Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (15)
- Beitrag zu einem Tagungsband (5)
- Sonstiges (5)
- Beitrag zu einem Sammelband (2)
- Vortrag (1)
Schlagworte
- Archaeometry (9)
- Cultural heritage (7)
- X-ray fluorescence analysis (4)
- Micro-XRF (3)
- Conservation (2)
- Micro-XANES (2)
- Quantification (2)
- Restoration (2)
- X-ray spectroscopy (2)
- 3D X-ray fluorescence analysis (1)
Eingeladener Vortrag
- nein (1)
Polycapillary halflenses are widely used to focus X-ray radiation onto a small spot. Additionally they can reduce the field of view of a semiconductor detector when placed in front of one. In 3D micro X-ray fluorescence spectroscopy (3D Micro-XRF) with synchrotron radiation, two polycapillary halflenses are used in a confocal geometry. Up until now, characterization measurements in the focal plane have only been performed in the case of the lens focusing parallel radiation. Assumptions have been made, that in the other case, when isotropic radiation from a spot source is transported to a detector, the acceptance distribution in the focal plane is also Gaussian. We performed measurements with an electron beam as well as a proton beam which confirm this assumption. In addition, a comparison between measurements in collecting and focusing mode show differences in spot size and transmission. These differences exemplify the fact that there is not one global spot size or transmission function of a polycapillary halflens. Illumination and divergence effects can alter both characteristic lens parameters.
A new fundamental parameter based calibration procedure for micro X-ray fluorescence spectrometers
(2011)
Fundamental parameter based quantification of X-ray fluorescence (XRF) measurement data requires an accurate knowledge of the spectrometer parameters, including the spectral distribution of the excitation radiation. In case of micro-XRF where a polycapillary optic is utilized in the excitation channel this distribution is changed due to the transmission properties of the lens. A new calibration procedure, based on fluorescence data of thin standard samples, was developed to determine the excitation spectrum, i.e., the product of the X-ray tube spectrum and the transmission of the used X-ray optic of a micro-XRF setup. The calibration result was validated by the quantitative analyses of certified multi-element reference standards and shows uncertainties in the order of 2% for main components, 10% for minor elements and 25% for trace elements. The influence of secondary order effects like Coster–Kronig transitions and cascade effects is analyzed and the accuracy of fundamental parameters in common databases is discussed.
A sealable ultrathin window sample cell for the study of liquids by means of soft X-ray spectroscopy
(2017)
A new sample cell concept for the analysis of liquids or solid-liquid interfaces using soft X-ray spectroscopy is presented, which enables the complete sealing of the cell as well as the Transport into vacuum via, for example, a load-lock system. The cell uses pressure monitoring and active as well as passive pressure regulation systems, thereby facilitating the full control over the pressure during filling, sealing, evacuation, and measurement. The cell design and sample preparation as well as the crucial sealing procedure are explained in detail. As a first proof-of-principle experiment, successful nitrogen K-edge fluorescence yield near-edge X-ray absorption fine structure experiments of a biomolecular solution are presented. For this purpose, it is shown that the careful evaluation of all involved parameters, such as window type or photon flux, is desirable for optimizing the experimental result.
Naturwissenschaftler arbeiten mit Archäologen, Kunsthistorikern und Restauratoren zusammen, um Materialinformationen über Kunstwerke mit den Erkenntnissen aus Altertumsforschung, Kunstgeschichte und Denkmalpflege zu verbinden. Röntgenfluoreszenz und Röntgenemission sind die Methoden der Wahl, wenn wertvolle und fragile Objekte zerstörungsfrei zu untersuchen sind.
3D micro X-ray fluorescence spectroscopy - combining elemental analysis with chemical speciation
(2004)
Naturwissenschaftliche Informationen, insbesondere die chemische Zusammensetzung der Objekte, können Hinweise auf die Hintergründe der Objektherstellung liefern, die der alleinigen kunsthistorischen Begutachtung verborgen blieben. Es können nicht nur Fragen nach dem Prozess, Zeitpunkt und Ort der Herstellung beantwortet werden. Die chemische Analyse gibt auch Hinweise auf Ereignisse und Veränderungen, die erst nach der Fertigstellung des Objektes erfolgten. So werden Alterungsphänomene oder historische Überarbeitungen und Restaurierungen aufgedeckt, aber auch Konservierungsstrategien zur Erhaltung der Kunstwerke unterstützt. Durch den technologischen Fortschritt im Bereich der röntgenanalytischen Methoden, die berührungsfrei, ohne Probennahme und ohne Schädigung für das Untersuchungsobjekt arbeiten, erschließen sich dem Analytiker erstmalig Möglichkeiten, auch sehr wertvolle und fragile Objekte zerstörungsfrei zu untersuchen.