The lack of traceability to meter of X-ray Computed Tomography (CT) measurements still hinders a more extensive acceptance of CT in coordinate metrology and industry. To ensure traceable, reliable, and accurate measurements, the determination of the task-specific measurement uncertainty is necessary. The German guideline VDI/VDE 2630 part 2.1 describes a procedure to determine the measurement uncertainty for CT experimentally by conducting several repeated measurements with a calibrated test specimen. However, this experimental procedure is cost and effort intensive. Therefore, the simulation of dimensional measurement tasks conducted with X-ray computed tomography can close these drawbacks. Additionally, recent developments towards a resource and cost-efficient production (“smart factory”) motivate the need for a corresponding numerical model of a CT system (“digital twin”) as well. As there is no standardized procedure to determine the measurement uncertainty of a CT system by simulation at the moment, the project series CTSimU was initiated, aiming at this gap. Concretely, the goal is the development of a procedure to determine the measurement uncertainty numerically by radiographic simulation. The first project (2019-2022), "Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU" developed a framework to qualify a radiographic simulation software concerning the correct simulation of physical laws and functionalities. The most important outcome was a draft for a new guideline VDI/VDE 2630 part 2.2, which is currently under discussion in the VDI/VDE committee. The follow-up project CTSimU2 "Realistic Simulation of real CT systems with a basic-qualified Simulation Software" will deal with building and characterizing a digital replica of a specific real-world CT system. The two main targets of this project will be a toolbox including methods and procedures to configure a realistic CT system simulation and to develop tests to check if this replica is sufficient enough. The result will be a draft for a follow-up VDI/VDE guideline proposing standardized procedures to determine a CT system's corresponding characteristics and test the simulation (copy) of a real-world CT system which we call a "digital twin".
The effect of the wall thickness variation of blow-moulded bodies made of high-density polyethylene on an internal pressure test after prestoring the packaging with standard liquids was evaluated in experiments and simulations. The objects of the investigation were jerrycans used for the transportation and storage of dangerous goods.
The wall thickness was determined using two alternative methods to the magnetostatic measurement. These alternative methods are used for research purpose to get a volumetric model of the jerrycan wall as a geometric model for the simulation. The comparison of the experiments and the simulations of the internal pressure test were performed using the digital image correlation method. The integral strain and deformation of the whole jerrycan was detected by measuring the total mass of the jerrycan being filled with water during the internal pressure test. This is a suitable alternative to the optical measurements of local deformation by the digital image correlation method. Prestorage at 40°C without the influence of chemicals strengthens the jerrycan, whereas the swelling effect of butyl acetate and hydrocarbon mixture softens the jerrycan. The comparison with the experiment is necessary to verify the accuracy of the simulation. It shows that the deformation can be simulated more precisely by using the actual measured geometry. The weakening of the high-density polyethylene caused by a hydrocarbon mixture can be simulated using the Arrhenius equation. The aim of the simulation was to discover whether it is possible to use specimens to predict the behaviour of a packaging both after the influence of standard liquids.