Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (99)
- Vortrag (54)
- Zeitschriftenartikel (52)
- Beitrag zu einem Sammelband (37)
- Posterpräsentation (7)
- Buchkapitel (1)
- Forschungsbericht (1)
Schlagworte
- Radiography (16)
- Digital radiography (14)
- POD (14)
- Radiographie (14)
- Zerstörungsfreie Prüfung (12)
- ZfP (12)
- Image quality (11)
- Bildqualität (10)
- NDT (8)
- Simulation (8)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (54)
We analyzed the results of high-energy X-ray CT scans for three 20×16×16 in. block samples of Indiana limestone from our recent radial acidizing experiments with HCl. CT scans were done for complete samples, and 3D images of internal dissolution patterns were built. Each 3D image consists of submillimeter-size voxels to capture fine details of individual wormholes.
The obtained 3D images of acidized blocks allow us to observe from various angles the details of the wormholes obtained in the three experiments, which demonstrated wide pore-volume-to-breakthrough (PVBT) range with three different injection rates. Also, variation of the CT number reveals the presence of depositional layers in all block samples, and the obtained CT images were used to interpret the effect that rock layers might have on wormhole penetration at different injection rates.
Further, the built voxel models were used to calculate the radial distributions of dissolved rock volume, which otherwise are not obvious for such complex branched structures as wormholes. We observed how varied experimental conditions affected those distributions. The radial distributions were found very similar across the samples, which suggested the way to detect the effective wormhole penetration depth.
Best energy selection for different applications with digital detector arrays from 20 to 600 keV
(2012)
New Digital Radiography Procedure Exceeds Film Sensitivity Considerably in Aerospace Applications
(2006)
Einfluss von Metall-Speicherfolien-Kombinationen auf die Bildqualität in der Computer-Radiographie
(2008)
Bei der Normgestaltung für Speicherfolien sind die Auswirkungen von Metallfolien und Metallfolienkombinationen auf die Bildqualität von Speicher-folienaufnahmen nicht ausreichend berücksichtigt worden. Es ist bekannt, dass bei Film - Metallfolien - Kombinationen zusätzlich zur Änderung der optischen Dichte und der Filmgranularität auch Änderungen der inneren Unschärfe durch den seitli-chen Energietransport in der Film Metallfolien - Kombination entstehen, welche überwiegend durch ausgelöste Elektronen und zum Teil durch sekundäre Strahlung hervorgerufen werden. Gleichzeitig dienen die Metallfolien bei Röntgenaufnahmen mit Film als Streustrahlfilter und können zur Verbesserung des Bildkontrastes bei-tragen. Die Mechanismen zur Erzeugung des virtuellen Röntgenbildes und dessen Visualisierung sind in Speicherfolien nicht mit denen in einem Röntgenfilm iden-tisch. Demzufolge können die in den Normen festgelegten Vorschriften zum Einsatz von Metallfolien in der Filmradiographie nicht auf Speicherfolien uneingeschränkt übertragen werden. Anhand der hier erzielten Ergebnisse lassen sich Empfehlungen zum zukünftigen Einsatz der Metallfilter und -folienkombinationen für die Speicher-folientechnik zur Verbesserung der Bildgüte ableiten.
Radiography is a helpful method to identify the inherent structure of unexploded ordnances (UXOs). Portable Computed Radiography (CR) systems on the basis of phosphor imaging plates , have attracted attention for NDT-applications during the last few years. A portable IP system ACR 2000 has been tested for X-ray inspection of UXO's in the field. Digitised radiographs are presented to explain the needs and demands for a reliable characterisation of UXO's. Computed radiographs of UXOs are compared with film radiographs exposed in the same way, to evaluate the reliability and to identify advantages and disadvantages of the CR system for UXO inspection. Film based and CR systems provide sufficient information for identification of chemical warfare agents in UXO's, which is an essential problem for explosive ordnance disposal. The advantages and the potential of the portable CR system is discussed on the basis of experiences gathered during different field trails.
Speicherfoliensysteme werden seit den 80-iger Jahren in der Röntgendiagnostik
eingesetzt. Die technische Modifizierung der anfänglich im medizinischen Bereich
genutzten Speicherfoliensysteme ermöglichte die Einführung der Computer-Radiographie
(CR) in die Digitale Industrielle Röntgenprüfung mit dem Ziel des Filmersatzes. Die Speicherfolien
detektieren im Vergleich zum Röntgenfilm einen wesentlich größeren
Dosisbereich. Die daraus resultierende Dynamik befähigt die Speicherfoliensysteme zur
Abbildung eines großen Objektumfanges und verringert zugleich das Risiko einer Fehlbelichtung.
Vor allem die Möglichkeit, unmittelbar nach dem Belichten das virtuell im Speicherleuchtstoff
gespeicherte Durchstrahlungsbild auszulesen, in digitalisierter Form im PC
zu speichern und auf dem Bildschirm betrachten zu können, verdeutlicht die Vorteile von
CR Systemen beim Gebrauch in der Durchstrahlungsprüfung. Eine vollständige Ablösung
des Röntgenfilmes durch digitale Techniken ist jedoch erst dann zu erwarten, wenn es gelingt,
eine Bildqualität zu erreichen, die besser oder gleichwertig zu der vom jeweiligen
Röntgenfilmsystem geforderten ist. Mit diesem Ziel hat in den letzten Jahren eine technische
Weiterentwicklung von CR Systemen für den industriellen Einsatz stattgefunden. Im
gleichen Zeitraum wurden mehrere Standards zur Bewertung von CR Systemen und zu
deren richtigen Gebrauch in der Durchstrahlungsprüfung entwickelt.
Heutzutage ist die Herstellung von Durchstrahlungsbildern mit einer entsprechend gewünschten
Bildgüte sichergestellt, was in den letzten Jahren zum verstärkten Einsatz von
CR Systemen in der Durchstrahlungsprüfung führte.
Im Rahmen einer von der EU finanzierten Studie (Filmfree) wurden anfänglich systematische
Untersuchungen zu den Einsatzmöglichkeiten und grenzen von CR Systemen für die
Durchstrahlungsprüfung von aluminothermischen Schweißnähten in Schienen durchgeführt.
Anhand der Ergebnisse ließen sich optimale Bedingungen und Strategien für die Durchstrahlungsprüfung
von Schienen ableiten, die anschließend im vor Ort Einsatz auf der
Teststrecke der Deutschen Bahn verifiziert wurden.
Im vorgestellten Beitrag werden die Vorteile des Einsatzes von CR Systemen bei der
Durchstrahlungsprüfung von aluminothermischen Schweißnahtverbindungen dargestellt
und deren Verwendung unter realen Verkehrsbedingungen im Schienenverkehr beschrieben.
Es wird gezeigt, wie unter den bestehenden Fahrbetriebsbedingungen die Durchstrahlungsprüfung
von Schweißungen in verlegten Schienen umgesetzt werden kann.