthaniden (1)
- Laser (1)
- Laser-induced fluorescence (1)
- Laser-induced plasma (1)
- Lateral flow assay (1)
- Lateral flow immunoassays (1)
- Lateral flow test (1)
- Latex particles (1)
- Lead identification (1)
- Lebensmittel (1)
- Library (1)
- Life sciences (1)
- Light chain (1)
- Light chains (1)
- Limit of detection (1)
- Liquid chromatography (1)
- Liver function tests (1)
- Low-cost (1)
- Luftverschmutzung (1)
- Luminol (1)
- MALDI-TOF (1)
- MALDI-TOF MS (1)
- MALDI-TOF-MS (1)
- MNPQ (1)
- MR Angiography (1)
- MST (1)
- Macroporous polymers (1)
- Mass Spectrometry (1)
- Massenspektrometrie (1)
- Material sciences (1)
- Material-binding Peptides (1)
- Mechanism (1)
- Mesoporous particles (1)
- Mesoporöse Materialien (1)
- Metal labeling (1)
- Metall-Markierung (1)
- Metalloprotein (1)
- Method (1)
- Microarrays (1)
- Microcystins (1)
- Microfluidic mixing (1)
- Microfluidic system (1)
- Micrometeorites (1)
- Microresonator (1)
- Microwave (1)
- Mikroparticles (1)
- Milch (1)
- Miller and Urey (1)
- Missing fragmentation sites (1)
- Molecular-MRI (1)
- Molekularbiologie (1)
- Monoclonal (1)
- Monoclonal Antibody (1)
- Monoclonal antibodies (1)
- Monolith (1)
- Multiplex methods (1)
- Murchison meteorite (1)
- Mycotoxin (1)
- NHS (1)
- NHS-Ester (1)
- NIR-Farbstoffe (1)
- NIST (1)
- NIST-mAb 8671 (1)
- Nanocarrier (1)
- Nanoparticle (1)
- Nanophotonics (1)
- Nanoscience (1)
- Narcotics (1)
- Natural products (1)
- Neoallergen (1)
- Neoepitopes (1)
- Nickel chelate (1)
- Nitrogen dioxide (1)
- Nodularins (1)
- Nonspecific binding (NSB) (1)
- Nucleocapsid (1)
- OBOC library (1)
- Oligomer (1)
- Oligomerization (1)
- On-chip screening (1)
- One-bead-one-compound library (1)
- Online biosensor (1)
- Online detection (1)
- Online software (1)
- Open data (1)
- Open science (1)
- Optical detection (1)
- Optoelectronic (1)
- Orbitrap (1)
- Organic peroxides (1)
- Ortho-Phthalaldehyde (1)
- Ovalbumin (1)
- Ozon (1)
- PALM (1)
- PIC technology (1)
- Partikel (1)
- Pattern recognition receptor (1)
- Peak overlap (1)
- Peakkapazität (1)
- Peptide Library (1)
- Peptide aptamers (1)
- Peptide binder (1)
- Peptide coverage (1)
- Peptide folding (1)
- Peptide library screening (1)
- Peptide losses (1)
- Periodate oxidation (1)
- Peroxidase (1)
- Pesticide (1)
- Pflanzenvirus (1)
- Pharmaceutical (1)
- Pharmaceuticals (1)
- Phenothrin (1)
- Phenylketonuria (1)
- Phl p 5 (1)
- Phleum pratense (1)
- Photonic Integrated Circuits (1)
- Photonic Sensor (1)
- Photonic biosensor (1)
- Plant virus (1)
- Plasma (1)
- Plastics (1)
- Point of inflection (1)
- Point-Of-Care-Diagnostics (1)
- Polishing (1)
- Pollen (1)
- Pollen extract (1)
- Pollutant (1)
- Polyclonal Antibodies (1)
- Polyethers (1)
- Polymer-binding Peptides (1)
- Polymers (1)
- Polypropylene (1)
- Porous rock (1)
- Prebiotic chemistry (1)
- Precision polymer sequencing (1)
- Preprocessing (1)
- Primer (1)
- Primordial soup (1)
- Probenahme (1)
- Protein Purification (1)
- Protein analysis (1)
- Protein conjugation (1)
- Protein content (1)
- Protein degradation (1)
- Protein folding (1)
- Protein nitration degree (1)
- Protein oligomer analysis (1)
- Protein oligomerization (1)
- Protein oligomers (1)
- Protein test (1)
- Protein-Quantifizierung (1)
- Proteinoid (1)
- Proteins (1)
- Proteomics (1)
- Pseudo peptides (1)
- Purity (1)
- Pyrethroid (1)
- QC (1)
- Quality (1)
- Quality assurance (1)
- Quantitative proteomics (1)
- RBD (1)
- Racemate (1)
- Reagenzien (1)
- Real-time measurement (1)
- Recombinant Antibody (1)
- Recombinant antibody (1)
- Recombinant protein (1)
- Recovery (1)
- Reductive amination (1)
- References (1)
- Referenzmaterialien (1)
- Reinheitsbestimmung (1)
- Reinigung (1)
- Remote detection (1)
- Replication (1)
- Replication crisis (1)
- Resonance wavelength shift (1)
- Reversibility (1)
- Ring resonators (1)
- Robustheit (1)
- Robustness (1)
- Round robin exercise (1)
- Round robin test (1)
- SARS-CoV-2 antibody (1)
- SBA-16 (1)
- SDS PAGE (1)
- SI traceability (1)
- Saliva (1)
- Saxitoxins (1)
- Schlangenbohne (1)
- Schnellmethoden (1)
- Schnelltests (1)
- Scientific publication (1)
- Segregation (1)
- Selectivity (1)
- Selektivität (1)
- Self-assembled monolayer (1)
- Self-assembled monolayer (SAM) (1)
- Self-assembled monolayers (SAM) (1)
- Self-assembly (1)
- Semtex (1)
- Sensitivity (1)
- Sensor (1)
- Separation (1)
- Sequence-defined oligomer (1)
- Sequencing algorithm (1)
- Serum (1)
- Signal amplification (1)
- Silicon Photonics (1)
- Single molecule (1)
- Sintered Material (1)
- Size exclusion chromatography (1)
- Smartphone readout device (1)
- Sodium chloride method (1)
- Soft protein corona (1)
- Software (1)
- Solid phase (1)
- Solid support (1)
- Solid-binding Peptides (1)
- Solid-phase extraction (SPE) (1)
- Solubilizer (1)
- Sommerschule (1)
- Special issue (1)
- Spezifität (1)
- Spike protein (1)
- Sprengstoffe (1)
- Spurensicherung (1)
- Stabilization (1)
- Stable isotope labeling (1)
- Standardisation (1)
- Standardisierung (1)
- Standardverfahren (1)
- Stationäre Phase (1)
- Stickoxide (1)
- Structure (1)
- Sulfo-NHS (1)
- Sulfur (1)
- Sulfuric acid (1)
- Supernatant (1)
- Surface Activation (1)
- Surface chemistry (1)
- Surface derivatization (1)
- Surface plasmon resonance (1)
- Surface water (1)
- Surface-plasmon resonance (1)
- Surrogate citations (1)
- TLR4 activation (1)
- TNT (1)
- Target (1)
- Technology transfer (1)
- Terephthalic acid (1)
- Test midpoint (1)
- Test strip analysis (1)
- Teststreifen (1)
- Tetranitromethane (1)
- Therapeutic Antibodies (1)
- Tholins (1)
- Titan-Halterung (1)
- Toll-like receptor 4 (1)
- Topical collection: Analytical Methods and Applications in the Materials and Life Sciences (1)
- Toxicity (1)
- Toxicity test (1)
- Trastuzumab (1)
- Trennung (1)
- Triacetone triperoxide (1)
- Trimer (1)
- Trinitrotoluene (1)
- Tripeptides (1)
- Trust (1)
- Trypsin (1)
- Tryptic digest (1)
- Type-I pyrethroids (1)
- Ultrasensitive (1)
- Upscaling (1)
- Vibrio fischeri (1)
- Vigna unguiculata (1)
- Visualization (1)
- Vor-Ort-Analytik (1)
- Wastewater marker (1)
- Water (1)
- Wattestäbchen (1)
- Waveguide (1)
- Wipe test (1)
- Zenodo (1)
- affinity chromatography (1)
- antibodies (1)
- antibody (1)
- bioanalysis (1)
- bioisosteric replacement (1)
- biokompatibel (1)
- cross-reactivity (1)
- explosives (1)
- gesintert (1)
- hapten (1)
- immunoaffinity (1)
- irreproducibility (1)
- ligand binding assay (1)
- monoclonal antibody (1)
- non-specific binding (1)
- pH-Abhängigkeit (1)
- paper retraction (1)
- peer reviewimmunochemistry (1)
- quality control (1)
- replication (1)
- reproducibility crisis (1)
- sample preparation (1)
- security (1)
- selectivity (1)
- self-replication (1)
- terrorism (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (63)
- 1.5 Proteinanalytik (63)
- 1.9 Chemische und optische Sensorik (9)
- 6 Materialchemie (8)
- 1.8 Umweltanalytik (7)
- 6.3 Strukturanalytik (7)
- 1.1 Anorganische Spurenanalytik (6)
- 8 Zerstörungsfreie Prüfung (4)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (4)
- 1.4 Prozessanalytik (3)
Eingeladener Vortrag
- nein (4)
Affinity extraction is one of the most powerful separation methods. Regarded to be indispensable in some research fields, such as proteomics, the application in other fields is still scarce or even waning. Many researchers fear the perceived complexity, cost and unreliability of this approach. The presentation gives a broad overview of the most important methods and discusses some important points for their implementation. Having considered these aspects, it should be easier to establish an affinity separation approach to resolve challenging analytical questions.
In the field of animal species differentiation, work on standardizing methods has been intensified in Germany in recent years, not least due to the horsemeat scandal in 2013. Even though there are now hardly ever any positive findings anymore in examinations to detect horse adulterations in foods such as lasagne, animal species differentiation altogether ranks high in detecting adulteration of foods. This article, therefore, summarises the current status of analytical techniques used in Germany with standardization at German level. It has been established by the working group "Biochemical and Molecular Biological Analytics" of the Lebensmittelchemische Gesellschaft (Food Chemistry Society within the German Chemical Society) with support of experts in the working group “Molecular biology techniques for differentiating plant and animal species" (§64 of the German Food and Feed Code - LFGB) and the "Immunology and molecular biology" task force of the food hygiene and food of animal origin working group (ALTS), both from Germany.
Hepcidin-25 was identified as the main iron regulator in the human body, and it by binds to the sole iron-exporter ferroportin. Studies showed that the N-terminus of hepcidin is responsible for this interaction, the same N-terminus that encompasses a small copper(II)-binding site known as the ATCUN (amino-terminal Cu(II)- and Ni(II)-binding) motif. Interestingly, this copper-binding property is largely ignored in most papers dealing with hepcidin-25. In this context, detailed investigations of the complex formed between hepcidin-25 and copper could reveal insight into its biological role. The present work focuses on metal-bound hepcidin-25 that can be considered the biologically active form. The first part is devoted to the reversed-phase chromatographic separation of copper-bound and copper-free hepcidin-25 achieved by applying basic mobile phases containing 0.1% ammonia. Further, mass spectrometry (tandem mass spectrometry (MS/MS), high-resolution mass spectrometry HRMS)) and nuclear magnetic resonance (NMR) spectroscopy were employed to characterize the copper-peptide. Lastly, a three-dimensional (3D)model of hepcidin-25with bound copper(II) is presented. The identification of metal complexes and potential isoforms and isomers, from which the latter usually are left undetected by mass spectrometry, led to the conclusion that complementary analytical methods are needed to characterize a peptide calibrant or reference material comprehensively. Quantitative nuclear magnetic resonance (qNMR), inductively-coupled plasma mass spectrometry (ICP-MS), ion-mobility spectrometry (IMS) and chiral amino acid analysis (AAA) should be considered among others.
Homochirality is an obvious feature of life on Earth. On the other hand, extraterrestrial samples contain largely racemic compounds. The same is true for any common organic synthesis. Therefore, it has been a perplexing puzzle for decades how these racemates could have formed enantiomerically enriched fractions as a basis for the origin of homochiral life forms. Numerous hypotheses have been put forward as to how preferentially homochiral molecules could have formed and accumulated on Earth. In this article, it is shown that homochirality of the abiotic organic pool at the time of formation of the first self-replicating molecules is not necessary and not even probable. It is proposed to abandon the notion of a molecular ensemble and to focus on the level of individual molecules. Although the formation of the first self-replicating, most likely homochiral molecule, is a seemingly improbable event, on a closer look, it is almost inevitable that some homochiral molecules have formed simply on a statistical basis. In this case, the non-selective leap to homochirality would be one of the first steps in chemical evolution directly out of a racemic “ocean”. Moreover, most studies focus on the chirality of the primordial monomers with respect to an asymmetric carbon atom. However, any polymer with a minimal size that allows folding to a secondary structure would spontaneously lead to asymmetric higher structures (conformations). Most of the functions of these polymers would be influenced by this inherently asymmetric folding. Furthermore, a concept of physical compartmentalization based on rock nanopores in analogy to nanocavities of digital immunoassays is introduced to suggest that complex cell walls or membranes were also not required for the first steps of chemical evolution. To summarize, simple and universal mechanisms may have led to homochiral self-replicating systems in the context of chemical evolution. A homochiral monomer pool is deemed unnecessary and probably never existed on primordial Earth.
The illegal use of explosives by terrorists and other criminals is an increasing issue in public spaces, such as airports, railway stations, highways, sports venues, theaters, and other large buildings. Security in these environments can be achieved by different means, including the installation of scanners and other analytical devices to detect ultra-small traces of explosives in a very short time-frame to be able to take action as early as possible to prevent the detonation of such devices. Unfortunately, an ideal explosive detection system still does not exist, which means that a compromise is needed in practice. Most detection devices lack the extreme analytical sensitivity, which is nevertheless necessary due to the low vapor pressure of nearly all explosives. In addition, the rate of false positives needs to be virtually zero, which is also very difficult to achieve. Here we present an immunosensor system based on kinetic competition, which is known to be very fast and may even overcome affinity limitation, which impairs the performance of many traditional competitive assays. This immunosensor consists of a monolithic glass column with a vast excess of immobilized hapten, which traps the fluorescently labeled antibody as long as no explosive is present. In the case of the explosive 2,4,6-trinitrotoluene (TNT), some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and chip-based mixing-devices and flow-cells. The system achieved limits of detection of 1 pM (1 ppt) of the fluorescent label and around 100 pM (20 ppt) of TNT. The total assay time is less than 8 min. A cross-reactivity test with 5000 pM solutions showed no signal by pentaerythritol tetranitrate (PETN), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX). This immunosensor belongs to the most sensitive and fastest detectors for TNT with no significant cross-reactivity by non-related compounds. The consumption of the labeled antibody is surprisingly low: 1 mg of the reagent would be sufficient for more than one year of continuous biosensor operation.
Chemical modifications such as nitration and cross-linking may enhance the allergenic potential of proteins. The kinetics and mechanisms of the underlying chemical processes, however, are not yet well understood. Here, we present a size-exclusion chromatography/spectrophotometry method (SEC-HPLC-DAD) that allows a simultaneous detection of mono-, di-, tri-, and higher protein oligomers, as well as their individual nitration degrees (NDs). The ND results of proteins from this new method agree well with the results from an alternative well-established method, for the analysis of tetranitromethane (TNM)- and nitrogen dioxide and ozone (NO2/O3)-nitrated protein samples. Importantly, the NDs for individual oligomer fractions can be obtained from the new method, and also, we provide a proof of principle for the calculation of the concentrations for individual protein oligomer fractions by their determined NDs, which will facilitate the investigation of the kinetics and mechanism for protein tyrosine nitration and cross-linking.
A new type of biodetector was designed based on a bioluminescence test with the bacterium Vibrio fischeri performed in a liquid continuous flow-through system. Here we describe the modification of a commercial tube luminescence detector to work in the flow mode by building a new flow cell holder and a new case including top cover to connect the flow cell with the waste and the incubation capillary in a light-proof manner. As different samples were injected successively it was necessary to keep the individual peaks separated. This was done using an air-segmented flow in the reaction coil. To afford fast screening, the incubation time of the sample and the Vibrio fischeri, which equaled the dead time of the detection system, was set at 5.6 min. Rapid monitoring of toxic substances is achieved by using 20 µL of sample and flow-rates of 110150 µL min-1. As a proof-of-principle, we show results for the detection of five selected di-, tri- and tetrachlorophenols at different concentrations varying from 1 to 200 mg L-1. Calculation of inhibition rates and EC50 values were performed and compared with corresponding values from the DIN EN ISO 11348-2 microplate format. Compared with the latter, the inhibition rates obtained with our flow-through biodetector for the compounds tested were generally about twofold lower, but importantly, a much faster detection is possible.
Besides protein identification via mass spectrometric methods, protein and peptide quantification has become more and more important in order to tackle biological questions. Methods like differential gel electrophoresis or enzyme-linked immunosorbent assays have been used to assess protein concentrations, while stable isotope labeling methods are also well established in quantitative proteomics. Recently, we developed metalcoded affinity tagging (MeCAT) as an alternative for accurate and sensitive quantification of peptides and
proteins. In addition to absolute quantification via inductively coupled plasma mass spectrometry, MeCAT also enables sequence analysis via electrospray ionization tandem mass spectrometry. In the current study, we developed a new labeling approach utilizing an iodoacetamide MeCAT reagent (MeCAT-IA). The MeCAT-IA approach shows distinct advantages over the previously used MeCAT with maleinimide reactivity such as higher labelling efficiency and the lack of diastereomer formation during labeling. Here, we present a careful characterization of this new method focusing on the labeling process, which yields complete tagging with an excess of reagent of 1.6 to 1, less complex chromatographic behavior, and fragmentation characteristics of the tagged peptides using the iodoacetamide MeCAT reagent.
CMOS-Compatible Silicon Photonic Sensor for Refractive Index Sensing Using Local Back-Side Release
(2020)
Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line. The sensor is based on a micro-ring resonator and is fabricated on wafer-level using a CMOS technology. We revealed a ring resonator sensitivity for homogeneous sensing of 106 nm/RIU.
The employment of type-I pyrethroids for airplane disinfection in recent years underlines the necessity to develop sensing schemes for the rapid detection of these pesticides directly at the point-of-use. Antibody-gated indicator-releasing materials were thus developed and implemented with test strips for lateral-flow assay-based analysis employing a smartphone for readout. Besides a proper matching of pore sizes and gating macromolecules, the functionalization of both the material's outer surface as well as the strips with PEG chains enhanced system performance. This simple assay allowed for the detection of permethrin as a target molecule at concentrations down to the lower ppb level in less than 5 minutes.
Set them free: Brightly fluorescent indicators that are loaded into mesoporous silica nanoparticle carriers, capped with bulky antibodies, are released into the lateral flow of a test strip upon analyte arrival. Integration of the system into a rapid, simple flow test with fluorescence readout is applied for the selective and sensitive determination of the presence of triacetone triperoxide (TATP) as a prototype small-molecule analyte (see figure).
MALDI-TOF-MS-Based Identification of Monoclonal Murine Anti-SARS-CoV-2 Antibodies within One Hour
(2022)
During the SARS-CoV-2 pandemic, many virus-binding monoclonal antibodies have been developed for clinical and diagnostic purposes. This underlines the importance of antibodies as universal bioanalytical reagents. However, little attention is given to the reproducibility crisis that scientific studies are still facing to date. In a recent study, not even half of all research antibodies mentioned in publications could be identified at all. This should spark more efforts in the search for practical solutions for the traceability of antibodies. For this purpose, we used 35 monoclonal antibodies against SARS-CoV-2 to demonstrate how sequence-independent antibody identification can be achieved by simple means applied to the protein. First, we examined the intact and light chain masses of the antibodies relative to the reference material NIST-mAb 8671. Already half of the antibodies could be identified based solely on these two parameters. In addition, we developed two complementary peptide mass fingerprinting methods with MALDI-TOF-MS that can be performed in 60 min and had a combined sequence coverage of over 80%. One method is based on the partial acidic hydrolysis of the protein by 5 mM of sulfuric acid at 99 degrees C. Furthermore, we established a fast way for a tryptic digest without an alkylation step. We were able to show that the distinction of clones is possible simply by a brief visual comparison of the mass spectra. In this work, two clones originating from the same immunization gave the same fingerprints. Later, a hybridoma sequencing confirmed the sequence identity of these sister clones. In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0. This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
We introduce a passive smart dust concept as a novel solution for environmental monitoring. Utilizing chemical reagents like colorimetric indicators and other chemosensors, these particles detect varying environmental conditions. We developed paper-based sensors that are both cost-effective and eco-friendly. In practical tests, these sensors, dispersed over a designated area, successfully identified hazardous substances by changing their color when exposed to acids or bases. This color change was remotely detectable using a drone-mounted color camera. The data thus obtained was processed through specialized software, accurately pinpointing areas of contamination. This method proves the efficacy and scalability of passive smart dust technology for real-time, environmentally sustainable remote sensing of hazardous materials
Fast and robust purification of antibodies from human serum with a new monolithic protein A column
(2017)
The use of antibodies is becoming more and more important. Therewith the need for fast and robust methods for their purification and columns with a long lifetime is growing. In this application, we describe a fast and robust protein A affinity chromatography method with a new monolithic column. Antibodies were successfully purified in less than 1.5 minutes with a flowrate of 5 mL/min highlighting the advantages of this column and method.
Chemical modification by peroxynitrite enhances TLR4 activation of the grass pollen allergen Phl p 5
(2023)
The chemical modification of aeroallergens by reactive oxygen and nitrogen species (ROS/RNS) may contribute to the growing prevalence of respiratory allergies in industrialized countries. Post-translational modifications can alter the immunological properties of proteins, but the underlying mechanisms and effects are not well understood. In this study, we investigate the Toll-like receptor 4 (TLR4) activation of the major birch and grass pollen allergens Bet v 1 and Phl p 5, and how the physiological oxidant peroxynitrite (ONOO–) changes the TLR4 activation through protein nitration and the formation of protein dimers and higher oligomers. Of the two allergens, Bet v 1 exhibited no TLR4 activation, but we found TLR4 activation of Phl p 5, which increased after modification with ONOO– and may play a role in the sensitization against this grass pollen allergen. We attribute the TLR4 activation mainly to the two-domain structure of Phl p 5 which may promote TLR4 dimerization and activation. The enhanced TLR4 signaling of the modified allergen indicates that the ONOO–-induced modifications affect relevant protein-receptor interactions. This may lead to increased sensitization to the grass pollen allergen and thus contribute to the increasing prevalence of allergies in the Anthropocene, the present era of globally pervasive anthropogenic influence on the environment.
Rapid testing methods for the use directly at apointof need are expected to unfold their true potential especiallywhen offering adequate capabilities for the simultaneousmeasurement of multiple analytes of interest. Considering theunique modularity,high sensitivity,and selectivity of antibody-gated indicator delivery (gAID) systems,amultiplexed assayfor three small-molecule explosives (TATP, TNT,PETN) wasthus developed, allowing to detect the analytes simultaneouslywith asingle test strip at lower ppb concentrations in the liquidphase in < 5min using afluorescence reader or asmartphonefor readout. While the TNT and PETN systems were newlydeveloped here,all the three systems also tolerated harshermatrices than buffered aqueous model solutions.Besidesasingle-track strip,the outstanding modularity of the hybridbiosensor materials in combination with strip-patterningtechnologies allowed us to obtain amultichannel strip inastraightforwardmanner,offering comparable analyticalperformance while allowing to be tailored even more to theusersneed.
An improved antibody against the explosive pentaerythritol tetranitrate (PETN) was developed. The immunogen was designed by the concept of bioisosteric replacement, which led to an excellent polyclonal antibody with extreme selectivity and immunoassays of very good sensitivity. Compounds such as nitroglycerine, 2,4,6-trinitrotoluene, 1,3,5-trinitrobenzene, hexogen (RDX), 2,4,6-trinitroaniline, 1,3-dinitrobenzene, octogen (HMX), triacetone triperoxide (TATP), ammonium nitrate, 2,4,6-trinitrophenol and nitrobenzene were tested for potential cross-reactivity. The detection limit of a competitive enzyme-linked immunosorbent assay (ELISA) was determined to be around 0.5 µg/L. The dynamic range of the assay was found to be between 1 µg/L and 1000 µg/L, covering a concentration range of three decades. This work shows the successful application of the bioisosteric concept in immunochemistry by exchange of a nitroester to a carbonate diester. The antiserum might be used for the development of quick tests, biosensors, microtitration plate immunoassays, microarrays and other analytical methods for the highly sensitive detection of PETN, an explosive frequently used by terrorists, exploiting the extreme difficulty of its detection.
Environmental pollutants like fine particulate matter can cause adverse health effects through oxidative stress and inflammation. Reactive oxygen and nitrogen species (ROS/RNS) such as peroxynitrite can chemically modify proteins, but the effects of such modifications on the immune system and human health are not well understood. In the course of inflammatory processes, the Toll-like receptor 4 (TLR4) can sense damage-associated molecular patterns (DAMPs). Here, we investigate how the TLR4 response and pro-inflammatory potential of the proteinous DAMPs α-Synuclein (α-Syn), heat shock protein 60 (HSP60), and high-mobility-group box 1 protein (HMGB1), which are relevant in neurodegenerative and cardiovascular diseases, changes upon chemical modification with peroxynitrite.
For the peroxynitrite-modified proteins, we found a strongly enhanced activation of TLR4 and the pro-inflammatory transcription factor NF-κB in stable reporter cell lines as well as increased mRNA expression and secretion of the pro-inflammatory cytokines TNF-α, IL-1β, and IL-8 in human monocytes (THP-1). This enhanced activation of innate immunity via TLR4 is mediated by covalent chemical modifications of the studied DAMPs.
Our results show that proteinous DAMPs modified by peroxynitrite more potently amplify inflammation via TLR4 activation than the native DAMPs, and provide first evidence that such modifications can directly enhance innate immune responses via a defined receptor. These findings suggest that environmental pollutants and related ROS/RNS may play a role in promoting acute and chronic inflammatory disorders by structurally modifying the body's own DAMPs. This may have important consequences for chronic neurodegenerative, cardiovascular or gastrointestinal diseases that are prevalent in modern societies, and calls for action, to improve air quality and climate in the Anthropocene.
Comprehensive evaluation of peptide de novo sequencing tools for monoclonal antibody assembly
(2023)
Monoclonal antibodies are biotechnologically produced proteins with various applications in research, therapeutics and diagnostics. Their ability to recognize and bind to specific molecule structures makes them essential research tools and therapeutic agents. Sequence information of antibodies is helpful for understanding antibody–antigen interactions and ensuring their affinity and specificity. De novo protein sequencing based on mass spectrometry is a valuable method to obtain the amino acid sequence of peptides and proteins without a priori knowledge. In this study, we evaluated six recently developed de novo peptide sequencing algorithms (Novor, pNovo 3, DeepNovo, SMSNet, PointNovo and Casanovo), which were not specifically designed for antibody data. We validated their ability to identify and assemble antibody sequences on three multi-enzymatic data sets. The deep learning-based tools Casanovo and PointNovo showed an increased peptide recall across different enzymes and data sets compared with spectrum-graph-based approaches. We evaluated different error types of de novo peptide sequencing tools and their performance for different numbers of missing cleavage sites, noisy spectra and peptides of various lengths. We achieved a sequence coverage of 97.69–99.53% on the light chains of three different antibody data sets using the de Bruijn assembler ALPS and the predictions from Casanovo. However, low sequence coverage and accuracy on the heavy chains demonstrate that complete de novo protein sequencing remains a challenging issue in proteomics that requires improved de novo error correction, alternative digestion strategies and hybrid approaches such as homology search to achieve high accuracy on long protein sequences.
BioPIC - Integration of Biosensors based on Photonic Integrated Circuits by Local-Backside Etching
(2020)
Silicon photonic sensors are promising candidates for lab-on-a-chip solutions with versatile applications and scalable production prospects using complementary metal-oxide semiconductor (CMOS) fabrication methods. However, the widespread use has been hindered because the sensing area adjoins optical and electrical components making packaging and sensor handling challenging. In this work, a local back-side release of the photonic sensor is employed, enabling a separation of the sensing area from the rest of the chip. This approach allows preserving the compatibility of photonic integrated circuits in the front-end of line and metal interconnects in the back-end of line.
A new class of boron-dipyrromethene (BDP or BODIPY) dyes was obtained by phenanthrene fusion to the β-pyrrole positions, absorbing in the wavelength range of important laser sources. Despite a 'propeller-like' distorted structure in the crystalline state, the chromophore absorbs (log ε ≥ 5) and fluoresces (Φf ≥ 0.8) strongly and can be easily turned into a fluorescence light-up probe. Incorporation into latex beads produces bright and photostable single-dye and Förster Resonance Energy Transfer (FRET) particles for microscopy applications.
Mass spectrometry-based methods play a crucial role in the quantification of the main iron metabolism regulator hepcidin by singling out the bioactive 25-residue peptide from the other naturally occurring N-truncated isoforms (hepcidin-20, -22, -24), which seem to be inactive in iron homeostasis. However, several difficulties arise in the MS analysis of hepcidin due to the sticky character of the peptide and the lack of suitable standards. Here, we propose the use of amino- and fluoro-silanized autosampler vials to reduce hepcidin interaction to laboratory glassware surfaces after testing several types of vials for the preparation of stock solutions and serum samples for isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Furthermore, we have investigated two sample preparation strategies and two chromatographic separation conditions with the aim of developing an LC-MS/MS method for the sensitive and reliable quantification of hepcidin-25 in serum samples. A chromatographic separation based on usual acidic mobile phases was compared with a novel approach involving the separation of hepcidin-25 with solvents at high pH containing 0.1% of ammonia. Both methods were applied to clinical samples in an intra-laboratory comparison of two LC-MS/MS methods using the same hepcidin-25 calibrators with good correlation of the results. Finally, we recommend an LC-MS/MS-based quantification method with a dynamic range of 0.5–40 μg/L for the assessment of hepcidin-25 in human serum that uses TFA-based mobile phases and silanized glass vials.
A recent Opinion Article by Jan Voskuil (JV), Aeonian Biotech, discussed the challenges in validation of research antibodies. It was openly peer reviewed by Michael Weller (MW), Federal Institute for Materials Research and Testing (BAM), Germany. In this blog, both discuss these challenges, the reproducibility crisis and open data.
The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue for public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 7 ppt (23 pM) of cocaine with a response time of 90 s and a total assay time below 3 min. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement.
The trafficking of illegal drugs by criminal networks at borders, harbors, or airports is an increasing issue in public health as these routes ensure the main supply of illegal drugs. The prevention of drug smuggling, including the installation of scanners and other analytical devices to detect ultra-small traces of drugs within a reasonable time frame, remains a challenge. The presented immunosensor is based on a monolithic affinity column with a large excess of immobilized hapten, which traps fluorescently labeled antibodies as long as the analyte cocaine is absent. In the presence of the drug, some binding sites of the antibody will be blocked, which leads to an immediate breakthrough of the labeled protein, detectable by highly sensitive laser-induced fluorescence with the help of a Peltier-cooled complementary metal-oxide-semiconductor (CMOS) camera. Liquid handling is performed with high-precision syringe pumps and microfluidic chip-based mixing devices and flow cells. The biosensor achieved limits of detection of 23 pM (7 ppt) of cocaine with a response time of 90 seconds and a total assay time below 3 minutes. With surface wipe sampling, the biosensor was able to detect 300 pg of cocaine. This immunosensor belongs to the most sensitive and fastest detectors for cocaine and offers near-continuous analyte measurement.
Therapeutische Antikörper sind innerhalb weniger Jahre zur wichtigsten pharmazeutischen Produktklasse aufgestiegen. Für 2023 werden weltweite Umsätze von über 200 Milliarden USD erwartet. Auch diagnostische Antikörper sind mittlerweile unverzichtbare Produkte, auf deren Basis zahllose Immunoassays und andere Schnelltests entwickelt wurden. Neben der bereits sehr aufwendigen Herstellung von Antikörpern ist deren Aufreinigung aus komplexen Zellkulturmedien oder Blutseren und -plasmen zu einem Engpass in der Produktion und Nutzung dieser komplexen Proteine geworden. Schnelle und einfache Reinigungsmethoden für Antikörper sind daher sehr gefragt.
Background:
Molecular-MRI is a promising imaging modality for the assessment of abdominal aortic aneurysms (AAAs). Interleukin-1β (IL-1β) represents a new therapeutic tool for AAA-treatment, since pro-inflammatory cytokines are key-mediators of inflammation. This study investigates the potential of molecular-MRI to evaluate therapeutic effects of an anti-IL-1β-therapy on AAA-formation in a mouse-model.
Methods:
Osmotic-minipumps were implanted in apolipoprotein-deficient-mice (N = 27). One group (Ang-II+01BSUR group, n = 9) was infused with angiotensin-II (Ang-II) for 4 weeks and received an anti-murine IL-1β-antibody (01BSUR) 3 times. One group (Ang-II-group, n = 9) was infused with Ang-II for 4 weeks but received no treatment. Control-group (n = 9) was infused with saline and received no treatment. MR-imaging was performed using an elastin-specific gadolinium-based-probe (0.2 mmol/kg).
Results:
Mice of the Ang-II+01BSUR-group showed a lower aortic-diameter compared to mice of the Ang-II-group and control mice (p < 0.05). Using the elastin-specific-probe, a significant decrease in elastin-destruction was observed in mice of the Ang-II+01BSUR-group. In vivo MR-measurements correlated well with histopathology (y = 0.34x-13.81, R2 = 0.84, p < 0.05), ICP-MS (y = 0.02x+2.39; R2 = 0.81, p < 0.05) and LA-ICP-MS. Immunofluorescence and western-blotting confirmed a reduced IL-1β-expression.
Conclusions:
Molecular-MRI enables the early visualization and quantification of the anti-inflammatory-effects of an IL-1β-inhibitor in a mouse-model of AAAs. Responders and non-responders could be identified early after the initiation of the therapy using molecular-MRI.
High performance liquid chromatography (HPLC) was hyphenated with a previously reported carbamazepine-specific enzyme-linked immunosorbent assay (ELISA) as a screening approach to water analysis in order to identify possible interferences from transformation products. Treated wastewater was analysed and three substances were recognized by the antibody besides carbamazepine: the metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 2-hydroxycarbamazepine plus the structurally not obviously related antihistamine cetirizine. The molar cross-reactivity against cetirizine was found to be pH-dependent and assessed to be 400% at pH 4.5 and 22% at pH 10.5. Performing the ELISA at pH 10.5 greatly improved the accuracy when carbamazepine was determined in surface and wastewater samples.
The primary screening of hybridoma cells is a time-critical and laborious step during the development of monoclonal antibodies. Often critical errors occur in this phase, which supports the notion that the generation of monoclonal antibodies with hybridoma technology is difficult to control and hence a risky venture. We think that it is crucial to improve the screening process to eliminate most of the immanent deficits of the conventional approach. With this new microarray-based procedure, several advances could be achieved: Selectivity for excellent binders, high throughput, reproducible signals, avoidance of misleading avidity (multivalency) effects, and simultaneous performance of competition experiments. The latter can directly be used to select clones of desired cross-reactivity properties. In this paper, a model system with two excellent clones against carbamazepine, two weak clones and blank supernatant has been designed to examine the effectiveness of the new system. The excellent clones could be detected largely independent of the IgG concentration, which is unknown during the clone screening since the determination and subsequent adjustment of the antibody concentration is not possible in most cases. Furthermore, in this approach, the enrichment, isolation, and purification of IgG for characterization is not necessary. Raw cell culture supernatant can be used directly, even when fetal calf serum (FCS) or other complex media had been used. In addition, an improved method for the oriented antibody-immobilization on epoxy-silanized slides is presented. Based on the results of this model system, we conclude that this approach should be preferable to most other protocols leading to many of false positives, causing expensive and lengthy confirmation steps to weed out the poor clones.
Triacetone triperoxide (TATP) is a primary explosive, which was used in various terrorist attacks in the past. For the development of biosensors, immunochemical µ-TAS, electronic noses, immunological test kits, or test strips, the availability of antibodies of high quality is crucial. Recently, we presented the successful immunization of mice, based on the design, synthesis, and conjugation of a novel TATP derivative. Here, the long-term immunization of rabbits is shown, which resulted in antibodies of extreme selectivity and more than 1,000 times better affinity in relation to the antibodies from mice. Detection limits below 10 ng L-1 (water) were achieved. The working range covers more than four decades, calculated from a precision profile. The cross-reactivity tests revealed an extraordinary selectivity of the antibodies—not a single compound could be identified as a relevant cross-reactant. The presented immunoreagent might be a major step for the development of highly sensitive and selective TATP detectors particularly for security applications.
Peptide pools consist of short amino acid sequences and have proven to be versatile tools in various research areas in immunology and clinical applications. They are commercially available in many different compositions and variants. However, unlike other reagents that consist of only one or a few compounds, peptide pools are highly complex products which makes their quality control a major challenge. Quantitative peptide analysis usually requires sophisticated methods, in most cases isotope-labeled standards and reference materials. Usually, this would be prohibitively laborious and expensive. Therefore, an approach is needed to provide a practical and feasible method for quality control of peptide pools. With insufficient quality control, the use of such products could lead to incorrect experimental results, worsening the well-known reproducibility crisis in the biomedical sciences. Here we propose the use of ultra-high performance liquid chromatography (UHPLC) with two detectors, a standard UV detector at 214 nm for quantitative analysis and a high-resolution mass spectrometer (HRMS) for identity confirmation. To be cost-efficient and fast, quantification and identification are performed in one chromatographic run. An optimized protocol is shown, and different peak integration methods are compared and discussed. This work was performed using a peptide pool known as CEF advanced, which consists of 32 peptides derived from cytomegalovirus (CMV), Epstein–Barr virus (EBV) and influenza virus, ranging from 8 to 12 amino acids in length.
The affinity constant, also known as the equilibrium constant, binding constant, equilibrium association constant, or the reciprocal value, the equilibrium dissociation constant (Kd), can be considered as one of the most important characteristics for any antibody–antigen pair. Many methods based on different technologies have been proposed and used to determine this value. However, since a very large number of publications and commercial datasheets do not include this information, significant obstacles in performing such measurements seem to exist. In other cases where such data are reported, the results have often proved to be unreliable. This situation may indicate that most of the technologies available today require a high level of expertise and effort that does not seem to be available in many laboratories. In this paper, we present a simple approach based on standard immunoassay technology that is easy and quick to perform. It relies on the effect that the molar IC50 approaches the Kd value in the case of infinitely small concentrations of the reagents. A two-dimensional dilution of the reagents leads to an asymptotic convergence to Kd. The approach has some similarity to the well-known checkerboard titration used for the optimization of immunoassays. A well-known antibody against the FLAG peptide, clone M2, was used as a model system and the results were compared with other methods. This approach could be used in any case where a competitive assay is available or can be developed. The determination of an affinity constant should belong to the crucial parameters in any quality control of antibody-related products and assays and should be mandatory in papers using immunochemical protocols.
Preactivation crosslinking – An efficient method for the oriented immobilization of antibodies
(2019)
Crosslinking of proteins for their irreversible immobilization on surfaces is a proven and popular method. However, many protocols lead to random orientation and the formation of undefined or even inactive by-products. Most concepts to obtain a more targeted conjugation or immobilization requires the recombinant modification of at least one binding partner, which is often impractical or prohibitively expensive. Here a novel method is presented, which is based on the chemical preactivation of Protein A or G with selected conventional crosslinkers. In a second step, the antibody is added, which is subsequently crosslinked in the Fc part. This leads to an oriented and covalent immobilization of the immunoglobulin with a very high yield. Protocols for Protein A and Protein G with murine and human IgG are presented. This method may be useful for the preparation of columns for affinity chromatography, immunoprecipitation, antibodies conjugated to magnetic particles, permanent and oriented immobilization of antibodies in biosensor systems, microarrays, microtitration plates or any other system, where the loss of antibodies needs to be avoided, and maximum binding capacity is desired. This method is directly applicable even to antibodies in crude cell culture supernatants, raw sera or protein-stabilized antibody preparations without any purification nor enrichment of the IgG. This new method delivered much higher signals as a traditional method and, hence, seems to be preferable in many applications.
Thousands of antibodies for diagnostic and other analytical purposes are on the market. However, it is often difficult to identify duplicates, reagent changes, and to assign the correct original publications to an antibody. This slows down scientific progress and might even be a cause of irreproducible research and a waste of resources. Recently, activities were started to suggest the sole use of recombinant antibodies in combination with the open communication of their sequence. In this case, such uncertainties should be eliminated. Unfortunately, this approach seems to be rather a long-term vision since the development and manufacturing of recombinant antibodies remain quite expensive in the foreseeable future. Also, nearly all commercial antibody suppliers may be reluctant to publish the sequence of their antibodies, since they fear counterfeiting. De-novo sequencing of antibodies is also not feasible today for a reagent user without access to the hybridoma clone. Nevertheless, it seems to be crucial for any scientist to have the opportunity to identify an antibody undoubtedly to guarantee the traceability of any research activity using antibodies from a third party as a tool. For this purpose, we developed a method for the identification of antibodies based on a MALDI-TOF-MS fingerprint. To circumvent lengthy denaturation, reduction, alkylation, and enzymatic digestion steps, the fragmentation was performed with a simple formic acid hydrolysis step. Eighty-nine unknown monoclonal antibodies were used for this study to examine the feasibility of this approach. Although the molecular assignment of peaks was rarely possible, antibodies could be easily recognized in a blinded test, simply from their mass-spectral fingerprint. A general protocol is given, which could be used without any optimization to generate fingerprints for a database. We want to propose that in most scientific projects relying critically on antibody reagents, such a fingerprint should be established to prove and document the identity of the used antibodies and to assign a specific reagent to a datasheet of a commercial supplier, a public database record or an antibody ID.
Thousands of antibodies for diagnostic and other analytical purposes are on the market. However, it is often difficult to identify duplicates, reagent changes, and to assign the correct original publications to an antibody. This slows down scientific progress and might even be a cause of irreproducible research and a waste of resources. Recently, activities were started to suggest the sole use of recombinant antibodies in combination with the open communication of their sequence. In this case, such uncertainties should be eliminated. Unfortunately, this approach seems to be rather a long-term vision since the development and manufacturing of recombinant antibodies remain quite expensive in the foreseeable future. Nearly all commercial antibody suppliers also may be reluctant to publish the sequence of their antibodies, since they fear counterfeiting. De novo sequencing of antibodies is also not feasible today for a reagent user without access to the hybridoma clone. Nevertheless, it seems to be crucial for any scientist to have the opportunity to identify an antibody undoubtedly to guarantee the traceability of any research activity using antibodies from a third party as a tool. For this purpose, we developed a method for the identification of antibodies based on a MALDI-TOF MS fingerprint. To circumvent lengthy denaturation, reduction, alkylation, and enzymatic digestion steps, the fragmentation was performed with a simple formic acid hydrolysis step. Eighty-nine unknown monoclonal antibodies were used for this study to examine the feasibility of this approach. Although the molecular assignment of peaks was rarely possible, antibodies could be easily recognized in a blinded test, simply from their mass-spectral fingerprint. A general protocol is given, which could be used without any optimization to generate fingerprints for a database. We want to propose that, in most scientific projects relying critically on antibody reagents, such a fingerprint should be established to prove and document the identity of the used antibodies, as well as to assign a specific reagent to a datasheet of a commercial supplier, public database record, or antibody ID.
Homochirality is an obvious feature of life on Earth. On the other hand, extraterrestrial samples contain largely racemic compounds. The same is true for any common organic synthesis. Therefore, it has been a perplexing puzzle for decades how these racemates could have formed enantiomerically enriched fractions as a basis for the origin of homochiral life forms. Numerous hypotheses have been put forward as to how preferentially homochiral molecules could have formed and accumulated on Earth. In this article, it is shown that homochirality of the abiotic organic pool at the time of formation of the first self-replicating molecules is not necessary and not even probable. It is proposed to abandon the notion of a molecular ensemble and to focus on the level of individual molecules. Although the formation of the first self-replicating, most likely homochiral molecule is a seemingly improbable event, on a closer look, it is almost inevitable that homochiral molecules have formed simply on a statistical basis. In this case, the non-selective leap to homochirality would be one of the first steps in chemical evolution directly out of a racemic “ocean”. Moreover, most studies focus on the chirality of the primordial monomers with respect to an asymmetric carbon atom. However, any polymer with a minimal size that allows folding to a secondary structure, would spontaneously lead to asymmetric higher structures (conformations). Most of the functions of these polymers would be influenced by this inherently asymmetric folding. To summarize, simple and universal mechanisms may have led to homochiral self-replicating systems in the context of chemical evolution. A homochiral monomer pool is deemed unnecessary and probably never existed on primordial Earth.
Under the auspices of the Protein Analysis Working Group (PAWG) of the Comité Consultatif pour la Quantité de Matière (CCQM) a pilot study, CCQM-P216, was coordinated by the Chinese National Institute of Metrology (NIM), National Research Council of Canada (NRC) and the Bureau International des Poids et Mesures (BIPM). Eleven Metrology Institutes or Designated Institutes and the BIPM participated in the first phase of the pilot study (Part 1). The purpose of this pilot study was to develop measurement capabilities for larger proteins using a recombinant humanized IgG monoclonal antibody against Spike glycoprotein of SARS-CoV-2 (Anti-S IgG mAb) in solution. The first phase of the study was designed to employ established methods that had been previously studies by the CCQM Protein Analysis Working Group, involving the digestion of protein down to the peptide or amino acid level. The global coronavirus pandemic has also led to increased focus on antibody quantitation methods. IgG are among the immunoglobulins produced by the immune system to provide protection against SARS-CoV-2. Anti-SARS-CoV-2 IgG can therefore be detected in samples from affected patients. Antibody tests can show whether a person has been exposed to the SARS-CoV-2, and whether or not they potentially show lasting immunity to the disease. With the constant spread of the virus and the high pressure of re-opening economies, antibody testing plays a critical role in the fight against COVID-19 by helping healthcare professionals to identify individuals who have developed an immune response, either via vaccination or exposure to the virus. Many countries have launched large-scale antibody testing for COVID-19. The development of measurement standards for the antibody detection of SARS-CoV-2 is critically important to deal with the challenges of the COVID-19 pandemic. In this study, the SARS-CoV-2 monoclonal antibody is being used as a model system to build capacity in methods that can be used in antibody quantification. Amino acid reference values with corresponding expanded uncertainty of 36.10 ± 1.55 mg/kg, 38.75 ± 1.45 mg/kg, 18.46 ± 0.78 mg/kg, 16.20 ± 0.67 mg/kg and 30.61 ± 1.30 mg/kg have been established for leucine, valine, phenylalanine, isoleucine and proline, respectively. Agreement between nearly all laboratories was achieved for the amino acid analysis within 2 to 2.5 %, with one participant achieving markedly higher results due to a technical issue found in their procedure; this result was thus excluded from the reference value calculations. The relatively good agreement within a laboratory between different amino acids was not dissimilar to previous results for peptides or small proteins, indicating that factors such as hydrolysis conditions and calibration procedures could be the largest sources of variability. Peptide reference values with corresponding expanded uncertainty of 4.99 ± 0.28 mg/kg and 6.83 ± 0.65 mg/kg have been established for ALPAPIEK and GPSVFPLAPSSK, respectively. Not surprisingly due to prior knowledge from previous studies on peptide quantitation, agreement between laboratories for the peptide-based analysis was slightly poorer at 3 to 5 %, with one laboratory's result excluded for the peptide GPSVFPLAPSSK. Again, this level of agreement was not significantly poorer than that achieved in previous studies with smaller or less complex proteins. To reach the main text of this paper, click on Final Report.
Antibody-gated indicator delivery (gAID) systems based on mesoporous silica nano- and microparticle scaffolds are a promising class of materials for the sensitive chemical detection of small-molecule analytes in simple test formats such as lateral flow assays (LFAs) or microfluidic chips. Their architecture is reminiscent of drug delivery systems, only that reporter molecules instead of drugs are stored in the voids of a porous host particle. In addition, the pores are closed with macromolecular “caps” through a tailored “gatekeeping” recognition chemistry so that the caps are opened when an analyte has reacted with a “gatekeeper”. The subsequent uncapping leads to a release of a large number of indicator molecules, endowing the system with signal amplification features. Particular benefits of such systems are their modularity and adaptability. With the example of the immunochemical detection of type-I pyrethroids by fluorescent dye-releasing gAID systems, the influence of several tuning modes on the optimisation of such hybrid sensory materials is introduced here. In particular, different mesoporous silica supports (from nano- and microparticles to platelets and short fibres), different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in the absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material's pore opening, the better the closing/opening mechanism can be controlled. Because such materials are well-suited for LFAs, performance assessment included a test-strip format besides conventional assays in suspension. In combination with dyes as indicators and smartphones for read-out, simple analytical tests for use by untrained personnel directly at a point-of-need such as an aeroplane cabin can be devised, allowing for sensitivities down to the μg kg−1 range in <5 min with case-required selectivities.
Vor dem Hintergrund der einzigartigen Modularität, hohen Empfindlichkeit und Selektivität von Antikörper‐gesteuerten Indikatorfreisetzungssystemen (gAID‐Systemen) wurde hier ein Multiplex‐Assay für drei organische Explosivstoffmoleküle (TATP, TNT, PETN) entwickelt, der es erlaubt, die Analyten gleichzeitig in flüssiger Phase mit einem einzelnen Teststreifen und einem Fluoreszenzlesegerät bzw. Smartphone als Detektor in Konzentrationen bis in den unteren ppb‐Bereich in <5 min nachzuweisen. Alle drei Systeme, darunter die hier neu entwickelten Systeme für TNT und PETN, tolerieren zudem nicht nur gepufferte wässrige Modelllösungen, sondern auch komplexere Matrices. Neben einem konventionellen Teststreifen mit einem Kanal erlaubte uns die Anwendung von Wachsdrucktechnologie das Herstellen von mehrkanaligen Streifen mit vergleichbarer analytischer Leistungsfähigkeit, was das enorme Potenzial der modular aufgebauten, hybriden Biosensormaterialien im Hinblick auf eine für den Endanwender maßgeschneiderte Vor‐Ort‐Analytik unterstreicht.
Amino acid analysis is considered to be the gold standard for quantitative peptide and protein analysis. Here, we would like to propose a simple HPLC/UV method based on a reversed-phase separation of the aromatic amino acids tyrosine (Tyr), phenylalanine (Phe), and optionally tryptophan (Trp) without any derivatization. The hydrolysis of the proteins and peptides was performed by an accelerated microwave technique, which needs only 30 minutes. Two internal standard compounds, homotyrosine (HTyr) and 4-fluorophenylalanine (FPhe) were used for calibration. The limit of detection (LOD) was estimated to be 0.05 µM (~10 µg/L) for tyrosine and phenylalanine at 215 nm. The LOD for a protein determination was calculated to be below 16 mg/L (~300 ng BSA absolute). Aromatic amino acid analysis (AAAA) offers excellent accuracy and a precision of about 5% relative standard deviation, including the hydrolysis step. The method was validated with certified reference materials (CRM) of amino acids and of a pure protein (bovine serum albumin, BSA). AAAA can be used for the quantification of aromatic amino acids, isolated peptides or proteins, complex peptide or protein samples, such as serum or milk powder, and peptides or proteins immobilized on solid supports.
The quality of research antibodies is an issue for decades. Although several papers have been published to improve the situation, their impact seems to be limited. This publication makes the effort to simplify the description of validation criteria in a way that the occasional antibody user is able to assess the validation level of an immunochemical reagent. A simple, 1-page checklist is supplied for the practical application of these criteria.
Phage display biopanning with Illumina next-generation sequencing (NGS) is applied to reveal insights into peptide-based adhesion domains for polypropylene (PP). One biopanning round followed by NGS selects robust PP-binding peptides that are not evident by Sanger sequencing. NGS provides a significant statistical base that enables motif analysis, statistics on positional residue depletion/enrichment, and data analysis to suppress false-positive sequences from amplification bias. The selected sequences are employed as water-based primers for PP-metal adhesion to condition PP surfaces and increase adhesive strength by 100% relative to nonprimed PP.
Screening of one-bead-one-compound (OBOC) libraries is a proven procedure for the identification of protein-binding ligands. The demand for binders with high affinity and specificity towards various targets has surged in the biomedical and pharmaceutical field in recent years. The traditional peptide screening involves tedious steps such as affinity selection, bead picking, sequencing, and characterization. Herein, we present a high-throughput “all-on-one chip” system to avoid slow and technically complex bead picking steps. On a traditional glass slide provided with an electrically conductive tape, beads of a combinatorial peptide library are aligned and immobilized by application of a precision sieve. Subsequently, the chip is incubated with a fluorophore-labeled target protein. In a fluorescence scan followed by matrix-assisted laser desorption/ionization (MALDI)-time of flight (TOF) mass spectrometry, high-affinity binders are directly and unambiguously sequenced with high accuracy without picking of the positive beads. The use of an optimized ladder sequencing approach improved the accuracy of the de-novo sequencing step to nearly 100%. The new technique was validated by employing a FLAG-based model system, identifying new peptide binders for the monoclonal M2 anti-FLAG antibody, and was finally utilized to search for IgG-binding peptides. In the present format, more than 30,000 beads can be screened on one slide.
The allergenic potential of airborne proteins may be enhanced via post-translational modification induced by air pollutants like ozone (O3) and nitrogen dioxide (NO2). The molecular mechanisms and kinetics of the chemical modifications that enhance the allergenicity of proteins, however, are still not fully understood. Here, protein tyrosine nitration and oligomerization upon simultaneous exposure of O3 and NO2 were studied in coated-wall flow-tube and bulk solution experiments under varying atmospherically relevant conditions (5–200 ppb O3, 5–200 ppb NO2, 45–96% RH), using bovine serum albumin as a model protein. Generally, more tyrosine residues were found to react via the nitration pathway than via the oligomerization pathway. Depending on reaction conditions, oligomer mass fractions and nitration degrees were in the ranges of 2.5–25% and 0.5–7%, respectively. The experimental results were well reproduced by the kinetic multilayer model of aerosol surface and bulk chemistry (KM-SUB). The extent of nitration and oligomerization strongly depends on relative humidity (RH) due to moisture-induced phase transition of proteins, highlighting the importance of cloud processing conditions for accelerated protein chemistry. Dimeric and nitrated species were major products in the liquid phase, while protein oligomerization was observed to a greater extent for the solid and semi-solid phase states of proteins. Our results show that the rate of both processes was sensitive towards ambient ozone concentration but rather insensitive towards different NO2 levels. An increase of tropospheric ozone concentrations in the Anthropocene may thus promote pro-allergic protein modifications and contribute to the observed increase of allergies over the past decades.