A unique testing facility (KALFOS) using ESPI (electronic speckle pattern interferometery) as a referencing method has been realized for the characterisation of the strain transfer process from a component under load into surface applied fibre Bragg grating based strain sensors. The strain transfer mechanism can be described experimentally, while matching specific measurement requirements and environmental conditions.
Sensors integrated into devices and structures provide essential data to control, optimize or manage machines and structural components. In the last years, processes, applications and machine parts became more and more intelligent. Consequently, the need for sensor validation increased significantly in order to rely on sensor data and measurement results.
Structure-integrated fibre optic strain sensors, such as fiber Bragg gratings (FBG), are of special interest in the composite manufacturing industry. This type of sensor makes it possible to gain information and to collect measurement data about entire production processes and whole life-time cycles of composite-made machine parts and structures. However, validation concepts and approaches for this type of sensors are barely reported in literature. Furthermore, all the reported activities have the drawback that the sensor diagnosis strategy is implemented as limited mathematical models and/or complex time-consuming spectral analysis tools which are applied in data post-processing loops. However, to automate sensor validation and to apply real-time and in-field sensor fault detection, it is necessary to acquire measurement data and information about the measurement reliability at the same time.
A fiber Bragg grating (FBG) strain patch specially adapted for long-term and high-strain applications has been developed and characterized. The design concept for the patch is based on a glass-fiber reinforced plastic (gfrp) carrier material. The developed concept for the FBG integration into the carrier material was derived from reliable integration procedure of FBG sensors into composite structures. The patches' temperature sensitivity, strain gauge factor, fiber–matrix interface adhesion and fatigue behavior were characterized. As a result, FBG strain patches with linear temperature and strain behavior, as well as excellent fatigue resistance, were developed and can be used as part of a monitoring system for advanced composite materials in aerospace structures or wind turbine power plants.
A fibre Bragg grating (FBG) strain patch specially adapted for long-term and high-strain applications was developed and characterised. Additionally, in the case of unknown main stress axis, two fibre optic strain rosettes were developed. The design concept for the patch and the rosettes is based on a glass fibre reinforced plastic (gfrp) carrier material. The patches were characterised due to their strain gauge factor and fatigue behaviour. As a result, FBG strain patches with linear strain behaviour and excellent fatigue resistance were developed and can be used as part of a monitoring system for aerospace structures or wind turbine power plants. The rosettes were designed to be small in geometrical size and their strain transfer behaviour was characterised.
Fiber-optic strain sensors are increasingly used in very different technical fields. Sensors are provided with specifications defined by the manufacturer or ascertained by the interested user. If deformation sensors are to be used to evaluate the long-term behavior of safety-relevant structures or to monitor critical structure components, their performance and signal stability must be of high quality to enable reliable data recording. The measurement system must therefore be validated according to established technical rules and standards before its application and after. In some cases, not all details of the complex characteristic and performance of applied fiber-optic sensors are sufficiently understood, or can be validated because of a lack of knowledge and methods to check the sensors' behavior. This contribution focusses therefore on the importance of serious validation in avoiding a decrease or even deterioration of the sensors' function. Methods for validation of applied sensors are discussed and should reveal weaknesses in validation of embedded or integrated fiber-optic deformation and/or strain sensors. An outlook to some research work that has to be carried out to ensure a well-accepted practical use of fiber-optic sensors is given.
Fiber-optic strain sensors are increasingly used in very different technical fields. Sensors are provided with specifications defined by the manufacturer or ascertained by the interested user. In some cases, sensor specification is not sufficiently validated and must therefore additionally be validated in a laboratory, primarily to ensure reliable measurement information over the intended period of operation. Even if the performance of delivered sensor is well specified, the sensor's strain characteristics and the performance of an applied sensor can significantly differ from the virgin sensor's performance. In this case, applied sensors do not provide full reliability and lead sometimes to uncertain measurement results. This contribution will therefore focus on the role of validation in avoiding a decrease or even deterioration of the sensor function of applied sensors. Experimental validation - not only modelling - is very important, however, before experimental investigations are planned knowledge about key issues and problems that influence the measurement results must be available. Few aspects to be considered and investigated will be discussed. Selected experimental facilities to reveal weaknesses in the sensor function will be described; an outlook to open questions is given.
Fiber optic strain sensors are increasingly used and sensor Systems are provided with specifications. Even if the performance is well specified, the strain characteristics of the sensor, strain transfer factor, mechanical stability under thermal influences, the performance of applied strain sensors can seriously differ from virgin sensor’s the performance. Therefore the contribution considers validation issues to come to reliable strain measurements and how to validate strain measurements of applied sensors. A new validation facility will be presented.
Reliable measurement results with fibre optic sensors require profound knowledge of physical mode of function, of materials used and appropriate application. There is often serious discrepancy between use in laboratory environment and on site. The paper identifies important aspects to be considered and shows ways to transfer innovations onto practical use.
Fiber optic sensors are increasingly used because of their outstanding performance or if special requirements avoid the application of conventional electrical sensors. The scientific background for optical fiber sensors is well developed; however, the characteristic of sensors applied in rather harsh environment are almost always different from characteristics determined in laboratory or before its installation. In order to achieve long-term stable function and reliable measurement data after application and under harsh environmental conditions, guidelines for characterization and specification of sensor components are needed as well as methodologies for testing the sensor performance must be developed. Performance tests carried out revealed that there are still some restrictions with respect to long-term reliable use: first, some sensor products available on the market are not very often appropriately characterized, described and validated; second, application procedures are not always defined due to a lack of understanding the micromechanical issues in the interface zone between sensor and measuring object. Application procedures and profound knowledge of materials behaviour are necessary to get results from the sensor that can be reliably used. The paper describes first guidelines to prove the quality of fiber optic strain sensors, a testing facility developed for unbiased tests and certification of surface-applied sensors as well as result from comparison of commercially available strain sensors.
Strain sensors embedded in or attached to structural components have to measure the real deformation of the structure over the whole period of use. The user must know how reliably installed sensors provide strain measurement results. For this purpose, test facilities or coupon tests are used. In order to characterize the strain transfer quality from the host structure into surface-applied strain sensors, a unique testing facility has been developed. This facility can be used both for fiber optic and resistance strain sensors. Originally developed for fiber Bragg grating based sensors, the KALFOS facility (=calibration of fiber optic sensors) uses Digital Image Correlation (DIC) and Electronic Speckle Pattern Interferometer (ESPI) as unbiased referencing methods. It is possible to determine experimentally the strain transfer mechanism under combined thermal and mechanical loading conditions. This experimental characterization method will reveal weaknesses in commonly used strain sensors, and the investigation of the material systems used for fiber optic and other strain sensors (particularly the coating/substrate - adhesive combination). The KALFOS facility allows matching of specific measurement requirements with environmental conditions.