Five distinct analytical techniques were compared for the quantification of the H2O (0·1-7·4 wt%) and D2O (up to 5·5 wt% D2O) contents in rhyolitic glasses. The hydrogen concentration in obsidians was measured using nuclear reaction analysis (NRA) and converted into H2O concentration. The bulk water content (H2O+D2O) of synthesised glasses was determined using thermal extraction in conjunction with KarlFischer titration (KFT). Unextracted H2O was measured by infrared (IR) spectroscopy after remelting the KFT products at high pressure. These well characterised glasses were subsequently used to calibrate secondary ion mass spectrometry (SIMS), infrared and evolved gas analysis (EGA). The calibrations of SIMS for H2O and D2O show a significant matrix effect at H2O and D2O concentrations larger than ~3 mol/l with the relative sensitivity factor (RSF) decreasing with bulk water content. Molar absorption coefficients for the OH stretching vibration band at 3570 cm-1 and the OD stretching vibration band at 2650 cm-1 in the infrared absorption spectra were reinvestigated. In the range 0·1-6 wt% the H2O content of glasses could be reproduced within analytical error using a constant linear molar absorption coefficient. However, it appears that the absorption coefficients for the 3570 cm-1 band as well as for the 2650 cm-1 band both decrease systematically with concentration of dissolved H2O and D2O (epsi3570=80 (±1) - 1·36(±0·23)CH2Ot and epsi2650=61·2(±1) - 2·52(± 0·30)CD2Ot). EGA allows quantification of the H2O content as well as the study of dehydration kinetics. It is shown that H2O is released under vacuum already at room temperature from glasses containing >7 wt% H2O.
Hydrogen analysis is of particular importance in thin film technology and it is often necessary to obtain a depth profile. The method with the best depth resolution is NRA using the 6385 keV resonance of the 1H(15N,αγ)12C nuclear reaction. The correct quantification of the depth and concentration scales in the measured hydrogen profiles relies on accurate stopping power values. We present a method to deduce these values from a combination of two techniques: NRA and X-ray reflectometry (XRR). This method is applied to the determination of the stopping power of ~6.4 MeV 15N ions in H-containing amorphous Si-layers (a-Si:H). Density-independent stopping powers at different H concentrations are determined by combining the results from NRA and XRR with an overall uncertainty of 3.3%, showing good agreement with SRIM values. This work shows exemplary the methodology for future evaluation of stopping powers for quality assurance in NRA.
Well-defined and facetted bimetallic gold–palladium nanoalloys have been synthesized and anchored in spherical polyelectrolyte brushes (SPB) as composite particles (AuPd@SPB). These particles are better catalysts in aqueous phase than the pure metals. The atomistic arrangement of these nanoalloys has been analysed by extended X-ray absorption fine structure (EXAFS) spectroscopy at the Au–L3 and the Pd–K absorption edge. The samples with high amounts of gold appear as almost statistically mixed random alloys. Alloy compositions with less gold show slight enrichment of Pd at the surface of the particle. In addition, signals of non-metallic palladium appear at the Pd–K edge which indicate the presence of the Pd2+ species in addition to metallic palladium. The relation of these structural features to the catalytic activity is discussed.
We present a new high resolution X-ray imager based on a pnCCD detector and a polycapillary optics. The properties of the pnCCD like high quantum efficiency, high energy resolution and radiation hardness are maintained, while color corrected polycapillary lenses are used to direct the fluorescence photons from every spot on a sample to a corresponding pixel on the detector. The camera is sensitive to photons from 3 to 40 keV with still 30% quantum efficiency at 20 keV. The pnCCD is operated in split frame mode allowing a high frame rate of 400 Hz with an energy resolution of 152 eV for Mn Kα (5.9 keV) at 450 kcps. In single-photon counting mode (SPC), the time, energy and position of every fluorescence photon is recorded for every frame. A dedicated software enables the visualization of the elements distribution in real time without the need of post-processing the data. A description of the key components including detector, X-ray optics and camera is given. First experiments show the capability of the camera to perform fast full-field X-Ray Fluorescence (FF-XRF) for element analysis. The imaging performance with a magnifying optics (3×) has also been successfully tested.
A new setup for fast spatially resolved measurements of elemental trace amounts under total reflection conditions using a new colour X-ray camera is described. Samples prepared on conventional total reflection X-ray fluorescence (TXRF) reflectors were measured at BESSY II synchrotron. A spatial resolution of 50 × 50 µm² was obtained, while the required time for the investigation of a 10 × 10 mm² sample is 30 seconds. The set-up is up to 350 times faster than conventional X-ray fluorescence systems for elemental traces. The major components of the X-ray camera are polycapillary optics and a pn-CCD chip with an active area of 13 × 13 mm². This area is divided into 264 × 264 pixels of 48 × 48 µm². A full X-ray spectrum with a resolution of 152 eV @ 5.9 keV and a chip temperature of 246 K is recorded for each pixel. The chip has a read-out rate of 400 Hz.
In many areas of material sciences, hydrogen analysis is of particular importance. For example, hydrogen is most abundant as impurity in thin film materials depending on the deposition process and has great influence on the chemical, physical and electrical properties of many materials. Existing bulk reference materials (RMs) are not suited for surface sensitive analytical methods like elastic recoil detection analysis (ERDA) or nuclear reaction analysis (NRA). To overcome this serious lack of (certified) thin-layer reference materials for the determination of hydrogen in the near-surface region (12 µm depth), we produced stable, homogeneous amorphous silicon layers on Si-wafers (aSi:HSi) by means of chemical vapour deposition (CVD), while about 10% of hydrogen was incorporated in the Si-layer. Homogeneity and stability were proved by NRA whereas traceability of reference values has been assured by an international interlaboratory comparison.
A set of compound refractive lenses (CRLs), mounted on a silicon wafer, was obtained from the Institut für Mikrostrukturtechnik Karlsruhe. The CRLs were characterized at the BAMline at the synchrotron BESSYII in Berlin. It could be demonstrated that beam diameters below 1 µm can be obtained. The beam size accepted by the lenses is (140 × 140) µm2, thus the intensity gain in the micrometer spot, including absorption, is about 15,000. It is possible to switch between different beam energies within a few minutes. First results of scans and the application of the lenses for MicroXANES (X-ray absorption near-edge structure) measurements are presented in this paper. Also, the possibility of MicroEXAFS (extended X-ray absorption fine structure) measurements is discussed.