Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (18) (entfernen)
Schlagworte
- Strain sensor (7)
- Validation (7)
- Reliability (6)
- Durability (4)
- Fibre-optic sensor (3)
- Sensor characteristics (3)
- Structural health monitoring (3)
- Adhesive stability (2)
- Application (2)
- Application-related changes (2)
Organisationseinheit der BAM
Strain sensors embedded in or attached to structural components have to measure the real deformation of the structure over the whole period of use. The user must know how reliably installed sensors provide strain measurement results. For this purpose, test facilities or coupon tests are used. In order to characterize the strain transfer quality from the host structure into surface-applied strain sensors, a unique testing facility has been developed. This facility can be used both for fiber optic and resistance strain sensors. Originally developed for fiber Bragg grating based sensors, the KALFOS facility (=calibration of fiber optic sensors) uses Digital Image Correlation (DIC) and Electronic Speckle Pattern Interferometer (ESPI) as unbiased referencing methods. It is possible to determine experimentally the strain transfer mechanism under combined thermal and mechanical loading conditions. This experimental characterization method will reveal weaknesses in commonly used strain sensors, and the investigation of the material systems used for fiber optic and other strain sensors (particularly the coating/substrate - adhesive combination). The KALFOS facility allows matching of specific measurement requirements with environmental conditions.
A high-performance fiber Bragg grating-based (FBG) sensor device has been developed for the detection of small magnetic fields. Based on a smart multilayer jacket around the fibre over the physical length of the FBG, magnetic fields generated by rotating machine parts, power generators or power cable can be easily detected, analysed and evaluated. Consequently, this innovative, on-line and non-contact inspection method results in an increase in quality and reliability of high-performing machine parts, devices and cables. The basic physical principle is based on a magnetostrictive multilayer system that strains the high-resolution FBG element in presence of magnetic fields. Subsequently, a fixed relationship between induced magnetic field and wavelength change of the FBG element describes the characteristic sensitivity curve. Intensive tests regarding characterisation of this magnetic field FBG sensor have been carried out and its performance has been evaluated.
A new concept for the self-diagnosis of embedded fiber Bragg grating (FBG) strain sensors was developed, simulated and experimentally tested. This concept is based on a magnetostrictive metallic layer directly coated on the fibre cladding over the grating segment of the FBG sensor, so that an on-demand external magnetic field in a millitesla scale can produce a controllable artificial strain as an indication signal for the remote optical interrogator. The relationship between the pre-defined magnetic field and its induced Bragg wavelength shift characterizes this validation concept. Any deviation of the local bonding state of the interfaces from the initial or/and any change of shear strain transferring mechanism from composite matrix to the optical fibre core will result in alterations in this sensitive relationship, and thus triggers an immediate alert for a further inspection. The finite element method is used to simulate the strain of this configuration as result of different values of the magnetic field in order to optimize the geometrical sensor parameters. The simulations are verified by experiments results. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Fibre-optic sensors need to be more established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations. However, there are some open questions leading now and then to restraints in the user's community. The paper dicusses examples where fibre-optic sensors provide outstanding knowledge about the structure's behaviour, but application is often challenging. Requirements are listed and open questions to be solved are discussed. Short outlook to standards useful for better design, characterization and application is given. Standards are the basis for establiching SHM systems, especially for safety-critical structural diagnostics.
Fiber-optic strain sensors are increasingly used in very different technical fields. Sensors are provided with specifications defined by the manufacturer or ascertained by the interested user. In some cases, sensor specification is not sufficiently validated and must therefore additionally be validated in a laboratory, primarily to ensure reliable measurement information over the intended period of operation. Even if the performance of delivered sensor is well specified, the sensor's strain characteristics and the performance of an applied sensor can significantly differ from the virgin sensor's performance. In this case, applied sensors do not provide full reliability and lead sometimes to uncertain measurement results. This contribution will therefore focus on the role of validation in avoiding a decrease or even deterioration of the sensor function of applied sensors. Experimental validation - not only modelling - is very important, however, before experimental investigations are planned knowledge about key issues and problems that influence the measurement results must be available. Few aspects to be considered and investigated will be discussed. Selected experimental facilities to reveal weaknesses in the sensor function will be described; an outlook to open questions is given.
Fiber optic strain sensors are increasingly used and sensor Systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor’s the performance. Therefore the contribution considers validation issues to come to reliable strain measurements and how to validate strain measurements of applied sensors. A new validation facility will be presented.