Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (18)
- Zeitschriftenartikel (9)
- Vortrag (6)
- Posterpräsentation (5)
- Beitrag zu einem Sammelband (2)
- Forschungsbericht (1)
Schlagworte
- Validation (11)
- Reliability (8)
- Strain sensor (7)
- Fiber Bragg grating (5)
- Strain transfer (5)
- Durability (4)
- Fibre Bragg grating (4)
- Fibre optic sensors (4)
- Fibre-optic sensor (4)
- Magnetic field (4)
- Patch (4)
- Strain (4)
- Application (3)
- Fiber bragg grating (3)
- Magnetostrictive metal coating (3)
- Self-diagnostic fiber optical sensor (3)
- Sensor characteristics (3)
- Structural health monitoring (3)
- Adhesive stability (2)
- Application-related changes (2)
- Electronic speckle pattern interferometry (2)
- Fiber Bragg gratings (2)
- Guideline (2)
- Magnetostriction (2)
- Magnetostriktive Beschichtung (2)
- Monitoring (2)
- Qualification (2)
- Standards (2)
- Strain gauge (2)
- Strain gauge factor (2)
- Surface application (2)
- Surface application reliability (2)
- 3D-image correlation (1)
- Actuators (1)
- Adhesive (1)
- Auto-validation (1)
- Bauteilmonitoring (1)
- Calibration (1)
- Composite materials (1)
- Condition diagnostics (1)
- Creep (1)
- Digital image correlation (1)
- ECD-Aktorschicht (1)
- Early damage detection (1)
- Embedded sensors (1)
- Evaluation (1)
- Faser-Bragg Gitter (1)
- Faser-Bragg-Gitter (FBG) (1)
- Faseroptik-Sensoren (1)
- Fatigue behavior (1)
- Fatigue behaviour (1)
- Fiber optic sensors (1)
- Fiber optics (1)
- Fiber-optic sensor (1)
- Finite element methods (1)
- Four-parametric (1)
- Harsh impacts (1)
- Laser extensometer (1)
- Long-term stability (1)
- Magneto-optischer Sensor (1)
- Maintenance (1)
- Materials behaviour (1)
- Modeling and simulation (1)
- Nickel-/Nickel-Eisen- Magnetostriktion (1)
- Offshore application (1)
- PVD-Haftfestigkeit (1)
- Push-out test (1)
- Rayleigh backscattering (1)
- Repair (1)
- Rosette (1)
- Selbstkalibrierung (1)
- Self-diagnosis (1)
- Sensors (1)
- Sensorvalidierung (1)
- Speckle-interferometry (1)
- Strain measurement (1)
- Structural Health Monitoring (SHM) (1)
- Superstructure (1)
- Temperature (1)
- Temperature sensitivity (1)
- Testing (1)
- Validation facility (1)
- model (1)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (6)
Fiber optic strain sensors are increasingly used and sensor Systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor’s the performance. Therefore the contribution considers validation issues to come to reliable strain measurements and how to validate strain measurements of applied sensors. A new validation facility will be presented.
Surface-applied fibre optic strain sensors were investigated using a unique validation facility equipped with application-independent optical reference systems. First, different adhesives for the sensor's application were analysed regarding their material properties. Measurements resulting from conventional measurement techniques, such as thermo-mechanical analysis and dynamic mechanical analysis, were compared with measurements resulting from digital image correlation, which has the advantage of being a non-contact technique. Second, fibre optic strain sensors were applied to test specimens with the selected adhesives. Their strain-transfer mechanism was analysed in comparison with conventional strain gauges. Relative movements between the applied sensor and the test specimen were visualized easily using optical reference methods, digital image correlation and electronic speckle pattern interferometry. Conventional strain gauges showed limited opportunities for an objective strain-transfer analysis because they are also affected by application conditions.
This work presents a further development of the methods of simultaneous determination of temperature and axial strain using a single fibre Bragg grating (FBG). The reflected spectrum of composite-embedded FBG sensors has been analyzed in order to separate temperature and load effects. We found out that during the curing process of the laminates, a superstructure has been introduced on the FBG. Analyzing this effect, a temperature and strain separation was implemented by simply calculating and comparing the integrated intensity of the spectral response signal. A mathematical four-parametric model has been developed to calculate the reflected spectrum of a superstructured fibre Bragg grating. The mathematically achieved data has been evaluated with experimentally determined data from fibre Bragg gratings embedded in glass-fibre reinforced composite materials.
Fiber-optic strain sensors are increasingly used in very different technical fields. Sensors are provided with specifications defined by the manufacturer or ascertained by the interested user. In some cases, sensor specification is not sufficiently validated and must therefore additionally be validated in a laboratory, primarily to ensure reliable measurement information over the intended period of operation. Even if the performance of delivered sensor is well specified, the sensor's strain characteristics and the performance of an applied sensor can significantly differ from the virgin sensor's performance. In this case, applied sensors do not provide full reliability and lead sometimes to uncertain measurement results. This contribution will therefore focus on the role of validation in avoiding a decrease or even deterioration of the sensor function of applied sensors. Experimental validation - not only modelling - is very important, however, before experimental investigations are planned knowledge about key issues and problems that influence the measurement results must be available. Few aspects to be considered and investigated will be discussed. Selected experimental facilities to reveal weaknesses in the sensor function will be described; an outlook to open questions is given.
Fibre-optic sensors need to be more established in the sensor market. Their advantages have unquestionably been verified by numerous demonstrations. However, there are some open questions leading now and then to restraints in the user's community. The paper dicusses examples where fibre-optic sensors provide outstanding knowledge about the structure's behaviour, but application is often challenging. Requirements are listed and open questions to be solved are discussed. Short outlook to standards useful for better design, characterization and application is given. Standards are the basis for establiching SHM systems, especially for safety-critical structural diagnostics.
Reliable measurement results with fibre optic sensors require profound knowledge of physical mode of function, of materials used and appropriate application. There is often serious discrepancy between use in laboratory environment and on site. The paper identifies important aspects to be considered and shows ways to transfer innovations onto practical use.
Reliability analysis of fibre optic sensors for monitoring of industrial facilities; keynote lecture
(2013)
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT. In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
Fiber optic sensors have gained increasing importance in recent years and are well established in many areas of industrial applications. In this paper, we introduce a concept of a self-diagnostic fiber optic sensor. The presented sensor is to resolve the problems of embedded fiber optic sensors in complex structures and to enable the validation under operational conditions. For this purpose, different magnetostrictive coated fiber optic sensors were developed and various experiments were performed to verify their mode of Operation and to determine the respective reproducibility. The measuring principle is illustrated by obtained experimental results, which showed a change in wavelength from 1 pm at a magnetic field strength change of 0.25 mT.
In addition, the temperature characteristics of the implemented magnetostrictive sensor were analyzed and an experimental factor of 1.5 compared to a reference fiber optic sensor was determined.
A new concept for the self-diagnosis of embedded fiber Bragg grating (FBG) strain sensors was developed, simulated and experimentally tested. This concept is based on a magnetostrictive metallic layer directly coated on the fibre cladding over the grating segment of the FBG sensor, so that an on-demand external magnetic field in a millitesla scale can produce a controllable artificial strain as an indication signal for the remote optical interrogator. The relationship between the pre-defined magnetic field and its induced Bragg wavelength shift characterizes this validation concept. Any deviation of the local bonding state of the interfaces from the initial or/and any change of shear strain transferring mechanism from composite matrix to the optical fibre core will result in alterations in this sensitive relationship, and thus triggers an immediate alert for a further inspection. The finite element method is used to simulate the strain of this configuration as result of different values of the magnetic field in order to optimize the geometrical sensor parameters. The simulations are verified by experiments results. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A high-performance fiber Bragg grating-based (FBG) sensor device has been developed for the detection of small magnetic fields. Based on a smart multilayer jacket around the fibre over the physical length of the FBG, magnetic fields generated by rotating machine parts, power generators or power cable can be easily detected, analysed and evaluated. Consequently, this innovative, on-line and non-contact inspection method results in an increase in quality and reliability of high-performing machine parts, devices and cables. The basic physical principle is based on a magnetostrictive multilayer system that strains the high-resolution FBG element in presence of magnetic fields. Subsequently, a fixed relationship between induced magnetic field and wavelength change of the FBG element describes the characteristic sensitivity curve. Intensive tests regarding characterisation of this magnetic field FBG sensor have been carried out and its performance has been evaluated.
Strain sensors embedded in or attached to structural components have to measure the real deformation of the structure over the whole period of use. The user must know how reliably installed sensors provide strain measurement results. For this purpose, test facilities or coupon tests are used. In order to characterize the strain transfer quality from the host structure into surface-applied strain sensors, a unique testing facility has been developed. This facility can be used both for fiber optic and resistance strain sensors. Originally developed for fiber Bragg grating based sensors, the KALFOS facility (=calibration of fiber optic sensors) uses Digital Image Correlation (DIC) and Electronic Speckle Pattern Interferometer (ESPI) as unbiased referencing methods. It is possible to determine experimentally the strain transfer mechanism under combined thermal and mechanical loading conditions. This experimental characterization method will reveal weaknesses in commonly used strain sensors, and the investigation of the material systems used for fiber optic and other strain sensors (particularly the coating/substrate - adhesive combination). The KALFOS facility allows matching of specific measurement requirements with environmental conditions.
In Germany, the first guideline for the use of fiber Bragg grating strain sensors, 'Optical Strain Sensor based on Fiber Bragg Grating' (Berlin, Germany: Beuth-Verlag, 2010), has been developed by the GESA guideline group of VDI, 'The Association of German Engineers' and published by Beuth-Verlag. This guideline provides the basic specifications of this sensor type and the sensor characteristics, which have to be known for a reliable sensor performance. In conformity to this guideline, experimental investigations on the strain transfer characteristics of fiber Bragg grating patches have been carried out. A comparison between patches and resistance strain gauges during tensile tests and combined temperature and tensile loading was carried out. The evaluated strain gauge factor and the temperature sensitivity of the strain gauge factor have been compared to the manufacturer's data. The overall performance of the patches has been evaluated. The experimental investigations showed that there are considerable disagreements between the manufacturer's specifications and the observed characteristics.
How do application-related issues influence the reliability of fiber optic strain measurements?
(2011)
Fibre optic strain sensors are increasingly used and sensor systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor's the performance. The contribution will focus on issues that can deteriorate the sensor function or reduce the reliability of measurement results. Aspects are considered how to come to reliable strain measurements and how to validate strain measurements of applied sensors. Related to this topic, European activities like the recently started European COST TD1001 action, called (OfSeSa) will be presented.