To determine a polymer’s spectral response of photo degradation, two main methods have been established. The so-called “filter technique” uses polychromatic radiation, which is filtered by a set of various sharp cut-on filters. This procedure provides separated reading points of an activation spectrum of the investigated material. With the "spectrographic technique” a specimen is irradiated with pectrally dispersed radiation, locally quasi monochromatically, and the local property changes.are related to the radiant exposure at the respective wavelengths. A third method, the irradiation of specimens with quasi monochromatic radiation behind interference filters, is rarely used.
These methods have advantages and disadvantages and therefore, there are limits for conclusions from these spectral data. Concerning the quasi monochromatic Irradiation of specimens the development of new UV radiation sources looks promising.
With the rapid development of inexpensive UV Light-emitting diodes (LEDs), new : sources of nearly monochromatic radiation in the UV ränge are available, even down to about 250 nm. To determine the spectral response, the use of such UV-LEDs in TO-18 ) and TO-39 metal cases combines the advantages of low cost and energy efficiency, stable spectral irradiance, temperature.and humidity control, larger specimen areas, and an easy and stable analysis.
Combinations of different UV LEDs are also discussed as replacement for xenon arc ' radiation sources, see patent application EP01528388A1.
Eine Verkürzung der Dauer von Bewitterungsversuchen kann durch eine empfindlichere Detektion der Bewitterungseffekte erreicht werden als sie konventionell benützt wird. Eine solche besonders empfindliche Detektionsmethode stellt die Chemilumineszenz dar. Die Verkürzung durch empfindliche Detektion muss jedoch gleichzeitig der Bedingung genügen, ausreichend gute Rangkorrelation zu Bewitterungseffekten unter Anwendungsbedingungen zu zeigen. In diesem Spannungsfeld sollen die Möglichkeiten der Chemiluminiszenz-Detektion beleuchtet werden.
Accelerated weathering test for plastics and coatings that are exposed to acidic precipitation
(2009)
Due to the occurrence of acidic precipitation, and due to the fact that polymers and stabilizers may be sensititve to acids, it is important to have a laboratory test that combines weathering exposure with acidic exposure. The loss of stabilization caused by an acid damage of stabilizing system gets evident only over the weathering progress. For solid samples, for wich mostly the surface properties are relevant, the "Acid Dew and Fog Test" (ADF test) was established. For woven or tufted materials, the "Acid Rain Test" (AR test) was developed. The proposed weathering tests aim at plastics as well as at coatings.
Bei der Auswahl von Werkstoffen spielt deren Alterung oft eine untergeordnete Rolle, stattdessen wird häufig der ungealterte Ausgangszustand optimiert. Materialien altern aber unterschiedlich. Der Effekt der molekularen Alterung spiegelt sich in den Eigenschaften mehr oder weniger stark und in unterschiedlichem zeitlichen Verlauf wider. Da es kein physikalisch-chemisches Modell dafür gibt, sind Alterungseffekte empirisch zu bestimmen.
Combined impact of ultraviolet and chemical fluids on high-density polyethylene packaging material
(2012)
To investigate the ageing behaviour of filled plastic containers outdoors, square cuts of the wall of two high-density polyethylene (HDPE) types were exposed to ultraviolet (UV) radiation at their front side and to specific liquid chemicals (de-ionized water, surfactant or White Spirit) at their back. The UV radiant exposure at the front side was 80 MJ/m².
To compare the actions of the different exposures, separate dark backside fluid exposures were performed, in parallel. Besides, UV weathering was carried out until a UV radiant exposure of 325 MJ/m², being roughly comparable to outdoor exposure of one year in Northern Australia.
An unpigmented HDPE included in the investigation gave no sufficient protection for the White Spirit. In addition, it showed clear degradation after several of these exposures. In combination with the White Spirit, an increase of carbonyl bonds was measured, presumably assignable to degradation products of the White Spirit.
For a pigmented HDPE material, with the implemented combined exposures, no relevant damage was observed, within applied the exposure period.
In a laboratory test, transparent high‐density polyethylene (HDPE) jerrycans have been exposed to both UV radiation and 55 wt‐% nitric acid solution at (41 ± 2)°C, for up to 20 days. For comparison, UV radiant exposure (21 days) and nitric acid exposure (up to 6 weeks) were performed separately, at nearly equal temperatures. The damages are compared with FTIR spectroscopy in ATR and HT‐gel permeation chromatography(GPC) on a molecular level and with hydraulic internal pressure testing as a component test. For the used jerrycans, relevant oxidation can only be found after the combined exposure. This is caused by the decomposition of nitric acid into nitrous gases by UV radiation, which is also observed at lower concentrations (28 wt‐%). After 6 days of laboratory exposure, this is rated as critical, which corresponds to about 1/10 year in Central Europe, according to the UV radiant exposure. The gradual increase in oxidative damage shows the reproducibility of the test.
Die Grenzen der Oberflächentemperaturen von Proben, die der natürlichen oder einer künstlichen Globalstrahlung ausgesetzt sind, können grob mit sog. Schwarzstandard Thermometern BST oder Weißstandard Thermometern WST ermittelt werden [ 1a) ].
Um einige Mängel der aktuellen Konstruktion zu beseitigen, wird ein neues Konzept dieser Thermometer vorgeschlagen, das sie weniger träge und ihre physikalischen Eigenschaften ähnlicher denen einer 5 mm dicken Polymerplatte macht. Es wird auch gezeigt, dass eine Anforderung an die Reaktionszeit von weniger als 1 min in EN 513 unrealistisch ist.
Jerrycans made from three different types of high-density polyethylene (HDPE) were exposed outdoors, for one Berlin summer season. They were filled with a 55 percent nitric acid solution (HN03), pure water, or air, and half of them were protected from sunlight by an UV absorbing canvas. Thus, the separate effects of UV radiation and nitric acid could be compared to the combined impact. Combined impact was mainly affected by decomposition of nitric acid, resulting in presence of reactive nitrogen oxides, increased oxygen partial pressure, and UV radiation energy, simultaneously in vapour phase.
To investigate the degradation effects after the outdoor exposure, jerrycans were exposed to a so called hydraulic internal pressure test, similar to an approval test for dangerous goods packaging. After combined impact of UV radiation and nitric acid, internal pressure tests showed very fast failures, whereas after separate impacts no remarkable deteriorations were observed, compared to unaged jerrycans.
Temperature is an important parameter in weathering tests. In many (photo-)chemical degradation processes a Variation of the specimen temperature by A t = + 1 °C can cause a Variation of AP(property change) by ± 8%.
Since the early eighties it is well known that some types of black panel thermometers can show temperatures that are far below the maximum surface temperature of a black specimen. Although, there were precise requirements for the black coating of the BPT, a replacement by a white coating - depending on the design of the BPT - did not really change the temperature shown by the thermometer. There was no correlation between the BPT and the specimen surface temperature.
In Europe and later at ISO the so-called black- and white-standard thermometers BST/WST were introduced. Now, there are BST and WST (ISO) and there are thermally uninsulated and insulated BPT and WPT (ASTM), partly for artificial or for outdoor exposure. And there are other adventurous procedures to determine surface temperatures.
The different types of thermometers and different procedures will be discussed and it will be shown that there is no procedure which establishes a correlation between outdoor surface temperatures and surface temperatures in artificial exposure tests.
The aim of the joint project ViPQuali (Virtual Product Qualification) was to describe a components ageing behaviour in a given environment, by numerical simulation.
Having chosen polypropylene (PP) as the material, which does not show sensitivity to moisture, the relevant weathering parameters of the doseresponse functions could be limited to spectral irradiance and temperature.
In artificial irradiation tests, for PP plates of varied stabiliser content, spectral sensitivity as well as temperature dependence of irradiation-caused crack formation was quantified. For that purpose, samples were exposed both to artificial weathering tests at various constant temperatures and to spectrally resolved irradiation. The temperature dependence could be modelled by an Arrhenius fit. For fitting the spectral sensitivity, a plateau function was chosen. Subsequently, the stabiliser content was parameterised and extrapolated.
The formed dose–response functions were incorporated into a Computational Fluid Dynamics (CFD) software program, simulating the environment of a sample within a Phoenix-exposed IP/DP (Instrument Panel/Door Panel box) box, based on sun position and weather conditions, including radiation interactions. Observed local effects as well as the general ageing advance of PP hats are compared with respect to simulation and experiment.
Resulting from this project, for this most simple example of PP of varied stabiliser content, the time to failure can be estimated for each weathering exposure environment with known time-resolved irradiance and temperature conditions.
Accelerated weathering test for plastics and coatings that are exposed to acidic precipitation
(2008)
Chemiluminescence for the early detection of weathering effects of coatings - Part I: Fundamentals
(2010)
For polypropylene of varied stabilization, spectral sensitivity as well as temperature dependence of irradiation caused crack formation was determined in artificial irradiation tests. UV radiant exposure HUV necessary to generate crack formation was measured both in spectrally dispersed irradiation and artificial irradiation in a Fluorescent UV lamp device. Dependencies were fitted to a plateau function and an Arrhenius function, respectively, to describe the action of irradiation by response functions. Applied to weather data from Phoenix, the results were compared with respective outdoor exposure results.
Für Polypropylen unterschiedlicher Stabilisierung wurden in künstlichen Bestrahlungstests sowohl die spektrale Empfindlichkeit als auch die Temperaturabhängigkeit der Rissbildung quantitativ ermittelt. Dafür wurde die Dauer bis zur Rissbildung sowohl bei spektraler Bestrahlung als auch bei Bestrahlung in einem UV-Leuchtstofflampengerät bei verschiedenen Temperaturen bestimmt.
Die Temperaturabhängigkeit konnte als Arrhenius-Abhängigkeit beschrieben werden; das Wirkungsspektrum wurde an eine Stufenfunktion angepasst. Anschließend wurde auch noch der Einfluss des Stabilisatorgehalts als Potenzfit parametrisiert. Die Einzelabhängigkeiten wurden zu einer Gesamtfunktion der Wirkungen in Abhängigkeit der Dosis zusammengesetzt, die es ermöglicht die Wirkungen unterschiedlicher Dosiskombinationen abzuschätzen.
Zur Validierung der Dosis-Wirkungsfunktionen wurden Freibewitterungsergebnisse aus Phoenix/Arizona herangezogen. Mit der Dosis, die sich aus den Wetterdaten dieser Freibewitterung ergibt, wurden anhand der Dosis-Wirkungs-Funktionen die jeweiligen Lebensdauern errechnet und mit dem experimentell bestimmten Versagen in der Freibewitterung verglichen.
Die Arbeiten erfolgten im Rahmen des ViPQuali-Projektes mit dem Ziel der Bestimmung der Materialkenngrößen.
Ingenieurbauwerke wie Brücken, hoch beanspruchte Verkehrsflächen oder auch Hochhäuser und deren Bauwerksteile wie z.B. Hochhausfassaden werden aus technischen und ästhetischen Gründen durch Fugen in Einzelabschnitte unterteilt. Zur Sicherstellung der Gebrauchsfähigkeit und zum Schutz des Gesamtbauwerks, aber in zunehmendem Maße auch zur statisch-konstruktiven Anbindung der Bauwerksteile, werden diese Fugenspalte in aller Regel durch spezielle Fugenfüllsysteme verschlossen. Aufgrund der hohen Sicherheitsrelevanz bei Fugenfüllungen im Glasfassadenbau fordert das Baurecht auch bei diesen Bauprodukten als Voraussetzung für die baupraktische Verwendbarkeit neben dem Nachweis der Funktionsfähigkeit auch den Nachweis der Dauerhaftigkeit. Da die hierfür bekannten Nachweismethoden zur Dauerhaftigkeit keine allgemeine Zulassungsakzeptanz finden, kann das ästhetische, bauphysikalische und ökonomische Potential von modernen geklebten Ganzglasfassaden (sogenannte SSG-Fassaden) in der Baupraxis der Bundesrepublik Deutschland derzeit nicht ausgenutzt werden. Grund dafür sind die ungenügend erfassten und in den Bewertungsverfahren simulierten Wechselwirkungen derartiger Baukonstruktionen mit der Umwelt. In diesem Beitrag soll am Beispiel moderner Fugen im Glasfassadenbau (SSG-Fassaden) eine ganzheitliche gebrauchsbezogene Versuchsmethodik zur kontrollierten Ansprache der Funktionsfähigkeit und Dauerhaftigkeit von Fugensystemen unter realitätsnah und reproduzierbar simulierten Umwelteinwirkungen vorgestellt werden. Dazu werden die maßgebenden Umwelteinflüsse und die Quantifizierung der daraus folgenden Beanspruchungen auf derartige Fugensysteme dargestellt. Basierend darauf werden eine repräsentative Beanspruchungsfunktion zur Nachstellung der maßgebenden Umwelteinflüsse und Beanspruchungen auf das System Tragrahmen - Fugenfüllung- Glasscheibe sowie eine geeignete Probendimensionierung abgeleitet. In der Konsequenz werden die Erkenntnisse in den Aufbau einer neuartigen komplexen Versuchseinrichtung überführt. Funktionsprinzip und Leistungsparameter dieser Anlage zur Umweltsimulation werden vorgestellt. Die Möglichkeiten der Systemkennzeichnung werden vorgestellt. Erste Versuchsergebnisse zeigen das Potential der neuartigen Bewertungsmethodik auf, die Kunst der Fuge im Bauwesen gebrauchsorientiert weiter zu entwickeln.
The surface temperature of test specimens exposed to natural and artificial solar radiation are roughly ascertained with black standard thermometers BST and white standard thermometers WST. For the calibration of these thermometers a new European Standard prEN 16465 was published in 2015, describing the well-known contact method and a new contactless method with a pyrometer. It can be confirmed that the temperature calibrations according to the two methods provide different calibration results which are not interchangeable (which is already stated in the scope of this standard). The described contactless method to determine the surface temperature 'under radiation load' results in clearly too high temperatures. This paper tries to highlighting the reasons.
A new irradiation device for the exposure of plastic products is presented. Developed in the BAM division 3.1 "Dangerous Goods Packaging" it can be used for artificial UV irradiation of plastic Containers filled with hazardous liquids.
Present regulations and tests only investigate the exposure effects of UV and of media separately, but as the damaging effect is expected to be synergistic for at least some media, a combined test was looked for.
A chamber of 60 cm by 60 cm base area and 1 m height gives space for up to 40 cm wide objects. Two fluorescent UV lamp arrays are arranged on opposite walls, separated from the chamber by quartz glass panes. By continuously rotating the exposure object by means of a rotary disc that the object is placed on, spatial irradiation homogeneity is achieved over the exposure duration. The spectral irradiance of the chosen UVA 340 nm lamps gives the best match of global solar radiation in the short wavelength ränge. The close arrangement of the UVA lamps (15 each side) results in 60 W m'2 UV irradiance.
Constant temperature is adjusted to typically 40 °C by the control of the fan speed. This temperature is chosen, as it is the required temperature for three week storage of filled polyethylene Containers, for proving Chemical compatibility in the field of dangerous goods. To ensure homogeneity, an interiorfan provides for air circulation.