Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (49) (entfernen)
Schlagworte
- Weathering (9)
- Bewitterung (8)
- Additive Fertigung (4)
- Artificial weathering (4)
- Künstliche Bewitterung (4)
- UV (4)
- Bestrahlung (3)
- Irradiation (3)
- Spectral sensitivity (3)
- Thermografie (3)
- 3D Druck (2)
- ADF (2)
- Additive manufacturing (2)
- Alterung (2)
- Automobillacke (2)
- Automotive coatings (2)
- Kunststoffe (2)
- Polymer 3R (2)
- Polymere (2)
- Umweltsimulation (2)
- Acid Dew and Fog (1)
- Acid dew and fog test (1)
- Acid rain (1)
- Action spectrum (1)
- Active thermography (1)
- Artificial turf (1)
- Artificial weathering test (1)
- Batch test (1)
- CNT (1)
- Chemiluminescence (1)
- Chemilumineszenz (1)
- Coating (1)
- Column test (1)
- Damage (1)
- Dauerhaftigkeit (1)
- Feuchte (1)
- Flammschutz, Witterungsbeständigkeit, Langzeitbeständigkeit, UV, E&E (1)
- Fluorescent polymer optical fibres (1)
- Fungi (1)
- Funktionsverhalten (1)
- High voltage cable accessories (1)
- High-density polyethylene HDPE (1)
- Humidity (1)
- IR-Thermometer (1)
- Klima (1)
- LDPE (1)
- Leaching behaviour (1)
- Lebensdauer (1)
- Life time estimation (1)
- Low-temperature (1)
- Mildew (1)
- Mould (1)
- Nanokomposit (1)
- Nanopartikel (1)
- Natural weathering (1)
- Neue Untersuchungsmethodik (1)
- Nitric acid HNO3 (1)
- Nässe (1)
- Oberflächentemperatur (1)
- Outdoor exposure (1)
- Partial discharge detection (1)
- Photo-oxidation (1)
- Photodegradation (1)
- Pinholes (1)
- Polyamide (1)
- Polycarbonate (1)
- Polyethylene (1)
- Polypropylen (1)
- Polypropylene (1)
- Polyurethan (1)
- Prüfgeräte (1)
- Prüfverfahren (1)
- Self-healing (1)
- Service life prediction (1)
- Silicone rubber (1)
- Simulation (1)
- Simulierte Sonnenstrahlung (1)
- Spektrale Bestrahlung (1)
- Strahlungserwärmung (1)
- TPU (1)
- Temperature (1)
- Temperature dependency (1)
- Test Tailoring (1)
- Thermoluminescence (1)
- Thermolumineszenz (1)
- UV irradiation (1)
- UV radiation (1)
- UV resistance (1)
- UV weathering (1)
- UV-Bestrahlung (1)
- UV-Bestrahlungsstärke (1)
- UV-LEDs (1)
- UV-irradiance (1)
- Vorgeschichte (1)
- Waste rubber (1)
- Weathering parameters (1)
- Witterung (1)
- Zerstörungsfreie Prüfung (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (13)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (13)
- 3 Gefahrgutumschließungen; Energiespeicher (7)
- 3.1 Sicherheit von Gefahrgutverpackungen und Batterien (7)
- 8 Zerstörungsfreie Prüfung (5)
- 8.0 Abteilungsleitung und andere (5)
- 8.4 Akustische und elektromagnetische Verfahren (1)
Häufig ist es wünschenswert, für neue Materialien oder Anwendungen künstliche Bewitterungsverfahren zu benutzen, die auf die spezifischen Anforderungen besser zugeschnitten sind, als es bei bestehenden standardisierten Verfahren der Fall ist. Nachdem man die spezifischen Parameter der Beanspruchung unter Anwendungsbedingungen und die spezifische Empfindlichkeit des Materials erfasst hat, beginnt ein Prozess, der als „Test Tailoring“ häufig abstrakt verwendet, auf den aber nur selten näher eingegangen wird. Genau dieser Prozess soll hier am Beispiel der Entwicklung eines künstlichen Bewitterungstests unter saurer Beaufschlagung, dem in der BAM entwickelten Acid Dew and Fog Test, beispielhaft erläutert werden.
Mit additiven Fertigungsverfahren hergestellte Bauteile und Produkte aus Kunststoffen werden zunehmend nicht mehr nur als Prototypen, sondern als voll funktionsfähige Bauteile und Produkte gefertigt. Bedingt durch die Fertigungsprozesse und den schichtweisen Aufbau resultieren physikalische Materialeigenschaften, die stark von den Fertigungsparametern abhängen und zudem anisotrop sind. Von den Fertigungsparametern werden auch die Oberflächeneigenschaften beeinflusst, sodass zu erwarten ist, dass sich die Beständigkeit gegenüber äußeren Umwelteinflüssen bei additiv gefertigten Bauteilen von der konventionell gefertigter unterscheiden kann. Nachfolgend wird daher die Entwicklung eines Qualitätssicherungskonzeptes basierend auf spektroskopischen und zerstörungsfreien Prüfverfahren vorgestellt, in dem der Alterungsprozess von mittels Fused Deposition Modelling (FDM) und mittels Lasersintering (LS) hergestellten Probekörpern untersucht wird.
Das vorgestellte Projekt beschäftigt sich mit den optischen, thermophysikalischen und mechanischen Materialeigenschaften von additiv gefertigten Kunststoffteilen und deren Alterung. Dazu wurden mittels Fused Layer Modeling (FLM) Probekörper aus ABS hergestellt, die anschließend für drei Monate einer künstlichen Bewitterung unterzogen wurden. Die dabei erzeugte definierte Alterung wurde nach drei Zeitabschnitten jeweils mit zerstörungsfreien Methoden charakterisiert. Dabei wurde neben den spektroskopischen Standardmethoden auch die aktive Thermografie eingesetzt. Die Ergebnisse zeigen, dass sich mittels der Thermografie sowohl chemische Veränderungen als auch mechanische Schädigungen (Fehlstellen) darstellen lassen. Die Bewitterung beeinflusst die Teiltransparenz der Proben zumindest im sichtbaren Spektralbereich, was bei der Charakterisierung der Fehlstellen, die mittels optisch angeregter aktiver Thermografie detektiert wurden, berücksichtigt werden muss.
Durch das Füllen von Polymeren mit Nanopartikeln oder Nanoröhren werden verbesserte Materialeigenschaften z.B. bezüglich mechanischer Stabilität, Witterungsbeständigkeit, elektrischer Leitfähigkeit und Flammschutz angestrebt. Mit dem vermehrten Einsatz derartiger Nanokomposite gewinnen aber auch Fragen des Umwelt- und Gesundheitsschutzes an Bedeutung. Es gilt zu klären, ob durch Herstellung, Benutzung und Witterungsbeanspruchung möglichweise nanoskalige Partikel freigesetzt werden können. Zu diesem Zweck wurden mit Kohlenstoffnanoröhren, Carbon Nanotubes (CNT), gefüllte Polymerkomposite spektral breitbandig wie auch quasimonochromatisch unter variierter klimatischer Beanspruchung bestrahlt. Die sich vor allem an der Oberfläche mit der Alterung abzeichnenden Veränderungen wurden mikroskopisch und spektroskopisch charakterisiert.
To determine a polymer’s spectral response of photo degradation, two main methods have been established. The so-called “filter technique” uses polychromatic radiation, which is filtered by a set of various sharp cut-on filters. This procedure provides separated reading points of an activation spectrum of the investigated material. With the "spectrographic technique” a specimen is irradiated with pectrally dispersed radiation, locally quasi monochromatically, and the local property changes.are related to the radiant exposure at the respective wavelengths. A third method, the irradiation of specimens with quasi monochromatic radiation behind interference filters, is rarely used.
These methods have advantages and disadvantages and therefore, there are limits for conclusions from these spectral data. Concerning the quasi monochromatic Irradiation of specimens the development of new UV radiation sources looks promising.
With the rapid development of inexpensive UV Light-emitting diodes (LEDs), new : sources of nearly monochromatic radiation in the UV ränge are available, even down to about 250 nm. To determine the spectral response, the use of such UV-LEDs in TO-18 ) and TO-39 metal cases combines the advantages of low cost and energy efficiency, stable spectral irradiance, temperature.and humidity control, larger specimen areas, and an easy and stable analysis.
Combinations of different UV LEDs are also discussed as replacement for xenon arc ' radiation sources, see patent application EP01528388A1.
In den letzten Jahrzehnten wurde die Degradation der polymeren Matrix von flammgeschützten Polymeren eingehend untersucht. Erst in den letzten Jahren jedoch hat sich die Frage der Lebensdauer der Funktionalität des Flammschutzes selbst als wichtige Fragestellung herauskristallisiert, z.B. bei Kabeln. Deshalb sollte diese Fragestellung durch systematisch-variierte künstliche Klima- und Bewitterungstests an flammgeschützten Polymerwerkstoffen untersucht werden.
Additiv gefertigte Prüfkörper aus Polyamid 12 (Laser Sinter Verfahren) und Acrylnitril-Butadien-Styrol (Fused Layer Modeling Verfahren) wurden über 2000 Stunden künstlich bewittert und ihr Alterungsverhalten untersucht. Die Ergebnisse wurden anschließend mit denen von Prüfkörpern verglichen, welche auf dieselbe Weise künstlich bewittert, aber mittels konventionellem KunststoffSpritzguss hergestellt wurden.
Temperature is an important parameter in weathering tests. In many (photo-)chemical degradation processes a Variation of the specimen temperature by A t = + 1 °C can cause a Variation of AP(property change) by ± 8%.
Since the early eighties it is well known that some types of black panel thermometers can show temperatures that are far below the maximum surface temperature of a black specimen. Although, there were precise requirements for the black coating of the BPT, a replacement by a white coating - depending on the design of the BPT - did not really change the temperature shown by the thermometer. There was no correlation between the BPT and the specimen surface temperature.
In Europe and later at ISO the so-called black- and white-standard thermometers BST/WST were introduced. Now, there are BST and WST (ISO) and there are thermally uninsulated and insulated BPT and WPT (ASTM), partly for artificial or for outdoor exposure. And there are other adventurous procedures to determine surface temperatures.
The different types of thermometers and different procedures will be discussed and it will be shown that there is no procedure which establishes a correlation between outdoor surface temperatures and surface temperatures in artificial exposure tests.
To avoid a catastrophic failure of insulation in high-voltage (HV) applications, a monitoring of partial discharges (PDs) is necessary. Fluorescently labelled polymer optical fibers (F-POF) offer an electrically passive method for PD detection in HV facilities. F-POFs could be embedded in HV cable accessories, which are usually made of silicone rubber. Herein they detect the light emitted by the PD and convert it into an electrical signal that can be monitored. Due to the difficult accessibility of HV cable accessories, a self-healing silicone rubber with prolonged service life after PD detection represents an attractive material design for HV accessories. With this contribution, we would like to present and discuss the possibilities of combining self-healing materials with POF-based sensors for PD detection in HV applications.
Quantitative Auswertemöglichkeiten bei der spektralen Bestrahlung – Berechnung des Wirkungsspektrums
(2017)
Für die Bewertung des Wellenlängeneinflusses auf die Alterungsvorgänge bei der Bestrahlung UV- oder lichtempfindlicher Materialien kann die Methode der spektralen Bestrahlung angewendet werden. Im Prinzip wird dabei das linear dispergierte Spektrum einer Strahlenquelle mit kontinuierlichem Spektrum (z.B. Xe-Lampe) auf eine Probenoberfläche abgebildet, so dass Ort einer Materialänderung und Wellenlänge der Bestrahlung einander zugeordnet werden können. Nachfolgende lokal-auflösende Analysemethoden ermitteln eine Eigenschaftsänderung an einem spezifischen Ort der Probe, aus dem sich dann die Bestrahlungswellenlänge ergibt.
Der verwendete Aufbau wird beschrieben. Es wird an einem ausgewählten Beispiel gezeigt, wie durch geeignete Anbindung eines Messsystems zur Bestimmung der spektralen Bestrahlungsstärke und ortsaufgelöste Messungen der Eigenschaftsänderungen eine quantitative Auswertung realisiert werden kann. Der Einfluss nichtlinearer Alterungsverläufe wird diskutiert. Grenzen der Methode werden aufgezeigt und Erweiterungsmöglichkeiten dargestellt.
Quantitative Auswertemöglichkeiten bei der spektralen Bestrahlung – Berechnung des Wirkungsspektrums
(2017)
Für die Bewertung des Wellenlängeneinflusses auf die Alterungsvorgänge bei der Bestrahlung UV- oder lichtempfindlicher Materialien kann die Methode der spektralen Bestrahlung angewendet werden. Im Prinzip wird dabei das linear dispergierte Spektrum einer Strahlenquelle mit kontinuierlichem Spektrum (z.B. Xe-Lampe) auf eine Probenoberfläche abgebildet, so dass Ort einer Materialänderung und Wellenlänge der Bestrahlung einander zugeordnet werden können. Nachfolgende lokal-auflösende Analysemethoden ermitteln eine Eigenschaftsänderung an einem spezifischen Ort der Probe, aus dem sich dann die Bestrahlungswellenlänge ergibt.
Der verwendete Aufbau wird beschrieben. Es wird an einem ausgewählten Beispiel gezeigt, wie durch geeignete Anbindung eines Messsystems zur Bestimmung der spektralen Bestrahlungsstärke und ortsaufgelöste Messungen der Eigenschaftsänderungen eine quantitative Auswertung realisiert werden kann. Der Einfluss nichtlinearer Alterungsverläufe wird diskutiert. Grenzen der Methode werden aufgezeigt und Erweiterungsmöglichkeiten dargestellt.
Polarized fluorescence and orientational order parameters of a liquid crystalline conjugated polymer
(1999)
Jerrycans made from three different types of high-density polyethylene (HDPE) were exposed outdoors, for one Berlin summer season. They were filled with a 55 percent nitric acid solution (HN03), pure water, or air, and half of them were protected from sunlight by an UV absorbing canvas. Thus, the separate effects of UV radiation and nitric acid could be compared to the combined impact. Combined impact was mainly affected by decomposition of nitric acid, resulting in presence of reactive nitrogen oxides, increased oxygen partial pressure, and UV radiation energy, simultaneously in vapour phase.
To investigate the degradation effects after the outdoor exposure, jerrycans were exposed to a so called hydraulic internal pressure test, similar to an approval test for dangerous goods packaging. After combined impact of UV radiation and nitric acid, internal pressure tests showed very fast failures, whereas after separate impacts no remarkable deteriorations were observed, compared to unaged jerrycans.
The surface temperature of test specimens exposed to natural and artificial solar radiation are roughly ascertained with black standard thermometers BST and white standard thermometers WST. For the calibration of these thermometers a new European Standard prEN 16465 was published in 2015, describing the well-known contact method and a new contactless method with a pyrometer. It can be confirmed that the temperature calibrations according to the two methods provide different calibration results which are not interchangeable (which is already stated in the scope of this standard). The described contactless method to determine the surface temperature 'under radiation load' results in clearly too high temperatures. This paper tries to highlighting the reasons.
Aufgrund des tieferen Eindringens der solaren Strahlung treten bei transparenten und bei transluzenten (durchscheinenden) Kunststoffen veränderte Bedingungen gegenüber opaken Proben auf. Dies kann zu speziellen Effekten und damit zu einem abweichenden Bewitterungsverhalten führen. Auch aus Mangel an geeigneten Normen werden diese Effekte häufig vernachlässigt. Deshalb initiiert der DIN-FNK auf ISO-Ebene ein entsprechendes Dokument.
Die Norm ist in der Form eines Technical Reports geplant. In einem ersten Teil sollen die Besonderheiten transparenter oder transluzenter Kunststoffe erläutert werden, um den Nutzer für mögliche Probleme zu sensibilisieren. Im zweiten Teil werden Empfehlungen für Bestrahlung oder Bewitterung herausgearbeitet. In einem dritten Teil geht es dann um Besonderheiten bei der Messung von Eigenschaftsänderungen transparenter bzw. transluzenter Kunststoffe. In informativen Anhängen sollen verschiedene Beispiele die Thematik illustrieren.
Photo-oxidative ageing of polymers under defined exposure (UV, humidity) was investigated from two points of view: a) the ageing process Starts from the topmost surface and penetrates slowly towards bulk and b) radicals play an important role among ageing. Therefore, X-ray photoelectron (XPS) and electron spin resonance (ESR) spectroscopy were applied to show both, the progressive incorporation of oxygen during in-situ UV irradiation (XPS) and the formation of radicals (ESR) in the polymer. The intensity of ESR Signals served as measure for radical concentration. The Validation of this correlation was checked for polyethylenes (PE) equipped with different concentrations of Hostavin N30 UV stabilizer.